• Title/Summary/Keyword: Heat Insulation

Search Result 887, Processing Time 0.03 seconds

Analysis of the Maximum Heat Release Rate in Accordance with the Test Method of the Flame Retardant Performance for Pipe Insulation (배관용 보온재의 난연 성능 시험방법에 따른 최대 발열량 분석)

  • You, Woo Jun;Park, Jung Wook;Sin, Yeon Je;Park, Hyeong Gyu;Lim, Ohk Kun
    • Fire Science and Engineering
    • /
    • v.34 no.1
    • /
    • pp.18-25
    • /
    • 2020
  • In this study, the heat release rate of pipe insulation is analyzed by considering the installation status in accordance with the standards ISO 20632 and NFPA 274. The flame retardation rate was evaluated for six types of test samples: polyethylene foam covered with beaten silver (PE(S)), PE foam tapped (PE(N)), elastomeric closed cell thermal insulation (rubber), Japanese PE foam (PE(J)), Japanese polyurethane foam (PU(J)), and Japanese styro form (ST(J)) by EN 13501-1 and fire growth curve. The results show that PU(J), PE(J), and PE(N) were Class E and ultra-fast, NFPA 274 test standards for Class D and Fast, and PE(S) by ISO 20632 were Class C and Slow, and Rubber and ST(J) were Classes and Low. However, the changes in the time-averaged maximum heat release rate for each test standard (ISO 20632 and NFPA 274) to evaluate the flame retardation rate differed among identical materials. This means that the fundamental study is necessary to analyze the more accurate reasons.

Development of Semi-basement Type Greenhouse Model for Energy Saving

  • Kim, Seoung Hee;Joen, Jong Gil;Kwon, Jin Kyeong;Kim, Hyung Kweon
    • Journal of Biosystems Engineering
    • /
    • v.41 no.4
    • /
    • pp.328-336
    • /
    • 2016
  • Purpose: The heat culture areas of greenhouses have been continuously increasing. In the face of international oil price fluctuations, development of energy saving technologies is becoming essential. To save energy, auxiliary heat source and thermal insulation technologies are being developed, but they lack cost-efficiency. The present study was conducted to save energy by developing a conceptually new semi-basement type greenhouse. Methods: A semi-basement type greenhouse, was designed and constructed in the form of a three quarter greenhouse as a basic structure, which is an advantageous structure to inflow sunlight. To evaluate the performance of the developed greenhouse, a similar structured general greenhouse was installed as a control plot, and heating tests were conducted under the same crop growth conditions. Results: Although shadows appeared during the winter in the semi-basement type greenhouse due to the underground drop, the results of crop growth tests indicated that there were no differences in crop growth and development between the semi-basement type greenhouse and the control greenhouse, indicating that the shadows did not affect the crop up to the height of the crop growing point. The amount of fuel used for heating from January to March was almost the same between the two greenhouses for tests. The heating load coefficients of the experimental greenhouses were calculated as $3.1kcal/m^2{\cdot}^{\circ}C{\cdot}h$ for the semi-basement type greenhouse and $2.9kcal/m^2{\cdot}^{\circ}C{\cdot}h$ for the control greenhouse. Since the value is lower than the double layer PE (polyethylene) film greenhouse value of $3.5kcal/m^2{\cdot}^{\circ}C{\cdot}h$ from a previous study, Tthe semi-basement type greenhouse seemed to have energy saving effects. Conclusions: The semi-basement type greenhouse could be operated with the same fuel consumption as general greenhouses, even though its underground portion resulted in a larger volume, indicating positive effects on energy saving and space utilization. It was identified that the heat losses could be reduced by installing a thermal curtain of multi-layered materials for heat insulation inside the greenhouse for the cultivation of horticultural products by installing thermal curtain of multi-layered materials for heat insulation inside the greenhouse, it was identified that the heat losses could be reduced.

Electrical Properties of XLPE Cable Termination using Thermal Contraction Type (열수축형을 이용한 XLPE케이블 종단부의 전기적 특성)

  • Baek, Seung-Myeong;Choi, Jae-Hyeong;Choi, Jin-Wook;Kim, Sang-Hyun;Kim, Yeong-Seok;Kim, Seon-Gu
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.395-396
    • /
    • 2009
  • For investigation of electrical properties of XLPE cable termination, we prepared a thermal contraction type kit and 6.6kV XLPE cable. The cable termination that have simulated defect by badness construction have been manufactured and their insulation characteristics such as ac and impulse withstand test have been measured. The influence of defects such as thickness decrease and heating time have been studied. When thickness decreased 1mm, the decreased of AC breakdown voltage value is not very distinctive. However, when thickness decreased 2mm, the insulation AC breakdown voltage value was very low down to 43kV. When approved heat for 300s than 60s, AC Breakdown voltage value appeared high. And also, after insulation breakdown took place, the sample was observed before and after disassembly, and the insulation breakdown hole was observed by means of optical microscope.

