• 제목/요약/키워드: Heat Exchangers

검색결과 854건 처리시간 0.024초

A Review on the Performance of Fin-and-Tube Heat Exchangers Under Frosting and Defrosting Conditions

  • Kim, Yong-Chan;Lee, Ho-Seong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제13권3호
    • /
    • pp.152-157
    • /
    • 2005
  • This paper reviews the literature on the performance of fin-and-tube heat exchangers under frosting and defrosting conditions. The effects of frosting and defrosting on the following parameters were discussed: frost growth, overall heat transfer coefficient, surface roughness, and surface characteristics on the heat exchanger. Comparisons of the experimental results and empirical correlations that were obtained from open literature were presented. In addition, a review of the defrosting methods was conducted.

유동공진이 판형 열교환기의 열전달 향상과 압력강하에 미치는 영향 (Effects of Flow Resonance on Heat Transfer Enhancement and Pressure Drop in a Plate Heat Exchanger)

  • 한상규;강병하
    • 설비공학논문집
    • /
    • 제17권2호
    • /
    • pp.165-172
    • /
    • 2005
  • Heat transfer enhancement of three types of brazed plate heat exchangers has been evaluated experimentally. The effects of flow resonance in a plate heat exchanger on the heat transfer rate and pressure drop have been investigated in a wide range of mass flow rates in detail. The problem is of particular interest in the innovative design of a plate heat exchanger by flow resonance. The results obtained indicate that both heat transfer coefficient and pressure drop are increased as mass flow rate is increased, as expected. It is also found that the heat transfer enhancement is increased with an increase in the plate pitch, while the heat transfer is decreased with a decrease in the chevron angle. Pressure drop also increased with an increase in the plate pitch and with a decrease in the chevron angle. Heat transfer enhancement in the plate heat exchangers is maximized by flow resonance and the resonance frequency of the present plate heat exchangers is found to be in the range of $10~15\;Hz$.

PF 열교환기의 열전달과 압력강하 특성 실험 연구 (Experimental of Study on Heat Transfer and Pressure drop of PF Heat Exchangers)

  • 엄유식;서동남;박경만;이상재;김대훈;권영철
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.519-524
    • /
    • 2008
  • In the present study, the air-side heat transfer and pressure drop characteristics of the fin-tube and PF heat exchangers have been experimentally investigated under the cooling standard condition. Fin type of PF heat exchanger is a triangler and squarer form. The experimental data of the slit fin-tube and two kinds of PF heat exchangers are measured using the air-enthalpy calorimeter and the constant temperature water bath. As the inlet air velocity increases, the heat transfer rate and pressure drop of the heat exchanger increased. The heat transfer rate and pressure drop of PF-2 heat exchanger of the squarer fin is larger than that of PF-1 heat exchanger of the triangler fin. As the inlet air temperature increases, the heat transfer rate decreases and the pressure drop is nearly uniform.

  • PDF

핀-관 열교환기의 열별 열전달 특성 (Heat Transfer Characteristics of Individual Rows for Fin-and-Tube Heat Exchangers)

  • 김내현;신태룡;한성필
    • 설비공학논문집
    • /
    • 제19권2호
    • /
    • pp.149-155
    • /
    • 2007
  • The row-by-row heat transfer characteristics of fin-and-tube heat exchangers were experimentally investigated. Three wavy fin samples having different rows (one, two and three) and one plain fin sample (three row) were tested for $600{\leq}Re_{D}{\leq}4,000$. The heat transfer data were obtained for individual rows, and the corresponding heat transfer coefficients were reduced from the data. Results showed that the heat transfer coefficients were strongly dependent on the tube row. The heat transfer coefficient decreased as the tube row increased. However, the row effect was different depending on the fin shape. For the wavy fin, the row effect significantly decreased as the Reynolds number increased, yielding approximately the same heat transfer coefficients at $Re_{D}{\approx}2,500$. For the plain fin, however, the row effect lasted for the whole Reynolds number range. The increased mixing of bulk flow by wavy channels appears to induce high heat transfer coefficient (accordingly diminishing row effect) at downstream rows. The heat transfer coefficients of individual rows were higher for heat exchangers having larger tube rows.

구리 재질의 평판 핀과 나선형 핀이 사용된 핀-관 열교환기의 공기측 성능 (Air-Side Performance of Fin-and-Tube Heat Exchanger with Copper Plate or Copper Spiral Fins)

  • 이진욱;박지훈;이정표;김내현
    • 대한기계학회논문집B
    • /
    • 제35권3호
    • /
    • pp.269-278
    • /
    • 2011
  • 본 연구에서는 구리 재질의 평판 핀과 나선형 핀-관 열교환기에 대하여 핀 피치와 열수의 변화에 따른 공기측 전열성능을 검토하였다. 두 형상 모두 핀 피치가 열전달계수에 미치는 영향은 미미하였다. 마찰인자는 핀 피치가 증가하면 증가하였다. 열수가 미치는 영향은 형상에 따라 다르게 나타났다. 평판 핀-관 열교환기의 경우 열전달계수는 열수가 증가할수록 감소하였다. 하지만 나선형 핀-관 열교환기의 열전달 계수는 열수가 증가하면서 그 값이 증가하는 경향을 보였다. 평판 핀-관 열교환기의 열전달계수는 나선형 핀-관 열교환기의 열전달계수보다 높게 나타났다. 하지만 열수가 증가하면 그 차이가 줄어들어 4열이 되면 거의 같았다. 한편 마찰인자는 평판 핀-관 열교환기에서 다소 높게 나타나고 열수의 영향은 크지 않았다. 본 실험 데이터를 기존 상관식의 예측치와 비교하였다.

