• Title/Summary/Keyword: Heart-lung transplantation

Search Result 46, Processing Time 0.033 seconds

Bilateral Sequential Lung Transplantation in Dogs (황견에서 동종 순차적 양측 폐이식 수술에 관한 연구)

  • 이두연;김해균;문동석;윤용한;홍윤주;이성수
    • Journal of Chest Surgery
    • /
    • v.31 no.2
    • /
    • pp.108-112
    • /
    • 1998
  • Experimental trials of unilateral lung transplantation in dogs have been attempted and satisfactory results were obtained without any noticeable difficulty in surgical techniques. Fourteen dogs with the body weight of around 25 kg were anesthesized by 20~30 mg/kg of intravenous Entobar,; one was sacrificed to make available blood for use during transplantation for the recipient dog. A mid-sternotomy incision was performed and 20 mg/kg of Prostaglandin E1 was infused through the pulmonary artery and Euro-Collin's(E-C) preservation solution, cooled down to 4$^{\circ}C$, was perfused at the rate of 70cc/kg by a pressure of 30 cmH2O. The heart-lung block was then resected out and promptly immersed in the prepared preservation solution at 4$^{\circ}C$. One lung preserved in the EC solution at 4$^{\circ}C$ was anastomosed to the recipient dog in the order of the pulmonary vein, bronchus then pulmomary artery and the thoracotomy incision was closed after the bleeding control and tube thoracostomy. Then the pneumonectomy in the opposite side was perfomed in the same manner and the tailored lung was transplanted in the order of the pulmonary vein, bronchus, then pulmonary artery. We conclude that in the bilateral sequential lung transplantation, the right lung transplantation should precede to better expose the operative field and to prevent reperfusion injury; also, the cardiopulmonary bypass should be consider for certain appropriate cases.

  • PDF

Gastrointestinal Complications after Lung Transplantation (폐이식 후 발생한 소화기계 합병증)

  • Haam, Seok-Jin;Paik, Hyo-Chae;Kim, Ji-Hyun;Lee, Doo-Yun;Kim, Chang-Wan;Kim, Jung-Hwan
    • Journal of Chest Surgery
    • /
    • v.43 no.3
    • /
    • pp.280-284
    • /
    • 2010
  • Background: The postoperative management following lung transplantation has dramatically improved in the recent decade. However, some complications still remain as troublesome problems. We retrospectively reviewed the gastrointestinal complications and their management after lung transplantation. Material and Method: We performed a retrospective review of the medical records of 25 cases in 23 patients who underwent lung and heart-lung transplantations from July 1996 to March 2009. The definition of gastrointestinal complication was the gastrointestinal tract-related disease that occurred after lung transplantation. There were eight postoperative deaths (within postoperative 30 days) that were excluded from the analysis. Result: Twenty three gastrointestinal complications occurred in 11 (64.7%) of the 17 cases. The median follow-up period was 6.9 months (range: 2 months to 111 months), and chronic gastritis (23.5%, 4 of 17 cases) was the most common complication. Severe, prolonged (more than 2 weeks) diarrhea occurred in 3 cases. Three patients had gastric ulcer with one case requiring gastric primary closure for gastric ulcer perforation. This patient had gastric bleeding due to recurrent gastric ulcer 2 months after laparotomy. Cytomegalovirus gastritis and esophagitis occurred in 2 cases and 1 case, respectively, and esophageal ulcer occurred in 2 cases. There were esophageal strictures in 2 patients who underwent esophageal stent insertion. Other complications were one case each of ileus, early gastric cancer requiring endoscopic mucosal resection, gall bladder stone accompanied with jaundice, and pseudomembranous colitis. Conclusion: The incidence of gastrointestinal complication is relatively high in patients after they undergo lung transplantation. Since gastrointestinal complications can induce malnutrition, which might be related to considerable morbidity and mortality, close follow-up is necessary for the early detection and proper management of gastrointestinal complications.

Congenital Pulmonary Vein Stenosis with Normal Anatomical Connection -One case report- (정상적인 해부학적 연결을 가진 선천성 폐정맥 협착증 -치험 1예 보고-)

  • 박준석;장윤희;정미진;강이석;전태국
    • Journal of Chest Surgery
    • /
    • v.37 no.4
    • /
    • pp.364-368
    • /
    • 2004
  • Congenital pulmonary vein stenosis is a rare anomaly and related to high mortality due to progressive pulmonary hypertension and heart failure in infancy. Aggressive anti-failure medication and surgical treatment is recommended. Surgical options are balloon dilatation, endovascular stent, pneumonectomy, lung transplantation, patch grafting, and sutureless repair. We report a case of congenital pulmonary vein stenosis with normal anatomical connection successfully treated with sutureless technique and using pulmonary vasodilators, such as Sildenafil, lloprost and iNO postoperatively.

