• Title/Summary/Keyword: Heartbeat

Search Result 179, Processing Time 0.022 seconds

The Development of the Smart Sensibility Mat with Kangaroo Mother Care (캥거루 케어를 반영한 스마트 감성 매트의 개발)

  • Cho, Soo-Min
    • Science of Emotion and Sensibility
    • /
    • v.20 no.2
    • /
    • pp.171-178
    • /
    • 2017
  • 'Smart Sensibility Mat (SSM)' was developed and manufactured for positive sensibility of newborn with fiber, digital, and sensibility technology to reflect features and advantages of kangaroo care. For tactile stimuli, the tube of the silicon material to provide a constant temperature of $32^{\circ}C$ was inserted into the mat and connected to the water-thermostat. To provide a uniform temperature throughout the mat, the fabric by the inserting conductive yarn was attached to the mat surface. After wrapping the mat with cotton pad, the polyurethane foam used as medicine in order to similar to the human skin was bonded to the surface of the mat. To provide the auditory stimuli of a level of 30dB with mother's heartbeat sounds and voice recorded in advance, the Bluetooth speaker was inserted into the mat. To investigate the effects of SSM, 10 newborns who born within two weeks were involved in this experiment. While the baby was lying on each of the general mat (GM) and SSM, the baby's physiological signals-heart rate, breathing rate, temperature- were measured and then, those were conducted t-test to examine the difference between the signals of SSM and GM. The results were as follows: heart rate (t=8.131, p<.001) and respiratory rate (t=7.227, p<.001) among the physiological signals of SSM decreased significantly than GM within the normal range. Temperature (t=1.062, p=0.292) at SSM showed a tendency to decrease than GM within the normal range. This means the tactile stimuli and the auditory stimuli providing from SSM give stable physiological responses. Thus, SSM leads to have psychological comfort and stability of newborns.

A Study on the Relations between Yangseng Level and Stress in Industrial Workers (근로자(勤勞者)의 양생수준(養生水準)과 스트레스와의 관계(關係))

  • Ahn, Hun-Mo;Kim, Sung-Sam;Kim, Wan-Gyeom;Yu, Ho-Dal;Chong, Myong-Soo;Lee, Ki-Nam
    • Journal of Society of Preventive Korean Medicine
    • /
    • v.11 no.1
    • /
    • pp.109-129
    • /
    • 2007
  • This study aims at grasping the relativity between laborers' yangseng level and stress so as to present the groundwork for preventive oriental medicine approach in industrial health. The researcher prepared the questionnaire on general character, health-related yangseng level and chose 632 people to execute Autonomic balance test through heartbeat change. The collected material was analyzed by SPSS and tested by T-test, ANOVA. The general yangseng level average is 3.27, morality yangseng 3.91, sleep yangseng 3.39, mind yangseng 3.32, sex life yangseng 3.29, exercise yangseng 3.14, activities and rest yangseng 3.07, diet yangseng 2.95, seasonal yangseng 2.84. The highest is morality yangseng and seasonal yangseng is the lowest. In the aspect of yangseng level : Having a spouse, Non-smoking, Non-drinking, Regular exercising, Sufficient sleeping have higher yanseng levels. In Autonomic balance test, age from 35 to 40 has the highest autonomic activity and job period from 5 years to 10 years has the highest stress resistance. Non-smokers have high autonomic activity and stress resistance. Further, have low autonomic balance, stress index and fatigue strength. In the case of regular exercising person, he/she has high autonomic activity and stress resistance with low stress index. Regarding sleeping time, autonomic balance is the highest when he/she sleeps less than 6 hours. Stress resistance is the highest when he/she sleeps 7 hours and stress index is the highest when he/she sleeps 6 hours. After comparing the relativity between yangseng level autonomic balance test, only exercise yangseng has plus factor on autonomic activity and stress resistance and minus factor on stress ind ex and fatigue strength. Yangseng level has been affected by individual character and daily habits. Also stress is more influenced by daily habits than by individual character. We can find the relativity of exercise yangseng between yangseng and stress which suggests that we need to take measures to win over stress in individual health in the near future.

