• 제목/요약/키워드: Heat From Below

검색결과 487건 처리시간 0.036초

Heat Transfer Characteristics of an Internally-Heated Annulus Cooled with R-134a Near the Critical Pressure

  • Hong, Sung-Deok;Chun, Se-Young;Kim, Se-Yun;Baek, Won-Pil
    • Nuclear Engineering and Technology
    • /
    • 제36권5호
    • /
    • pp.403-414
    • /
    • 2004
  • An experimental study of heat transfer characteristics near the critical pressure has been performed with an internally-heated vertical annular channel cooled by R-134a fluid. Two series of tests have been completed: (a) steady-state critical heat flux (CHF) tests, and (b) heat transfer tests for pressure reduction transients through the critical pressure. In the present experimental range, the steady-state CHF decreases with increase of the system pressure for fixed inlet mass flux and subcooling. The CHF falls sharply at about 3.8 MPa and shows a trend towards converging to zero as the pressure approaches the critical point of 4.059 MPa. The CHF phenomenon near the critical pressure does not lead to an abrupt temperature rise of the heated wall, because the CHF occurs at remarkably low power levels. In the pressure reduction transients, as soon as the pressure passes below the critical pressure from the supercritical pressure, the wall temperatures rise rapidly up to very high values due to the departure from nucleate boiling. The wall temperature reaches a maximum at the saturation point of the outlet temperature, and then tends to decrease gradually.

건물의 냉방을 위한 해수열 취득에 관한 실험적 연구 (A new method to convert into seawater heat for the indoor air-conditioning resource)

  • 김기철;이성
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권8호
    • /
    • pp.883-890
    • /
    • 2005
  • The industrial growth and the raised living quality have led to the massive energy consumption. As a result. the polluted environment and the limited amount of energy resources emerged as serious problems to be resolved in 21st century. Especially, in the case of Korea whose imported energy dependency rate is 98.2$\%$ in 2003 and constantly increasing every rear. more than 24$\%$ of overall energy consumption is for housing and commercial use. In order to cope with the shortage of natural energy resources, it is inevitable to develop alternative sustainable energy resources including seawater heat. so that they can replace existing resources. The heat transfer air velocity 3.5 m/s is proper to consideration with the body the pipe size 200A is more suitable than look due to the air velocity quantify and the ratio of pipe surface area. And the error between experimental data with simulation is below 5.34$\%$ so the suggested equation for calculating heat transfer capacity can be used. Therefore out of many methods utilizing seawater heat. this work Presents the efficiency of using sea water heat as a resource for air-conditioners which can be converted from the outside air through the air-to-heat conversion tube . Consequently. this method provides pretty reasonable energy efficiency.

100RT급 하수열원 냉난방시스템 적용 (Application for Heating and Cooling System Using Sewage Water)

  • 장기창;윤형기;박성룡;백영진;나호상;신광호
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.215-220
    • /
    • 2006
  • Along with socioeconomic development and improving standard of living, the heat demand for heating and cooling in residential and commercial sectors is expected to expand rapidly, reaching over 43 million TOE by 2010 in Korea(about 80% increase compared with that in 1995). Since most of this heat demand is loop temperature below $60^{\circ}C$, the utilization of 'unused energy' is surely one of very effective measures to both environmental preservation and energy conservation. 'Unused energy' in this paper is implicated as 'temperature differential energy' available from treated sewage water, useful and abundant heat source for heat pump(cooler in summer and warmer in winter than outside air). An analysis was carried out to estimate the energy potential of treated sewage water for heat pump heat source. Some analysis were taken to study the characteristics of a heat pump system using the treated sewage water as heat source.

  • PDF

열처리로용 소형 축열식 복사관 버너의 축열기 설계 기술평가 (Design and Performance Estimation of Heat Regenerator for Small-scale Regenerative Radiant Tube Burner)

  • 조한창;조길원;이용국
    • 에너지공학
    • /
    • 제13권4호
    • /
    • pp.291-295
    • /
    • 2004
  • 열처리로에 적용되는 소형 축열식 복사관 버너시스템에 사용될 축열기를 설계, 제작하고 그 성능을 실제 축열식 복사관 버너시스템에서 평가하였다. 좁은 튜브간 간격을 갖는 U형 복사관에 축열기를 적용하기 위하여 상하단 단면적이 다른 축열기를 설계, 적용하였다. 구형축열체를 사용하는 2만 ㎉/hr급 축열기를 기존에 개발된 축열기 해석코드를 이용하여 설계, 제작하였으며, 축열기 전후단의 온도 및 압력을 실시간으로 측정하였다. 실험결과를 축열기 해석코드로부터 얻은 배가스의 배출온도와 공기의 예열온도를 비교하여 해석코드의 정확도를 검증하였다. 이론적으로 예상된 성능은 80%의 온도효율과 70%의 배열회수율이 얻어졌으나, 실험적 결과로부터는 온도효율이 80%, 배열회수율이 69%가 얻어졌다. 가장 큰 성능차이는 배가스의 배출온도였는데, 이는 실제 시스템에서 열손실에 의한 축열기로의 배가스 유입온도 하락과 실제 운전에서의 공기/배가스 유량의 증가에 의해 기인된다고 판단된다.

Hall Effect on Couette Flow with Heat Transfer of a Dusty Conducting Fluid Between Parallel Porous Plates Under Exponential Decaying Pressure Gradient

  • Attia Hazem A.
    • Journal of Mechanical Science and Technology
    • /
    • 제20권4호
    • /
    • pp.569-579
    • /
    • 2006
  • In the present study, the unsteady Couette flow with heat transfer of a dusty viscous incompressible electrically conducting fluid under the influence of an exponential decaying pressure gradient is studied without neglecting the Hall effect. The parallel plates are assumed to be porous and subjected to a uniform suction from above and injection from below while the fluid is acted upon by an external uniform magnetic field is applied perpendicular to the plates. The governing equations are solved numerically using finite differences to yield the velocity and temperature distributions for both the fluid and dust particles.