Postcaroiomy Heart or Heart/Lung Assist Experiences in Children (소아연령의 개심술후 시행한, 심장 혹은 심장-폐 순환보조장치의 임상적 고찰(Royal Children's Hospital, Australia의 경험))

  • 한재진
    • Journal of Chest Surgery
    • /
    • v.27 no.12
    • /
    • pp.977-983
    • /
    • 1994
  • From April 1989 to December 1993, total 39 patients who were unable to be weaned off CPB or expected fatal immediate postoperiatively, were treated with ventricular assist device [VAD] or extracorporeal membrane oxygenator[ECMO] at the Royal Children`s Hospital, Melbourne. Ages ranged from 3 day to 19.4 year old and body weights from 2.0Kg to 70Kg. Twenty-seven[69.2%] of 39 patients were weaned to be decannulated successfully and sixteen[41.0%] survived to hospital discharge and late survival rate was twelve[30.8%] of 39 patients. The total follow-up period was 4 to 56 months [32.92$\pm$20.77months] and most of the late survivals showed good myocardial recovery state. From the viewpoint of the assist modality, 29 patients were treated with VAD and among them, 23 were weaned from assist successfully, but among the 8 ECMO patients, only 3 could be weaned, and both modalities were performed to the 2 patients with one weaned. The total duration of assist was from 8 to 428 hours and there was a significant difference between hospital discharged group and hospital death group, which were 83.13$\pm$31.29 hours vs 147.52$\pm$112.03 hours[P=0.032]. Conclusively, at the critical postcardiotomy situation of the paediatrtic patients including various congenital complex disease and procedures, we can choose this VAD or ECMO treatment strategy as the reasonable life saving way except transplantation.

  • PDF

Protective Effect of Nitroglycerin on the Ischemia-Reperfusion Model of the Isolated Rat Lung (흰쥐의 분리 폐장 관류 모델에서 Nitroglycerin의 폐장 보존 효과)

  • Jheon, Sang-Hoon;Lee, Sub;Lee, Jong-Hoon;Son, Bok-Kyoung;Cho, Gong-Rae;Chung, Jin-Yong;Cho, Soung-Kyung;Kim, Bong-Il;Lee, Young-Man;Choh, Joong-Haeng
    • Journal of Chest Surgery
    • /
    • v.36 no.12
    • /
    • pp.894-903
    • /
    • 2003
  • Protection against ischemia-reperfusion injury is crucial for successful transplantation of the lung. It has been known that nitric oxide has many favorable effects on the donor lungs but at the same time, has some potential side effects of cytotoxicity. In this regards, we investigated whether the administration of nitroglycerin could decrease ischemia-reperfusion injury in isolated rat lung reperfusion model for the confirmation of the effect of nitroglycerin, a donor of nitric oxide, on lung transplantation. Material and Method: 35 Sprague-Dawley species male white rats were used for this experiment. For nitroglycerin group (n=18), nitroglycerin was administered intravenously followed by mixed in flushing solution for preservation. As a control group (n=17), we used the same amount of normal saline. To evaluate the effect of nitroglycerin on the lung, heart-lung block was obtained, weighed and stored in University of Wisconsin Solution at 1$0^{\circ}C$ for 24 hours. In each group of the isolated lungs, reperfusion was carried out with Krebs-Hensleit-diluted human blood for 60 minutes. As parameters of the state of the isolated lung, peak inspiratory and pulmonary arterial pressures were continuously recorded. Oxygen and carbon dioxide tension of reperfusing blood were measured before and after 30, 60 minutes of reperfusion. After sixty minutes of reperfusion, protein content in bronchoalveolar lavage fluid was measured also for the evaluation of the degree of alveolar flooding. Lung myeloperoxidase activity was determined to verify the accumulation of neutrophils. Results: Although statistically significant differences were not noted in peak inspiratory and pulmonary arterial pressure between control and nitroglycerin group, latter group showed lowering tendency of pulmonary arterial pressure during the entire reperfusion period. Oxygen tension was higher (p<0.05) in nitroglycerin group compared with that of the control group, in contrast, there were no differences in carbon dioxide tension, protein content in bronchoalveolar lavage fluid and myeloperoxidase activity between the groups. In the examination of ultrastructural changes, nitroglycerin denoted the protective effect on the pulmonary architecture compared with that of control group. Conclusion: Collectively, on the bases of these experimental results, prior treatment of donor lung with nitroglycerin could result in better preservation of the lung. Consequently, these nitroglycerin preserved lungs are thought to be more suitable for successful transplantation of the lung.

