• 제목/요약/키워드: Heat Transfer Experiment

검색결과 742건 처리시간 0.026초

모듈형 수관식 보일러를 위한 열교환 모듈의 열전달 특성 (Heat Transfer Characteristics of Heat Exchange Module for a Water Tube Type Modular Boiler)

  • 안준;김종진;강새별
    • 설비공학논문집
    • /
    • 제24권3호
    • /
    • pp.265-270
    • /
    • 2012
  • A finned tube type heat exchange module has been proposed for a multi-burner water tube boiler. Fin density and length increase in streamwise direction to equalize the evaporation for each module, which makes it difficult to apply conventional bulk design procedure. The design program has been improved by updating data for every row of tubes along the flow. A numerical simulation has been also conducted to evaluate the effect of inlet conditions and validated with experiment. The heat transfer of the first row has been underpredicted by the conventional Zhukauskas correlation, since the acceleration of the flow due to the blockage is not fully inflected. The fin tip temperature is also underpredicted by Bessel solution, because of the interaction with neighboring fins.

$CO_2$ 열펌프용 내부 열교환기의 냉방조건에서 열전달 및 압력 강하 특성에 대한 연구 (Study on Heat Transfer and Pressure Drop Characteristics of Internal Heat Exchanger for $CO_2$ Heat Pump under Cooling Condition)

  • 김대훈;이상재;최준영;이재헌;권영철
    • 설비공학논문집
    • /
    • 제20권8호
    • /
    • pp.517-525
    • /
    • 2008
  • In order to study the heat transfer and pressure drop of an internal heat exchanger for $CO_2$ heat pump under cooling condition, the experiment and numerical analysis were performed. Four kinds of internal heat exchangers with a coaxial tube type and a micro-channel tube type were used. The experimental apparatus consisted of a test section, a power supply, a heater, a chiller, a mass flow meter, a pump and a measurement system. The section-by-section method and Hardy-Cross method were used for the numerical analysis. The effects of the internal heat exchanger refrigerant flow rate, the length of the internal heat exchanger, the operating condition of the gas-cooler, the evaporator and the type of the internal heat exchangers were investigated. With increasing of the flow rate, the heat transfer rate increased about 25%. The heat transfer rate of the micro-channel tube type was higher about 100% than that of the coaxial tube type. With increasing of the length of the internal heat exchanger, the heat transfer rate increased about $20{\sim}50%$. The pressure drop of the low-side tube was larger compared with that of the high-side tube.

Heat Generation Model of Angular Contact Ball Bearing with Oil-Air Lubrication

  • Na, Hee-Hyeong;Rhim, Yoon-Chul
    • KSTLE International Journal
    • /
    • 제1권1호
    • /
    • pp.63-68
    • /
    • 2000
  • Angular contact ball bearings are mainly used in the spindle, which requires high speed and stiffness. The heat generation is studied by experiments and simulations using a pair of angular contact ball bearings. The temperature variation of inner and outer races and the temperature increment distribution are measured by using thermocouples for the rotational speed, preload, viscosity of lubricant. The measured values from experiments are used to estimate the heat conduction rate. The method of oil-air lubrication is used for the experiment. The amount of conduction heat transfer to the test spindle and the convection heat transfer coefficients long the spindle are computed by using inverse method with temperature increment distribution. Total heat generation rate is estimated with the heat partition rate which is calculated from temperatures of inner and outer races. In addition, the empirical factor of oil-air lubrication method for Palmgren's heat generation model is suggested. The empirical friction coefficients, which are obtained from the experiments, depend on the preload condition, and can give us more accurate estimation of the heat generation in ball bearings.

  • PDF

타원관 열교환기의 열전달 특성 (Heat Transfer Characteristics of Oval-Tube Heat Exchanger)

  • 윤점열;이욱용
    • 설비공학논문집
    • /
    • 제12권3호
    • /
    • pp.292-301
    • /
    • 2000
  • This study experimentally investigates an air-side performance of oval tube heat exchanger against round tube heat exchanger using scaled-up model experiment for home air conditioners. A plain fin and round tube heat exchanger with 21 FPI(fins per inch) was used as a reference heat exchanger, and these were applied equally to 4 oval tube heat exchangers. Oval tube samples were designed with the same perimeter as 7.5mm diameter round tube, and their aspect ratios were 1:2, 1:3, respectively. In this study, the heat transfer and pressure drop characteristics of oval tube heat exchangers against round tube heat exchanger were also compared to one another, and an optimal samples for home air conditioners was recommended. And, general performance characteristics for an optimum oval tube samples chosen in this work was compared with round tube heat exchanger.

