• Title/Summary/Keyword: Heart valves

Search Result 231, Processing Time 0.03 seconds

Analysis and Improvement of System Efficiency for the Moving-actuator type Bi-Ventricular Assist Device ($AnyHeart^{TM}$) (한국형 양심실 보조 인공 심장의 효율 분석 및 개선에 관한 연구)

  • Chung, J.H.;Nam, K.W.;Choi, S.W.;Lee, J.J.;Park, C.Y.;Kim, W.E.;Choi, J.S.;Min, B.G.
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.5
    • /
    • pp.449-458
    • /
    • 2001
  • This is a test report of system efficiency for the moving-actuator type Bi-ventricular assist device (AnyHear $t^{MT}$ ) Seoul National University). $AnyHeart^{TM}$), as an energy converter. utilities a brushless DC motor(S/M 566-26A. Sierracin/ Magnedyne, Carlsbad, CA. U.S.A.) generating their pendulous motion in the epicyclic gear train. It is necessary to know about the overall efficiency of the system. The system is subdivided into three parts: motor part, actuator part and blood sac part (including valves, etc.) according to system mechanism. The motor was operated with a variable range of torque. angular speed and width of voltage Pulse In this report. $AnyHeart^{TM}$ is focused on the efficiency of the motor and actuator parts. 4 $\ell/min$ pump output. which is normal condition of $AnyHeart^{TM}$ system, the total system efficiency is 8%, which is composed of 50%, 85% and 17% efficiency (motor Part, actuator Part and blood sac Part) respectively. In the analyzed result. applied input voltage on normal condition of $AnyHeart^{TM}$ is determined. Also speed Profile with considering filling state of blood sac is Provided. In the test of the in vitro mock circulation. some experimental results are Provided to demonstrate the effectiveness of the Presented approach.

  • PDF

Annual report of thoracic and cardiovascular surgery in Korea [II] (흉부외과 진료통계( II ) -1992년-)

  • Sun, Kyung;Kwak, Young-Tae;Kim, Hyoung-Mook
    • Journal of Chest Surgery
    • /
    • v.26 no.3
    • /
    • pp.163-169
    • /
    • 1993
  • This is the result of the annual statistic analysis of thoracic and cardiovascular surgical cases in 1992 Korea. Overall 17, 520 cases of surgery [11, 732 cases of thoracic surgery by 54 institutes / 5, 788 cases of cardiovascular surgery by 48 institutes] were done. 1. Tumor [N=2, 532] : Lung was the most frequently involved organ by tumor [54.9%],and the remainders were mediastinum [16.2%] / esophagus [14.8%] / chest wall [11.7%] / tracheobronchus [1.3%] / pleura [1.1%] in order. Of 1, 082 cases of primary lung cancer surgery,the frequency of cell type was squamous [62.6%] / adeno [21.6%] / small cell [7.1%] / large cell [2.7%]. Of 411 cases of mediastinal tumor surgery,the frequency of cell type was neurogenic [28.8%] / thymoma [27.6%] / teratoma [17.7%] / congenital cystic [17.2%]. Of 376 cases of esophageal tumor surgery,primary cancer were the most [85.4%]. 2. Infection [N=3, 157] : Pleura was the most frequently involved organ [59.0%],and the remainders were lung [31.3%] / chest wall [8.6%] / mediastinum [1.1%] in order. 3. Miscellaneous [N=6, 043] : Lung and pleural disease esp. pneumothorax [85.1%] was the most frequent surgical indication. The remainders were chest wall anomaly [3.4%] / benign esophageal disease [3.4%] / diaphragmatic pathology [2.4%] / myasthenia [1.4%] in order. Of 85 cases of thymectomy for myasthenia gravis,thymoma was noted in 58.8%. 1. Congenital heart disease [N=3, 363] : The ratio of noncyanotic to cyanotic heart disease was 3:1. Of 2, 516 cases of noncyanotic heart disease,the frequency of disease entity was VSD [44.1%] / ASD [26.0%] / PDA [19.4%] / PS [3.3%],and that of 847 cases of cyanotic heart disease was TOF [29.4%] / ECD [15.6%] / TGA [9.7%] / DORV [7.6%]. Overall mortalities were 2.1% in noncyanotic and 12.2% in cyanotic heart surgery. 2. Acquired heart disease [N=1, 929] : Of 1, 422 cases of valvular surgery,single mitral pathology was the most frequent candidate [48.0%],and total 1, 574 prosthetic valves which were mainly mechanical [95.6%] were used. Of 376 cases of coronary surgery,triple vessel was the most [35.9%],and the frequency of bypassing grafts was great saphenous vein [52.9%] / internal mammary artery [44.7%] / artificial vessel [2.4%]. Overall mortalities were 3.4% in valvular and 4.5% in coronary surgery. 3. Pericardium,Cardiac tumor,Arrhythmia,Aortic aneurysm,Assist device,and Pacemaker : There were no specific changes compared to previous survey1]. This nation-wide inquiry will be continued and reported annually by KTCS Society.