수평형 지중열교환기의 열전달 성능에 관한 연구 (A Study on Heat Transfer Performance of Horizontal Ground Heat Exchanger)

  • 정민호;박성룡;나호상;백영진;윤형기;장기창
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.684-687
    • /
    • 2005
  • Ground source heat pump systems are used for heating, ventilating and air-conditioning systems in commercial buildings, schools, and factories because of low operating and maintenance costs. These systems use the earth as a heat source in heating mode and a heat sink in cooling mode. Ground heat exchangers are classified by a horizontal type and vertical type according to the installation method. A horizontal type means that a heat exchanger is laid in the trench bored in 1.2 to 1.8 m depth. The solar heat and the rainwater are affected by the performance of heat exchanger and causes mutual influence among heat exchangers. In this study, to evaluate the performance of straight type, slinky type, and spiral type of horizontal ground heat exchangers designed on 1 RT scale, test sections are buried on the earth and experimental apparatus is installed. Therefore the performance of these is estimated.

  • PDF

대전력 반도체 정류기 수냉식 냉각 설비 냉매 온도 제어시스템에 관한 연구 (The Study of Thyristor Valve Water Cooling Control Systems)

  • 임익헌;류호선
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.230-233
    • /
    • 1999
  • The design and implementation of thyristor water cooling control systems in considered in this pape Coolant water is pumped through the thyristor heat sinks where heat is transferred from the thyristo to the water. This water is then pumped through outdoor air-to-water heat exchangers where heat I transferred to the outside air. Since the water must be pure, it is filtered and de-ionized. Also the water temperature must be below dew-point temperature. Redundant pumps, outdoor heat exchangers, power supply system, controller monitoring system are provided for system reliability and availability.

  • PDF

착상을 수반한 핀-관 열교환기의 성능평가계수에 관한 연구 (The Study of Performance Evaluation Coefficient of Fin-and-Tube Heat Exchangers with Frosting)

  • 최봉준;황준현;신종민
    • 설비공학논문집
    • /
    • 제15권2호
    • /
    • pp.132-136
    • /
    • 2003
  • For the study of performance evaluation on different shape heat exchangers that have the same energy consumption in a refrigerator, we make performance evaluation coefficient (PEC) which can distinguish performance of different shape heat exchangers. The results were reported in order to compare with for the dry frosting and wet frosting test as various definition of PECs. Results showed that PEC of dry frosting test is higher than that of wet frosting test because attached water droplet increases pressure drop of air-side then this decreases performance of heat exchanger.

다양한 형태의 단속표면을 갖는 공조기용 핀-관 열교환기의 열전달 특성 (Heat transfer characteristics of fin and tube heat exchangers with various interrupted surface for air conditioning application)

  • 윤점열;이관수
    • 대한기계학회논문집B
    • /
    • 제20권12호
    • /
    • pp.3938-3948
    • /
    • 1996
  • This study is related with the experimental investigation on the heat transfer and pressure drop characteristics of the fin-and-tube heat exchangers with three different interrupted fins and a plane fin for air-conditioning application. Experiments were conducted accordingly following the appropriate development process. Geometry similitude experiment was introduced to predict the performance of fins, and prototype experiment was also performed to confirm the validity of geometry similitude experimental results. However, these experimental results were limited to the sensible heat transfer characteristics of the heat exchangers. Hence, additional experiment was performed using refrigerant to investigate the latent heat transfer characteristics. This paper presents an appropriate process for the development of a new type heat exchanger. Sensible and latent heat transfer characteristics for each fin configuration is also provided along with the optimal fin configuration.

플라스틱 판형 열교환기의 유동 및 열전달 특성에 관한 수치해석적 연구 (A Numerical Study on the Flow and Heat Transfer Characteristics of Plastic Plate Heat Exchanger)

  • 정민호;유성연;한규현;윤홍익
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1366-1371
    • /
    • 2008
  • Four simulation models of plastic plate heat exchangers are designed and simulated. The flat plate type heat exchanger is designed as the reference model in order to evaluate how much thermal performance increases. The turbulence promoter type heat exchanger is fabricated with cylindrical-type vortex generators and rib-type turbulence promoters. The corrugate type is obtained from the conventional stainless steel compact heat exchangers, which are called the herringbone-type compact heat exchangers. The dimple type heat exchanger has a number of dimples on its surface. In this study, the flow and heat transfer characteristics of the plastic plate heat exchanger are investigated using numerical simulation and compared with experimental results. The flows are assumed as a three-dimensional, incompressible and turbulent model. The standard k-$\varepsilon$ model is used as the turbulent flow modeling, the SIMPLE algorithm is used to treat the coupling between pressure and velocity, and first order upwind scheme is used for discretization of momentum, turbulent and energy. The computational analysis and experimental results both show that the friction coefficient and Nu number is highest in the corrugate type.

  • PDF