Computational Analysis of the Heat/Moisture Characteristics and Heat Load of Underground Structures (열.수분 동시이동 모델을 이용한 지하구조물 및 주변지반의 열수분성상 예측에 관한 연구)

  • Park, Kyung-Soon;Son, Won-Tug
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.901-905
    • /
    • 2008
  • This study was conducted to clarify the heat load characteristics and heat and moisture behavior of underground structures. The authors achieved this by carrying out a numerical analysis using simple heat diffusion and simultaneous heat and moisture transfer equations based on measurement data. This paper presents the results of a numerical analysis on the heat load characteristics and heat and moisture behavior of an underground basement and its surrounding ground under a condition of internal heat generation. The authors found it difficult to predict the heat behavior and heat load of the underground basement by simple heat diffusion alone. Accurate prediction of the thermal environment and heat load requires careful consideration of the influences of moisture and precipitation

  • PDF

Comparative Analysis of Energy Performance of Hydrothermal, Geothermal Source and Hybrid Heat Pump System According to Internal Heat Load for Office, School and Smart Farm (건축물 용도별 내부 발열부하에 따른 수열원, 지열원 및 하이브리드 히트펌프 시스템의 에너지 성능 비교 분석)

  • Park, Sihun;Min, Joonki
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.18 no.3
    • /
    • pp.19-30
    • /
    • 2022
  • In this study, comparative analysis of energy performance in Taebaek city, a test area, by applying hydrothermal, geothermal source and hybrid heat pump system to office, school and smart farms with different internal heat loads. The conclusion is as follows. In the load characteristics by use of buildings, it was found that office had a large cooling load compared to heating load, school had a large heating load compared to cooling load, and smart farm had only cooling load year-round. Performance analysis of the heat pump system in office shows that the cooling COP of the hydrothermal source is 5.12% and the heating COP is 3.22% lower based on the geothermal source, the cooling COP of the hybrid is 0.41% higher, and the heating COP is the difference in performance appeared sparsely. The performance analysis of the heat pump system in school showed that the cooling COP of the hydrothermal source was 10.44% and the heating COP 3.22% lower based on the geothermal source, and the performance difference between the hybrid cooling and heating COP was insignificant. Heat pump system performance analysis in smart farm only occurred with cooling load. Based on geothermal sources, the cooling COP of the hydrothermal source was 46% and the cooling COP of the hybrid was 19.65%, respectively.

Analysis on short-term decay heat after shutdown during load-follow operation with seasonal and daily scenarios

  • Hwang, Dae Hee;Kim, Yonghee
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3878-3887
    • /
    • 2022
  • For the future energy-mix policy for carbon neutrality, demand for the capability of load-follow operation has emerged in nuclear power plants in order to accommodate the intermittency of renewable energy. The short-term decay heat analysis is also required to evaluate the decay heat level varied by the power level change during the load-follow operation, which is a very important parameter in terms of short-term decay heat removal during a grace time. In this study, the short-term decay heat level for 10 days after the shutdown was evaluated for both seasonal and daily load-follow cases. Additionally, the nuclide-wise contribution to the accumulated decay heat for 10 days was analyzed for further understanding of the short-term decay heat behavior. The result showed that in the seasonal case, the decay heat level was mainly determined by the power level right before the shutdown and the amount of each nuclide was varied with the power variation due to the long variation interval of 90 days. Whereas, in the daily case, the decay heat level was strongly impacted by the average power level during operation and meaningful mass variations for those nuclides were not observed due to the short variation interval of 0.5 days.

Analysis on the Heat load Pattern According to Ratio of the Heat Consumers in District Heating (지역난방 열사용자 비율별 열부하 패턴변화 분석: 공동주택과 건물)

  • Lee, Hoon;Lee, Yoon-Pyo;Kim, Lae-Hyun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.3
    • /
    • pp.123-129
    • /
    • 2010
  • The district heating users can be generally classified into two groups such as apartments and buildings. In consideration that the time zone of the maximum heat load for apartments is different from those of buildings during a day, the maximum heat supply range is presented. In case of the investigated area, the maximum heat supply is occurred at the ratio between apartments and buildings that is 65%:35%. Thus the heat supply range is increased as much as 15% if the time zone when the maximum heat load is occurred is considered.

A Preliminary Study on the Analysis Model of Energy System based on Fuel Cell for Apartment Houses (연료전지기반 공동주택 에너지시스템 분석모델에 관한 기초연구)

  • Lee, Hong-Cheol;Hwang, In-Ju
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.396-401
    • /
    • 2003
  • In the present study, preliminary investigation were carried out by analysis of energy system(heat and electricity) based on phosphoric acid fuel-cell of 50 kW for eco-apartment houses. Analysis model were consisted of fuel cell energy system, secondary energy unit and residential building of 5 stories with 20 and 40 households. And the investigation results reviewed under load pattern of heat and electric power of the apartment houses. The results showed mismatch between the needed heat load pattern and output of fuel cell energy system. The mismatch rate were assessed about 10-180% of heat load for apartment houses with season. We found that secondary energy unit are needed in order to supply insufficient heat.