Cryogenic Systems for HTS Power Cables

  • Yeom, Han-Kil;Koh, Deuk-Yong;Lee, Bong-Kyu;Kim, Ig-Seang
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권1호
    • /
    • pp.133-135
    • /
    • 2003
  • Cryogenic systems are requirement for the operation of HTS power cables. In general, HTS power cables require temperature below 77K, a temperature that can be achieved from the liquid nitrogen at latm or sub-cooled LN2 above latm. HTS power cable needs sufficient refrigeration to overcome its low temperature heat loading. This loading typically cones in two forms : (1) heat leaks from the surroundings and (2) internal heat generation. This paper explains the cooling test system of 10m HTS power cable. This system is composed of storage dewar, auto fill system, core cryostat and cold-box. Storage dewar is a LN2 storage tank and auto fill system is a LN2 supply device to the sub-cooler, Core cryostat is a LN2 flow line. Cold box is a control unit of temperature and flow rate. It is composed of control valve, flow meter, sub-cooler and circulation pump, etc..

의복착용 습관이 추위적응 능력에 미치는 영향 (The Effect of Clothing Habits on Cold Acclimatization)

  • 이종민;이순원
    • 한국의류학회지
    • /
    • 제21권3호
    • /
    • pp.536-543
    • /
    • 1997
  • The subjects wearing cool clothing (C group) or warm clothing (W stoup) in daily life from September to February of the following year were tested to examine whether cold acclimatization takes place by clothing habits. Subjects rested at 25$\pm$1$^{\circ}C$, then were exposed to 15$\pm$1$^{\circ}C$, 50$\pm$5% R.H. for 90 min in September, November, December, and February. Rectal temperature (Tre) of C group after 90 min cold exposure did not drop below the Tre in $25^{\circ}C$ throughout the study. W group's Tre, however, dropped below the temperature in 25t from December. Shivering stopped after December in C group while W group continued to show it for the whole study. In resting, C group showed higher heat production than W group in February, and the rate of increase in heat production during cold exposure was smaller in C group than W group in February. C group showed less cold sensation than W group in the same coldness. These results suggest that the level of cold acclimatization may be improved by the habits wearing less clothes in daily life.

  • PDF

개스 Inflow와 Upflow를 갖는 Debris/water/concrete상호작용 해석용 Debris Bed 모델 및 중대사고 조건에 그 적용해석 (A Debris Bed Model with Gab Inflow and Gas Upflow for Debris/Water/Concrete Interaction and Its Application under Severe Accident Condition in LWR.)

  • Jong In Lee;Jin Soo Kim;Byung Hun Lee
    • Nuclear Engineering and Technology
    • /
    • 제17권1호
    • /
    • pp.8-15
    • /
    • 1985
  • Debris bed내·외로부터 깨스유량을 갖는 debris/water 열적상호작용 해석모델이 중대사고 분석을 위해 제시되었다. 제시된 모델은 증기 소비, debris bed에서 수소 생성, 유입깨스 및 화학반응열에 대한 인자들을 포함하고 있으며, 금속-물반응 및 debris/concrete 작용으로 인한 깨스 생성을 평가하기 위해 MARCH code에 도입시켰다. 그 결과 수소원은 격납용기 과도압력에 큰 영향을 미치나 debris bed로 대류깨스 냉각과 콘크리트로 전도 열손실은 debris bed 냉각성에 조그마한 영향을 주는 것으로 나타났다. 하지만 debris 인자의 재가열과 재용융은 콘크리트와 상호작용에 의해 상당히 지연될 수 있다.

  • PDF

LED 조명용 카본 마그네슘 신소재 방열 특성 연구 (A Study of Characteristics of Heat Dissipation Carbon Magnesium New Materials of LED Lighting)

  • 손일수;신성식
    • 한국전기전자재료학회논문지
    • /
    • 제26권12호
    • /
    • pp.915-919
    • /
    • 2013
  • This is the study on the development of fusion heat dissipation of carbon magnesium materials. The purpose of this study is for effective utilization of heat emission which is the core of LED lighting. The result of study enabled the derivation of side satisfying result of making the surface temperature of lighting to be below $70^{\circ}C$ (actual measurement: $58^{\circ}C$) using magnesium. The lighting products that use magnesium was made possible based on the result of this study. Also from the performance aspect such as light distribution, the measurement of light efficiency demonstrated the level of 90 lm/W. Therefore the commercialization of lighting was made possible and the efficiency could be further enhanced by supplementation of LED performance.

A Study on the Effects of System Pressure on Heat and Mass Transfer Rates of an Air Cooler

  • Jung, Hyung-Ho
    • Journal of Mechanical Science and Technology
    • /
    • 제16권5호
    • /
    • pp.696-702
    • /
    • 2002
  • In the present paper, the effects of inlet pressure on the heat and mass transfer rates of an air cooler are numerically predicted by a local analysis method. The pressures of the moist air vary from 2 to 4 bars. The psychrometric properties such as dew point temperature, relative humidity and humidity ratio are employed to treat the condensing water vapor in the moist air when the surface temperatures are dropped below the dew point. The effects of the inlet pressures on the heat transfer rate, the dew point temperature, the rate of condensed water, the outlet temperature of air and cooling water are calculated. The condensation process of water vapor is discussed in detail. The results of present calculations are compared with the test data and shows good agreements.