• Title/Summary/Keyword: Heart PET

Search Result 49, Processing Time 0.03 seconds

In a Universal Design Viewpoint Usability Evaluation Research to PET Bottle (유니버설 디자인 관점에서의 PET BOTTLE에 대한 사용성 평가 연구 -어린이 음료용기를 중심으로-)

  • Kim Sang-Sik
    • The Journal of the Korea Contents Association
    • /
    • v.5 no.5
    • /
    • pp.124-132
    • /
    • 2005
  • While use of a pet bottle with use it is light recently and convenient increases quickly, it is used from the child, also diffusing the user to a pet bottle to people of various classes, such as an old person, a woman, a male, the man in the street, and a disabled person. However, those who are standardized on the basis of the common man with the plan energy of a pet bottle, and cannot attain to the standard, That is, a child and a disabled person may be condemnedto the vague situation that a lid cannot be opened or a contents thing cannot be drunk without external help. And the characteristic of a material and production which are called PET Even if convenience is emphasized for the cost reduction of COST, a design is chosen easily, and even if it calls it the man in the street, the point of coming to experience a situation with the difficult time of use can be found well. In research of a book, problem derivation which classifies entering school and a preschool boy and girl child for a child drink for an object first by the viewpoint of universal design paying attention to such problems, and leads the actual use example of a pet bottle was carried out in true heart, and various notional approach was shown by the solution method.

  • PDF

Animal Diagnosis System Using Wireless Digital Stethoscope (무선 디지털청진기를 이용한 동물 진단시스템)

  • Park, Kee-Young;Hong, Soo-Mi;Lee, Jong-Ha;Park, Jin-Ho;Jung, Eui-Bung
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.38B no.9
    • /
    • pp.722-727
    • /
    • 2013
  • Medical treatment for animals is very difficult as the opinions of pets' masters take priority over treatment regardless of the seriousness of pets' disease or the needs of medical treatment. In case that a pet has heart disease, especially, it is difficult to get the direct answer from the pet's master on the decision or confirmation of treatment. For those reasons, it is almost impossible to predict and treat the pet before an emergency like the heart failure or an unexpected death happens. Using stethoscope can be the first diagnosis method to check the heart or any kinds of disease inside the body. High-tech equipments like CT, X-ray or Ultrasound can be used, but they can only be used as a second choice of diagnosis method since it requires professional skills and its high price. That's why stethoscope is still the best diagnostic tool when one makes the first diagnosis. In this study, we give a detailed account of digital diagnosis system in which veterinarians can analyze the sound from stethoscope without bringing it to their ears and make a diagnosis wherever they are. And we suggest a new concept of diagnosis system surrounding, which shows the relativeness of disease through Level Crossing Rate(LCR) and energy level from the stethoscope sound made in this system.

Feasibility of Shrinking Field Radiation Therapy through 18F-FDG PET/CT after 40 Gy for Stage III Non-Small Cell Lung Cancers

  • Ding, Xiu-Ping;Zhang, Jian;Li, Bao-Sheng;Li, Hong-Sheng;Wang, Zhong-Tang;Yi, Yan;Sun, Hong-Fu;Wang, Dong-Qing
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.1
    • /
    • pp.319-323
    • /
    • 2012
  • Objective: To explore the feasibility of shrinking field technique after 40 Gy radiation through 18F-FDG PET/CT during treatment for patients with stage III non-small cell lung cancer (NSCLC). Methods: In 66 consecutive patients with local-advanced NSCLC, 18F-FDG PET/CT scanning was performed prior to treatment and repeated after 40 Gy. Conventionally fractionated IMRT or CRT plans to a median total dose of 66Gy (range, 60-78Gy) were generated. The target volumes were delineated in composite images of CT and PET. Plan 1 was designed for 40 Gy to the initial planning target volume (PTV) with a subsequent 20-28 Gy-boost to the shrunken PTV. Plan 2 was delivering the same dose to the initial PTV without shrinking field. Accumulated doses of normal tissues were calculated using deformable image registration during the treatment course. Results: The median GTV and PTV reduction were 35% and 30% after 40 Gy treatment. Target volume reduction was correlated with chemotherapy and sex. In plan 2, delivering the same dose to the initial PTV could have only been achieved in 10 (15.2%) patients. Significant differences (p<0.05) were observed regarding doses to the lung, spinal cord, esophagus and heart. Conclusions: Radiotherapy adaptive to tumor shrinkage determined by repeated 18F-FDG PET/CT after 40 Gy during treatment course might be feasible to spare more normal tissues, and has the potential to allow dose escalation and increased local control.

