• 제목/요약/키워드: Heat Load Analysis

검색결과 629건 처리시간 0.033초

육상 수조식 양식장의 해수 열원 히트펌프 시스템 적용을 위한 열부하 분석 (Thermal load analysis of tank culture system for applying seawater source heat pump)

  • 윤민기;김태훈;정석권
    • 수산해양기술연구
    • /
    • 제59권2호
    • /
    • pp.155-163
    • /
    • 2023
  • This study deals with the maximum thermal load analysis and optimal capacity determination method of tank culture system for applying seawater source heat pump to save energy and realize zero energy. The location of the fish farm was divided into four sea areas, and the heat load in summer and winter was analyzed, respectively. In addition, two representative methods, the flow-through aquaculture system and the recirculation aquaculture system were reviewed as water treatment methods for fish farms. In addition, the concept of the exchange rate was introduced to obtain the maximum heat load of the fish farms. Finally, power consumption for heat pumps was analyzed in the view point of sea areas, tank capacity, and exchange rate based on the calculated maximum thermal load.

축력비 조건에 따른 철근콘크리트기둥의 내화성능에 관한 연구 (A Study on the Fire Resistance Performance of Reinforced Concrete Columns according to Axial Load Ratio)

  • 황규재;조범연;여인환
    • 한국화재소방학회논문지
    • /
    • 제27권6호
    • /
    • pp.26-31
    • /
    • 2013
  • 본 연구의 목적은 성능적 내화설계를 기반으로 한 철근콘크리트 기둥의 내화성능 평가를 최종 목표로 철근콘크리트 기둥의 열전달 해석을 통한 온도분포와 재하가열실험을 통한 수축량으로 적정 축력비를 도출하여 성능설계를 위한 기초 자료로 활용하고자 하는데 있다. 편심이 전혀 없는 순수축력을 기준으로 축력비 0.30, 0.35, 0.40, 0.47을 재하한 결과, 0.40 이상의 축력비를 확보하여야 내화성능을 만족할 수 있다고 판단하였다.

유동 불균일이 전열관 튜브에 미치는 영향 (Influence on heat transfer due to uneven flow)

  • 정재헌;송정일
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.273-279
    • /
    • 2008
  • The purpose of this study is not only to evaluate thermal performance but also to find the stress behavior of heat transfer tubes under the part load operation in Heat Recovery Steam Generator. Flow analysis was performed to know the behavior of exhaust gas from gas turbine and thermal performance was calculated using distribution of hot exhaust velocity. In addition, tubes temperature during operation were gathered from actual plant to verify the uneven flow distribution under part load operation. Stress analysis was performed using tubes temperature data gathered from actual plant under both part and full load operations to know the stress behavior of tubes.

  • PDF

지열을 이용한 외기부하저감시스템의 외기온도와 출구온도의 상관관계 분석 (A Study on the Correlation between Outdoor Air and Outlet Air Temperature in a Fresh Air Load Reduction System by Using Geothermal Energy)

  • 손원득;박경순
    • 설비공학논문집
    • /
    • 제22권9호
    • /
    • pp.620-627
    • /
    • 2010
  • This paper presents a feasibility study of a fresh air load reduction system by using an underground double floor space. The fresh air is introduced into the double slab space and passes through the opening bored into the footing beam. The air is cooled by the heat exchange with the inside surface of the double slab space in summer, and heated in winter. This system not only reduces sensible heat load of the fresh air by heat exchange with earth but also reduces latent heat load of the fresh air by ad/de-sorption of underground double slab concrete. In this paper, we investigated the correlation between outdoor air temperature and outlet air temperature in the system. In conclusion, from the results of the high correlation we proposed a equation of regression for the outlet air temperature in the system by using linear regression analysis.

지열 이용 외기부하 저감시스템의 냉각 및 가열효과 예측 간이추정법에 관한 연구 (A Study on the Simplified Presumption Method for the Prediction of Cooling and Heating Performance in a Fresh Air Load Reduction System by Using Geothermal Energy)

  • 손원득;최영식
    • 한국산업융합학회 논문집
    • /
    • 제13권3호
    • /
    • pp.169-181
    • /
    • 2010
  • This paper presents a feasibility study of a fresh air load reduction system by using an underground double floor space. The fresh air is introduced into the double slab space and passes through the opening bored into the footing beam. The air is cooled by the heat exchange with the inside surface of the double slab space in summer, and heated in winter. This system not only reduces sensible heat load of the fresh air by heat exchange with earth but also reduces latent heat load of the fresh air by ad/de-sorption of underground double slab concrete. In this paper, we proposed a simplified presumption method for the prediction of cooling and heating performance in the system. In conclusion the proposed method has been verified by comparing with the calculated value of the numerical analysis model by using nonlinear two-dimension hygroscopic question.

  • PDF

변화하는 밀도와 비열을 고려한 고속 저어널 베어링의 열유체 윤활해석 (Thermohydrodynamic Lubrication Analysis of High Speed Journal Bearing Considering Variable Density and Specific Heat)

  • 전상명;장시열
    • Tribology and Lubricants
    • /
    • 제17권4호
    • /
    • pp.297-306
    • /
    • 2001
  • Under the condition of variable density and specific heat, maximum pressure, maximum temperature, bearing load, friction and side leakage in high-speed journal bearing operation are examined within some degree of Journal misalignment. The results are compared with the calculation results under the conditions of constant density and specific heat, and variable density and constant specific heat. It is found that the condition of variable density and specific heat play important roles in determining friction and load of Journal bearing at high speed operation.