  • PDF

A 2.4 GHz Bio-Radar System with Small Size and Improved Noise Performance Using Single Circular-Polarized Antenna and PLL (하나의 원형 편파 안테나와 PLL을 이용하여 소형이면서도 개선된 잡음 성능을 갖는 2.4 GHz 바이오 레이더 시스템)

  • Jang, Byung-Jun;Park, Jae-Hyung;Yook, Jong-Gwan;Moon, Jun-Ho;Lee, Kyoung-Joung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.12
    • /
    • pp.1325-1332
    • /
    • 2009
  • In this paper, we design a 2.4 GHz bio-radar system that can detect human heartbeat and respiration signals with small size and improved noise performance using single circular-polarized antenna and phase-locked loop. The demonstrated bio-radar system consists of single circular-polarized antenna with $90^{\circ}$ hybrid, low-noise amplifier, power amplifier, voltage-controlled oscillator with phase-locked loop circuits, quadrature demodulator and analog circuits. To realize compact size, the printed annular ring stacked microstrip antenna is integrated on the transceiver circuits, so its dimension is just $40\times40mm^2$. Also, to improve signal-to-noise-ratio performance by phase noise due to transmitter leakage signal, the phase-locked loop circuit is used. The measured results show that the heart rate and respiration accuracy was found to be very high for the distance of 50 cm without the additional digital signal processing.

Noise Analysis and Measurement for a CW Bio-Radar System for Non-Contact Measurement of Heart and Respiration Rate (호흡 및 심박수 측정을 위한 비접촉 방식의 CW 바이오 레이더 시스템의 잡음 분석 및 측정)

  • Jang, Byung-Jun;Yook, Jong-Gwan;Na, Won;Lee, Moon-Que
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.9
    • /
    • pp.1010-1019
    • /
    • 2008
  • In this paper, we present a noise analysis and measurement results of a bio-radar system that can detect human heartbeat and respiration signals. The noise analysis including various phase noise effects is very important in designing the bio-radar system, since the frequency difference between the received signal and local oscillator is very small and the received power is very low. All of the noise components in a bio-radar system are considered from the point of view of SNR. From this analysis, it can be concluded that the phase noise due to antenna leakage is a dominant factor and is a function of range correlation. Therefore, the phase noise component with range correlation effect, which is the most important noise contribution, is measured using the measurement setup and compared with the calculated results. From the measurement results, our measurement setup can measure a closed-in phase noise of a free-running oscillator. Based on these results, it is possible to design a 2.4 GHz bio-radar system quantitatively which has a detection range of 50 cm and low power of 1 mW without additional PLL circuits.

Smart-Telemedicine System Design and Business Model Analysis for Longitudinal Healthcare (예방의학을 위한 Smart-Telemedicine 시스템과 비즈니스 모델의 설계와 분석)

  • Kim, Chanyoung;Kwon, Dosoon;Lee, Jaebeom;Kim, Jinhwa
    • Information Systems Review
    • /
    • v.14 no.2
    • /
    • pp.1-19
    • /
    • 2012
  • Recently due to the enhancement of education and lifestyle, the trend of healthcare services are changed to a more active and differentiated service in which a continuous self health care is possible. The Smart-Telemedicine system offers medical services by merging Blue-tooth and telecommunication modules to former blood pressure, blood sugar, heartbeat and temperature measuring devices. Moreover, it could analyze one's health pattern which would be helpful for the patient to prevent potential future illness. In addition, the easier accesses to various remote controllable medical check-up programs are offered to public as a number of available smart phone are rapidly escalating. The Smart-Telemedicine system provides the most ideal interactive medical service via accessible smart phones and mobile medical check-up devices at anywhere and anytime. It is very beneficial since it can save patients' time and money because people can reach to the service right at their home and be allowed to take charge of their health care process via longitudinal health data. Therefore, not only social costs that occur in elderly community would be saved, but also business in various forms of medical service field transactions could be possible. This paper will suggest the Smart-Telemedicine System for preventive medicine, its design and analysis of business models and the evaluation of those model.

  • PDF

A Study on the Relations between Yangseng Level and Stress in Industrial Workers (근로자(勤勞者)의 양생수준(養生水準)과 스트레스와의 관계(關係))

