• 제목/요약/키워드: Heat Transfer Experiment

검색결과 742건 처리시간 0.026초

유냉각기의 열전달 촉진에 관한 연구 (A Study on Heat Transfer Enhancement of Oil Cooler)

  • 조동현;임태우
    • 동력기계공학회지
    • /
    • 제15권3호
    • /
    • pp.25-30
    • /
    • 2011
  • A shell-and-tube oil cooler with plate fins was suggested to improve the defect of the conventional shell-and-tube oil cooler. Experiments were conducted to evaluate the heat transfer performance on the shell side of shell-and-plate finned tube oil cooler with three different tube numbers(9, 13 and 19). Oil flowing on the shell side was cooled by cold water flowing inside the tubes. A shell-and-tube heat exchanger of an oil cooler consisted of one shell pass and two tube passes with the inner tube diameter of 8.82 mm and the tube length of 575 mm. From the experiment of shell-and-tube oil cooler, it was found that the heat transfer coefficient of oil cooler with 9 tubes, as oil flow rate was increased, was approximately 140% and 250% higher than that of 13 and 19 tubes, respectively. The heat transfer coefficient at the water flow rate of $3m^3/h$, also was 120% and 140% higher than that of 2.4 and $1.8m^3/h$, respectively.

거친 사각채널에서 열전달과 유체유동 특성에 관한 실험 및 수치해석 (Experimental and Numerical Investigation on Heat Transfer and Fluid Flow Characteristics in the Ribbed Square Channel)

  • 강호근;배성택;이대희;안수환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권2호
    • /
    • pp.275-283
    • /
    • 2006
  • Experiment and three dimensional numerical investigations of incompressible turbulent flow through square channels with one- and two-sided ribbed walls are performed to determine pressure drop and heat transfer. The CFX(version 5.7) software package is used for the computation. The ribbed walls have a $45^{\circ}$ inclined square rib. Uniform heat flux is maintained on whole inner heat transfer channel area. The numerical results coincide with experimental data that obtained for $7,600{\le}Re{\le}24.900$, the pitch-to-rib height ratio (p/e) of 8.0. and the rib height-to-channel hydraulic diameter ratio ($e/D_h$) of 0.0667. The results show that values of local heat transfer coefficient and friction factor in the channel with two-sided ribbed wall are higher than those in the channel with one-sided ribbed walls.

초임계압 열전달 특성에 관한 실험 연구 (Experimental Study on the Heat Transfer Characteristics under the Supercritical Pressures)

  • 강경호;윤영중;박종국;추연준;천세영;송철화
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2242-2247
    • /
    • 2008
  • A series of experiments have been performed in a vertical tube of 9.4 mm inner diameter using the Freon, HFC-134a as working fluid medium under the supercritical pressure range. Two kinds of experiments, i.e. steady-state and pressure transient, have been carried out. As for the steady-state heat transfer experiment, the mass flux was in the range between 600 and $2000\;kg/m^2s$ and the maximum heat flux was $160\;kW/m^2$. The selected pressures were 4.1, 4.3 and 4.5 MPa which correspond to 1.01, 1.06 and 1.11 times the critical pressure, respectively. In the pressure transient experiments, the inlet pressures were varied from 3.8 to 4.5 MPa and vice versa in the pressure transient simulations. In this study, heat transfer correlation and criterion for the heat transfer deterioration are suggested under the supercritical pressures. And also heat transfer characteristics during the pressure transient are examined.

  • PDF

공압구동형 제빙기의 열전달 특성에 관한 실험적 고찰 (The Experimental Study on the Heat Transfer Characteristics of Ice Slurry Generator Using Air Cylinder)

  • 김민준;김종하;윤재호;박일환;이규칠
    • 설비공학논문집
    • /
    • 제19권11호
    • /
    • pp.743-750
    • /
    • 2007
  • In this study, ice slurry generator using air cylinder was designed and manufactured to investigate the heat transfer characteristic of the ice slurry generator. The ice slurry generator has the same shape as the shell-and-tube type heat exchanger. Refrigerant is flowing in the shell side and ethylene glycol solution in the tube side. The experiment was conducted on performance of ice slurry generator using air cylinder with standard condition and the results are plotted on the time scale. The experimental tests on the various concentration of ethylene glycol solution, the various solution velocity in the tube side and the various tube size have been carried. For the above experimental conditions, ice making characteristics of the ice slurry generator are evaluated in terms of the overall heat transfer coefficient. And the experimental results show that the overall heat transfer coefficient of the system is increased as the tube size and the concentration of ethylene glycol decreases.