Current Status and Future Perspective of PET (PET 이용 현황 및 전망)

  • Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.1
    • /
    • pp.1-7
    • /
    • 2002
  • Positron Emission Tomography (PET) is a nuclear medicine imaging modality that consists of systemic administration to a subject of a radiopharmaceutical labeled with a positron-emitting radionuclide. Following administration, its distribution in the organ or structure under study can be assessed as a function of time and space by (1) defecting the annihilation radiation resulting from the interaction of the positrons with matter, and (2) reconstructing the distribution of the radioactivity from a series of that used in computed tomography (CT). The nuclides most generally exhibit chemical properties that render them particularly desirable in physiological studies. The radionuclides most widely used in PET are F-18, C-11, O-15 and N-13. Regarding to the number of the current PET Centers worldwide (based on ICP data), more than 300 PET Centers were in operation in 2000. The use of PET technology grew rapidly compared to that in 1992 and 1996, particularly in the USA, which demonstrates a three-fold rise in PET installations. In 2001, 194 PET Centers were operating in the USA. In 1994, two clinical and research-oriented PET Centers at Seoul National University Hospital and Samsung Medical Center, was established as the first dedicated PET and Cyclotron machines in Korea, followed by two more PET facilities at the Korea Cancer Center Hospital, Ajou Medical Center, Yonsei University Medical Center, National Cancer Center and established their PET Center. Catholic Medical School and Pusan National University Hospital have finalized a plan to install PET machine in 2002, which results in total of nine PET Centers in Korea. Considering annual trends of PET application in four major PET centers in Korea in Asan Medical Center recent six years (from 1995 to 2000), a total of 11,564 patients have been studied every year and the number of PET studies has shown steep growth year upon year. We had 1,020 PET patients in 1995. This number increased to 1,196, 1,756, 2,379, 3,015 and 4,414 in 1996,1997,1998,1999 and 2000, respectively. The application in cardiac disorders is minimal, and among various neuropsychiatric diseases, patients with epilepsy or dementia can benefit from PET studios. Recently, we investigated brain mapping and neuroreceptor works. PET is not a key application for evaluation of the cardiac patients in Korea because of the relatively low incidence of cardiac disease and less costly procedures such as SPECT can now be performed. The changes in the application of PET studios indicate that, initially, brain PET occupied almost 60% in 1995, followed by a gradual decrease in brain application. However, overall PET use in the diagnosis and management of patients with cancer was up to 63% in 2000. The current medicare coverage policy in the USA is very important because reimbursement policy is critical for the promotion of PET. In May 1995, the Health Care Financing Administration (HCFA) began covering the PET perfusion study using Rubidium-82, evaluation of a solitary pulmonary nodule and pathologically proven non-small cell lung cancer. As of July 1999, Medicare's coverage policy expanded to include additional indications: evaluation of recurrent colorectal cancer with a rising CEA level, staging of lymphoma and detection of recurrent or metastatic melanoma. In December of 2001, National Coverage decided to expand Medicare reimbursement for broad use in 6 cancers: lung, colorecctal, lymphoma, melanoma, head and neck, and esophageal cancers; for determining revascularization in heart diseases; and for identifying epilepsy patients. In addition, PET coverage is expected to further expand to diseases affecting women, such as breast, ovarian, uterine and vaginal cancers as well as diseases like prostate cancer and Alzheimer's disease.

Diagnosis of Primary Malignant Lesion Using $^{18}F$ FDG PET/CT in Metastatic Bone Tumor (전이성 골종양에서 $^{18}F$ FDG PET/CT를 이용한 원발성 악성 질환의 진단)

  • Yoon, Hoi-Soo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.14 no.1
    • /
    • pp.44-50
    • /
    • 2008
  • Purpose: To evaluate usefulness in diagnosing primary malignant lesion of metastatic bone tumor using $^{18}F$ FDG PET/CT. Material & Methods: Retrospective analysis was executed on 5,452 patients who were taken with $^{18}F$ FDG PET/CT between December 2003 and December 2007. 180 patients who had not any history of malignancy and complained musculoskeletal pain and had ill-defined osteolytic lesion in plain X-ray, were included. 96 male and 84 female were enrolled and mean age was 59.1 year old (22~90). We analyzed diagnostic accuracy, age and sex distribution of primary malignant lesion, location of metastatic lesion. Results: We could confirmed primary malignant lesion in 152 cases (84.4%). Most common malignant primary lesion was lung (28.3%), breast (18.9%) and gastrointestinal system (16.7%) and spine was the most common metastatic location of primary malignant lesion. Conclusion: $^{18}F$ FDG PET/CT is a effective molecular imaging detecting primary malignant lesion in patients having metastatic bone lesion without history of malignancy.