  • Ahn, Hun Mo;Kim, Sung Sam;Kim, Wan Gyeom;Yu, Ho Dal;Chong, Myong Soo;Lee, Ki Nam
    • Journal of Korean Medical Ki-Gong Academy
    • /
    • v.10 no.1
    • /
    • pp.100-129
    • /
    • 2007
  • This study aims at grasping the relativity between laborers' yangseng level and stress so as to present the groundwork for preventive oriental medicine approach in industrial health. The researcher prepared the questionnaire on general character, - health-related yangseng level and chose 632 people to execute Autonomic balance test through heartbeat change. The collected material was analyzed by SPSS and tested by T-test, ANOVA The general yangseng level average is 3.27, morality yangseng 3.91, sleep yangseng 3.39, mind yangseng 3.32, sex life yangseng 3.29, exercise yangseng 3.14, activities and rest yangseng 3.07, diet yangseng 2.95, seasonal yangseng 2.84. The highest is morality yangseng and seasonal yangseng is the lowest. In the aspect of yangseng level: Having a spouse, Non-smoking, Non-drinking, Regular exercising, Sufficient sleeping have higher yangseng levels. In Autonomic balance test, age from 35 to 40 has the highest autonomic activity and job period from 5 years to 10 years has the highest stress resistance. Non-smokers have high autonomic activity and stress resistance. Further, have low autonomic balance, stress index and fatigue strength. In the case of regular exercising person, he/she has high autonomic activity and stress resistance with low stress index. Regarding sleeping time, autonomic balance is the highest when he/she sleeps less than 6 hours. Stress resistance is the highest when he/she sleeps 7 hours and stress index is the highest when he/she sleeps 6 hours. After comparing the relativity between yangseng level autonomic balance test, only exercise yangseng has plus factor on autonomic activity and stress resistance and minus factor on stress index and fatigue strength. Yangseng level has been affected by individual character and daily habits. Also stress is more influenced by daily habits than by individual character. We can find the relativity of exercise yangseng between yangseng and stress which suggests that we need to take measures to win over stresses in individual health in the near future.

Time of Initial Detection of the Gestational Structures by Ultrasonography Examination in Small Pet Dogs (소형 애완견에서 초음파 검사에 의한 임신 구조물의 최초 관찰 시기)

  • Park, Sang-Guk;Kim, Bang-Sil;Yun, Chang-Jin;Yeo, Woon-Chang;Park, Chul-Ho;Kim, Jae-Pung;Lee, Suk-Kyung;Moon, Jin-San;Suh, Guk-Hyun;Oh, Ki-Seok;Son, Chang-ho
    • Journal of Embryo Transfer
    • /
    • v.23 no.1
    • /
    • pp.5-11
    • /
    • 2008
  • Serial ultrasonographic examinations were daily performed from 15 days after ovulation until parturition to determine the time of first detection and ultrasonographic appearance of the fetal and extra-fetal structures in pregnant 10 Maltese, 10 Yorkshire Terrier, 15 Shih-tzu, and 10 Miniature Schnauzer bitches, respectively. Gestational age was timed from the day of ovulation (day 0), which was estimated to occur when plasma progesterone concentration was first increased above 4.0ng/ml. The gestational length was $63.4{\sim}63.6$ (range: $61{\sim}65$) days and the geatational length was no statistically significant difference among bitches (p>0.05). The initial detection of the extra-fetal structures were; gestational sac at days $18.9{\sim}19.5\;(17{\sim}22)$, zonary placenta at days $24.6{\sim}25.5\;(23{\sim}28)$, yolk sac membrane at days $24.6{\sim}25.5\;(23{\sim}27)$, yolk sac tubular shape at days $26.1{\sim}26.3\;(24{\sim}28)$, and amniotic membrane at days $26.1{\sim}28.2\;(24{\sim}31)$, respectively. The time of the first detection of the extra-fetal structures were no statistically significant difference among bitches (p>0.05). The initial detection of the fetal structures were; embryo initial detection at days $22.5{\sim}22.9\;(21{\sim}24)$, heartbeat at days $23.2{\sim}23.8\;(21{\sim}25)$, embryo bipolar shape $27.6{\sim}28.9\;(26{\sim}30)$, fetal movement at days $31.9{\sim}32.8\;(27{\sim}34)$, limb buds at days $29.1{\sim}30.7\;(27{\sim}33)$, stomach at days $31.1{\sim}33.1\;(29{\sim}34)$, urinary bladder at days $32.4{\sim}33.2\;(29{\sim}35)$, skeleton at days $34.7{\sim}35.9\;(34{\sim}39)$, and kidney at days $42.1{\sim}44.7\;(41{\sim}48)$, respectively. The the time of the first detection of the fetal structures were no statistically significant difference among bitches (p>0.05). These results indicate the evaluation of the time of first detection and ultrasonographic characteristics of the gestational structures might be useful for pregnancy diagnosis, estimating fetal age, embryonic resorption, fetal monster, abnormal fetal growth and fetal viability, respectively.

