• Title/Summary/Keyword: Heart development

Search Result 1,071, Processing Time 0.034 seconds

A study on the development of motor-driven artificial heart and its control (인공심장의 자동제어)

  • 민병구;김희찬;권성일
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.643-647
    • /
    • 1986
  • A new type of motor-driven Total Artificial Heart (TAH) system with rolling-ball mechanism has been developed. To test its performance as a Left Ventricular Assist Device (LVAD), LVAD is controlled to bypass blood for impaired heart triggered by the R-wave in ECG. Results of the test with a Mock Circulation System (MCS) and an animal experiment with a dog are also included. More powerful system using a brushless DC motor has been developed and its control scheme is represented.

  • PDF

The Lived Experience of Patients with Heart Transplantation: A Phenomenological Study (심장이식환자의 체험: 현상학적 연구)

  • Hwang, Younghui;Yi, Myungsun
    • Journal of Korean Academy of Nursing
    • /
    • v.47 no.1
    • /
    • pp.110-120
    • /
    • 2017
  • Purpose: The purpose of this study was to describe the lived experience of patients with heart transplantation in Korea. Methods: Individual indepth interviews and a focus group interview were used to collect the data from nine patients who had heart transplantations in 2015. All interviews were audio-taped and verbatim transcripts were made for the analysis. Data were analyzed using Colaizzi's phenomenological method. Results: Among the nine participants, eight were men. Mean age was 57.30 years. Six theme clusters emerged from the analysis. 'Joy of rebirth obtained by good luck' describes the pleasure and expectation of new life after narrow survival. 'Suffering from adverse drug effects' illustrates various psychosocial difficulties, such as low self-esteem, helplessness, alienation, and burnout, arising from the side effects of medications. 'Body and mind of being bewildered' illustrates disintegrated health and haunting fear of death. 'Alienation disconnected with society' describes isolated feeling of existence due to misunderstandings from society. 'Suffering overcome with gratitude and responsibility' includes overcoming experience through various social supports and suitable jobs. Finally, 'acceptance of suffering accompanied with new heart' illustrate changed perspective of life itself. Conclusion: The findings in this study provide deep understanding and insights of the lived experience of heart related illness for these patients and should help in the development of tailored-interventions for patients with heart transplantation.

Investigation into the Distribution of Total, Free, Peptide-bound, Protein-bound, Soluble-and Insoluble-Collagen Hydroxyproline in Various Bovine Tissues

  • Siddiqi, Nikhat J.;Alhomida, Abdullah S.
    • BMB Reports
    • /
    • v.36 no.2
    • /
    • pp.154-158
    • /
    • 2003
  • Collagen is a family of proteins which consists of several genetically distinct molecular species and is intimately involved in tissue organization, function, differentiation and development. The purpose of this study was to investigate the concentration of different hydroxyproline (Hyp) fractions viz., total, free, peptide-bound, protein-bound, soluble- and insoluble-collagen hydroxyproline (Hyp) in various bovine tissues. Results showed that liver had the highest concentration of free Hyp followed by kidney, brain, spleen, lungs, muscle and heart. Liver also had the highest concentration of peptide-bound collagen Hyp followed by kidney, heart, spleen, lungs, brain and muscle. The concentration of protein-bound collagen Hyp was highest in the liver, followed by kidney, spleen, lungs, muscle, brain and heart. Total Hyp was highest in the liver, followed by kidney, spleen, brain, heart, muscle and lungs. Liver also had significantly high concentration of collagen as compared to other tissues examined (P<0.001). Spleen had the significantly higher concentration of soluble-collagen Hyp when compared to other tissues (P<0.001). This was followed by heart, muscle, lungs, brain, kidney and liver. Heart had the highest concentration of insoluble-collagen Hyp followed by lungs, kidney, liver, muscle, spleen and brain. The variation among the insoluble-collagen Hyp concentration of heart and muscle, spleen and brain was significant (P<0.001). We speculate that these differences could be due to the variation in turn over of rate of collagen metabolism in this species.

Accuracy Verification of Heart Rate and Energy Consumption Tracking Devices to Develop Forest-Based Customized Health Care Service Programs

  • Choi, Jong-Hwan;Kim, Hyeon-Ju
    • Journal of People, Plants, and Environment
    • /
    • v.22 no.2
    • /
    • pp.219-229
    • /
    • 2019
  • This study was carried out to verify the accuracy of fitness tracking devices in monitoring heart rate and energy consumption and to contribute to the development of a forest exercise program that can recommend the intensity and amount of forest exercises based on personal health-related data and provide monitoring and feedback on forest exercises. Among several commercially available wearable devices, Fitbit was selected for the research, as it provides Open API and data collected by Fitbit can be utilized by third parties to develop programs. Fitbit provides users with various information collected during forest exercises including exercise time and distance, heart rate, energy consumption, as well as the altitude and slope of forests collected by GPS. However, in order to verify the usability of the heart rate and energy consumption data collected by Fitbit in forest, the accuracy of heart rate and energy consumption were verified by comparing the data collected by Fitbit and reference. In this study, 13 middle-aged women were participated, and it was found that the heart rate measured by Fitbit showed a very low error rate and high correlation with that measured by the reference. The energy consumption measured by Fitbit was not significantly different from that measured in the reference, but the error rate was slightly higher. However, there was high correlation between the results measured by Fibit and the reference, therefore, it can be concluded that Fitbit can be utilized in developing actual forest exercise programs.