  • PDF

Trends in Heart Valve Surgery in Korea: A Report from the Heart Valve Surgery Registry Database

  • Choi, Jae Woong;Kim, Joon Bum;Jung, Yoo Jin;Hwang, Ho Young;Kim, Kyung Hwan;Yoo, Jae Suk;Lee, Sak;Lee, Seung Hyun;Sung, Kiick;Je, Hyung Gon;Lim, Mi Hee;Chang, Byung-Chul;Hong, Soon Chang;Lee, Heemoon;Shin, Yoon Cheol;Kim, Jae Hyun;Lim, Cheong
    • Journal of Chest Surgery
    • /
    • v.55 no.5
    • /
    • pp.388-396
    • /
    • 2022
  • Background: In this study, we present recent trends in heart valve surgery in Korea through analyses of data from the Korea Heart Valve Surgery Registry (KHVSR). Methods: We enrolled 8,981 patients who were registered in the KHVSR from 2017 to 2020. Yearly trends in patients' baseline characteristics, surgical profiles, and early mortality rates were explored. The observed/expected mortality ratio (O/E ratio), calculated from the actual mortality in the KHVSR and the predicted mortality estimated using the EuroSCORE II, was also analyzed. Results: The proportion of aortic valve surgery significantly increased from 56.8% in 2017 to 60.3% in 2020. The proportion of all combined procedures and minimally invasive surgery significantly increased over the 4-year study period. The operative mortality rate was 2.9% in the entire cohort, while mitral valve repair showed the lowest mortality risk (0.9%). The mortality rates of isolated aortic valve replacement (AVR) significantly decreased from 2.1% in 2017 to 0.8% in 2020 (p=0.016). Overall, the O/E ratio was 0.784 (95% confidence interval [CI], 0.677-0.902) demonstrating significantly lower actual mortality risks than expected based on the EuroSCORE II. In particular, the O/E ratios were as low as 0.364 (95% CI, 0.208-0.591) for isolated AVR. Conclusion: The recent data from the KHVSR showed increasing trends for complex procedures and minimally invasive surgery in heart valve surgery in Korea, and demonstrated remarkably low risks of operative mortality.

Clinical Results of Double Mitral and Aortic Valve Replacement (승모판과 대동맥판의 중복치환수술의 임상적 평가)

