• Title/Summary/Keyword: Heat Environment

Search Result 2,478, Processing Time 0.023 seconds

A Study on the Physical Properties of Mineral Hydrate Insulation Material Mixed with Basalt Fiber

  • Park, Jae-Wan;Chu, Yong-Sik;Seo, Sung-Kwan;Jeong, Jae-Hyen
    • Journal of the Korean Ceramic Society
    • /
    • v.53 no.1
    • /
    • pp.63-67
    • /
    • 2016
  • Mineral hydrate is a new insulation material that compensates for the defects of existing materials. Mineral hydrate is made of inorganic ingredients; therefore, it is nonflammable. The porous structure of mineral hydrate makes the material lightweight and insulating. Mineral hydrate insulation and similar products have been studied and manufactured in Korea and abroad. However, these insulation materials need to improve in terms of strength. In this study, basalt fiber was used to enhance the strength. In order to observe the property changes, compressive strength, heat conductivity, and specific gravity were measured and XRD pattern analysis was performed. These tests confirmed that basalt fiber was effective at improving the strength and lowering the heat conductivity of mineral hydrate insulation.

Design of Induction Heating Coil for Automatic Hull Forming System

  • Ryu, Hyun-su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.3
    • /
    • pp.360-366
    • /
    • 2018
  • In shipyards hull forming is performed by the line heating method using a gas torch and by cold treatment using a roll-press. However, this forming process has some issues, such as difficulties in controlling and accurately estimating the amount of the heat input, as well as a harsh working environment due to exposure to loud noises and air pollution. The induction heating method, which is introduced in this paper, exhibits good control and allows for the estimation of precise heat input. Also, workers can carry out the induction heating in a comfortable working environment. In this research, the induction heating simulation, which consists of electro-magnetic, heat transfer and thermal elasto-plastic analysis, was developed and modified through induction heating experiments. Finally, the effective heating coil was designed for the automatic hull forming system based on the results of induction heating simulation. For the purposes of a future study, if an algorithm to obtain optimal working conditions is developed, automatic systems for hull forming can then be constructed.

Study on the Underground Thermal Environment around Wells for a Design Method of Open-Loop Geothermal System (개방형 지열 시스템 설계법 개발을 위한 관정 주위 지중 온도 환경 검토)

  • Bae, Sangmu;Kim, Hongkyo;Kim, Hyeon-Woo;Nam, Yujin
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.13 no.1
    • /
    • pp.14-20
    • /
    • 2017
  • Groundwater heat pump (GWHP) system can achieve higher performance of the system by utilizing heat source of the annual constant groundwater temperature. The performance of GWHP system depends on the ground thermal environment such as groundwater temperature, groundwater flow rate and hydraulic conductivity. In this study, the geothermal environment was analyzed by using numerical simulation for develop the two-well geothermal system. As the result, this paper shows the change of the groundwater level and underground temperature around wells according to the conditions of flow rate and hydraulic conductivity.

Construction and Case Analysis of Detailed Urban Characteristic Information on Seoul Metropolitan Area for High-Resolution Numerical Weather Prediction Model (고해상도 수치예보모델을 위한 수도권지역의 상세한 도시특성정보 구축 및 사례 분석)

  • Lee, Hankyung;Jee, Joon-Bum;Yi, Chaeyeon;Min, Jae-Sik
    • Atmosphere
    • /
    • v.29 no.5
    • /
    • pp.567-583
    • /
    • 2019
  • In this study, the high-resolution numerical simulations considering detailed anthropogenic heat, albedo, emission and roughness length are analyzed by using single layer Urban Canopy Model (UCM) in Weather Research Forecast (WRF). For this, improved urban parameter data for Seoul Metropolitan Area (SMA) was collected from global data. And then the parameters were applied to WRF-UCM model after it was processed into 2-dimensional topographical data. The 6 experiments were simulated by using the model with each parameter and verified against observation from Automated Weather Station (AWS) and flux tower for the temperature and sensible heat flux. The data for sensible heat flux of flux towers on Jungnang and Bucheon, the temperature of AWS on Jungnang, Gangnam, Bucheon and Neonggok were used as verification data. In the case of summer, the improvement of simulation by using detailed anthropogenic heat was higher than the other experiments in sensible flux simulation. The results of winter case show improved in all simulations using each advanced parameters in temperature and sensible heat flux simulation. Improvement of urban parameters in this study are possible to reflect the heat characteristics of urban area. Especially, detailed application of anthropogenic heat contributed to the enhancement of predicted value for sensible heat flux and temperature.