Effect of Recovery of Pulmonary Function in Hypothermic Lung Preservation (肺의 低溫保存法이 肺機能 回復에 미치는 영향)

  • Lee, Man Bok;Kim, U Jong;Gang, Chang Hui;Lee, Gil No
    • Journal of Chest Surgery
    • /
    • v.30 no.3
    • /
    • pp.253-253
    • /
    • 1997
  • Hypothermia during lung preservation decreases metabolic processes. After the rabbit lung was flushed with modified Euro-Collins solution, heart-lung block was harvested and the left lung was assessed after ligation of the right pulmonary artery and right main-stem bronchus. Heart-lung block was immersed in the same solution for 6 hours. The modified Euro-Collins solution and storage temperature of group 1(10 cases) was 4t, roup 2(10 cases) was l0℃. On completion of the storage period, the left lung was ventilated and reperfused with blood u:high used a cross-circulating paracorporeal rabbit as a "biologic deoxygenator" for 60 minutes. Pulmonary artery pressure, airway pressure, difference in oxygen tension between mow and outflow perfusate and degree of pulmonary edema were assessed at 10-minute intervals while the left lung was ventilated at 0.8 of the inspired oxygen fraction. The mean pulmonary venous oxygen tensions at 10 and 60 minutes after reperfusion were 209.52±42.46 and 103.48± 15.96 mmHg in group I versus 247.78±36.19 and 147.91 ± 11.07 mmHg in group II(p=0.049, (0.0001). The mean alveolar-arterial oxygen differences at 20 and 60 minutes after reperfusion were 357. 95± 12.84 and 437.31 14.26 mmHg in group I versus 310.88±3).47 and )90.93± 15.86 mmHg in group II (p=0.0092, (0.0001). The mean pulmonary arterial pressures at 10 and 60 minutes after reperfusion were 40.56± 18.66 and 87. 2± 17.22 mmHg in group I versus 31.22±6.84 and 65.78± 11.02 mmHg in group rl (p : 0.048, 0.0062). The mean pulmonary vascular resistances at 10 and 60 minutes after reperfusion were 2.69±0.85 and 4.36±0.86 mmHg/ml/min in group I versus 1.99±0.39 and 3.29±0.55 mmHg/ml/min in group II(p : 0.0323, 0.0062). There were no difference between groups in peak airway pressure, lung compliance and degree of pulmonary edema. In conclusion that preservation of lung at l0℃ was superior to preservation at 4℃.

Serum Leakage Control using PP/PDMS Composite Membrane (PP/PDMS 복합막을 이용한 혈청누출 제어)

  • 김기범;이삼철;정순량;정경락
    • Membrane Journal
    • /
    • v.10 no.1
    • /
    • pp.47-53
    • /
    • 2000
  • The artificial lung is a device used to replace the function of the lungs. The major function of the lung is to remove carbon dioxide from the venous blood and replace it with oxygen, or arterialize the blood. And the function of the artificial lung is to provide an adequate amount of oxygenated blood to all the tissues of body during the open heart surgery. Extracorporeal life support(ECLS or ECMO) is standard treatment for severe respiratory failure but poses many contributions to future lung transplantation. Artificial Lung or membrane oxygenators available today, based on microporous polypropylene fibers, are associated with two major problems. They require systemic anticoagulation of the patient and they allow serum leakage across the membrane from the blood side to the gas side during long-term use. We obtained newly fabricated polypropylene(PP)/polydimethylsiloxane(PDMS) membranes which combined PP membrane, a microporous support layer with PDMS, and we had investiaged a technique for minimizing serum lekage of polypropylene(PP) membrane. The gas permeability of each PP/PDMS membrane was almost constant before and after the whole blood test by Lee-White method, while that of PP membrane was significantly reduced. Therefore the PP/PDMS membrane could be prevented serum leakage of PP membrane. In addition, the gas permeability of $CO_2$ in PP/PDMS membrane was 11.5 times higher as compared with that of $O_2$.