Development and Animal Tests of Artificial Heart Valves (인공심장판막의 개발 및 동물실)

  • 이재영
    • Journal of Chest Surgery
    • /
    • v.20 no.3
    • /
    • pp.458-472
    • /
    • 1987
  • A heart supplies bloods of about 15, 000 liters to each human organ in a day. A normal function of heart valves is necessary to this act of heart. The disease of heart valve develops to a narrowness of a closure, resulting in an abnormal circulation of bloods. In an attempt to eliminate the affliction of heart valves, the operation method to repair with artificial heart valves has been developed and saved numerous patients over past 30 years. This replacement operation has been performed since early 1960`s in Korea, but all the artificial heart valves used are imported from abroad with very high costs until recent years. The artificial heart valve using pyrolytic carbon has been developed at KAIST, which was proved to be stable in the mechanical performance and durability. Therefore, the in viva performance of this valve was examined through animal tests. The artificial heart valves used in this study are tilting disc type valves, in which the disc were made of graphite coated with pyrolytic carbon and the cages were made of titanium. In viva testings of these valves were performed in 12 dogs, in which right ventriculo-pulmonary arterial [Croup I] or inter-aortic [Croup IV] valved conduit was implanted using polytetrafluoroethylene conduits containing KAIST valve and aortic valve [Group II] or pulmonary valve [Croup III] was replaced by a KAIST valve with a 21mm or 19mm tissue annulus diameter. In group I and II, pre-and post-operative transvalvular pressure gradient was measured and compared with other prosthetic valves. During post operative period laboratory examination was performed including hemoglobin, hematocrit, red cell count, white cell, lactic acid dehydrogenase and platelet. The eight surviving dogs were sacrificed and autopsy was performed at 2, 6, and 8 weeks. KAIST valve has low transvalvular gradient and relatively high orifice area. Average ventriculo-aortic peak systolic transvalvular gradient was 14 mmHg in 21 mm valve and 19 mmHg in 19 mm valve. The valve has slight intravascular hemolysis effect. Thrombogenic effect of low polishing quality and eddy currents around small orifice is high. The valve has vulnerability of disc movement. These animal tests suggest that the improvement of the heart valve design, surface polishing state and prescription methods.

  • PDF

Study on Establishment of criteria for Heart Disease in Oriental Medicine (심병증 진단요건의 표준 설정을 위한 연구)

  • Choi Sun Mi;Park Kyung Mo;Jeung Chan Gil;Sung Hyun Jea;Ahn Kyoo Seok
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.17 no.4
    • /
    • pp.845-851
    • /
    • 2003
  • The objective is to establish the standard of criteria for differential diagnosis of signs and symptoms. This study selected signs and symptoms related to heart which stands for Fire(火) as a kind of five phase(五行). Eleven experts was asked to evaluate the adequateness of criteria which was developed by Korea Institute of Oriental Medicine(KIOM) and to suggest the amendment of them. To implement the study, we used the questionnaire which asks about the diagnosis criteria for an insufficiency of the heart-qi(心氣虛證), deficiency of the heart blood(心血氣證), deficiency of the heart-yin(心陰虛證), insufficiency of the heart-yang(心陽虛證), exuberant fire due to hyperactivity of the heart(心火亢盛證), stagnation of the heart blood(心血瘀阻證), heart disturbed by phlegm-fire(痰火擾心證), attack of the heart by retainedfluid(水氣凌心證). Every criteria consists of primary symptoms, secondary symptoms, tongue findings. and pulse findings. In perspectives of the classification of patterns for signs and symptoms and criteria for diagnosis, the result shows that the previous standard doesn't have so many problem. So many of experts were agree with the criteria which was suggested but the trend is that they use, in their actual practice, less than the criteria. Additionally, they pointed that every element in a criterion should have the different weight value, criteria for the overlapped pattern should be added, and, in future, criteria which are based on clinical investigation should be established.

Development of transcutaneous energy transmission system for implantable total artificial heart (인공심장용 무선에너지 전송 시스템의 개발)

  • 이우철;안재목;이상훈;민병구
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1991.10a
    • /
    • pp.762-767
    • /
    • 1991
  • To make electromechanical total artificial heart implantable inside the body, transcutaneous energy transmission system was designed and simulated by using PSPICE program. The fabricated system was evaluated by using Mock circulation system and showed comparable performance with the D.C power supply

  • PDF

Heart Sound Recognition using Principal Components Analysis (주성분 분석 기법을 이용한 심음 인식)

  • Lee, Sang-Min;Hong, Seung-Hong
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.38 no.5
    • /
    • pp.59-69
    • /
    • 2001
  • Recently many researches concerning heart sound analysis are being processed with development of digital signal processing and electronic components. But there are few researches about recognition of heart sound, especially full cardiac cycled heart sound, In this paper, a new recognition methods about. full cardiac cycled heart sound was proposed. For the first, the database was built by principal components analysis on training heart sound set. This database is used to recognize new input of heart sound, Ilear sounds were classified into seven classes such as normal(NO) class, pre-systolic murmurr(PS) class, early systolic murmur(ES) class, late systolic murmurr(LS) class, early diastolic murmur(EI) class, late diastolic murmur(LD) class and continuous murmuru(CM) class. As a result, we could verify that our new method has better efficiencies for the recognition the characteristics of heart sound than any precedent research. The maximum recognition rates of the new method are 71% for NO, 80% for PS and ES, 78% for LS, 87% for ED, 60% for LD and 20% for CM. Although the present results aren't practically sufficient to use our new method in recognizing heart sound, the importance of this paper is for recognition of heart sound within full cardiac cycle. We can get a better result by building a more efficient database.

  • PDF