• 제목/요약/키워드: Heat Diffusion

검색결과 916건 처리시간 0.025초

Czochralski 법으로 성장시킨 실리콘 단결정 Wafer에서의 Gettering에 관한 연구 (A Study on the Gettering in Czochralski-grown Single Crystal Silicon Wafer)

  • 양두영;김창은;한수갑;이희국
    • 한국세라믹학회지
    • /
    • 제29권4호
    • /
    • pp.273-282
    • /
    • 1992
  • The effects of intrinsic and extrinsic gettering on the formation of microdefects in the wafer and on the electrical performance at near-surfaces of three different oxygen-bearing Czochralski silicon single crystal wafers were investigated by varying the combinations of the pre-heat treatments and the phosphorus diffusion through the back-surface of the wafers. The wafers which had less than 10.9 ppma of oxygen formed no gettering zones irrespective of any pre-heat treatments, while the wafers which had more than 14.1 ppma of oxygen and were treated by Low+High pre-heat treatments generated the gettering zone comprising oxygen precipitates, staking faults, and dislocation loops. The effects of extrinsic gettering by phosphorus diffusion were evident in all samples such that the minority carrier lifetimes were increased and junction leakage currents were decreased. However, the total gettering effects among the different pre-heat treatments did not necessarily correspond to the gettering structure revealed by synchrotron radiation section topograph.

  • PDF

지하계단 화재에서 유동에 대한 실험연구 (An Experimental Study of Flow Behaviour in Underground Stairway Fire)

  • 정진용;홍기배;이재하;유홍선
    • 설비공학논문집
    • /
    • 제15권10호
    • /
    • pp.821-827
    • /
    • 2003
  • Reduced-scale experimental study was carried out on the heat flow behavior which flows under the sloped ceiling in underground fire. Temperature and flow velocity were measured to characterize the ceiling jet along the sloped stairway ceiling. The methanol fuel was used as a model fire source giving 2.2 and 3.4 kW, with changing the slope angle of stairway adopting of 15, 25, 35, and 45 deg. Based on the experimental data, excess temperature and velocity along the sloped stairway ceiling were examined which are usefully applicable to estimate the activating conditions of heat detector and sprinkler head mounted on the sloped ceiling. Excess temperature in upper exit of the sloped stairway was also examined to analyze the soffit which delays the smoke diffusion. The result shows that the activating conditions of heat detector and sprinkler in the sloped stairway ceiling have to be considered differently in a point of about 30 deg.

작은 크기의 무딘 물체에 대한 극초음속 유동의 수치해석 (Numerical Analysis of Hypersonic Flow over Small Radius Blunt Bodies)

  • 이창호;박승오
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2002년도 춘계 학술대회논문집
    • /
    • pp.109-114
    • /
    • 2002
  • The effect of nose radius on aerodynamic heating are investigated by using the Wavier-Stokes code extended to thermochemical nonequilibrium airflow. A spherical blunt body, whose radius varies from 0.003048 m to 0.6096 m, flying at Mach 25 at an altitude of 53.34 km is considered. Comparison of heat flux at stagnation point with the solution of Viscous Shock Layer and Fay-Riddell are made. Obtained result reveals that the flow chemistry for very small radius is nearly frozen, and therefore the contribution of heat flux due to chemical diffusion is smaller than that of translational energy. As the radius becomes larger, the portion of diffusion heat flux becomes greater than translational heat flux and approaches to a constant value.

  • PDF

Pt-Aluminide로 코팅된 초내열합금의 열처리에 따른 미세조직변화 (Effect of Heat Treatment on the Microstructural Evolution of Pt-aluminide Coated Ni-based Superalloy)

  • 주동원;박상현;정연길;이구현;김창석
    • 열처리공학회지
    • /
    • 제19권2호
    • /
    • pp.103-108
    • /
    • 2006
  • Microstructural evolution of Pt-aluminide coated Ni-based superalloy has been investigated with ductilization heat treatment. The Pt coat was prepared on the superalloy and then aluminide coating was conducted using a pack cementation process. Samples were heat-treated at $1050^{\circ}C$ for 2 hrs and the microstructure and element analysis were preformed. A various precipitated compounds were observed within the coating layer and the diffusion region in the Pt-aluminide coating and heat treatment, indicating that the bi-phase compounds of $PtAl_2$ and NiAl were performed during the Pt-aluminide coating, whereas $M_{23}C_6$, MC, $Ni_3Al$ and ${\sigma}$ phases were precipitated in the inter-diffusion region. The bi-phase compounds of $PtAl_2$ and NiAl were transformed into the single phase compound of $PtAl_2$ with the heat treatment, increasing the amount of carbide and ${\sigma}$ phase.