  • PDF

A Case of Kartagener's Syndrome Presenting as Respiratory and Right Heart Failures (호흡부전과 우심부전을 동반한 Kartagener 증후군 1예)

  • Yang, Suck-Chul;Lee, Kyung-Sang;Yoon, Ho-Joo;Shin, Dong-Ho;Park, Sung-Soo;Lee, Jung-Hee;Park, Choong-Ki
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.2
    • /
    • pp.251-256
    • /
    • 1996
  • Kartagener's syndrome, a congenital disease transmitted as an autosomal recessive illness with a prevalence of approximately 1:20,000 persons, is characterized by the triple association of situs inversus, bronchiectasis, and sinusitis. Affected persons have an incoordination of ciliary motility that leads to defective mucociliary transport, chronic bronchial infections. Kartagener's syndrome is a subset of the immotile cilia syndrome and therefore all patients with Kartagener's syndrome have immotile cilia with obvious ultrastructural defects in the ciliary axoneme. In the respiratory tract this inability presumably causes impaired clearance of mucus and inhaled particles and results in the chronic infections of the sinuses and bronchial trees that are characterized of the disease. The end-stage phenomenon in Kartagener's syndrome, respiratory or heart failure is a less common event and heart-lung transplantation is becoming an accepted therapy for patients with end-stage pulmonary disease in Kartagener's syndrome in many institutes. We report one case of Kartagener's syndrome in a 25-year-old young woman who was presented as respiratory and right heart failures, with review of literatures.

  • PDF

Health Damages and Lessons of the Use of Humidifier Disinfectants in Korea (가습기살균제 피해사건과 교훈)

  • Choi, Ye-Yong;Lim, Heung-Kyu;Lim, Sin-Ye;Paek, Do-Myung
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.2
    • /
    • pp.166-174
    • /
    • 2012
  • Introduction: After 17 years since the first production of humidifier disinfectants in Korea, Korea Centers for Disease Control and Prevention (KCDC) announced that the odds ratio of lung injury related with humidifier disinfectant usage was 47.3 (95% confidence interval 6.0-369.7) according to a case-control study with 18 adult cases, including 8 pregnant women at a university hospital in Seoul. Results: From September 2011 to April 2012, one-hundred and seventy four victim cases have been reported to an environmental non-governmental group (NGO). We summarized timetable of humidifier disinfectants accidents, analyzed health outcomes (death, lung or lung and heart transplantation, pulmonary disease) of reported victims, and classified some information for humidifier disinfectants with health outcomes, and government action for this accident. Among the victims, number of death cases are 52 (30.0%), including 26 babies less than 3 years old. Sixty-nine victims come from twenty-seven family with 2 to 4 members per family. About twenty types of humidifier disinfectant products and about 600,000 product items a year have been sold. Fifty-two death cases used 7 different types of disinfectant products, including imported goods and some private brands of well-known supermarkets. KCDC confirmed inhalation toxicity of 6 products through an animal experimental test, and based on this observation recalled disinfectants containing PHMG (polyhexamethylene guanidine) and PGH (Oligo(2-(2-ethoxy)ethoxyethyl guanidinium chloride). Discussions: The use of these biocides involved highly fatal consequences among biologically vulnerable victims, such as pregnant women, several family member victims after semi-acute exposure. This is the first biocide disaster in Korea with non-specific targets, and unknown scale of victims, warranting concerns on use of biocides in the living environment. Conclusions: Special administrative agency for chemical safety and compensation act for environmental health victims are needed to prevent similar problems.

Interhospital Transport System for Critically Ill Patients: Mobile Extracorporeal Membrane Oxygenation without a Ventilator

  • Yeo, Hye Ju;Cho, Woo Hyun;Park, Jong Myung;Kim, Dohyung
    • Journal of Chest Surgery
    • /
    • v.50 no.1
    • /
    • pp.8-13
    • /
    • 2017
  • Background: Extracorporeal membrane oxygenation (ECMO) has been successfully used as a method for the interhospital transportation of critically ill patients. In South Korea, a well-established ECMO interhospital transport system is lacking due to limited resources. We developed a simplified ECMO transport system without mechanical ventilation for use by public emergency medical services. Methods: Eighteen patients utilized our ECMO transport system from December 2011 to September 2015. We retrospectively analyzed the indications for ECMO, the patient status during transport, and the patient outcomes. Results: All transport was conducted on the ground by ambulance. The distances covered ranged from 26 to 408 km (mean, $65.9{\pm}88.1km$) and the average transport time was $56.1{\pm}57.3minutes$ (range, 30 to 280 minutes). All patients were transported without adverse events. After transport, 4 patients (22.2%) underwent lung transplantation because of interstitial lung disease. Eight patients who had severe acute respiratory distress syndrome showed recovery of heart and lung function after ECMO therapy. A total of 13 patients (70.6%) were successfully taken off ECMO, and 11 patients (61.1%) survived. Conclusion: Our ECMO transport system without mechanical ventilation can be considered a safe and useful method for interhospital transport and could be a good alternative option for ECMO transport in Korean hospitals with limited resources.