  • 김종환
    • Journal of Chest Surgery
    • /
    • v.18 no.1
    • /
    • pp.54-61
    • /
    • 1985
  • One-hundred-and-seven patients were the consecutive cases of double replacement of the mitral and the aortic valves at the same time using the lonescu-Shiley bovine pericardial xenograft valve during the period between May, 1979 and June, 1984. They were 64 males and 43 females, and their ages ranged from 13 to 62 years [mean age, 34.011.9 years]. Eight patients died within 30 days after surgery [operative mortality rate, 7.5%], and 7 others thereafter [late mortality rate, 6.5%; or 4.21%/patient-year]. Ninety-nine early survivors were followed up for a total duration of 166.1 patient-years [mean duration, 20.116.1 months]. Two patients experienced thromboembolic complication with no death [1.20%/patient-year]; five developed prosthetic valve endocarditis [3.01%/patient-year] with one death; and three had a new development of aortic regurgitant murmur and they were, along with a mortality from endocarditis, classified into the cases of tissue valve failure [2.41%/patient-year]. The actuarial survival rate including the operative mortality was 82.24.7% at 6 years after surgery. The probabilities of freedom from thromboembolism and from valve failure were 97.61.7% and 88.67.6% at 6 years respectively. Symptomatic improvement was excellent in most of the cases at the follow-up end, showing the mean of the postoperative NYHA Classes of 1.120.33 from the preoperative one of 2.860.54. These results compares favorably with the ones reported from the major institutions. Clinical results of isolated replacement of the mitral valve and of the aortic valve were previously reported. The clinical results of a total and consecutive patients with replacement of single mitral and single aortic and double mitral and aortic valves on the mortality rate, survival rate, complication frequency, and symptomatic improvement all fully stands for the good therapeutic modalities of the valvular heart diseases with severely damaged lesions.

  • PDF

Clinical Midterm Results of Surgical Aortic Valve Replacement with Sutureless Valves

  • Soonchang Hong;Jung-Woo Son;Yungjin Yoon
    • Journal of Chest Surgery
    • /
    • v.57 no.3
    • /
    • pp.255-262
    • /
    • 2024
  • Background: Sutureless aortic valves may enable shorter procedure times, which benefits patients with elevated surgical risk. We describe the outcomes of patients with aortic stenosis who underwent aortic valve replacement (AVR) using the sutureless Perceval aortic bioprosthesis. Methods: Data from a retrospective cohort were obtained from a clinical database. The study enrolled patients with symptomatic severe aortic stenosis who underwent surgical AVR with a sutureless bioprosthesis between August 2015 and December 2020. In total, 113 patients were included (mean age, 75.3±8.4 years; 57.5% women; median Society of Thoracic Surgeons score, 9.7%; mean follow-up period, 51.19±20.6 months). Of these patients, 41 were octogenarians (36.2%) and 3 were nonagenarians (2.6%). Transthoracic echocardiography was employed to assess changes in ejection fraction (EF), left ventricular mass index (LVMI), and mean pressure gradient (MPG). Results: The in-hospital mortality rate was 2.6%, and 13 patients developed new-onset atrial fibrillation. A permanent pacemaker was implanted in 3 patients (2.6%). The median intensive care unit stay was 1 day (interquartile range [IQR], 1-2 days), and the median hospital stay was 12 days (IQR, 9.5-15 days). The overall survival rate at 5 years was 95.9%. LVMI and MPG were reduced postoperatively, while EF increased over the follow-up period. No structural valve deterioration was observed, and no meaningful paravalvular leakage developed during follow-up. Conclusion: The use of a sutureless valve in the aortic position is safe and feasible, even for high-risk elderly patients requiring surgical AVR. LVMI and MPG decreased postoperatively, while EF increased over the follow-up period.

Postoperative Echocardiographic Hemodynamic Comparison between Recently Available Bileaflet Mechanical Valves (수종의 기계판막치환후 초음파심음향도를 이용한 판막간의 혈류역학적 비교)