음향 가진된 충돌 역 확산화염의 화염형상과 열전달 특성에 관한 실험적 연구 (An Experimental Study on the Flame Appearance and Heat Transfer Characteristics of Acoustically Excited Impinging Inverse Diffusion Flames)

  • 강기중;이기만
    • 한국산학기술학회논문지
    • /
    • 제11권10호
    • /
    • pp.3647-3653
    • /
    • 2010
  • 본 오디오 스피커로 음향 가진과 비가진 된 충돌 역 확산화염에서 화염의 형상과 열전달 특성에 관한 실험적 연구를 수행하였다. 가진에 의해 화염은 반응대가 넓어지고 화염 길이는 좀 더 짧아지는 경향을 보이며 충돌판의 정체점에서 열전달 성능인 열유속은 가진에 의해 향상되는 것으로 나타났다. 이러한 가진 효과는 당량비가 높은 과농한 상태 보다 상대적으로 낮은 혼합 상태에서 효과적으로 영향을 미치는 것으로 파악되는데 이는 가진에 의해 주위산화제가 연료 분류로의 유입이 향상되어 나타나는 것으로 판단된다. 이러한 현상으로 본 연구에서는 당량비가 0.8인 경우 정체점에서 총 열유속이 최대 57% 증가되는 것으로 나타났다. 따라서 본 연구를 통해 가진 연소가 충돌 분류 화염에서 열전달 성능을 향상시키는데 효과적인 방법임을 확인하게 되었다.

MBF 20으로 브레이징한 STS304 콤팩트 열교환기 접합부의 미세조직에 미치는 가열속도의 영향 (Effect of Heating Rates on Microstructures in Brazing Joints of STS304 Compact Heat Exchanger using MBF 20)

  • 김준태;허회준;김현준;강정윤
    • Journal of Welding and Joining
    • /
    • 제34권2호
    • /
    • pp.46-53
    • /
    • 2016
  • Effect of heating rate on microstructure of brazed joints with STS 304 Printed Circuit Heat Exchanger (PCHE),which was manufactured as large-scale($1170(L){\times}520(W)){\times}100(T)$, mm), have been studied to compare bonding phenomenon. The specimens using MBF 20 was bonded at $1080^{\circ}C$ for 1hr with $0.38^{\circ}C/min$ and $20^{\circ}C/min$ heating rate, respectively. In case of a heating rate of $20^{\circ}C/min$, overflow of filler metal was observed at the edge of a brazed joints showing the height of filler metal was decreased from $100{\mu}m$ to $68{\mu}m$. At the center of the joints, CrB and high Ni contents of ${\gamma}$-Ni was existed. For the joints brazed at a heating rate of $0.38^{\circ}C/min$, the height of filler was decreased from $100{\mu}m$ to $86{\mu}m$ showing the overflow of filler was not appeared. At the center of the joints, only ${\gamma}$-Ni was detected gradating the Ni contents from center. This phenomenon was driven from a diffusion amount of Boron in filler metal. With a fast heating rate $20^{\circ}C/min$, diffusion amount of B was so small that liquid state of filler metal and base metal were reacted. But, for a slow heating rate $0.38^{\circ}C/min$, solid state of filler metal due to low diffusion amount of B reacted with base metal as a solid diffusion bonding.

