• Title/Summary/Keyword: Heart Rate

Search Result 3,335, Processing Time 0.034 seconds

Methods for Recording and Counting the Heart Rate of Intact Animal and Isolated Preparations (실험동물(實驗動物)의 심박계측법(心搏計測法))

  • Chang, Hwang-Nam
    • The Korean Journal of Pharmacology
    • /
    • v.4 no.1 s.5
    • /
    • pp.37-39
    • /
    • 1968
  • A method for presenting the heart rate of intact animals as a kymographic record is described. A transistorized impulse generator with a dry battery power supply is used to produce pulses. The pulses are integrated and make a pen motor drived. The ability of the instrument to follow a wide range of heart rate change is demonstrated. The instrument is especially usefull to observe an acute and transitory heart rate change. A method for changing the heart beat to sound and a method for counting the heart rate of intact animal and isolated preparations by employing post office counter were also described.

  • PDF

A Practical Protocol of Zebrafish Heart Rate Measurement for High School Students

  • Cho, Jeong Hoon
    • Journal of Integrative Natural Science
    • /
    • v.14 no.4
    • /
    • pp.155-158
    • /
    • 2021
  • To study the effects of hormones and neurotransmitters, zebrafish (Danio rerio) are a great substitute for water fleas (Daphnia). The zebrafish is an ideal vertebrate model because it has a transparent embryonic stage. It is easy to get consistent heart rate measurements in embryonic zebrafish when treating them with hormones and neurotransmitters. To observe the heart rate, two to three embryonic zebrafish are anesthetized with MS-222 and then transferred to a glass slide specifically designed for heart observation and easy application of various chemicals. After the heartbeats are counted for 2 minutes, apply either 100 µM epinephrine or 100 µM acetylcholine to the zebrafish. Wait 5, 10, and 20 minutes and count the heartbeats at each time point. All procedures are repeated three times. The final results are averaged and analyzed by using statistical methods. The above method which we have developed is practical enough for high school students to measure the heart rate in zebrafish under various conditions and to analyze the data set.

An emergency care system for heart attack using heart rate monitoring (심박측정을 이용한 Mobile Life Keeper 시스템 구현)

  • Kim, Woojong;Lee, Suhoon;Tariq, Muhammad;Lee, Gang-Hwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.326-330
    • /
    • 2012
  • In 2011, There were about 25,000 people died because of heart disease. The aim of this paper is to design a heart attack situation monitoring and spreading system for patients. Wearable computer with a sensor is used to monitor heart rate. Heart rate is transffered to smartphone with bluetooth. After analyzing heart rate, smartphone spread out the emergency situation by various service including emergency call, SNS and SMS.

  • PDF

Effects of Cardiovascularly Acting Neuroendocrine Agents on Heart Beatings of Pacific Oyster, Crassostrea gigas (순환기 기능 조절기능을 가진 신경내분비계 작용물질이 참굴의 심장 수축기능에 미치는 영향)

  • Park, Kwan-Ha
    • The Korean Journal of Malacology
    • /
    • v.25 no.1
    • /
    • pp.15-22
    • /
    • 2009
  • Because it is known that bivalve hearts contain various modulatory systems activated by neuroendocrine substances, it was examined whether different classes of endogenous and synthetic drugs of neuroendocrinological importance can influence cardiac functions of the Pacific oyster Crassostrea gigas. Cholinergically active agents acetylcholine and carbachol increased heart rates while diminishing cardiac contractility. Adrenergically active substances norepinephrine (NE) and epinephrine (Epi) also induced heart rate increase and contractility decrease. An $\alpha_1$-adrenergic receptor-selective agonist phenyephrine (PE) failed to modulate either parameter. The Epi-induced heart rate increase and contractile depression were both blocked significantly by non-selective $\beta_1/\beta_2$-adrenergic antagonist propranolol. A $\beta_1$-selective antagonist atenolol prevented Epi-induced heart rate decrease but not the contractile depression, suggesting possible $\beta_2$ receptors for Epi-induced contractile depression. The three autacoids examined exerted discrete responses: histamine increased heart rate and depressed contraction; $\gamma$-amino-butyric acid increased both parameters; serotonin failed to change either parameter. The 5 piscine anesthetic agents examined, MS-222, benzocaine, quinaldine, urethane, pantocaine and pentobarbital, all failed to influence the cardiac function of oysters. Collectively, activities of neuroendocrinologically acting agents in mammals showed unexpected and distinct activities from those in mammalian cardiovascular systems. These results obtained from substances of different physiological functions can serve as a basis for understanding neuroendocrine control of the heart function in Pacific oyster.