  • Kang Joon Kyu;Hong Joon Hwa;Kim Hyung Tai;Park In Duk;Lee Cheol Joo
    • Journal of Chest Surgery
    • /
    • v.38 no.7 s.252
    • /
    • pp.496-500
    • /
    • 2005
  • There was no difference between the bileaflet mechanical valves on the midterm and longterm clinical outcome. We reviewed the hemodynamic comparison between recently available mechanical valves by Doppler Echocardiography. Material and Method: We retrospectively reviewed 396 postoperative hemodynamic datas (EOA, MDPG, and MSPG) by doppler echocardiography in 345 patients. Mechanical valves from 5 venders (Sorin Bicarbon, SJM, ATS, On-X, and Edward MIRA) were compared. There were 232 valves in mitral position, 162 in aortic, and 2 in tricuspid. Result: There were 178 men (mean age; $50.6\pm13.9$ years old) and 167 women $(52.6\pm,4.6)$. MDPG/EOA of 27 mm in mitral position was Sorin; $4.2\pm1.5 mmHg/3.0\pm0.9cm^2,\;SJM;\;2.3\pm1.2/3.5\pm0.6$. In 29mm, Sorin, SJM, ATS, On-X, MIRA revealed $3.4\pm1.2/3.1\pm0.6,\;3.3\pm1.1/2.7\pm0.4,\;3.8\pm0.8/3.2\pm0.6,\;4.0\pm3.0/3.1\pm0.9,\;2.9\pm0.9/3.0\pm0.8$ In 31mm, Sorin, SJM, ATS, MIRA revealed $3.9\pm1.9/2.9\pm0.6,\;3.5\pm1.2/3.0\pm0.6,\;3.4\pm0.8/2.8\pm0.2,\;3.7\pm1.5/2.7\pm0.7$. In 33mm, Sorin, SJM, MIRA revealed $4.4\pm0.9/2.5\pm0.4,\;3.4\pm1.5/3.3\pm0.5,\;4.7\pm2.4\3.0\pm0.3$. MSPG/EOA of 19mm aortic position was Sorin, SJM, ATS, On-X, MIRA $18.0 mmHg/1.2cm^2,\;25.6\pm8.7/1.1\pm0.3,\;25.9\pm12.6/1.2\pm0.3,\;23.0/1.3,\;27.9\pm7.1/1.2\pm0.1$ in that order. In 21mm, SJM, ATS, On-X, MIRA revealed $18.3\pm6.7/1.5\pm0.5,\;13.7\pm2.1/1.7\pm0.3,\;17.0/1.4,\;17.1\pm5.5/1.8\pm0.5$. In 23mm Sorin, SJM, ATS, On-X, MIRA revealed $14.0\pm4.6/1.7\pm0.6,\;12.8\pm3.2/2.0\pm0.2,\;16.8\pm12.2/2.1\pm0.9,\;14.0/1.5,\;15.0\pm5.5/1,8\pm0.5$. In 25mm, SJM and MIRA revealed $14.0\pm5.1/1.8\pm1.0,\;11.0/2.3$. There was no statistically significant difference in these values between the venders given the same position and size. 2 redo valve replacements were performed, 1 due to severe hemolysis in ATS and 1 due to leaflet immobilization in SJM. Conclusion: Postoperative hemodynamic comparison by doppler echocardiography shows no statistically significant difference between recently available mechanical valves in this country.

Valve Replacement in Children (소아심장판막치환술)

  • 김재현;이광숙;윤경찬;유영선;박창권;최세영
    • Journal of Chest Surgery
    • /
    • v.32 no.4
    • /
    • pp.341-346
    • /
    • 1999
  • Background: Thirty children ranging from 3 to 15 years of age underwent cardiac valve replacement at Dongsan Medical Center from 1982 to 1997. Material and Method: There were 16 boys and 14 girls. The mean age was 12.1. The underlying pathological cause for valve replacement was congenital heart disease in 17 children and acquired heart disease in 13. The valve replaced was mitral in 15 children, aortic in 11, tricuspid in 3, and combined aortic and mitral in 1. Twenty-one mechanical and 10 tissue valves were placed: primary mechanical valve have been utilized since 1985. Eight of ten patients with tissue valves have had successful second valve replacements 4 to 11 years after the initial operation. Result: The operative mortality was 6.7%, but mortality was higher among patients less than 5 years of age and patients who had previous cardiac operations. Of the 28 operative survivors, 4 patients were lost to follow-up: the remaining patients were observed for a total of 2091 patient/months(mean 74.7 months, maximum 187 months). There was one late death from dilated cardiomyopathy after mitral valve replacement in 7 year-old patient with atrioventricular septal defect. After the operation, all patients with mechanical valves were placed on a strict anticoagulant regimen with Coumadin. The actuarial survival rate was 96% at the end of the follow-up. No instance of thromboembolism or major bleeding were observed in the survivors. Conclusion: These results indicate that valve replacement can be performed with low mortality in children, and with satisfactory long-term survival.

