• 제목/요약/키워드: Heat From Below

검색결과 487건 처리시간 0.033초

도시의 건폐율 및 용적률이 도시기후에 미치는 영향 분석 (Analysis on the Effects of Building Coverage Ratio and Floor Space Index on Urban Climate)

  • 여인애;이정재;윤성환
    • 한국태양에너지학회 논문집
    • /
    • 제29권3호
    • /
    • pp.19-27
    • /
    • 2009
  • In this study, Urban Climate Simulation was performed by 3-Dimensional Urban Canopy Model. The characteristics of urban climate were analyzed combining artificial land coverage, building size, heat production from the air conditioning and topographic conditions as physical variables which affects urban climate characteristics. The results are as follows. (1) The aspects of the urban climatal change is derived to be related to the combination of the building coverage ratio, building height and shading area. According to the building height, the highest temperature was increased by $2.1^{\circ}C$ from 2-story to 5-story building and the absolute humidity by 2.1g/kg maximum and the wind velocity by 1.0m/s was decreased from 2-story to 20-story building. (2) Whole heat generation was influenced by the convective sensible heat at the lower building height and by the artificial heat generation at the higher one over 20-story building influence to some extent of the building coverage ratio. The effect of the altitude is not more considerable than the other variables as below $1^{\circ}C$ of the air temperature. In the last, deriving the combination of building coverage and building height is needed to obtain effectiveness of the urban built environment planning at the point of the urban climate. These simulation results need to be constructed as DB which shows urban quantitative thermal characters by the urban physical structure. These can be quantitative base for suggesting combinations of the building and urban planning features at the point of the desirable urban thermal environment as well as analyzing urban climate phenomenon.

고강도 구조용 철강소재의 대입열 용접 시 열영향부의 조직 미세화 및 기계적 특성 향상에 미치는 TiN 및 B의 효과 (Effects of TiN and B on Grain Refinement of HAZ Microstructure and Improvement of Mechanical Properties of High-strength Structural Steel Under High Heat Input Welding)

  • 박진성;황중기;조재영;한일욱;이만재;김성진
    • 한국재료학회지
    • /
    • 제29권2호
    • /
    • pp.97-105
    • /
    • 2019
  • In the current steel structures of high-rise buildings, high heat input welding techniques are used to improve productivity in the construction industry. Under the high heat input welding, however, the microstructures of the weld metal (WM) and heat-affected zone (HAZ) coarsen, resulting in the deterioration of impact toughness. This study focuses mainly on the effects of fine TiN precipitates dispersed in steel plates and B addition in welding materials on grain refinement of the HAZ microstructure under submerged arc welding (SAW) with a high heat input of 200 kJ/cm. The study reveals that, different from that in conventional steel, the ${\gamma}$ grain coarsening is notably retarded in the coarse grain HAZ (CGHAZ) of a newly developed steel with TiN precipitates below 70 nm in size even under the high heat input welding, and the refinement of HAZ microstructure is confirmed to have improved impact toughness. Furthermore, energy dispersive spectroscopy (EDS) and secondary-ion mass spectrometry (SIMS) analyses demonstrate that B is was identified at the interface of TiN in CGHAZ. It is likely that B atoms in the WM are diffused to CGHAZ and are segregated at the outer part of undissolved TiN, which contributes partly to a further grain refinement, and consequently, improved mechanical properties are achieved.

EFFECT OF HEAT CURING METHODS ON THE TEMPERATURE HISTORY AND STRENGTH DEVELOPMENT OF SLAB CONCRETE FOR NUCLEAR POWER PLANT STRUCTURES IN COLD CLIMATES