  • PDF

Clinical Significance of Myocardial Uptake on F-18 FDG PET/CT Performed in Oncologic Patients (종양 환자의 F-18 FDG PET/CT에서 관찰된 심근 섭취의 임상적 의미)

  • Cho, Ho-Jin;Cho, Arthur;Lee, Jong-Doo;Kang, Won-Jun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.6
    • /
    • pp.519-525
    • /
    • 2009
  • Purpose: F-18 fluorodeoxyglucose (FDG) uptake of myocardium is influenced by various factors. Increased glycolysis, and subsequent increased F-18 FDG uptake has been reported in ischemic cardiomyopathy. However, clinical significance of incidentally found myocardial F-18 FDG uptake has not been clarified. We retrospectively reviewed the degree and pattern of myocardial uptake in patients without history of ischemic heart disease who underwent torso F-18 FDG PET/CT for evaluation of neoplastic disease. Materials and Methods: From January 2005 to June 2009, 77 patients who underwent F-18 FDG PET/CT and Tc-99m sestamibi stress/rest SPECT within 3 months were enrolled. Results: Of 77 patients, 55 (71.4%) showed increased F-18 FDG uptake in the myocardium. In this population, 40 showed uniform uptake pattern, while 15 showed focal uptake. In patients with uniform uptake, 17 showed decreased uptake in the septum without perfusion defect on myocardial SPECT. Remaining 23 patients showed uniform uptake, with 1 reversible perfusion defect and 1 fixed perfusion defect. In 15 patients with focal uptake, 9 showed increased F-18 FDG uptake in the base, and only 1 of them showed reversible perfusion defect on myocardial SPECT. In the remaining 6 focal uptake group, 4 had reversible perfusion defect in the corresponding wall, and 1 had apical hypertrophy. Conclusion: We demonstrated that septal defect pattern and basal uptake pattern in the myocardium may represent normal variants. Focal myocardial uptake other than normal variants on oncologic torso F-18 FDG PET/CT with routine fasting protocol may suggest ischemic heart disease, thus further evaluation is warranted.

Comparison of F-18 FDG Radioacitivity to Determine Accurate Dose Calibrator Activity Measurements (방사능 측정기를 이용한 F-18 FDG 방사능의 비교)

  • Jin, Gye-Hwan;Kweon, Dae-Cheol;Oh, Ki-Baek;Park, Hoon-Hee;Kim, Jung-Yul;Park, Min-Soo;Park, Dae-Sung
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.159-166
    • /
    • 2009
  • Obviously, the administration of the prescribed amount of activity to the patient requires proper operation of the dose calibrator, which shall be verified by implementing the required quality control on the instrument. This investigation examined the accuracy and precision of dose calibrator activity measurement of the radiopharmaceutical F-18 FDG. To investigate the status of the nuclear medicine centers in Korea for the performance of dose calibrators, 10 centers providing PET/CT system services in Korea were inspected in 2008. We measured accuracy and precision in 10 equipments in consideration of PET/CT model, installation area, and installation time. According to the results of comparative analysis of 10 dose calibrators used to measure radioactivity of F-18 FDG, accuracy was -5.00~4.50% and precision was 0.05~0.45%, satisfying the international standards, which are accuracy ${\pm}$10% and precision ${\pm}$5%. This study demonstrated that, for accurate measurements, no adjustment is necessary for a dose calibrator setting when measuring different dose calibrators of F-18 FDG activity prescriptions.

  • PDF

Mycobacterium avium Complex Infection-Related Immune Reconstitution Inflammatory Syndrome Mimicking Lymphoma in an Human Immunodeficiency Virus-Infected Patient