Granger Causality between Thermal Environment and PM10 of Seoul's 25 Districts (서울특별시 25개 자치구의 열환경과 미세먼지 간 Granger 인과관계)

  • Youn, Jee Min;Kim, Hyungkyoo
    • Journal of Environmental Science International
    • /
    • v.31 no.1
    • /
    • pp.9-21
    • /
    • 2022
  • Today's cities require deeper understanding of the thermal environment and PM10 as their management becomes more critical. Based on these circumstances, this study investigated the Granger causality between the thermal environment and PM10 of the 25 districts of Seoul, the most populous and urbanized city in Korea. The results of the Granger causality test on the thermal environment and PM10 were classified into 12 types. Except for type 12, the temperature and urban island heat intensity of the other 11 types operated as a Granger-cause to each other in both directions. Temperature operates as a Granger-cause of urban island heat intensity in type 12. The PM10 level and urban pollution island intensity operated as a Granger-cause to each other in all districts. For types 1 and 2, thermal environment operated as a Granger-cause to PM10 in one direction, and type 3-type 12 confirmed that thermal environment and PM10 operated as a Granger-cause in both directions. Findings reveal the intricate causalities between thermal environment and PM10 at the district level and suggest mitigation strategies that are more location based.

Exploring Physical Environments, Demographic and Socioeconomic Characteristics of Urban Heat Island Effect Areas in Seoul, Korea (서울시 도시열섬현상 지역의 물리적 환경과 인구 및 사회경제적 특성 탐색)

  • Cho, Hyemin;Ha, Jaehyun;Lee, Sugie
    • Journal of the Korean Regional Science Association
    • /
    • v.35 no.4
    • /
    • pp.61-73
    • /
    • 2019
  • Urban development and densification have led to the Urban Heat Island Effect, in which the temperature of urban space is higher than the surrounding areas, and the intensity is increasing with climate change. In addition, when the city's air temperature rises in summer, low-income, elderly population, and socially vulnerable people who have health problems lack the ability to cope with the elevated heat environment. Therefore, this study aimed to identify the urban heat island area of Seoul through Hotspot analysis, which is a spatial statistics technique, and explored physical environments, demographic and socioeconomic characteristics of urban heat island effect areas using logistic regression models. This study performed urban heat island hotspot analysis using the average air temperatures of the 423 administrative dongs in Seoul. Analysis results identified that the urban heat islands were concentrated in Jung-gu, Jongno-gu, Yongsan-gu, and Yeongdeungpo-gu. Logistic regression analysis results indicated that urban heat island areas of Seoul were affected by residential floor area ratio, commercial facility floor area ratio, overall floor area ratio, impervious surface ratio, and normalized difference vegetation index(NDVI). In addition, as a result of analyzing the vulnerable area of thermal environment considering the demographic and socioeconomic characteristics of the heat island area, urban heat island areas of Seoul were significantly associated with the proportion of low-income elderly living alone. The result of this study provided useful insights for urban thermal environmental design and policy development that could improve the thermal environment for the socially disadvantaged urban population.