  • PDF

Study on Reliability of Water Absorption Diagnosis through Precise Water Absorption Test

  • Kim, Hee-Soo;Bae, Yong-Chae;Kim, Hee-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.5
    • /
    • pp.772-777
    • /
    • 2012
  • Accidents caused by water absorption in water-cooled generator stator windings often occur all over the world. The absorption into the insulator of the coolant, which is used to cool down the heat generated by stator windings during operation, leads to the deterioration of dielectric strength, and insulation breakdown. An insulation breakdown may cause not only an enormous economic loss but also a very serious grid accident that would compromise stable supply of electric power. More than 50 % of domestic generators have been in operation for more than 15 years, and water absorption tests performed on 50 water-cooled generator stator windings during a five-year planned preventive maintenance period beginning in 2006 identified water absorption problems in 10 of them, all of which required repair. Because the existing water absorption test detects this problem by utilizing stochastic methods after measuring the capacitances at the final positions of insulation breakdown, its accuracy is limited. This study demonstrates that water absorption can be more accurately diagnosed by utilizing method along with a more precise one.

The Basic Insulation Characteristics of Solid-Nitrogen for Cryocooling of HTS Systems (고온초전도 시스템 냉각용 고화질소의 기초 절연 특성)

  • Choi, Jae-Hyeong;Choi, Jin-Wook;Lee, Hai-Gun;Song, Jung-Bin;Kim, Hae-Jong;Seong, Ki-Chul;Kim, Sang-Hyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.1
    • /
    • pp.132-136
    • /
    • 2009
  • Recently, for improvement of the magnetic field of high temperature superconductor (HTS) apparatus, many studies investigating on operating in the range of $20{\sim}65\;K$ with liquid helium or the conducting method using cryocooler are actively reviewed. Also, the cooling method using solid nitrogen as cryogen is being suggested. Since the nitrogen has very large specific heat in solid state, it is expected that it can be operated for a long time without a continuous supply of cooling energy. However, there are still insufficient data on the characteristics of solid nitrogen such as thermodynamic properties and liquid-solid phase change. Especially, there was almost no study done on the electrical insulation properties of solid nitrogen so far. In this study, solid nitrogen to find the electrical characteristics was made by using cryocooler and cryostat, and investigated the flashover discharge and breakdown. The results of this study will be useful as a basic data for electrical insulation design of the HTS system using solid nitrogen as cryogen.

Friction Characteristics for Construction thermal insulation manufacturing system Breaker (건축단열재 생산시스템 브레이커 마찰특성)

  • Son, Jae-Hwan;Kang, Hae-Dong;Noh, Kyoo-Ik;Suk, Jang-Geun;Choi, Won-Sik
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.6
    • /
    • pp.61-65
    • /
    • 2014
  • Construction heat insulating material for construction is used in large amounts in industry. In the manufacturing process of this insulation material, a thermal insulation material is completed while a polymer in a liquid state passes through Hall breaker. At this time, the quality and form of a product are determined by a hole in the breaker according to the oil pressure of the fluid and the change of the flow velocity. The friction wear action with regard to partner movement between the two levels of quality of materials affects the performance and the lifetimes of machine parts. In this study of a friction test, SM45C, which is a material used to create brake holes, was used. PVC was used to create the specimen. Moreover, an experiment divided a lubricous state and an unlubricated condition. The resulting value over the load of a pin, the revolving speed of a disk, and the standby state of an experimental result disk could be acquired.