  • PDF

Comparison between Heart Rates and Borg's Scale as a Tool to Evaluate Physical Workload (작업 현장에서 육체적 작업 강도를 평가하는 도구로서 Borg's Scale과 심박 수의 비교)

  • Kim, Byoung Hoon;Park, Ji Young;Tak, Sangwoo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.29 no.3
    • /
    • pp.368-374
    • /
    • 2019
  • Objectives: To examine the associations of borg's scale with actual heart rates of workers and energy consumption during their physical work. Methods: A total of 72 workers performing physical activities in postal service, ceramic manufacturing, and metal manufacturing participated in heart rate measurement for 1 work shift using the activity meter(A360) and responded to a borg's scale questionnaire. Results: In consistent with previous findings, we presented high correlation between borg's scale and energy consumption measures among workers performing physical activities(r=0.89) while post-work average heart rate showed nearly no correlation with post-work borg's scale (r=0.09). We proposed a set of adjustments when using borg's scale to estimate physical workload for those workers engaged in physical activities during the majority of their work shift. Conclusions: Our findings suggest that a caution should be paid to when using Borg's scale to estimate heart rates during physical activities as well as energy consumption as the product of heart rate measurements.

Heart Rate Change of Carp Cyprinus Carpio During Swimming Activity (유영운동에 의한 잉어의 심박수변화)

  • 안영일
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.31 no.1
    • /
    • pp.24-28
    • /
    • 1995
  • Exercise physiology of fish was studied by means of Electro-cardio-gram(ECG) technique with wired electrode system. Effects of swimming activity on the heart rate change for carp Cyprinus carpio was observed and analysed under swimming speeds among 1~3 Body Length/s and swimming durations of 10 and 60 minutes in the flume tank. The heart rate increase during swimming activity was observed in higher speed and longer duration conditions. The exercise effect on the heart rate continued even after fish stopped swimming. The time for recovery after exercise was tended to be elongated with the higher exercise condition.

  • PDF

Analysis of Heart Rate Variability Signals in Time-Domain and Frequency-Domain (Heart Rate Variability 신호의 시간 및 주파수 영역 분석)

  • Kil, Jung-Su;Kwon, Ho-Yeol
    • Journal of Industrial Technology
    • /
    • v.22 no.B
    • /
    • pp.163-167
    • /
    • 2002
  • Autonomic nervous system play an important role of keeping our health as balancing homeostasis. But the abnormality of these abilities makes our presence be feeble. To obtain these information of body which helps for us to decide whether one is healthy or not, based on the study of Heart Rate Variability. In this paper, we presented HRV model and its processing steps to extract some information of human body. After that, some experimental results are presented in time-domain and frequency-domain.

  • PDF

Heart Rate Measurement Combining Motion and Color Information

  • Lomaliza, Jean-Pierre;Park, Hanhoon;Moon, Kwang-Seok
    • Journal of Korea Multimedia Society
    • /
    • v.23 no.11
    • /
    • pp.1388-1395
    • /
    • 2020
  • Daily monitoring of the heart rate can facilitate detection of heart-related diseases in their early stages. Therefore, providing an easy-to-use and noninvasive heart rate monitoring system has been a very popular research topic in the field of healthcare. One of good candidate methods is to use commonly available cameras and extract information that can help to estimate heart rate from a human face. Generally, such information can be retrieved using two different approaches: photoplethysmography (PPG) and ballistocardiography (BCG). PPG exploits slight color changes caused by blood volume variations during heartbeats; thus, it tends to be vulnerable to unstable lighting conditions. BCG exploits subtle head motions caused by pumped blood travelling through the carotid artery during heartbeats; thus, it is vulnerable to the voluntary head movements that are not related to heartbeats. Nevertheless, most related works use either to estimate the heart rate. In this paper, we propose to combine two approaches to be robust to challenging conditions. Specifically, we explore possible ways to combine raw signals obtained from two approaches and verify that the proposed combination shows better accuracies under challenging conditions, such as voluntary head movements and ambient lighting changes.

