• Title/Summary/Keyword: Heart sound

Search Result 146, Processing Time 0.027 seconds

Design of Lung Sound Analyzer Using Adaptive Digital Filter and DSP Chip (적응 디지탈 필터와 DSP 칩을 이용한 폐음 분석기 설계)

  • 김규한;조일준
    • Journal of Biomedical Engineering Research
    • /
    • v.10 no.2
    • /
    • pp.151-156
    • /
    • 1989
  • Lung sound analyer which can provide an objective diagnosis of patients with pulmonary and bronchial disorders is designed. For the purpose of power spectrum analysis, adaptive digital filtering technique and TM - S320C25 DSP chip is used. As a results, adaptive lattice Wiener filter could eliminate heart sounds with a few of 10th order and on the distribution of power spectrum each patterns has shown in normal vescicular breathy from 100 Hz to 200 Hz, in crackle sound from 100 Hz to 400 Hz, in wheeze sound from 150 Hz to 600 Hz.

  • PDF

Animal Diagnosis System Using Wireless Digital Stethoscope (무선 디지털청진기를 이용한 동물 진단시스템)

  • Park, Kee-Young;Hong, Soo-Mi;Lee, Jong-Ha;Park, Jin-Ho;Jung, Eui-Bung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38B no.9
    • /
    • pp.722-727
    • /
    • 2013
  • Medical treatment for animals is very difficult as the opinions of pets' masters take priority over treatment regardless of the seriousness of pets' disease or the needs of medical treatment. In case that a pet has heart disease, especially, it is difficult to get the direct answer from the pet's master on the decision or confirmation of treatment. For those reasons, it is almost impossible to predict and treat the pet before an emergency like the heart failure or an unexpected death happens. Using stethoscope can be the first diagnosis method to check the heart or any kinds of disease inside the body. High-tech equipments like CT, X-ray or Ultrasound can be used, but they can only be used as a second choice of diagnosis method since it requires professional skills and its high price. That's why stethoscope is still the best diagnostic tool when one makes the first diagnosis. In this study, we give a detailed account of digital diagnosis system in which veterinarians can analyze the sound from stethoscope without bringing it to their ears and make a diagnosis wherever they are. And we suggest a new concept of diagnosis system surrounding, which shows the relativeness of disease through Level Crossing Rate(LCR) and energy level from the stethoscope sound made in this system.

Automatic Detection Algorithm for Snoring and Heart beat Using a Single Piezoelectric Sensor (압전센서를 이용한 코골이와 심박 검출을 위한 자동 알고리즘)

  • Urtnasan, Erdenebayar;Park, Jong-Uk;Jeong, Pil-Soo;Lee, Kyoung-Joung
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.143-149
    • /
    • 2015
  • In this paper, we proposed a novel method for automatic detection for snoring and heart beat using a single piezoelectric sensor. For this study multi-rate signal processing technique was applied to detect snoring and heart beat from the single source signal. The sound event duration and intensity features were used to snore detection and heart beat was found by autocorrelation. The performance of the proposed method was evaluated on clinical database, which is the nocturnal piezoelectric snoring data of 30 patients that suffered obstructive sleep apnea. The method achieved sensitivity of 88.6%, specificity of 96.1% with accuracy of 95.6% for snoring and sensitivity of 94.1% and positive predictive value of 87.6% for heart beat, respectively. These results suggest that the proposed method can be a useful tool in sleep monitoring and sleep disordered breathing diagnosis.

A Study of the influence of stimulus on newborn infant생s response -Specifically in heart rate change- (감각적 자극에 따른 신생아 반응에 관한 연구 -심박동수를 중심으로-)

  • 이자형;하영수
    • Journal of Korean Academy of Nursing
    • /
    • v.13 no.3
    • /
    • pp.119-126
    • /
    • 1983
  • Early extra-uterine development of the newborn infant has the potential for clarifying important questions of nature and care taking environment. In this study, tactile and auditory stimulation is used on .a group of infants to determine the effects of their response. Infants were tested by EKG at 24∼48 hrs after birth ana all they are free from complication. Stimuli presented were-touch and sound (40dB, 70dB and 40∼70dB). The result of the study were as follows: 1) The heart rate was seen to depend on their sleep-wake state. (light sleep ; 125/min, eyes: open & motor activity increase ; 151/min crying ; 185/min). 2) The heart rate affected by tactile & auditory stimulus. The heart rate response was acceleration above the prestimulus level. (tactile, 231min increase, auditory ; 16∼21/min increase), and heart rate change was seen to depend on prestimulus rate. (γ=.73) 3) There was a decrease in heart rate when they were soothe. (touch ; 24.8sec, 21/min decrease, pacifier ; 14.5sec, 26/min decrease) and significant difference in time between touch and pacifier (t= 1.76, p<0.05). This result support the evaluation of newborn infant's sensory abilitics, and has even begin to influence changes in nursing care. But systemic monitoring of newborn infants response would. further define.

  • PDF

Electronic Stethoscope using PVDF Sensor for Wireless Transmission of Heart and Lung Sounds (PVDF를 이용한 청진 센서 및 심폐음 무선 전송이 가능한 전자 청진기)

  • Im, Jae Joong;Lim, Young Chul
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.6
    • /
    • pp.57-63
    • /
    • 2012
  • Effective use of stethoscope is very important for primary clinical diagnosis for the increasing cardiovascular and respiratory disease. This study developed the contact vibration sensor using piezopolymer film which minimizes the ambient noise, and signal processing algorithm was applied for providing better auscultation sounds compare to the existing electronic stethoscopes. Especially, low frequency heart sounds were acquired without distortion, and the quality of lung sounds were improved. Also, auscultating sounds could be transmitted using bluetooth, which made possible to be used for the u-healthcare environment. Results of this study, auscultation of heart and lung sounds, could be applied to the convergence industry of medical and information communication technology through remote diagnosis.

