• Title/Summary/Keyword: Heat Control

Search Result 3,676, Processing Time 0.035 seconds

An Experimental Study on Thermoelectric Generator Performance for Waste Coolant Recovery Systems in Vehicles (자동차 냉각수 폐열회수 열전발전 시스템의 성능에 관한 연구)

  • Lee, Dae-Woong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.7
    • /
    • pp.329-334
    • /
    • 2014
  • This study indicated the possibility of energy regeneration from waste coolant heat, by using thermoelectric generation integrated with heat pipe. The internal combustion engine rejects more than 60% wasteful energy to the atmosphere by heat. The thermoelectric generator has recently been studied, to convert the energy from engine waste heat into electricity. For coolant waste heat recovery, a thermoelectric generator was investigated, to find out the possibility of vehicular application. Performance characteristics were conducted with various test conditions of coolant temperature, coolant mass flow rate, air temperature, and air velocity, with the thermoelectric generator installed either horizontally or vertically. Experimental results show that the electric power and conversion efficiency increases according to the temperature difference between the hot and cold side of the thermoelectric generator, and the coolant flow rate of the hot side heat exchanger. Performance improvement can be expected by optimizing the heat pipe design.

A Study on the Heat pump - Latent Heat Storage System for the Greenhouse Heating (그린하우스 난방을 위한 열펌프-잠열축열 시스템 연구)

  • 송현갑;노정근;박종길;강연구;김현철
    • Journal of Biosystems Engineering
    • /
    • v.23 no.2
    • /
    • pp.147-156
    • /
    • 1998
  • It is desirable to use the renewable energy for the greenhouse heating in winter season, it make possible not only to save fossil fuel and conserve green environment but also to promote the quality of agricultural products and reduce the agricultural production cost. In this study the heat pump - PCM latent heat storage system has been developed to use the natural energy as much as possible for the thermal environment control of greenhouse. The coefficient of performance (COP) of the heat pump system was 3~4 with the ambient temperature ranging from 8$^{\circ}C$ to -8$^{\circ}C$, and greenhouse heating effect of the heat pump-PCM latent heat storage system on the basis of the ambient temperature was about 12-15$^{\circ}C$.

  • PDF

Design Characteristics Analysis for Very High Temperature Reactor Components (VHTR 초고온기기 설계특성 분석)

  • Kim, Yong Wan;Kim, Eung Seon
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.1
    • /
    • pp.85-92
    • /
    • 2016
  • The operating temperature of VHTR components is much higher than that of conventional PWR due to high core outlet temperature of VHTR. Material requirements and technical issues of VHTR reactor components which are mainly dominated by high temperature service condition were discussed. The codification effort for high temperature material and design methodology are explained. The design class for VHTR components are classified as class A or B according to the recent ASME high temperature reactor design code. A separation of thermal boundary and pressure boundary is used for VHTR components as an elevated design solution. Key design characteristics for reactor pressure vessel, control rod, reactor internals, graphite reflector, circulator and intermediate heat exchanger were analysed. Thermo-mechanical analysis of the process heat exchanger, which was manufactured for test, is presented as an analysis example.

Transient Performance of a System Heat Pump with the Variation of Compressor Speed and EEV Openings (시스템 히트펌프의 압축기 주파수 및 전자팽창밸브 개도 변화에 따른 과도성능 특성)

  • Lee, Sang-Hyeok;Choi, Jong Min
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.9 no.3
    • /
    • pp.11-18
    • /
    • 2013
  • Small and medium-size buildings employ a multi-distributed individual air-conditioning system utilizing package air conditioners instead of centralized cooling systems, which can allow easier building management and maintenance along with a diversification of facility use. Inverter driven system heat pumps have been developed to achieve not only easy distribution control allowing free combination of indoor units with different models and different capacities, but also wide applications to an intelligent air conditioning. In this study, the transient performance of a system heat pump was analysed with the variation of compressor speed and EEV openings. The superheat was selected as a control parameter of the system, because the variation of it was consistent with each indoor unit capacity.

The development of microprocessor_based controller for the electrical boiler of heat storage type (축열식 전기보일러용 마이크로프로세서 제어장치개발)

  • Kim, J.S.;Park, J.W.;Joe, K.Y.;Kim, Y.H.
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.250-253
    • /
    • 1989
  • As the necessity of increasing the midnight base load is extensively increased, electric power companies have to increase the demand of midnight electrical power by lowering the electrical charge rate at midnight. One of the most widely used midnight equipments is the heat Storage type's electrical boiler. A Single chip microprocessor controller for the heat-storage type's electrical boiler is developed. This controller call reduce the undesirable peak load at the begining of midnight (i.e.11 P.M.) time band by using backward load control method. Futhermore, this controller enables reservation of heat storge and the effective heating control the field test has been done by use the boiler for 66$m^2$ with the heater of 21KW quality.

  • PDF

Effects of Heat Therapy Given at a Community Heath Clinic on Sleep and Pain in Rural Elders Who Have Osteoarthritis (온열요법이 퇴행성관절염 노인의 통증과 수면에 미치는 효과)

  • Lee, Gi-Suk
    • Journal of Korean Academy of Rural Health Nursing
    • /
    • v.1 no.1
    • /
    • pp.32-39
    • /
    • 2006
  • Purpose: The purpose of this study was to identify how heat therapy influences pain and sleep in rural elders who have osteoarthritis (OA). Method: A non-equivalent control group pretest-posttest design was used. Participants were 61 elderly farmers and they were assigned to an experimental group (31) or control group (30). The participants were living within the district boundaries of a public health clinic in North Choong Chung Province. The research was conducted from April 1, to 28, 2006. Results: The results of this study demonstrate that heat therapy is effective in reducing pain and promoting sleep in rural elders who have osteoarthritis. Conclusion: Heat therapy reduced pain, and improved sleep in rural elders, with osteoarthritis.