  • Lee, Gun-Che;Han, Min-Cheol;Baek, Dae-Hyun;Koh, Kyung-Taek
    • Nuclear Engineering and Technology
    • /
    • 제44권5호
    • /
    • pp.523-534
    • /
    • 2012
  • The objective of this study was to experimentally investigate the effect of heat curing methods on the temperature history and strength development of slab concrete exposed to $-10^{\circ}C$. The goal was to determine proper heat curing methods for the protection of nuclear power plant structures against early-age frost damage under adverse (cold) conditions. Two types of methods were studied: heat insulation alone and in combination with a heating cable. For heat curing with heat insulation alone, either sawdust or a double layer bubble sheet (2-BS) was applied. For curing with a combination of heat insulation and a heating cable, an embedded heating cable was used with either a sawdust cover, a 2-BS cover, or a quadruple layer bubble sheet (4-BS) cover. Seven different slab specimens with dimensions of $1200{\times}600{\times}200$ mm and a design strength of 27 MPa were fabricated and cured at $-10^{\circ}C$ for 7 d. The application of sawdust and 2-BS allowed the concrete temperature to fall below $0^{\circ}C$ within 40 h after exposure to $-10^{\circ}C$, and then, the temperature dropped to $-10^{\circ}C$ and remained there for 7 d owing to insufficient thermal resistance. However, the combination of a heating cable plus sawdust or 2-BS maintained the concrete temperature around $5^{\circ}C$ for 7 d. Moreover, the combination of the heating cable and 4-BS maintained the concrete temperature around $10^{\circ}C$ for 7 d. This was due to the continuous heat supply from the heating cable and the prevention of heat loss by the 4-BS. For maturity development, which is an index of early-age frost damage, the application of heat insulation materials alone did not allow the concrete to meet the minimum maturity required to protect against early-age frost damage after 7 d, owing to poor thermal resistance. However, the combination of the heating cable and the heat insulating materials allowed the concrete to attain the minimum maturity level after just 3 d. In the case of strength development, the heat insulation materials alone were insufficient to achieve the minimum 7-d strength required to prevent early-age frost damage. However, the combination of a heating cable and heat insulating materials met both the minimum 7-d strength and the 28-d design strength owing to the heat supply and thermal resistance. Therefore, it is believed that by combining a heating cable and 4-BS, concrete exposed to $-10^{\circ}C$ can be effectively protected from early-age frost damage and can attain the required 28-d compressive strength.

Characterization of the Intact Form of Thermotoga maritima Pectinase TmPecN Expressed in Escherichia coli

  • Kim, Chung Ho;Cheong, Jong-Joo
    • Journal of Applied Biological Chemistry
    • /
    • 제58권2호
    • /
    • pp.97-100
    • /
    • 2015
  • The thermostable pectinase gene TmPec isolated from Thermotoga maritima was introduced into the NdeI site of pRSET-B vector and expressed in its intact form in Escherichia coli BL21. The overexpressed intact form of pectinase (TmPecN protein) was partially purified by heat-denaturation procedure. TmPecN showed the highest activity between 85 and $95^{\circ}C$, and at approximately pH 6.5. Enzyme activity was stably maintained at temperatures below $85^{\circ}C$. In the presence of $Ca^{2+}$, pectinase activity of TmPecN increased to 128.4% of normal level. In contrast, $Ba^{2+}$, $Zn^{2+}$, and $Mn^{2+}$ strongly inhibited TmPecN activity. We conclude that the biochemical properties of the intact form of TmPecN are comparable to those of the recombinant protein TmPec reported previously.

IGCC 합성가스 냉각기 상부의 열유동 및 입자거동 특성에 대한 전산해석 연구 (Numerical simulations on flow and particle behaviors in the upper part of a syngas cooler for IGCC)

  • 박상빈;예인수;류창국;김봉근
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제45회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.147-148
    • /
    • 2012
  • The syngas produced from coal gasification is cooled down for gas cleaning by a syngas cooler that produces steam. Due to the presence of fly slag in the syngas, erosion, slagging and corrosion especially in the upper part of the syngas cooler may cause major operational problems. This study investigates the flow, heat transfer and particle behaviors in the syngas cooler of a 300MWe IGCC plant by using computational fluid dynamics. For various operational loads and geometry, the gas and particle flows directly impinged on the wall opposite to the syngas inlet, which may lead to erosion of the membrane wall. In the evaporate channels inside the syngas cololr, the particle flows were concentrated more on the outer channel where slagging becomes more serious. The heat transfer to the wall was mainly by convection which was larger on the side wall below the inlet level.

  • PDF

酸化還元樹脂에 關한 硏究 (第一報) Hydroquinone-Formaldehyde Resin 에 關하여 (A Study on Oxidation Reduction Resin (I) On Hydroquinone-Formaldehyde Resin)

  • 성좌경;김용준
    • 대한화학회지
    • /
    • 제4권1호
    • /
    • pp.51-57
    • /
    • 1957
  • Hydroquinone-formaldehyde resin prepared from hydroquinone, formaldehyde and hydrochloric acid as a catalyst was shown to be oxidized with ferric chloride solution and regenerated by stannous chloride solution. The influence of various conditions of preparation on the capacity of oxidation was studied. Results show that the concentration of a solution of hydroquinone has not any effects below 14 parts of water to 1 part of hydroquinone, by the after-heat-treatment for 5-6 hours at 100-120 deg. C. the capacity of oxidation is exhibited a maximum, and decreased as the mole ratio of hydroquinone to formaldehyde increase. The optimum conditions for the preparation of this resin are as follows: hydroquinone 1 part to distilled water 10 parts, mole ratio of formaldehyde 1.2 to hydroquinone 1, and 5 hours of after-heat-treatment at 120 deg. C. The maximum capacity under the above conditions is 13.99 meq/g-ersin.