  • PDF

Long-Term Clinical Results with the St. Jude Medical Cardiac Valve Prosthesis (St. Jude Medical판막치 환술의 장기 임상성적)

  • 김윤규;류지윤
    • Journal of Chest Surgery
    • /
    • v.29 no.9
    • /
    • pp.964-970
    • /
    • 1996
  • One hundred eight patients (Feb.'86, through Jan.'96) underwent 53 mitral(MVR), 20 aortic(AVR), )5 double(DVR) valve replacement with SJM prosthesis. There were 55 males and 53 females whose mean age was 36.3 $\pm$ 10.4 years. We used 143 valves in mitral(88), aortic(54), and tricuspid(1) sites. The size and number of valves were 31 mm(32). 33inm(23), 29mm(20), 27mm(10), 25mm(2), and 35mm(1) in mitral site; 2)mm(21), 21mm(1 S), 19mm(7), 25mm(5), 27mm(2), and 33mm(1) in aortic site; and Blmm(1) in tricuspid site. Preoperative NYHA functional classes were II(14), III(73) and IV(21), and which were improved into I(89) and II(16) postoperatively. Early postoperative complications occurred in 15 cases(13.9%) in which LOS was the most common one(5 cases; 4.6%). fatly hospital death occurred in 3 cases(2.8%) due to LOS(1) and sudden cardiac arrest(2) he cummulative total follow-up period was 437.6 pl-yr with a mean of 4.1$\pm$2.9 years. There were 5 events of valve related'complications (2 TE, 1 paravalvular leak, 1 TE+paravalvular leak, 1 PVE) with the occurrence rate as 1.14%/pt-yr. Reoperation was performed in 2 cases and there were 2 cases of valve related death due to one PVE and one paravalvlllar leak. The complication free rate was 91.4$\pm$ ).4% at 10 years. Actuarial survival rate was 93.6 $\pm$ 3.1 % at 10 years.

  • PDF

Early Outcomes of Sutureless Aortic Valves

  • Hanedan, Muhammet Onur;Mataraci, Ilker;Yuruk, Mehmet Ali;Ozer, Tanil;Sayar, Ufuk;Arslan, Ali Kemal;Ziyrek, Ugur;Yucel, Murat
    • Journal of Chest Surgery
    • /
    • v.49 no.3
    • /
    • pp.165-170
    • /
    • 2016
  • Background: In elderly high-risk surgical patients, sutureless aortic valve replacement (AVR) should be an alternative to standard AVR. The potential advantages of sutureless aortic prostheses include reducing cross-clamping and cardiopulmonary bypass (CPB) time and facilitating minimally invasive surgery and complex cardiac interventions, while maintaining satisfactory hemodynamic outcomes and low rates of paravalvular leakage. The current study reports our single-center experience regarding the early outcomes of sutureless aortic valve implantation. Methods: Between October 2012 and June 2015, 65 patients scheduled for surgical valve replacement with symptomatic aortic valve disease and New York Heart Association function of class II or higher were included to this study. Perceval S (Sorin Biomedica Cardio Srl, Sallugia, Italy) and Edwards Intuity (Edwards Lifesciences, Irvine, CA, USA) valves were used. Results: The mean age of the patients was $71.15{\pm}8.60years$. Forty-four patients (67.7%) were female. The average preoperative left ventricular ejection fraction was $56.9{\pm}9.93$. The CPB time was $96.51{\pm}41.27minutes$ and the cross-clamping time was $60.85{\pm}27.08minutes$. The intubation time was $8.95{\pm}4.19hours$, and the intensive care unit and hospital stays were $2.89{\pm}1.42days$ and $7.86{\pm}1.42days$, respectively. The mean quantity of drainage from chest tubes was $407.69{\pm}149.28mL$. The hospital mortality rate was 3.1%. A total of five patients (7.69%) died during follow-up. The mean follow-up time was $687.24{\pm}24.76days$. The one-year survival rate was over 90%. Conclusion: In the last few years, several models of valvular sutureless bioprostheses have been developed. The present study evaluating the single-center early outcomes of sutureless aortic valve implantation presents the results of an innovative surgical technique, finding that it resulted in appropriate hemodynamic conditions with acceptable ischemic time.