Research on using the exhausted heat from subway tunnel as unused energy (미활용 에너지원으로서의 지하철 배열이용에 관한 연구)

  • 김종렬;금종수;최광환;윤정인;박준택;김동규;김보철;정용현
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.6
    • /
    • pp.695-701
    • /
    • 1998
  • Researches on unused energy are being continued because of the limited fossil fuel and the destruction of environment. Therefore this study was peformed as follows. The collectable amount of exhausted heat for an air-conditioning was calculated by the subway thermal environment prediction program. And the electric power needed by conventional heat source equipments was compared with one by unused heat source equipments when the exhausted heat was used by heat pump in heating and hot water supplying. The results are summarized as follows; 1) Forced ventilation should be conducted to keep optimal temperature in subway tunnel in summer as well as in winter. According to the simulation, temperature in tunnel was higher than that on the ground in summer when the forced ventilation was conducted only in winter. 2) Ventilating time should be calculated out to the optimal condition for not only saving power of ventilation fan but reusing exhausted heat. By the simulation, it is certain that the exhausted heat should be eliminated in air-conditioning time. 3) The use of exhausted heat source heat pump could save 8% of electric power per hour in comparison with existing heat pump. It was based on a present heat generation and traffic for ventilating time of general air-conditioning, but could be different by ventilating time. 4) As the traffic increases up to 1.5 or 2 times, electric power consumption of the conventional heat pump increases to 11% or 13.5% per mean hour in comparison with that of the exhausted heat source heat pump, though all-day ventilation.

  • PDF

Effects of Korean Ginseng(Panax Ginseng, C. A. Meyer) Extracts on Rat Exposed to Heat Environment (고려인삼 추출물이 고온환경에 노출된 흰쥐에 미치는 영향)

  • Hong, Hee-Do;Kim, Young-Chan;Choi, Sang-Yoon;Rho, Jeong-Hae;Lee, Young-Chul;Seo, Joo-Yeon
    • Journal of Ginseng Research
    • /
    • v.30 no.4
    • /
    • pp.199-205
    • /
    • 2006
  • It was investigated that how the periodic exposure to heat environment, and the treatment of korean white and red ginseng extracts had effects on the weight, diet uptake, blood components, organ weight, and the lipid peroxidation of liver in male S.D. rats. In the result of experiments using rats, chronic heat environment for 7 days at $38^{\circ}C$, 5 hrs per day, induced significant decrease of an average increase rate of body weight, but diet uptake was not affected clearly. In heat environment, the number of red blood cells and hemoglobin were not changed, but the number of white blood cells was significantly increased. The liver weight against body weight was decreased in rats. Also, MDA contents, related to lipid peroxidation, were remarkably increased in rat liver by heat environment. These physiological changes were attenuated by treatments of white and red ginseng extracts before and after exposure to heat environment, particularly in growth rate and lipid peroxidation of liver in rats. Also, red ginseng extracts had a better effect, though it was not that significant, than the white ginseng on the inhibition of lipid peroxidation and the weight change of liver. Although the investigation on the effective components and the study on the activity changes of associated materials are needed to perform, these present results imply that Korean ginseng may contribute to protection of body homeostasis against drastic climate changes.

EFFECTS OF HEAT EXPOSURE ON WATER METABOLISM AND PASSAGE IN SHEEP

  • Katoh, K.;Buranakarl, C.;Matsunaga, N.;Lee, S.R.;Sugawara, T.;Sasaki, Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.2 no.2
    • /
    • pp.91-97
    • /
    • 1989
  • The present experiment was carried out to investigate the effects of heat exposure on water metabolism and the passage of indigestible particles in sheep. Water intake, respiratory rate, rectal temperature and pH of ruminal fluid and urine were significantly higher (P<0.05) in the hot environment ($32\;^{\circ}C$) than in the control environment ($20\;^{\circ}C$). Urine osmolality and blood volume were increased, while glomerular filtration rate was decreased, in the hot environment. The liquid flow rate from reticulo-rumen and the excretion of indigestible particles of specific gravity 0.99 (but not 1.27 or 1.38) were increased in the hot environment. From these findings, it is suggested that an increased water intake evoked by heat exposure might affect the flow rate of digesta in sheep.