Microstructure change of large cast-forged product by heat treatment conditions (열처리 공정이 대형 주단조품의 조직변화에 미치는 영향)

  • Lee, M.W.;Lee, Y.S.;Lee, S.W.;Lee, D.H.;Kim, S.S.;Moon, Y.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.05a
    • /
    • pp.102-106
    • /
    • 2009
  • Thermal energy control is a important factor in a large size casting and forging. Good control of thermal energy makes characteristics and defect of large cast-forged part, such as large sized forged shell. We have studied about not only large size ring forging process and after heat treatment by FEM simulation. Also, changes of temperature and microstructure for forged shell were predicted. Therefore, we can choose the proper heat treatment condition by FEA. The sectional properties confirmed by practical experiment and evaluation have presented possibilities of process design by computational analysis.

  • PDF

An Experiment on Performance Evaluation of a Direct Atomization Type Air Washer System for Semiconductor Clean Rooms (반도체 클린룸용 직접분무식 에어와셔 시스템의 성능평가실험)

  • Yeo, Kuk-Hyun;Yoo, Kyung-Hoon;Tae, Kyung-Eung
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.988-992
    • /
    • 2006
  • In recent semiconductor manufacturing clean rooms, air washers are used to remove airborne gaseous contaminants such as $NH_3,\;SO_x$ and organic gases from outdoor air introduced into clean room. Meanwhile, there is a large quantity of exhaust air from clean room. It is desirable to recover heat from exhaust air and use it to reheat outdoor air. In the present study, an experiment was conducted to investigate the heat recovery and gas removal efficiencies of a direct atomization type heat recovery air washer.

  • PDF

Combined Treatment of Fumaric Acid with Mild Heat to Inactivate Microorganisms on Fresh Spinach during Storage (Fumaric acid와 mild heat의 병합 처리에 따른 시금치의 저장 중 미생물 제어 효과)

  • Son, Hyeon-Jeong;Kang, Ji-Hoon;Oh, Deog-Hwan;Min, Sea Cheol;Song, Kyung Bin
    • Journal of Applied Biological Chemistry
    • /
    • v.59 no.1
    • /
    • pp.69-74
    • /
    • 2016
  • The objective of this study was to examine the combined effect of fumaric acid with mild heat on the inactivation of microorganisms on spinach. Spinach leaves were inoculated with Escherichia coli O157:H7 and Listeria monocytogenes. Based on the results of single treatment of fumaric acid (0.1, 0.3, and 0.5%) or mild heat (40, 50, and $60^{\circ}C$) regarding the inactivation of the inoculated bacteria, the optimal condition for the combined treatment was suggested to be 0.5% fumaric acid and mild heat treatment at $50^{\circ}C$ for 5 min. The combined treatment of fumaric acid with mild heat caused 2.53 and 2.62 log reductions of the populations of L. monocytogenes and E. coli O157:H7, respectively. In addition, during storage of fresh spinach at $4^{\circ}C$ for 12 d, the combined treatment reduced initially the populations of total aerobic bacteria by 2.77 log CFU/g compared with the control. In particular, after 12 d of storage, the population of total aerobic bacteria for the combined treatment sample was 4.84 log CFU/g, whereas the control sample had 6.66 log CFU/g. Color and vitamin C content of spinach samples were not altered significantly by the combined treatment during storage. These results indicate that the combined treatment of fumaric acid with mild heat is an effective method to control microorganisms on spinach during storage.

Physical and Mechanical Properties of Heat-treated Domestic Yellow Poplar (백합나무 열처리재의 물리 및 역학적 특성)

  • Kim, Kwang-Mo;Park, Jung-Hwan;Park, Byoung-Soo;Son, Dong-Won;Park, Joo-Saeng;Kim, Wun-Sub;Kim, Byoung-Nam;Shim, Sang-Ro
    • Journal of the Korean Wood Science and Technology
    • /
    • v.38 no.1
    • /
    • pp.17-26
    • /
    • 2010
  • Recently, yellow poplar (Liriodendron tulipifera L.) is getting attention in Korea due to the fast growing and high yield and quality of lumber. But, it is thought that the color difference between heartwood and sapwood may restrict the practical use of it. This study was aimed to enhance the value of yellow poplar lumber by the color control using high temperature heat-treatment, which had been tried for domestic cedar (Kim et al., 2009). The material properties including surface color of yellow poplar lumber were evaluated according to heat treatment conditions. The difference of color between sapwood and heartwood could be reduced by heat treatment at a temperature about $200^{\circ}C$. Long heating time was more effective in reducing the difference. The Equilibrium Moisture Content (EMC) of heat-treated wood was as low as 50 percent of the control. The result obviously indicates that heat-treated wood is more dimensionally stable in the change of moisture condition. The durability against wood rotting fungi also increased by the heat-treated, but it was not so effective as the case of cedar. The changes of mechanical properties of heat-treated yellow poplar were very similar to that of heat-treated cedar. In order to develop new use of heat-treated yellow poplar, the changes of mechanical properties should be considered. There were no significant changes in microscopic structure which may cause changes in mechanical properties. Further study of heat-treated wood is needed to scrutinize the causes of changes of material properties.