• Title/Summary/Keyword: Heart Sound Segmentation

Search Result 5, Processing Time 0.018 seconds

Performance Comparison Between the Envelope Peak Detection Method and the HMM Based Method for Heart Sound Segmentation

  • Jang, Hyun-Baek;Chung, Young-Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.2E
    • /
    • pp.72-78
    • /
    • 2009
  • Heart sound segmentation into its components, S1, systole, S2 and diastole is the first step of analysis and the most important part in the automatic diagnosis of heart sounds. Conventionally, the Shannon energy envelope peak detection method has been popularly used due to its superior performance in locating S1 and S2. Recently, the HMM has been shown to be quite suitable in modeling the heart sound signal and its use in segmenting the heart sound signal has been suggested with some success. In this paper, we compared the two methods for heart sound segmentation using a common database. Experimental tests carried out on the 4 different types of heart sound signals showed that the segmentation accuracy relative to the manual segmentation was 97.4% in the HMM based method which was larger than 91.5% in the peak detection method.

Automatic Classification of Continuous Heart Sound Signals Using the Statistical Modeling Approach (통계적 모델링 기법을 이용한 연속심음신호의 자동분류에 관한 연구)

  • Kim, Hee-Keun;Chung, Yong-Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.4
    • /
    • pp.144-152
    • /
    • 2007
  • Conventional research works on the classification of the heart sound signal have been done mainly with the artificial neural networks. But the analysis results on the statistical characteristic of the heart sound signal have shown that the HMM is suitable for modeling the heart sound signal. In this paper, we model the various heart sound signals representing different heart diseases with the HMM and find that the classification rate is much affected by the clustering of the heart sound signal. Also, the heart sound signal acquired in real environments is a continuous signal without any specified starting and ending points of time. Hence, for the classification based on the HMM, the continuous cyclic heart sound signal needs to be manually segmented to obtain isolated cycles of the signal. As the manual segmentation will incur the errors in the segmentation and will not be adequate for real time processing, we propose a variant of the ergodic HMM which does not need segmentation procedures. Simulation results show that the proposed method successfully classifies continuous heart sounds with high accuracy.

Performance Improvement of Cardiac Disorder Classification Based on Automatic Segmentation and Extreme Learning Machine (자동 분할과 ELM을 이용한 심장질환 분류 성능 개선)

  • Kwak, Chul;Kwon, Oh-Wook
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.1
    • /
    • pp.32-43
    • /
    • 2009
  • In this paper, we improve the performance of cardiac disorder classification by continuous heart sound signals using automatic segmentation and extreme learning machine (ELM). The accuracy of the conventional cardiac disorder classification systems degrades because murmurs and click sounds contained in the abnormal heart sound signals cause incorrect or missing starting points of the first (S1) and the second heart pulses (S2) in the automatic segmentation stage, In order to reduce the performance degradation due to segmentation errors, we find the positions of the S1 and S2 pulses, modify them using the time difference of S1 or S2, and extract a single period of heart sound signals. We then obtain a feature vector consisting of the mel-scaled filter bank energy coefficients and the envelope of uniform-sized sub-segments from the single-period heart sound signals. To classify the heart disorders, we use ELM with a single hidden layer. In cardiac disorder classification experiments with 9 cardiac disorder categories, the proposed method shows the classification accuracy of 81.6% and achieves the highest classification accuracy among ELM, multi-layer perceptron (MLP), support vector machine (SVM), and hidden Markov model (HMM).

Detection of Main Components of Heart Sound Using Third Moment Characteristics of PCG Envelope (심음 포락선의 3차 모멘트를 이용한 심음의 주성분 검출)

  • Quan, Xing-Ri;Bae, Keun-Sung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.12
    • /
    • pp.3001-3008
    • /
    • 2013
  • To diagnose the cardiac valve abnormalities using analysis of phonocardiogram, first of all, accurate detection of S1, S2 components is needed for heart sound segmentation. In this paper, a new method that uses the third moment characteristics of an envelope of the PCG is proposed for accurate detection of S1 and S2 components of the heart sound with cardiac murmurs. The envelope of the PCG is obtained from the short-time energy profile, and its third moment profile with slope information is used for accurate time gating of the S1, S2 components. Experimental results have shown that the proposed method is superior to the conventional second moment method for detection of S1 and S2 regions from the heart sound signals with cardiac murmurs.

Heart Sound-Based Cardiac Disorder Classifiers Using an SVM to Combine HMM and Murmur Scores (SVM을 이용하여 HMM과 심잡음 점수를 결합한 심음 기반 심장질환 분류기)

  • Kwak, Chul;Kwon, Oh-Wook
    • The Journal of the Acoustical Society of Korea
    • /
    • v.30 no.3
    • /
    • pp.149-157
    • /
    • 2011
  • In this paper, we propose a new cardiac disorder classification method using an support vector machine (SVM) to combine hidden Markov model (HMM) and murmur existence information. Using cepstral features and the HMM Viterbi algorithm, we segment input heart sound signals into HMM states for each cardiac disorder model and compute log-likelihood (score) for every state in the model. To exploit the temporal position characteristics of murmur signals, we divide the input signals into two subbands and compute murmur probability of every subband of each frame, and obtain the murmur score for each state by using the state segmentation information obtained from the Viterbi algorithm. With an input vector containing the HMM state scores and the murmur scores for all cardiac disorder models, SVM finally decides the cardiac disorder category. In cardiac disorder classification experimental results, the proposed method shows the relatively improvement rate of 20.4 % compared to the HMM-based classifier with the conventional cepstral features.