  • PDF

석유 팬 히터의 연소실 주변 열전달 특성 (Heat transfer characteristics around a circular combustion chamber of kerosene fan heater)

  • 김장권
    • 대한기계학회논문집B
    • /
    • 제22권4호
    • /
    • pp.551-561
    • /
    • 1998
  • This paper was studied to understand the characteristics of heat transfer coefficients and surface temperature distributions around a circular combustion chamber within the heat-intercept duct of kerosene fan heater. The experiment was carried out in the heat-intercept duct of kerosene fan heater attached to the blow-down-type subsonic wind tunnel with a test section of 240 mm * 240 mm * 1200 mm. The purpose of this paper was to obtain the basic data related with normal combustion for new design from conventional kerosene fan heater, and to investigate the effect of surface temperature, local and mean heat transfer coefficients versus flow-rate of convection axial fan according to the variations of heat release conditions from kerosene fan heater during normal combustion. Consequently it was found that (i) the revolution of convection axial fan during combustion had a smaller value than that of non-combustion because of the thermal resistance due to the high temperature in the heat-intercept duct, (ii) the pressure ratio P$_{2}$/P$_{1}$ had a comparatively constant value of 0.844 according to the revolution increase of turbo fan and the heating performance of kerosene fan heater had a range of 1,494 ~ 3,852 kcal/hr, (iii) the local heat transfer coefficient around a circular combustion chamber had a comparatively larger scale in the range of 315 deg. < .theta. < 45 deg. than that in the range of 90 deg. < .theta. < 270 deg. as a result of heat transfer difference between front and back of a circular combustion chamber, and (iv) the mean heat transfer coefficient around a circular combustion chamber increased linearly like a H$_{m}$=95.196Q+104.019 in condition of high heat release according to the increase of flow-rate of axial fan.n.

비선형 열전달 계수를 사용한 알루미늄 6082 빌렛의 열간 압축 공정 해석 (Analysis of Hot Compression Process of Aluminum 6082 Billet using Nonlinear Heat Transfer Coefficient)

  • 전효원;서창희;권태하;박춘달;전진호;최현열;강경필
    • 소성∙가공
    • /
    • 제28권1호
    • /
    • pp.5-14
    • /
    • 2019
  • In order to reduce the weight of automobile parts, automobile parts using aluminum alloy are being developed. Aluminum alloy for automobile parts is mainly made of Al6xxx (Al-Mg-Si) type alloy, which is excellent in hot forming property, and it can increase mechanical properties by the use of heat treatment. In this study, hot forming was performed using Al6082. Before the hot forming, the forming analysis was performed using the DEFORM-3D finite element analysis program in this case. For the forming analysis, the heat transfer coefficient was derived from the experiment, and the forming analysis was performed by applying it. At the forging analysis, the temperature of Al6082 material was set to 813K and that of the mold was set to room temperature. After the forging analysis, the experiment was performed, and the forging analysis and the experimental results were compared.

분산형 소형 연료전지용 1KW급 열교환기 설계 (Heat Exchanger Design For The Individually Allocated Fuel Cell For 1kw Power generation)

  • 이택홍;박태성;김태완;노재현;강영진
    • 한국수소및신에너지학회논문집
    • /
    • 제25권1호
    • /
    • pp.39-46
    • /
    • 2014
  • Our lab designs a heat exchangers for hydrogen gas. Coolant is water, thus it is very difficult to determine heat transfer parameters in this gas-liquid system. Repeated experiments gives overdesign value 6.06%, overall heat transfer coefficient 36.32 ($kcal/m^2-hr-^{\circ}C$) for Hydrogen. Theoretically determined overall heat transfer coefficient is 38.44 ($kcal/m^2-hr-^{\circ}C$). Our lab simulated this system and overdesign 30.4% shows good match with this experiment by HTRI. These parameters are in same range with literature.