부하 대응 제어방식을 적용한 축열식 히트펌프시스템의 성능 해석 (A Performance Analysis on a Heat pump with Thermal Storage Adopting Load Response Control Method)

  • 김동준;강병하;장영수
    • 설비공학논문집
    • /
    • 제30권3호
    • /
    • pp.130-142
    • /
    • 2018
  • We use heat pumps with thermal storage system to reduce peak usage of electric power during winters and summers. A heat pump stores thermal energy in a thermal storage tank during the night, to meet load requirements during the day. This system stabilizes the supply and demand of electric power; moreover by utilizing the inexpensive midnight electric power, thus making it cost effective. In this study, we propose a system wherein the thermal storage tank and heat pump are modeled using the TRNSYS, whereas the control simulations are performed by (i) conventional control methods (i.e., thermal storage priority method and heat pump priority method); (ii) region control method, which operates at the optimal part load ratio of the heat pump; (iii) load response control method, which minimizes operating cost responding to load; and (iv) dynamic programming method, which runs the system by following the minimum cost path. We observed that the electricity cost using the region control method, load response control approach, and dynamic programing method was lower compared to using conventional control techniques. According to the annual simulation results, the electricity cost utilizing the load response control method is 43% and 4.4% lower than those obtained by the conventional techniques. We can note that the result related to the power cost was similar to that obtained by the dynamic programming method based on the load prediction. We can, therefore, conclude that the load response control method turned out to be more advantageous when compared to the conventional techniques regarding power consumption and electricity costs.

노후 학교건물의 창호 교체에 따른 부하분석 (Analysis of Heating and Cooling Load Profile According to the Window Retrofit in an Old School Building)

  • 이예지;김주욱;송두삼
    • 설비공학논문집
    • /
    • 제29권9호
    • /
    • pp.455-462
    • /
    • 2017
  • The purpose of this study is to analyze heating and cooling load variation due to envelope retrofits in an old school building. In a previous study, envelope retrofit of an old school building resulted in annual energy consumption reduction. However, cooling energy consumption increased with the envelope retrofit. This is because of high internal heat generation rates in school buildings and internal heat cannot escape through windows or walls when the envelope's thermal performance improves. To clarify this assumption, thermal performance changes due to envelope retrofits were analyzed by simulation. Results revealed indoor temperature and inner window surface temperature increased with high insulation level of windows. Indoor heat loss through windows by conduction, convection and radiation decreased and resulted in an increase of cooling load in an old school building. From results of this study, energy saving impact of envelope retrofits in an old school building may not be significant because of high internal heat gain level in school buildings. In case of replacing windows in school buildings, local climate and internal heat gain level should be considered.

지역난방 사용자 구성비에 따른 열소비 패턴 분석 (Heat Consumption Pattern Analysis by the Component Ratio of District Heating Users)

  • 이훈;이민경;김래현
    • 에너지공학
    • /
    • 제22권2호
    • /
    • pp.211-225
    • /
    • 2013
  • 본 연구에서는 서로 다른 위도의 도시 유형별로 주택과 건물 구성비를 가진 3지역을 선정하여 대상 지역별로 2008년 1년간(1.1~12.31)의 실제 운전실적을 이용하여 지역난방 사용자의 일일 및 연간 열소비 패턴을 분석하고, 지역별 상호 차이점을 파악하기 위하여 주택과 건물의 열소비 패턴을 비교 분석하였다. 특히 본 연구에서는 실제 주택 및 건물 지역난방 사용자가 사용한 열소비 패턴을 매시간대별로 파악하고, 연결 열부하(난방면적 ${\times}$ 단위열부하 : 시설용량과 지역난방 배관망의 설계기준이 되는 열부하로 난방면적에 용도별 단위열부하를 곱하여 산출[Gcal/h])와의 관계를 분석하여 일일, 연간 및 최대 부하율 결과값을 도출함으로써 주택 및 건물 지역난방 사용자 비율에 따른 최적의 열원시설 용량산정이 가능케 하고 수요개발(해당 시설용량으로 열공급이 가능한 지역난방 사용자의 범위로 각 사용자기계실의 연결열부하 합과 같음.)단계에서의 정확한 방향을 제시할 수 있는 근거를 도출하였다.

창호의 단열성능에 따른 공동주택 냉난방 부하량 변화 (The Change of Heating and Cooling Load according to the Thermal Insulation Performance of Window for an Apartment House)

  • 송수빈;김영탁;윤성환
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.853-856
    • /
    • 2008
  • Windows have an great effect on annual building load because windows are the weakest parts of building envelope thermally. To reduce the consumption of building energy, the thermal performance of window has to be improved in first place. Therefore this research aims to make a quantitative analysis of the heating and cooling load according to the window thermal performance using the heat load simulation program. As a result of the simulation, annual heat load is down 38% according to the decrease of U-value of window, 1.00 W/$m^2K$. and annual heat load is up 10% according to the decrease of shading coefficient, 0.20. The annual load of the window with Low-E glass is 15% lower than the window with pair glass.

  • PDF