지중열전도도 측정과 지중열교환기의 열확산 특성 분석 (Measurement of Ground Thermal Conductivity and Characteristics of Thermal Diffusion by the Ground Heat Exchanger)

  • 정영만;구경민;황유진;장세용;이영호;이동혁;이재근
    • 설비공학논문집
    • /
    • 제20권11호
    • /
    • pp.739-745
    • /
    • 2008
  • This paper presents the measurement of ground thermal conductivity and the characteristics of ground thermal diffusion by a ground heat exchanger(GHE). A borehole is installed to a depth of 175 m with a diameter of 150 mm. To analyze the thermal diffusion property of the GHE, thermocouples are installed under the ground near the GHE. The outdoor temperature, the ground temperature, and the water temperature of the GHE are monitored for evaluating the characteristics of ground thermal diffusion. The ground thermal conductivity is evaluated by the in-situ thermal response tester and the line source model. It is found to be 3.08 W/$m^{\circ}C$ in this study. The ground temperature is greatly dependent on the outdoor temperature from the ground surface to 2.5 m in depth and is stable below 10 m in depth. The surface temperature of the GHE varies as a function of the temperature of circulating water. But the ground temperature at 1.5 m far from the GHE is not changed in accordance with the temperature of circulating water.

마그네슘 합금 표면의 지르코니아 분말 레이저 소결과정에서 조사 패턴이 접합 계면 품질에 미치는 영향 (Effect of Laser Processing Patterns on the Bonding Interface Quality during Laser Sintering of Magnesium Alloys with Zirconia)

  • 윤상우;김주한
    • 한국기계가공학회지
    • /
    • 제20권2호
    • /
    • pp.51-57
    • /
    • 2021
  • The quality of the ceramic sintered coating on a metal surface through laser surface treatment is affected by the laser irradiation pattern. Depending on the laser irradiation pattern, the amount of residual stress and heat applied or accumulated on the surface increases or decreases, affecting the thickness attained in the ceramic sintering area. When the heat energy accumulated in the sintering area is high, the ceramic and the metal alloy melt and sufficiently mix to form a homogeneous and thick bonding interface. In this study, the thermal energy accumulation in the region sintered with zirconia was controlled using four types of laser processing patterns. The thickness of the diffusion region is analyzed by laser-induced breakdown spectroscopy of Mg-ZrO2 generated by laser sintering zirconia powder on the magnesium alloy surface. On the basis of the analysis of the Mg and Zr present in the sintered region through LIBS, the effect of the irradiation pattern on the sintering quality is confirmed by comparing and analyzing the heat and mass transfer tendency of the diffusion layer and the degree of diffusion according to the irradiation pattern. The derived diffusion coefficients differed by up to 9.8 times for each laser scanning pattern.

컴팩트형 열교환기의 핀 표면에서 발생하는 경계층이 열교환기의 전열 및 압력강하 특성의 변화에 미치는 영향에 관한 수치해석적 연구 (Effect of Boundary Layer Generated on the fin surfaces of a Compact Heat Exchanger on the Heat Transfer and Pressure Drop Characteristics)

  • 김철호;정지용
    • 한국전산유체공학회지
    • /
    • 제3권1호
    • /
    • pp.82-88
    • /
    • 1998
  • As a par of a project related to the development of the design algorithm of a compact heat exchanger for the application of the electronic home appliances, the effect of the discreteness of the airflow boundary generated on the cooling fin surface on the heat transfer and pressure drop characteristics of the heat exchanger was studied numerically. In general, there are two critical design parameters seriously considered in the design of the heat exchanger; heat transfer rate(Q) and pressure drop coefficient(C/sub p/). Even though the higher heat transfer rate with lower pressure drop characteristics is required in a design of the heat exchanger, it is not an easy job to satisfy both conditions at the same time because these two parameters are phenomenally inversely proportional. To control the boundary layer thickness and its length along the streamline, the surface of the flat fin was modified to accelerate the heat transfer rate on the fin surface. To understand the effect of the discreted fin size(S/sub w/) and its location(S/sub h/) on the performance of the heat exchanger in the airflow field, the flat fin was modified as shown in Fig. 1. From this study, it was found that the smaller and more number of slits on the fin surface showed the higher energy diffusion rate. It means that the discreteness of the boundary layer is quite important on the heat transfer rate of the heat exchanger. On the other hand, if the fin surface configuration is very complex than needed, higher static pressure drop occurs than required in a system and it may be a reason of the induced aerodynamic noise in the heat exchanger.

  • PDF