A Study on the Tele-medicine Robot System with Face to Face Interaction

  • Shin, Dae Seob
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.293-301
    • /
    • 2020
  • Consultation with the patient and doctor is very important in the examination. However, if the consultation cannot be done directly, such as corona virus, it is difficult for the doctor to determine the patient's condition more accurately. Recently, an image counseling system has been developed based on the Internet, but in the case of heart disease, remote medical counseling cannot be performed because it is not possible to stethoscope the heart sounds remotely. In order to solve this problem, it is necessary to develop an interactive mobile robot capable of remote medical consultation, and a doctor and a patient should be able to set a planting sound during consultation and transmit it in real time. In this paper, we developed a robot that can remotely control a medical counseling robot to move to a hospital room where patients are hospitalized, and to consult a patient in the room remotely from a doctor's office. A remote medical imaging stethoscope system for real-time heart sound transmission is presented. The proposed system is a kind of P2P communication that transmits video information, audio information, and control signal independently through webRTC platform, so that there is no data loss. Consults and sees doctors in real time and finds it more effective than traditional methods for patient security. The system implemented in this paper will be able to perform remote medical care in the place where the spread of diseases between humans like the recent corona 19 as well as the remote medical care of heart disease patients in the future.

EVALUATION OF CLINICAL METHODS IN THE DIAGNOSIS OF TEMPOROMANDIBULAR JOINT DISORDERS: A COMPARISON STUDY WITH MAGNETIC RESONANCE IMAGING (측두하악관절 장애에 대한 임상진단의 유효성 연구)

  • Kim, Hyung-Wook;Shin, Sung-Soo;Kim, Jong-Sik;Kim, Ki-Young;Kim, Yoon-Ji;Hong, Soon-Min;Cheon, Se-Hwan;Park, Yang-Ho;Choi, Won-Cheul;Park, Jun-Woo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.4
    • /
    • pp.367-374
    • /
    • 2007
  • Purpose: The diagnostic relevancies and characteristics and of clinical methods in the diagnosis of internal derangement(ID) were tested by comparing the results of them with those of magnetic resonance imaging(MRI). Methods: 75 patients(150 temporomandibular joints; TMJs), who were suspected to have ID by clinical diagnoses, were included. Clinical diagnoses including mouth opening pathway and TMJ sound were conducted and MRI takings were done. Accuracies, sensitivities, specificities, positive predictive values, and negative predictive values of clinical diagnosis, mouth opening pathway, and TMJ sound were calculated by comparing with diagnoses with MRIs. Results: Accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of clinical diagnosis were 59.3%, 83%, 49%, 81%, and 51%. They were 59%, 82%, 25%, 73%, and 35% for mouth opening pathways. Although deviation was somewhat accurate for representing disc displacement with reduction(ADDWR), other discrepancies on opening pathways were not clinically relevant. Accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of clicking sounds were 85%, 49%, 78%, 85%, and 37%. TMJs with crepitus were only three. But all TMJs with crepitus were diagnosed to have disc displacement without reduction(ADDWOR). Conclusion: When compared with diagnoses with MRIs, clinical diagnoses for ID were not so accurate. But they were suitable for screening tests for ID. Opening pathways and TMJ sounds were not so relevant in the diagnoses of IDs and so it was concluded that considerations for other factors must be included in the diagnoses of IDs.

Measurements of Acoustic Properties of Tofu and Acorn Curd as Potential Tissue-mimicking Materials

  • Li Ying;Guntur S.R.Anjaneya Reddy;Choi Min Joo;Paeng Dong-Guk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.4E
    • /
    • pp.132-138
    • /
    • 2005
  • The purpose of this study is to measure the acoustic properties of Tofu and Acorn Curd (Dotori Muk), which are possibly used as tissue mimicking materials (TMMs). Due to its availability and low cost, Tofu was suggested as a TMM by several researchers who measured only sound speed and attenuation. The acoustic properties of Tofu and Muk including the backscattering coefficient were measured in this paper. Sound speed was measured by the time shift in a pulse echo setup. Attenuation coefficients and backscattering coefficients were measured by a broadband method using both 5 MHz and 10 MHz transducers in the frequency domain. The measured acoustic properties of both Tofu and Muk are observed to be similar to those of biological tissues such as beef liver or beef heart.

Response analysis of 5 vitals relation to meridian by Stimulus of sound wave based on 5 tones. (5음기준 음파자극에 따른 5장관련 경락의 반응분석)

  • 김용진;정동명;이봉구;손인철
    • Proceedings of the IEEK Conference
    • /
    • 2000.06e
    • /
    • pp.99-102
    • /
    • 2000
  • This study analyze of reflection wave to Acoustic stimulation on acupoints and contrast parts for objectification of the meridian substance. In order to verify meridian pathway and channel theory of bio-energy in body. It was analyzed response characteristic of reflection waves after acoustic stimulation by sound wave of 5 specific tones. The response characteristics of reflection are measured by the average current magnitude of meridian. The current variation ratio are Live Meridian(gung) 33.2%, Heart Meridian(sang) 30.7%, Kidney Meridian (gak) 33.1%, Spleen Meridian(chi) 33.9%, Lung Meridian (wo) 30.7% compare with contrast parts (non-acupoint and meridian). Therefore meridian is distinguished to non-meridian and 5 vital meridians have relationship with sound wave of 5 specific tones.

  • PDF