  • Sohn, Sungmin;Shi, Hye Jin;Wang, Sung Ho;Lee, Sang Ki;Park, So Yeon;Lee, Jin Seo;Eom, Joong Sik
    • Infection and chemotherapy
    • /
    • v.50 no.4
    • /
    • pp.350-356
    • /
    • 2018
  • In acquired immunodeficiency syndrome (AIDS) patients, immune reconstitution inflammatory syndrome (IRIS) due to Mycobacterium avium complex (MAC) infection is one of the most difficult IRIS types to manage. We report an unusual case of MAC-associated IRIS. At first the patient was diagnosed human immunodeficiency virus (HIV) infection after he was admitted with pneumocystis pneumonia. After starting antiretroviral therapy he presented unmasked IRIS with MAC infection. Next, he was hospitalized with continuous loose stools and new-onset fever. Investigation included computed tomography (CT), which showed homogeneous enhancement and enlargement of the lymph nodes (LN), elevation of ferritin (>1,650 ng/mL) and lactate dehydrogenase (306 IU/L) levels, and F- fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) scan, which showed increased FDG uptake. These findings were highly indicative of lymphoma. We performed laparoscopic biopsy of the mesenteric LN, and the biopsy culture grew MAC. So we made a diagnosis of MAC-associated. Therefore, IRIS must be considered as a possible diagnosis when AIDS patients develop new symptoms or exhibit exacerbations of existing symptoms. Furthermore the biopsies should be conducted.

Recent Update of Advanced Imaging for Diagnosis of Cardiac Sarcoidosis: Based on the Findings of Cardiac Magnetic Resonance Imaging and Positron Emission Tomography

  • Chang, Suyon;Lee, Won Woo;Chun, Eun Ju
    • Investigative Magnetic Resonance Imaging
    • /
    • v.23 no.2
    • /
    • pp.100-113
    • /
    • 2019
  • Sarcoidosis is a multisystem disease characterized by noncaseating granulomas. Cardiac involvement is known to have poor prognosis because it can manifest as a serious condition such as the conduction abnormality, heart failure, ventricular arrhythmia, or sudden cardiac death. Although early diagnosis and early treatment is critical to improve patient prognosis, the diagnosis of CS is challenging in most cases. Diagnosis usually relies on endomyocardial biopsy (EMB), but its diagnostic yield is low due to the incidence of patchy myocardial involvement. Guidelines for the diagnosis of CS recommend a combination of clinical, electrocardiographic, and imaging findings from various modalities, if EMB cannot confirm the diagnosis. Especially, the role of advanced imaging such as cardiac magnetic resonance (CMR) imaging and positron emission tomography (PET), has shown to be important not only for the diagnosis, but also for monitoring treatment response and prognostication. CMR can evaluate cardiac function and fibrotic scar with good specificity. Late gadolinium enhancement (LGE) in CMR shows a distinctive enhancement pattern for each disease, which may be useful for differential diagnosis of CS from other similar diseases. Effectively, T1 or T2 mapping techniques can be also used for early recognition of CS. In the meantime, PET can detect and quantify metabolic activity and can be used to monitor treatment response. Recently, the use of a hybrid CMR-PET has introduced to allow identify patients with active CS with excellent co-localization and better diagnostic accuracy than CMR or PET alone. However, CS may show various findings with a wide spectrum, therefore, radiologists should consider the possible differential diagnosis of CS including myocarditis, dilated cardiomyopathy (DCM), hypertrophic cardiomyopathy, amyloidosis, and arrhythmogenic right ventricular cardiomyopathy. Radiologists should recognize the differences in various diseases that show the characteristics of mimicking CS, and try to get an accurate diagnosis of CS.

Radiation dosimetry of 89Zr labeled antibody estimated using the MIRD method and MCNP code

  • Saeideh Izadi Yazdi ;Mahdi Sadeghi ;Elham Saeedzadeh ;Mostafa Jalilifar
    • Nuclear Engineering and Technology
    • /
    • v.55 no.4
    • /
    • pp.1265-1268
    • /
    • 2023
  • One important issue in using radiopharmaceuticals as therapeutic and imaging agents is predicting different organ absorbed dose following their injection. The present study aims at extrapolating dosimetry estimates to a female phantom from the animal data of 89Zr radionuclide accumulation using the Sparks-Idogan relationship. The absorbed dose of 89Zr radionuclide in different organs of the human body was calculated based on its distribution data in mice using both MIRD method and the MCNP simulation code. In this study, breasts, liver, heart wall, stomach, kidneys, lungs and spleen were considered as source and target organs. The highest and the lowest absorbed doses were respectively delivered to the liver (4.00E-02 and 3.43E-02 mGy/MBq) and the stomach (1.83E-03 and 1.66E-03 mGy/MBq). Moreover, there was a good agreement between the results obtained from both MIRD and MCNP methods. Therefore, according to the dosimetry results, [89Zr] DFO-CR011-PET/CT seems to be a suitable for diagnostic imaging of the breast anomalies for CDX-011 targeting gpNMB in patients with TNBC in the future.