  • PDF

Heat Cycle Test에서 XLPE 절연체에 인가되는 열이력의 추정 (Estimation of Thermal History in XLPE Insulated Cable during Heat Cycle Test)

  • 김영호;이상진;이건주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 D
    • /
    • pp.1425-1427
    • /
    • 1998
  • The thermal history of XLPE insulated cable during heating cycle voltage test specified by IEC 840 was examined by DSC(differential scanning calorimetry) method, of which the principal is on the basis of the phenomenon that the crystals in polyethylene are rearranged as it is annealed near/below the melting temperature. From the result, it can be estimated that XLPE insulation near the conductor was exposed at the temperature of about $100^{\circ}C$ with the electrical stress through the test.

  • PDF

개방된 캐비티를 가진 채널 내에서의 혼합대류 유동과 열전달 특성 (Characteristics of the Mixed Convection Flow and Heat Transfer in a Channel with Open Cavity)

  • 고영창;배대석;김남식
    • 동력기계공학회지
    • /
    • 제11권4호
    • /
    • pp.56-64
    • /
    • 2007
  • A numerical simulation is carried out mixed convection in horizontal channel with a heat source from below of rectangular cavity. Finite volume method was employed for the discretization and PISO algorithm was used for calculating pressure term. The parameters governing the problem are the Reynolds number ($10^{-2}{\leq}Re{\leq}50$), the Rayleigh number ($10^3{\leq}Ra{\leq}2.06{\times}10^5$), the Prandtl number ($0.72{\leq}Pr{\leq}909$), the aspect ratio ($0.5{\leq}AR=W/H{\leq}2$) and the angle of inclination ($0^{\circ}{\theta}60^{\circ}$). Mean Nusselt number distributions were obtained and effect of Reynolds number, Rayleigh number and Prandtl number on mixed convection in the horizontal channel with rectangular cavity were investigated.

  • PDF

A comparing on the use of Centrifugal Turbine and Tesla Turbine in an application of Organic Rankine Cycle

  • Thawichsri, Kosart;nilnont, Wanich
    • International Journal of Advanced Culture Technology
    • /
    • 제3권2호
    • /
    • pp.58-66
    • /
    • 2015
  • This paper aims to compare the use of Centrifugal Turbine and Tesla Turbine in an application of Organic Rankine Cycle (ORC) Machine using Isopentane as working fluid expanding. The working fluid has boiling point below boiling water and works in low-temperature sources between $80-120^{\circ}C$ which can be produced from waste heat, solar-thermal energy and geothermal energy etc. The experiment on ORC machine reveals that the suitability of high pressure pump for working fluid has result on the efficiency of work. In addition, Thermodynamics theory on P-h diagram also presented the effect of heat sources' temperature and flow rate on any work. Thus, the study and design on ORC machine has to concern mainly on pressure pump, flow rate and optimized temperature. Result experiment and calculate ORC Machine using centrifugal Turbine efficiency better than Tesla turbine 30% but Tesla Turbine is cheaper and easily structure. Further study on the machine can be developed throughout the county due to its low cost and efficiency.

CVD법으로 합성된 알루미나 박막 및 분말의 열처리에 따른 특성 (Properties of the Chemically Vapor Deposited Alumina Thin Film and Powder on Heat Treatment)

  • 최두진;정형진
    • 한국세라믹학회지
    • /
    • 제26권2호
    • /
    • pp.235-241
    • /
    • 1989
  • A study on the APCVD(atmospheric pressure chemical vapor deposition) Al2O3 was done by using the aluminum-tri-isopropoxide/N2 reaction system at 40$0^{\circ}C$. When the flow rate of the carrier gas(N2) was over 2SLPM, heterogeneous reaction was observed. However, when the flow rate of the carrier gas was below 2SLPM, a porously deposited film or powder formation was observed. The film formed by a heterogeneous reaction was optically dense. The dense film is thought to be a kind of a hydrated alumina. After a thermal treatment of the film in the range of temperature from $600^{\circ}C$ to 1, 20$0^{\circ}C$, properties of the film seems to be changed due to dehydration and densification process. In the case of the powder on heat treatment(600~1, 20$0^{\circ}C$), both a phase transformation and the change of OH peak was observed.

  • PDF