The Hearing Ability of Coralfish Chromis notatus to Low Frequency Sound 2. The Auditory Critical Ratio and Hearing Index (저주파음에 의한 자리돔의 청각 능력 2. 청각 임계비 및 청각능력지수)

  • 이창헌;서두옥
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.36 no.4
    • /
    • pp.314-321
    • /
    • 2000
  • In order to obtain the fundamental data on the auditory thresholds of fishes for catching method using low frequency sound, the auditory thresholds of coralfish Chromis notatus were measured in the presence of masking noise in the spectrum level range of 73~83dB re l$\mu$Pa/√Hz by heartbeat conditioning technique using pure tones coupled with a delayed electric shock. Critical ratios were about 23~41dB at measurement frequency, The critical ratio increased almost linearly with increasing frequency from 500Hz. The noise spectrum level at the start of masking was about 60~65dB. This suggests that hearing of coralfish is masked in the natural environment with the noise spectrum level above 60dB. The sound pressure level of which the signal sound of 300Hz is recognized by coralfish under the ambient noise is above 88dB and the critical ratio of them is above 23dB. The hearing index of coralfish with ambient noise was 81.

  • PDF

An Analysis of Consumer Emotion for Product Planning of Smart Clothing (스마트 의류 상품 기획을 위한 감성 효과 분석)

  • Cho, Hyun-Seung;Kim, Jung-Ho;Koo, Hye-Ran
    • Science of Emotion and Sensibility
    • /
    • v.17 no.3
    • /
    • pp.49-56
    • /
    • 2014
  • This study aims at providing basic data for product planning to design smart clothing and to develop applications, focusing on consumers by satisfying their emotions through analyzing emotional factors on smart clothing, comparing emotional differences between conventional clothing and it, reviewing changes of consumers' emotion by integrating the product and clothing and researching differences of preference and purchase intention between smart clothing and traditional one. As the results of the study, emotional factors for smart clothing were analyzed with total 6 including 'technical', 'comfort', 'aesthetic', 'modern', 'fun' and 'multiple' factors. Among them, except for 'comport', five emotional factors showed emotional factors between conventional sport-casual clothing and smart clothing. That is, emotional factors of 'technical', 'aesthetic', 'modern', 'fun' and 'multiple' were emphasized more in smart clothing than conventional ones, indicating that they should be considered in planning products of smart clothing. Though there was no significant difference of preference between smart clothing and conventional clothing, in case of comparison of averages, that of smart clothing was a little higher. For purchase intention, smart clothing was lower than the conventional clothing. So preference seems to be not directly related to consumers' immediate purchase. To make consumers' interests and preference to result in purchase, it is necessary to develop smart clothing with more various applications and to prepare commercializing strategies. As the results of the analysis on free-descriptive questionnaire survey, consumers were interested in development of smart clothing to help diet with functions including energy harvesting from body motion, calorification and perspiration, measurement of motion and calory consumption as well as health-care type smart clothing to measure heartbeat and ECG. Reflecting these requirements from the consumers, they should be utilized as guidance to develop smart clothing in the future.

Programmed-release intraosseus anesthesia as an alternative to lower alveolar nerve block in lower third molar extraction: a randomized clinical trial

  • Pol, Renato;Ruggiero, Tiziana;Bezzi, Marta;Camisassa, Davide;Carossa, Stefano
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.22 no.3
    • /
    • pp.217-226
    • /
    • 2022
  • Background: Intraosseous anesthesia is the process by which an anesthetic solution, after penetration of the cortical bone, is directly injected into the spongiosa of the alveolar bone supporting the tooth. This study aimed to compare the effectiveness of the traditional inferior alveolar nerve block (IANB) and computerized intraosseous anesthesia in the surgical extraction of impacted lower third molars, compare their side effects systemically by monitoring heart rate, and assess patients' a posteriori preference of one technique over the other. Methods: Thirty-nine patients with bilaterally impacted third molars participated in this study. Each patient in the sample was both a case and control, where the conventional technique was randomly assigned to one side (group 1) and the alternative method to the contralateral side (group 2). Results: The traditional technique was faster in execution than anesthesia delivered via electronic syringe, which took 3 min to be administered. However, it was necessary to wait for an average of 6 ± 4 min from the execution to achieve the onset of IANB, while the latency of intraosseous anesthesia was zero. Vincent's sign and lingual nerve anesthesia occurred in 100% of cases in group 1. In group 2, Vincent's sign was recorded in 13% of cases and lingual anesthesia in four cases. The average duration of the perceived anesthetic effect was 192 ± 68 min in group 1 and 127 ± 75 min in group 2 (P < 0.001). The difference between the heart rate of group 1 and group 2 was statistically significant. During infiltration in group 1, heartbeat frequency increased by 5 ± 13 beats per minute, while in group 2, it increased by 22 ± 10 beats per minute (P < 0.001). No postoperative complications were reported for either technique. Patients showed a preference of 67% for the alternative technique and 20% for the traditional, and 13% of patients were indifferent. Conclusion: The results identified intraosseous anesthesia as a valid alternative to conventional anesthesia in impacted lower third molar extraction.