Design of Class E Insulation Induction Motor (E종 절연 유도 전동기의 설계)

  • Sung Won Lee
    • 전기의세계
    • /
    • v.16 no.2
    • /
    • pp.1-8
    • /
    • 1967
  • From the discovery of Alago's disk, a number of trials and efforts have been concentrated on a small-sized and light-weighted induction motor. They have devoted themseleves, however, mainly to a improvement of cooling effect, a proper weight-distribution of copper and iron and desirable number of slots. In consequence, such an effort restricted only to the field of design, has resulted in unsatisfactory developments in the insulating materials consisting of the main parts of an induction motor. The quality of fibre and paper which are used as class-A insulation materials with their "compound" and "varnish" has been increased to some extent. Similarly Class-B insulation materials like asbest mica has been almost a combination of inorganic and binding materials. But nowadays synthesic chemistry is making a remarkable progress. So it comes possible for us to have silicon resin and other good ones of similar charateristics. And even a thin silicon resin insures us to get excellent heat-pro f and insulation, so a better space factor and cost-down in motor design have come possible in most advanced nations of the world, but not in our country. Furthermore, a consideration of productivity and economy in manufacturing process has been neglected by a majority of engineers. This is more unpleasant und more undesirable. I think this rational method of induction motor design using new synthesic resin will devote in making your productivity and economy better. And the nation-wide standard value of electric motor size is sited here. size is sited here.

  • PDF

Efficiency Estimation of Toxicity Free Eire Resistance Cable

  • Yoon, Hun-Ju;Hon, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.3 no.3
    • /
    • pp.34-38
    • /
    • 2002
  • In this paper, efficiency estimation of toxicity fee fire resistance cable experiments was measured smoke density of toxicity free fire resistance polyolefin insulation material and electric field dependence of tree shape in low density polyethylene (LDPE). One of the most serious causes of failure in high-voltage cables, can be an electrical discharge across an internal gab or void in the insulating material. Treeing due to partial discharge is one of the main causes of breakdown in the insulating materials and reduction of the insulation life. Therefore the necessity for establishing a method to diagnose the aging of insulation materials and to predict the breakdown of insulation and research of the fire resistance character has become important. First, we have studied on electric field dependence of tree shape in LDPE about treeing phenomena occurring on the high electrical field. Second, the measurement method is the attenuation quantity of irradiation by smoke accumulating with in a closed chamber due to non-flaming heat decomposition and flaming combustion. A main cause of fire-growth and generating toxic gas when, it bums, should be dealt with great care in life. safety design. The fire gases were occurred carbon monoxide and decomposition than in polyolefin due to incomplete combustion of PVC, which has high content of carbon in chemical compound.

Electrical Properties about Thermal and Water Degradation of Epoxy Powder for Bus Duct (부스닥트용 에폭시 분체도료의 열 및 수중열화에 대한 전기적 특성)

  • Kim, Hyun-Hee;Kim, Sang-Hyun
    • Fire Science and Engineering
    • /
    • v.23 no.3
    • /
    • pp.17-22
    • /
    • 2009
  • Epoxy powder is being in use for insulation materials widely. Especially, in cause of coating insulation can be caused electrical fire and explosion by Joul's heat. This study has been compared and examined around breakdown, arc discharge, and V-t about insulation of Epoxy powder. Also, it has been researched about insulation which is cause of electrical fire and its basic data. According to temperature change, sample KS was stable before the Tg to be about $8{\sim}10%$ decrease in the breakdown test. In case of V-t and arc discharge, it had been kept up suitable characteristic. Also, in case of electrical characteristic, sample KS has excellent capacity.

A Study on the Insulation Properties of Cryogen for the HTS SMES (고온 초전도 에너지 저장장치용 극저온 냉매의 절연 특성 연구)

  • Choi, Jae-Hyeong;Choi, Jin-Wook;Lee, Hai-Gun;Song, Jung-Bin;Kim, Hae-Jong;Seong, Ki-Chul;Kim, Sang-Hyun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.1
    • /
    • pp.16-19
    • /
    • 2009
  • Recently, for improvement of the magnetic field of high temperature superconductor (HTS) apparatus, many studies investigating on operating in the range of $20{\sim}65K$ with liquid helium or the conducting method using cryocooler is actively reviewed. Also, the cooling method using solid nitrogen as cryogen is being suggested. Since the nitrogen has very large specific heat in solid state, it is expected that it can enable long time operation without a continuous supply of cooling energy. However, there is still insufficient data on the characteristics of solid nitrogen such as thermodynamic properties and liquid-solid phase change. Especially, there was almost no study done on the electrical insulation properties of solid nitrogen so far. In this study, solid nitrogen to find the electrical characteristics was made by using cryocooler and cryostat, and investigated the flashover discharge and breakdown. The results of this study will be useful as a basic data for electrical insulation design of the HTS system using solid nitrogen as cryogen.