  • PDF

Thermal Design and Heat Load Measurement of PSICS (적외선 우주망원경 냉각시스템 열설계 및 열침입량 측정)

  • Yang H. S.;Kim D. L.;Lee B. S.;Choi Y. S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.3
    • /
    • pp.43-46
    • /
    • 2005
  • A Protomodel Space Infrared Cryogenic System (PSICS) cooled by a stirling cryocooler was designed. The PSICS has an IR sensor inside a cold box which is cooled by a stilting cryocooler with refrigeration capacity of 500mw at 80K in a vacuum vessel. It is important to minimize heat load for reducing background thermal noise. In order to design the cryogenic system of low heat load and to reduce heat load, we did several numerical analyses and tested using boil-off calorimetry with liquid nitrogen to measure the heat leak of the system. In this paper, we present the results obtained by thermal analysis and heat load measurement for designing the PSICS.

Analysis of Design and Part Load Performance for gas Turbine Cogeneration Systems (가스터빈 열병합발전 시스템의 설계점 설정 및 부분부하 성능해석)

  • 김동섭;노승탁
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.8
    • /
    • pp.2167-2176
    • /
    • 1994
  • This paper presents some useful design criteria for the turbine cogeneration system through both the design and off-design analysis. Comparative analysis of the part load performance is carried out for several gas turbines which have different design parameters represented by the turbine inlet temperature and pressure ratio. It is shown that the variation in part load efficiency considerably depends on the design parameter. The off-design operation of the heat recovery steam generator is simulated by introducing adequate assumptions for the heat transfer process. It is turned out that the design parameters of heat recovery steam generator should be determined by considering the favorable operation at the off-design conditions.

Exergy Analysis of On/Off Controlled Heat Pump

  • Jang, Ki-Tae;Nam, Kwan-Woo;Jeong, Sang-Kwon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.7
    • /
    • pp.22-32
    • /
    • 1999
  • A multi-type heat pump controls the mass flow rate of the working fluid to cope with variable heat loads when it is under dynamic load condition. This paper describes the exergy analysis associated with the unsteady response of a heat pump. First, a basic heat pump cycle is examined at a steady state to show the general trends of exergy variations in each process of the cycle. Entropy generation issue for the heat exchangers is discussed to optimize the heat pump cycle. Secondly, the performance of the inverter-driven heat pump is compared to that of the conventional one when the heat load is variable. Thirdly, the exergy destruction rate of the heat pump with On/Off operation is calculated by simulating the thermodynamic states of the working fluid in the condenser and the evaporator. The inefficiency of On/Off operation during the transient period is quantitatively described by the exergy analysis.

  • PDF

Exergy analysis of heat pump in consideration of its dynamic response (동특성을 고려한 열펌프의 엑서지 해석)

  • 장기태;남관우;정상권
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.2
    • /
    • pp.155-164
    • /
    • 1998
  • A multi-type heat pump controls the mass flow rate of the working fluid to cope with variable heat loads when it is under dynamic load condition. This paper describes the exergy analysis associated with the dynamic response of heat pump. First, a basic heat pump cycle is examined at steady state to show the general trends of exergy changes in each process of the cycle. Entropy generation issue in the exchangers is discussed to optimize the heat pump cycle. Second, the performance of the inverter-driven heat pump is compared to that of the conventional one when the heat load is variable. Third, the exergy destruction rate associated with the ON/OFF operations of the heat pump is calculated by simulating the thermodynamic states of the condenser and the evaporator. The inefficiency of the ON/OFF operation during the transient period is quantitatively revealed by the exergy analysis.

  • PDF

Thermal load analysis of tank culture system for applying seawater source heat pump (육상 수조식 양식장의 해수 열원 히트펌프 시스템 적용을 위한 열부하 분석)

  • Min-Gi YOON;Tae-Hoon KIM;Seok-Kwon JEONG
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.59 no.2
    • /
    • pp.155-163
    • /
    • 2023
  • This study deals with the maximum thermal load analysis and optimal capacity determination method of tank culture system for applying seawater source heat pump to save energy and realize zero energy. The location of the fish farm was divided into four sea areas, and the heat load in summer and winter was analyzed, respectively. In addition, two representative methods, the flow-through aquaculture system and the recirculation aquaculture system were reviewed as water treatment methods for fish farms. In addition, the concept of the exchange rate was introduced to obtain the maximum heat load of the fish farms. Finally, power consumption for heat pumps was analyzed in the view point of sea areas, tank capacity, and exchange rate based on the calculated maximum thermal load.