• Title/Summary/Keyword: Heat Pump System

Search Result 1,121, Processing Time 0.026 seconds

Capacity Modulation of a Multi-Type Heat Pump System Using PID Control (PID 제어를 이용한 멀티형 열펌프의 용량조절)

  • 정대성;김민성;김민수;이원용
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.5
    • /
    • pp.446-475
    • /
    • 2000
  • Performance of a water-to-water multi-type heat pump system using R22 has been experimentally investigated. Total refrigerant flow rate was adjusted with a variable speed compressor and the refrigerant flow rate for two indoor units were controlled by electronic expansion valves. Evaporator outlet pressure of refrigerant and indoor unit outlet temperatures of secondary fluid were selected as controlled variables. Experiments were carried out for both cooling and heating modes using PID control method. Results show that the multi-type heat pump system can be adequately controlled by keeping control gains at certain levels for various operating conditions.

  • PDF

Simulation of the Second Kind LiBr - H2O Absorption Heat Pump (2종 LiBr - H2O 흡수식 열펌프의 시뮬레이션)

  • Huh, J.Y.;Choi, Y.D.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.1 no.2
    • /
    • pp.146-161
    • /
    • 1989
  • The second kind LiBr-$H_2O$ absorption heat pump system was simulated and the performances of it were predicted. The elements of heat pump system, evaporator, absorber and generator were analysed by solving the energy balance equations and concentration equations which describe the reactions between working fluids. The results show that the temperature gain of absorber is affected considerably by the operating conditions of heat pump system, on the other hand, COP is little affected by them.

  • PDF

A study of frequency control of an inverter heat pump for indoor air temperature adjustment (실내온도조절을 위한 인버터 열펌프의 주파수 제어에 관한 연구)

  • Park, Yun-Cheol;Min, Man-Gi
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.10
    • /
    • pp.1262-1272
    • /
    • 1997
  • An experimental study on the frequency control of an inverter heat pump to get the desired indoor room temperature has been conducted for the performance characteristics during the steady, 4, 8, and 16 step frequency operations. The heat pump model used in this study was operated to meet the experimental conditions of ASHRAE standard. The performance of the system was tested by measuring the temperature and pressure of the refrigerant, and cooling capacity, power consumption, etc. of the system. As the controlling frequency steps increased, the running time of the compressor increased as well as the electric consumption of the system and the cooling energy due to the wall heating load. However, the average cooling COP was improved.

Development of Heat Pump System for the Greenhouse Heating

  • Song, Hyun-Kap;Ryou, Young-Sun;Park, Jong-Kil
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 1996.06c
    • /
    • pp.1101-1116
    • /
    • 1996
  • It is desirable to use the renewable energy for the greenhouse heating in winter season, it makes possible not only to save fossil fuel and conserve green farm environment but also to promote the quality of agricultural products and reduce the agricultural production cost. In this study the heat pump system was developed to use the natural energy as thermal energy resource for the thermal environment control of the greenhouse.

  • PDF

Indoor Temperature Control of a Heat Pump Based on Model Predictive Control Considering Energy Efficiency (에너지효율을 고려한 모델예측제어에 기초한 열펌프의 실내온도 제어)

  • 조항철;변경석;송재복;장효환;최영돈
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.3
    • /
    • pp.200-208
    • /
    • 2001
  • In indoor temperature control of a heat pump, a reduction in energy consumption is very important. However, most control schemes for heat pumps have focused only on control performance such s settling time and steady-state error. In this paper, the model predictive control (MPC) which includes the energy-related variable in this cost function is proposed. By computing the control signal minimizing this cost function, the trade-off between energy reduction and temperature control performance can be obtained. Since the MPC required the process model, the dynamic mode of a heat pump is also obtained by the system identification technique. Performance of the proposed MPC considering energy efficiency is compared with the two other control schemes. It si shown that the proposed scheme can consume less energy thant hte others in achieving similar control performance.

  • PDF

Study on Performance of Heat Pump using a subcooled refrigerant (냉매과냉각에 의한 열펌프의 성능향상에 관한 연구)

  • 박승준
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2000.05a
    • /
    • pp.159-164
    • /
    • 2000
  • In this paper a new type refrigerant liquid subcooling system which adopts ice storage system is proposed. And the cycle characteristicso of a new system was investigated. Since this system subcools a refrigerant in the daytime using the ice storaged by electric power in the night it is high efficiency heat pump system which have the merit of ice storage system and possible to improve the performance of the heat pump. The running to storage the ie was carried out for 10 hours in the night and th evaporating temperature was set on $-5^{\circ}C.$ Subcooling operation stayed as 430^{\circ}C$ subcooling degree and perfomed till the water in the IST(Ice storage tank) was reached $12^{\circ}C$. The experimental result showed that a new system was superior to the existing refrigeration system generally. The total cooling capacity of a new system was about 11% higher than that of the existing refrigeration system. And the COP of a new system was improved by 22% compared to the existing refrigeration system.