적층형 Multi-Chip Module(MCM) 내부에 삽입된 초소형 열교환기 내에서의 대류 열전달 현상에 대한 연구 (A Study on the Convective Heat Transfer in Micro Heat Exchanger Embedded in Stacked Multi-Chip Modules)

  • 신중한;강문구;이우일
    • 대한기계학회논문집A
    • /
    • 제28권6호
    • /
    • pp.774-782
    • /
    • 2004
  • This article presents a numerical and experimental investigation for the single-phase forced laminar convective heat transfer through arrays of micro-channels in micro heat exchangers to be used for cooling power-intensive semiconductor packages, especially the stacked multi-chip modules. In the numerical analysis, a parametric study was carried out for the parameters affecting the efficiency of heat transfer in the flow of coolants through parallel rectangular micro-channels. In the experimental study, the cooling performance of the micro heat exchanger was tested on prototypes of stacked multi-chip modules with difference channel dimensions. The simulation results and the experiment data were acceptably accordant within a wide range of design variations, suggesting the numerical procedure as a useful method for designing the cooling mechanism in stacked multi-chip packages and similar electronic applications.

평판 핀 튜브 열교환기의 공기측 강제대류 열전달계수에 대한 실험 및 수치계산 (Experimental Measurement and Numerical Computation on the Air-Side Forced Convective Heat Tranfer Coefficient in Plate Fin-Tube Exchangers)

  • 윤영환;팽진기;윤건식
    • 설비공학논문집
    • /
    • 제18권9호
    • /
    • pp.729-737
    • /
    • 2006
  • Air-side forced convective heat transfer of a plate fin-tube heat exchanger is investigated by experimental measurement and numerical computation. The heat exchanger consists of staggered arrangement of refrigerant pipes of 10.2 m diameter and the pitch of fins is 3.5 m. In the experimental study, the forced convective heat transfer is measured at Reynolds number of 1082, 1397, 1486, 1591 and 1649 based on diameter of refrigerant piping and mean velocity. Average Nusselt number for the convective heat transfer coefficient is also computed for the same Reynolds number by commercial software of STAR-CD with standard $k-{\varepsilon}$ turbulent model. It is found that the relative errors of average Nusselt numbers between experimental and numerical data are less than 6 percentage in Reynolds number of $1082{\sim}1649$. The errors between experiment and other correlations are ranged from 7% to 32.4%. But the correlation of Kim at al is closest to the experimental data within 7% of the relative error.

냉장고 멀리언부 구조보강용 철구조물의 열손실 영향 연구 (A Study on the Heat Loss Effect of Steel Structure in a Refrigerator Mullion)

  • 하지수
    • 에너지공학
    • /
    • 제23권2호
    • /
    • pp.35-41
    • /
    • 2014
  • 본 연구는 냉장고의 냉장실과 냉동실 사이에 있는 멀리언부의 가스켓 주위의 열전달 해석을 수행하여 이 부분에서 열손실을 크게 하는 구조물인 구조보강용 철구조물 유무에 따른 전산해석을 통한 열전달 해석과 이의 결과에 대한 검증을 위해 냉장고 내부 벽면의 온도를 측정하여 열손실 분석을 통한 냉장고 열손실을 개선하는 것을 목적으로 하였다. 본 연구를 통해 철구조물이 있는 경우에 이를 통하여 고온의 Hotline과 외부 공기의 열이 잘 전달되어서 냉장고의 열손실에 크게 영향을 미치는 것을 알 수 있었으며 이를 제거하면 냉장고 열손실이 24.8% 감소하여 철구조물을 제거하는 것이 냉장고 열손실 설계 개선을 크게 향상시킴을 알 수 있었다.

