• Title/Summary/Keyword: Hearing aids

Search Result 143, Processing Time 0.017 seconds

A Study on the AtoN Operational Software Development for the AtoN Management and the Decision Support of its Placement Planning (항로표지 관리 및 배치 의사결정 지원을 위한 항로표지 운용 소프트웨어 개발에 관한 연구)

  • Kim, Ah-Young;Lee, Yeong-Ju;Park, Se-Kil;Oh, Jae-Yong;Kim, Yeon-Gyu
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.5
    • /
    • pp.543-551
    • /
    • 2014
  • This study has searched to find a program in order to manage simply and practically use the expelled AtoN database from the AtoN Simulator and to support the idea decision for the AtoN placement. It examines a program that manages AtoN database through the hierarchy structure, history card and endowment with condition same as a scenario. And accomplishes this study's goal owing to realizing AtoN operational software that helps for visual, hearing sense, fixed amount verification upon AtoN placement project. The AtoN operational software contributes not only flexible control like a newly establishment, relocation etc, but also supports idea decision for AtoN placement plan through many functions such as condition search, virtual sailing and fixed amount appraisal result exhibition, etc. Through utilization of this, it is to help upon the presupposition of the impact to ship or sailor about many designs and in addition, upon the judgment of whether or not for the efficiency and appropriation of the design. It is expected to reduce possible failure costs and management costs due to AtoN design and placement plans, because to compare more various designs thru the easier verification method.

Development of Bi0.5(Na0.78K0.22)0.5TiO3 Lead-free Piezoelectric Ceramic Material with Core-shell Structure for Biomedical (바이오 메디컬용 코어-쉘 구조의 Bi0.5(Na0.78K0.22)0.5TiO3계 무연압전세라믹 소재의 개발)

  • Seong-jun Yun;Joonsoo Bae
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.46 no.3
    • /
    • pp.15-22
    • /
    • 2023
  • BNKT Ceramics, one of the representative Pb free based piezoelectric ceramics, constitutes a perovskite(ABO3) structure. At this time, the perovskite structure (ABO3) is in the form where the corners of the octahedrons are connected, and in the unit cell, two ions, A and B, are cations, A ion is located at the body center, B ion is located at each corner, and an anion O is located at the center of each side. Since Bi, Na, and K sources constituting the A site are highly volatile at a sintering temperature of 1100℃ or higher, it is difficult to maintain uniformity of the composition. In order to solve this problem, there should be suppression of volatilization of the A site material or additional compensation of the volatilized. In this study, the basic composition of BNKT Ceramics was set to Bi0.5(Na0.78K0.22)0.5TiO3 (= BNKT), and volatile site (Bi, Na, and K sources) were coated in the form of a shell to compensate additionally for the A site ions. In addition, the physical and electrical properties of BNKT and its coated with shell additives(= @BNK) were compared and analyzed, respectively. As a result of analyzing the crystal structure through XRD, both BNKT(Core) and @BNK(Shell) had perovskite phases, and the crystallinity was almost similar. Although the Curie temperature of the two sintered bodies was almost the same (TC = 290 ~ 300 ℃), it was confirmed that the d33 (piezoelectric coefficient) and Pr (residual polarization) values were different. The experimental results indicated that the additional compensation for a shell additive causes the coarsening, resulting in a decrease in sintering density and Pr(remanent polarization). However, coating shell additives to compensate for A site ion is an effective way to suppress volatilization. Based on these experimental results, it would be the biggest advantage to develop an eco-friendly material (Lead-free) that replaced lead (Pb), which is harmful to the human body. This lead-free piezoelectric material can be applied to a biomedical device or products(ex. earphones (hearing aids), heart rate monitors, ultrasonic vibrators, etc.) and skin beauty improvement products (mask packs for whitening and wrinkle improvement).

A Study on Fall Accident (1개 종합병원 환자의 낙상에 관한 조사)

  • Lee, Hyeon-Suk;Kim, Mae-Ja
    • The Korean Nurse
    • /
    • v.36 no.5
    • /
    • pp.45-62
    • /
    • 1998
  • The study was conducted from November 1995 to May 1996 at the one general hospital in Seoul. The total subjects of this study were 412 patients who have the experience of fall accident, among them 31 was who have fallen during hospitalization and 381 was who visited emergency room and out patient clinic. The purposes of this study were to determine the characteristics, risk factors and results of fall accident and to suggest the nursing strategies for prevention of fall. Data were collected by reviewing the medical records and interviewing with the fallers and their family members. For data analysis, spss/pc+ program was utilized for descriptive statistics, adjusted standardized $X^2$-test. The results of this study were as follows: 1) Total subjects were 412 fallers, of which 245(59.5%) were men and 167(40.5%) were women. Age were 0-14 years 79(19.2%), 15-44 years 125(30.4%), 45-64 years 104(25.2%), over 65 years 104(25.2%). 2) There was significant association between age and the sexes ($X^2$=39.17, P=0.00). 3) There was significant association between age and history of falls ($X^2$=44.41. P= .00). And history of falls in the elderly was significantly associated with falls. 4) There was significant association with age and medical diagnosis ($X^2$=140.66, P= .00), chief medical diagnosis were hypertension(34), diabetis mellitus(22), arthritis(11), stroke(8), fracture(7), pulmonary tuberculosis(6), dementia(5) and cataract(5), 5) There was significant association between age and intrinsic factors: cognitive impairment, mobility impairment, insomnia, emotional problems, urinary difficulty, visual impairments, hearing impairments, use of drugs (sedatives , antihypertensive drugs, diuretics, antidepressants) (P < 0.05). But there was no significant association between age and dizziness ($X^2$=2.87, P=.41). 6) 15.3% of total fallers were drunken state when they were fallen. 7) Environmental factors of fall accident were unusual posture (50.9%), slips(35.2%), trips (9.5%) and collision(4.4%). 8) Most of falls occurred during the day time, peak frequencies of falls occurred from 1pm to 6pm and 7am to 12am. 9) The places of fall accident were roads(22.6%), house-stairs 06.7%), rooms, floors, kitchen (11.2%), the roof-top, veranda, windows(10.9%), hospital(7.5%), ice or snowy ways(5.8%), bathroom(4.9%), playground, park(4.9%), subway-stairs(4.4%) and public-bathrooms (2.2%). 10) Activities at the time of fall accident were walking(37.6%), turning around or reaching for something(20.9%), going up or down stairs09.2%), exereise, working07.4%), up or down from a bed(2.7%), using wheelchair or walking aids, standing up or down from a chair(2.2%) and standing still(2.2%). 11) Anatomical locations of injuries by falls were head, face, neck(31.3%), lower extremities (29.9%). upper extremities(20.6%), spine, thorax, abdomen or pelvic contents(l1.4%) and unspecified(2.9%). 12) Types of injures were fracture(47.6%), bruises03.8%), laceration (13.3%), sprains(9.0%), headache(6.6%), abrasions(2.9%), intracranial hemorrage(2.4%) and burns(0.5%). 13) 41.5% of the fallers were hospitalized and average of hospitalization was 22.3 days. 14) The six fallers(1.46%) died from fall injuries. The two fallers died from intracranial hemorrage and the four fallers died of secondary infection; pneumonia(2), sepsis(1) and cell lulitis(1). It is suggested that 1) Further study is needed with larger sample size to identify the fall risk factors. 2) After the fall accident, comprehensive nursing care and regular physical exercise should be emphasized for the elderly person. 3) Safety education and safety facilities of the public place and home is necessary for fall prevention.

  • PDF