  • PDF

Heating Performance of a Ground Source Heat Pump System through Actual Operation (지열원 히트펌프시스템의 실사용을 통한 난방성능연구)

  • Koo, Kyoung-Min;Jeong, Young-Man;Hwang, Yu-Jin;Lee, Jae-Keun;Jang, Se-Yong;Kim, In-Kyu;Jin, Sim-Won;Lee, Dong-Hyuk
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1341-1346
    • /
    • 2008
  • This paper presents the heating performance of a water-to-refrigerant type ground source heat pump system (GSHP) installed in a school building. The evaluation of the heating performance has been conducted under the actual operating conditions of GSHP system in the winter. Ten units with the capacity of 10 HP each were installed in the building. Also, a closed vertical typed-ground heat exchanger with 24 boreholes of 175 m in depth was constructed for the GSHP system. For analyzing the heating performance of the GSHP system, we monitored various operating conditions, including the outdoor temperature, the ground temperature, and the water temperature of inlet and outlet of the ground heat exchanger. Simultaneously, the heating capacity and the input power were evaluated for determining the heating performance of the GSHP system. The average heating coefficient of performance (COP) of the heat pump was found to be 5.1 at partial load of 46.9%, while the overall system COP was found to be 4.2.

  • PDF

Heating Performance of a Ground Source Heat Pump System through Actual Operation (지열원 히트펌프시스템의 실사용을 통한 난방성능연구)

  • Koo, Kyoung-Min;Jeong, Young-Man;Hwang, Yu-Jin;Lee, Jae-Keun;Jang, Se-Yong;Kim, In-Kyu;Jin, Sim-Won;Lee, Dong-Hyuk
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.788-793
    • /
    • 2008
  • This paper presents the heating performance of a water-to-refrigerant type ground source heat pump system (GSHP) installed in a school building. The evaluation of the heating performance has been conducted under the actual operating conditions of GSHP system in the winter. Ten units with the capacity of 10 HP each were installed in the building. Also, a closed vertical typed-ground heat exchanger with 24 boreholes of 175 m in depth was constructed for the GSHP system. For analyzing the heating performance of the GSHP system, we monitored various operating conditions, including the outdoor temperature, the ground temperature, and the water temperature of inlet and outlet of the ground heat exchanger. Simultaneously, the heating capacity and the input power were evaluated for determining the heating performance of the GSHP system. The average heating coefficient of performance (COP) of the heat pump was found to be 5.1 at partial load of 46.9%, while the overall system COP was found to be 4.2.

  • PDF

A Study on the Performance of Solar Heat, Pump Cycle System for $CH_2F_2$, $CF_3CHF_2$ and $CF_3CH_2F$( I ) ($CH_2F_2-CF_3CH_2F-CF_3CHF_2$계 냉매적용 태양열 열펌프시스템 성능 연구( I ))

  • Lee, Soon-Bok;Jung, Hyun-Chai;Bae, Chun-Woo;Sun, Kyung-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.2
    • /
    • pp.71-79
    • /
    • 2003
  • The goal of this paper is to measure and compare the performance of solar heat pump for refrigerants. To accomplish the goal, solar heat pump with aluminum roll bond type evaporator and indoor heat exchanged(condenser) was built. The test results showed that the COP and heating capacity of HFC-32/125/134a(23/25/52 wt%, $CH_2F_2/CF_3CHF_2/CF_3CH_2F$) were higher than those of HCFC-22$(CHClF_2)$. A study proved that best conditions to use heating system that is about $40m^2$ and $80m^2$. The COP range of the whole system was from 4 to 6 according to the solar collector's area variation. Hydrochlo-rofluorocarbon HCFC-22$(CHClF_2)$ is included in the compound to be controlled. HFC-32/125/134a(23/25/52 wt%, $CH_2F_2/CF_3CHF_2/CF_3CH_2F$) is the most suitable replacement HCFC-22$(CHClF_2)$ in solar heat pump application. The solar heat pump system was designed to show the best efficiency that the room temperature make $18\sim20^{\circ}C$ and $23\sim25^{\circ}C$ in Seoul during the fall season.

Performance Evaluation of Ground Source Heat Pump System Utilizing Energy Pile in Apartment (공동주택에서 에너지 파일을 이용한 지열히트펌프 시스템의 성능 분석)

  • Lee, Jin-Uk;Kim, Taeyeon;Leigh, Seung-Bok
    • KIEAE Journal
    • /
    • v.12 no.4
    • /
    • pp.41-46
    • /
    • 2012
  • In Korea, Apartment houses recently occupy over 80% of all buildings. Ground source system has to be designed to consider feature of apartment house. Most apartment houses use PHC pile to get a bearing power of the soil. Therefore, the purpose of this study is to evaluate performance of ground source heat pump system utilizing energy pile under apartment. Object of experiment is low-energy experiment apartment in Song-do and Energy Pile are applied to 80%, 100% energy reduction model for heat-source. First, performance evaluation of Energy Pile geothermal system was done during summer season. As a result, The COP(coefficient of performance) about geothermal heatpump was approximately 5-6 while cooling. In winter season, Long experiment was performed because it was very important to evaluate ground condition for long time. During heating experiment, Indoor room set temperature was $20^{\circ}C$ and kept constant by heating. Coefficient of performance for heat pump and overall system was calculated. It was 3.5-4.5 for COP and 2.5-3.7 for system COP.