• Title/Summary/Keyword: Heat Flow Meter 436

Search Result 4, Processing Time 0.013 seconds

Building Materials Thermal Conductivity Measurement and Correlation with Heat Flow Meter, Laser Flash Analysis and C-Therm TCi (HFM, LFA와 TCi를 이용한 건축 재료의 열전도율 측정과 상관관계 분석)

  • Cha, Jung-Hoon;Seo, Jung-Ki;Su-Min, Kim
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.92-97
    • /
    • 2011
  • Nowdays the most critical problem is global warming and the most important reason is the high emition of carbondioxide. 23% of the use of carbondioxide is used in building and decreasing the use of it is very important. One of the biggest factor that can decrease the use of energy is developing the heat conducting ratio of the materials we use in building. Heat conducting ratio is the important factor in the use of reducing energy comsumation. In this research, there are methods about how to measure the heat conducting ratio, and the existing the representing measuring method which is Heat Flow Meter HFM 436, Laser Flash Analysis and find out about the TCi of the new method C-Therm and compare the results.

  • PDF

Correlation Analysis of the Thermal Conductivity Heat Flow Meter and MTPS (Modified Transient Plane Source) Method Using Wood Flooring and Wall Materials (목질마루바닥재와 벽체용 재료를 이용한 평판열류계법과 MTPS (Modified Transient Plane Source)법의 열전도율 상관관계 분석)

  • Cha, Jung-Hoon;Seo, Jung-Ki;Kim, Su-Min
    • Journal of the Korea Furniture Society
    • /
    • v.22 no.2
    • /
    • pp.118-125
    • /
    • 2011
  • These days global warming is the most important problem and the most important factor is high emission of carbon dioxide. The 23% of carbon dioxide emission for building construction must be reduced. Thermal conductivity is the most basic factor that can decrease the energy consumption especially insulation. Therefore, an accurate and continuous thermal conductivity measurement can be a way to save energy. In this paper, there are methods about how to investigate thermal conductivity measurements and comparing two methods which are the Heat Flow Meter 436 and TCi.

  • PDF

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

Development of High-insulation Packaging using Recycled PET and Comparison of Insulation Performance with Existing Styrofoam and Paper Boxes (재생페트를 이용한 고단열 패키징 개발과 기존의 스티로폼 및 종이 박스와의 단열성능 비교)

  • Ryu, Jae Ryong;Yook, Se Won;Kal, Seung Hoon;Shin, YangJae
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.25 no.3
    • /
    • pp.111-116
    • /
    • 2019
  • Thermal insulation performance of new insulation packaging made of recycled PET nonwoven (thickness : 10 mm) was verified by conducting comparative experiment with an EPS box (thickness : 25 mm) and a double wall corrugated box (thickness : 7 mm). Three ice packs (300 g) were positioned 200 mm above the bottom inside each box, all of which are placed side by side and temperature change of 2 points (5mm under middle icepack and 130 mm under middle icepack) was recorded by data logger (GL-840, Graphtec) for 16 hours under the environment of 29℃. The new packaging box showed 75% higher insulation performance than the EPS box and 180% higher than the corrugated box. In order to figure out the reason for insulation performance difference among boxes, thermal conductivities of each box material were measured using heat flow meter (HFM436 lamda, Netzsch). U-value (thermal conductivity divided by thickness) of EPS was lower than recycled pet nonwoven by 57%, which seemed to be opposite to the result of insulation test of boxes. This was explained by high water vapor transmission rate of EPS (6 times higher than PET insulation) and air pocket effect of PET insulation.