자연대류와 강제대류에서 펠티에 소자를 이용한 내부터널 구조를 가지는 히트싱크에 관한 연구 (A Study on the Heat Sink with internal structure using Peltier Module In the Natural and Forced Convection)

  • 이민;김태완
    • 한국산학기술학회논문지
    • /
    • 제15권7호
    • /
    • pp.4072-4080
    • /
    • 2014
  • 펠티에 소자는 전자부품이나 장비에서 발생하는 열을 냉각하기 위한 방법으로 많이 사용되고, 히트싱크는 이러한 열을 외부로 방출하기 위한 방법으로 많이 사용되고 있다. 본 연구에서는 내부터널의 형상을 가지는 히트싱크에 대한 냉각 및 히팅성능을 자연대류와 강제대류 상태에서 열전달 특성에 대하여 고찰하였다. 또한, 시간에 따른 히트싱크의 열전달 특성 및 온도분포의 변화에 따른 실험을 수행하였고, 자연대류와 강제대류에 따른 히트싱크의 열전달 특성, 온도분포의 변화를 실험을 통해 비교 연구 하였다. 냉각 실험에서 A형상 및 B형상 냉각 핀 히트싱크는 자연대류보다는 강제대류에서 온도가 더 감소하는 것을 알 수가 있었고, 강제대류와 자연대류에서 A, B형상 모두 $-15^{\circ}C$까지 떨어지는 것을 알 수 있었다. 전압이 증가 할수록 강제대류와 자연대류 상태에서 A, B형상 냉각 핀 히트싱크 모두 온도가 감소하였다. 히팅실험에서 A형상 및 B형상 냉각 핀 히트싱크는 자연대류보다는 강제대류에서 온도가 더 증가하는 것을 알 수가 있었고, 강제대류와 자연대류에서 전압이 13V일 때, A형상 냉각 핀 히트싱크는 전압이 $150^{\circ}C$, 강제대류에서 B형상 냉각 핀 히트싱크는 $145^{\circ}C$까지 증가하였다. 전압이 증가할수록 강제대류와 자연대류 상태에서 A, B형상 냉각 핀 히트싱크 모두 온도가 증가하였다.

기-액 상변화 열전달식 고온 히터 플레이트의 작동 특성과 성능에 관한 연구 (A Study on the Heat Transfer Characteristics and Performance of the High Temperature Range Heater Plate Using Liquid-Vapor Phase Change Heat Transfer)

  • 강환국;임광빈
    • 한국표면공학회지
    • /
    • 제46권6호
    • /
    • pp.283-289
    • /
    • 2013
  • The experimental study for the temperature uniformity on the wafer using liquid-vapor phase heat transfer mechanism is performed. For the experiment, the heater plate which is consist of stainless steel container, working fluid and electrical heater is designed, manufactured and tested at the range of 600 to $850^{\circ}C$. The results showed that the phase change type heater plate was much more uniform and stable temperature on the heater plate surface and wafer than the uniform heat flux type heater plate at the atmospheric condition. Also, the results of 300 mm outer diameter of heater plate showed that the same temperature uniformity compared with 230 mm.

電氣加熱式 模擬燃料棒 다발에서의 再冠水 熱傳達 硏究 (A Study of Reflood Heat Transfer in Electrically-Heated Fuel Rod Bundle)

  • 정문기;박종석;이영환
    • 대한기계학회논문집
    • /
    • 제10권1호
    • /
    • pp.7-14
    • /
    • 1986
  • 본 연구에서는 가압경수형 원자로심을 모의하는 3*3배열로 된 모의연료 봉다발의 실험장치를 이용하여 재완수과정의 유동특성과 열전달특성을 파악하였으며, 재완수과정중 연료봉의 온도거동을 예측하는 REFLUX코드를 최근 개발된 연구자료를 토대로 수정하여 본실험결과와 비교하였다.