충돌분류계에서 WIRE MESH를 이용한 열전달 증진에 관한 연구 (The Study on The Heat Transfer Enhancement Using Wire Mesh in Impinging Jet System)

  • 금성민;김동춘;유지오;이창언;임장순
    • 태양에너지
    • /
    • 제17권1호
    • /
    • pp.47-58
    • /
    • 1997
  • 본 연구는 2차원 충돌공기분류계의 포텐셜코어 영역에서 열전달증진을 목적으로 노즐출구와 전열면사이에 메쉬를 설치한후 노즐출구 속도, 메쉬와 전열면사이의 간극, 노즐출구와 전열면사이의 거리를 변화시킬 때의 열전달특성을 메쉬를 설치하지 않은 경우와 비교 검토한 것으로 메쉬를 설치했을 때에는 분류가 전열면에 충돌하면서 소분류로 분할되어 발생하는 난류에 의해 충돌영역에서 열전달성능이 좋아지며, 또한 벽면분류영역으로 진행하면서 홀과 홀사이의 밑부분에서 일어나는 가속으로 인해 열전달성능이 향상된다. 특히 메쉬와 전열면사이의 간극을 변화시켰을 경우 정체점부근에서는 간극이 클수록, 벽면분류영역에서는 간극이 작을수록 전달성능은 향상되며 U=18m/s, H/B=2, C=1인 경우에는 메쉬를 설치하지 않은 평판보다 평균 약 44%의 열전달증진 효과과 있었다. 그리고 본 실험결과를 기존의 난류촉진체를 이용한 연구결과와도 비교 검토하였다.

  • PDF

Natural Convection Heat Transfer Characteristics of the Molten Metal Pool with Solidification by Boiling Coolant

  • Cho, Jae-Seon;Suh, Kune-Yull;Chung, Chang-Hyun;Park, Rae-Joon;Kim, Sang-Baik
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1997년도 추계학술발표회논문집(1)
    • /
    • pp.719-725
    • /
    • 1997
  • This paper presents results of experimental studies on the heat transfer and solidification of the molten metal pool with overlying coolant with boiling. The metal pool is heated from the bottom surface and coolant is injected onto the molten metal pool. As a result, the crust, which is a solidified layer, may form at the top of the molten metal pool. Heat transfer is accomplished by a conjugate mechanism, which consists of the natural convection of the molten metal pool, the conduction in the crust layer and the convective boiling heat transfer in the coolant. This work examines the crust formation and the heat transfer rate on the molten metal pool with boiling coolant. The simulant molten pool material is tin (Sn) with the melting temperature of 232$^{\circ}C$. Demineralized water is used as the working coolant. The crust layer thickness was ostensibly varied by the heated bottom surface temperature of the test section, but not much affected by the coolant injection rate. The correlation beかeon the Nusselt number and the Rayleigh number in the molten metal Pool region of this study is compared against the crust formation experiment without coolant boiling and the literature correlations. The present experimental results are higher than those from the experiment without coolant boiling, but show general agreement with the Eckert correlation, with some deviations in the high and low ends of the Rayleigh number. This discrepancy is currently attributed to concurrent rapid boiling of the coolant on top of the metal layer.

  • PDF

태양열 공기난방기에서 핀의 형상에 따른 열전달 성능 평가 (Research on Thermal Performance by Different Fins in a Solar Air Heater)

  • 최휘웅;홍부표;윤정인;손창효;최광환
    • 한국태양에너지학회 논문집
    • /
    • 제33권6호
    • /
    • pp.85-91
    • /
    • 2013
  • It is essential to reduce the amount of fossil fuel because facing with the natural problem such as a global warming. To achieve this goal, many of interests in the use of renewable energy is growing. Especially, as one of these renewable energy systems, a solar air heater invention has been conducted for enhancing the efficiency of solar air heater. According to this trend, scale-down sized experiment apparatus was constructed and performed for searching a proper fin and confirming the heat transfer performance by fin shape on constant heat condition to enhance efficiency of solar air heater. In this experiment, heat gain, convection heat transfer coefficient, number of transfer units, Nusselt number, Reynold's number, friction factor, performance factor were investigated in order to evaluate the thermal characteristics based on the real data obtained. By comparison with the each fin performance, a zigzag shape keeping a right angle to the plate had the highest value among them.