Surgical Repair of Single Ventricle (Type III C solitus) (단심실 -III C Solitus 형의 수술치험-)

  • naf
    • Journal of Chest Surgery
    • /
    • v.12 no.3
    • /
    • pp.281-288
    • /
    • 1979
  • For years, physicians and anatomists have been interested in the heart that has one functioning ventricle. Various terms have been suggested for this entity including single ventricle, common ventricle, double-inlet left ventricle, cor biatriatum triloculare, and primitive ventricle. In this report, the term "single ventricle" is utilized as suggested by Van Praagh, and is defined as that congenital cardiac anomaly in which a common or separate atrioventricular valves open into a ventricular chamber from which both great arterial trunks emerge. An outlet chamber, or infundibulum, may or may not be present and give rise to the origin of either of the great arteries. This definition excludes the entity of mitral and tricuspid atresia. An 11 year old cyanotic boy was admitted chief complaints of exertional dyspnea and frequent upper respiratory infection since 2 weeks after birth. He was diagnosed as inoperable cyanotic congenital heart disease, and remained without any corrective treatment up to his age of 11 year when he suffered from aggravation of symptoms and signs of congestive heart failure for 2 months before this admission. On 22nd of May 1979, he was admitted for total corrective operation under the impression of tricuspid atresia suggested by a pediatrician. Physical check revealed deep cyanosis with finger and toe clubbing, and grade V systolic ejection murmur with single second heart sound was audible at the left 3rd intercostal space. Development was moderate in height [135 cm] and weight[28Kg]. Routine lab findings were normal except increased hemoglobin [21.1gm%], hematocrit [64 %], and left axis deviation with left ventricular hypertrophy on EKG. Cardiac catheterization and angiography revealed 1-transposition of aorta, pulmonic valvular stenosis, double inlet of a single ventricle with d-loop, and normal atriovisceral relationship [Type III C solitus according to the classification of Van Praagh]. At operation, longitudinal incision at the outflow tract of right ventricle in between the right coronary artery and its branch [LAD from RCA] revealed high far anterior aortic valve which had fibrous continuity with mitral annulus, and pulmonic valve was stenotic up to 4 mm in diameter positioned posterolaterally to the aorta. Ventricular septum was totally defective, and one markedly hypertrophied moderator band originated from crista supraventricularis was connected down to the imaginary septum of the ventricular cavity as a pseudoseptum of the ventricle. Size of the defect was 3X3 cm2 in total. Patch closure of the defect with a Teflon felt of 3.5 x 4 cm2 was done with interrupted multiple sutures after cut off of the moderator band, which was resutured to the artificial septum after reconstruction of the ventricular septum. Pulmonic valvotomy was done from 4 mm to 11 mm in diameter thru another pulmonary arteriotomy incision, and right ventriculotomy wound was closed reconstructing the right ventricular outflow tract with pericardial autograft of 3 x 4 cm2. Atrial septal defect of 2 cm in diameter was closed with 3-0 Erdeck suture, and atrial wall was sutured also when rectal temperature reached from 24`C to 35.5`C. Complete A-V block was managed with temporary external pacemaker with a pacing rate of 110/min. thru myocardial wire, and arterial blood pressure of 80/50 mmHg was maintained with Isuprel or Dopamine dripping under the CVP of 25-cm saline. Consciousness was recovered one hour after the operation when his blood pressure reached 100 /70 mmHg, but vital signs were not stable, and bleeding from the pericardial drainage and complete anuria were persisted until his heart could not capture the pacemaker impulse, and patient died of low output syndrome 320 min after the operation.

  • PDF