Development of a Modular Clothing System for User-Centered Heart Rate Monitoring based on NFC (NFC 기반 사용자 중심의 모듈형 심박측정 의류 시스템 개발)

  • Cho, Hakyung;Cho, SangWoo;Cho, Kwang Nyun
    • Science of Emotion and Sensibility
    • /
    • v.23 no.2
    • /
    • pp.51-60
    • /
    • 2020
  • This study aimed to develop a modular smart clothing system for heart rate monitoring that reduces the inconvenience caused by battery charging and the large size of measurement devices. The heart rate monitoring system was modularized into a temporary device and a continuous device to enable heart rate monitoring depending on the requirement. The temporary device with near-field communication (NFC) and heart rate sensors was developed as a clothing attachment type that enables heart rate monitoring via smart phone tagging when required. The continuous device is based on Bluetooth Low Energy (BLE) communication and batteries and was developed to enable continuous heart rate measurement via a direct connection to the temporary device. Furthermore, the temporary device was configured to connect with a textile electrode made of a silver-based knitted fabric designed to be located below the pectoralis major muscle for heart rate measurement. Considering the user-experience factors, key functions, and the ease of use, we developed an application to automatically log through smart phone tagging to improve usability. To evaluate the accuracy of the heart rate measurement, we recorded the heart rate of 10 healthy male subjects with a modular smart clothing system and compared the results with the heart rate values measured by the Polar RS800. Consequently, the average heart rate value measured by the temporary system was 85.37, while that measured by the reference device was 87.03, corresponding to an accuracy of 96.73%. No significant difference was found in comparison with the reference device (T value = -1.892, p = .091). Similarly, the average heart rate measured by the continuous system was 86.00, while that measured by the reference device was 86.97, corresponding to an accuracy of 97.16%. No significant difference was found in terms of the heart rate value between the two signals (T value = 1.089, p = .304). The significance of this study is to develop and validate a modular clothing system that can measure heart rates according to the purpose of the user. The developed modular smart clothing system for heart rate monitoring enables dual product planning by reducing the price increase due to unnecessary functions.

A Study of the influence of stimulus on newborn infant생s response -Specifically in heart rate change- (감각적 자극에 따른 신생아 반응에 관한 연구 -심박동수를 중심으로-)

  • 이자형;하영수
    • Journal of Korean Academy of Nursing
    • /
    • v.13 no.3
    • /
    • pp.119-126
    • /
    • 1983
  • Early extra-uterine development of the newborn infant has the potential for clarifying important questions of nature and care taking environment. In this study, tactile and auditory stimulation is used on .a group of infants to determine the effects of their response. Infants were tested by EKG at 24∼48 hrs after birth ana all they are free from complication. Stimuli presented were-touch and sound (40dB, 70dB and 40∼70dB). The result of the study were as follows: 1) The heart rate was seen to depend on their sleep-wake state. (light sleep ; 125/min, eyes: open & motor activity increase ; 151/min crying ; 185/min). 2) The heart rate affected by tactile & auditory stimulus. The heart rate response was acceleration above the prestimulus level. (tactile, 231min increase, auditory ; 16∼21/min increase), and heart rate change was seen to depend on prestimulus rate. (γ=.73) 3) There was a decrease in heart rate when they were soothe. (touch ; 24.8sec, 21/min decrease, pacifier ; 14.5sec, 26/min decrease) and significant difference in time between touch and pacifier (t= 1.76, p<0.05). This result support the evaluation of newborn infant's sensory abilitics, and has even begin to influence changes in nursing care. But systemic monitoring of newborn infants response would. further define.

  • PDF