• Title/Summary/Keyword: Hearing Level

Search Result 342, Processing Time 0.023 seconds

Translation, Adaptation and Cross-Cultural Validation of Hearing Handicap Inventory for Adult in Malay Language

  • Zam, Tengku Zulaila Hasma binti Tengku Zam;Dzulkarnain, Ahmad Aidil Arafat;Rahmat, Sarah;Jusoh, Masnira
    • Journal of Audiology & Otology
    • /
    • v.23 no.3
    • /
    • pp.129-134
    • /
    • 2019
  • Background and Objectives: Sine a self-reported questionnaire for hearing-impaired listeners is not available by Malay language yet, it is important to develop or translate any available existing questionnaires. The aim of this study was to translate, adapt and validate the Hearing Handicap Inventory for Adult (HHIA) to be used by the audiologist among the hearing-impaired population in Malaysia. Subjects and Methods: The HHIAs was translated to Malay language using forward-backward translation techniques by four-panellists (two for each level). The translated HHIA was then reconciled and harmonized for cultural aspects and content of the questionnaire by the researchers and two expert panels before being pilot-tested among 10 hearing-impaired patients. Questionnaire validation was conducted among 80 adults with a hearing loss to calculate for Cronbach's α (internal reliability), Spearman's correlation (inter-item correlation) and factor analysis. Results: None of the translated items were removed from the scale. The overall Cronbach's α was 0.964; 0.927 and 0.934 for both social and emotional subscales, respectively. The factor analysis (force-concept inventory) demonstrated a two-structure with a strong correlation between all items in either component 1 or 2, that resembled the original scale. The Mann-Whitney test revealed significantly higher scores for those adults with a hearing loss than those adults with normal hearing. Conclusions: The Malay HHIA has been successfully translated and validated for the purpose of determining the psychosocial aspects of adults with hearing loss in the local population.

Translation, Adaptation and Cross-Cultural Validation of Hearing Handicap Inventory for Adult in Malay Language

  • Zam, Tengku Zulaila Hasma binti Tengku Zam;Dzulkarnain, Ahmad Aidil Arafat;Rahmat, Sarah;Jusoh, Masnira
    • Korean Journal of Audiology
    • /
    • v.23 no.3
    • /
    • pp.129-134
    • /
    • 2019
  • Background and Objectives: Sine a self-reported questionnaire for hearing-impaired listeners is not available by Malay language yet, it is important to develop or translate any available existing questionnaires. The aim of this study was to translate, adapt and validate the Hearing Handicap Inventory for Adult (HHIA) to be used by the audiologist among the hearing-impaired population in Malaysia. Subjects and Methods: The HHIAs was translated to Malay language using forward-backward translation techniques by four-panellists (two for each level). The translated HHIA was then reconciled and harmonized for cultural aspects and content of the questionnaire by the researchers and two expert panels before being pilot-tested among 10 hearing-impaired patients. Questionnaire validation was conducted among 80 adults with a hearing loss to calculate for Cronbach's α (internal reliability), Spearman's correlation (inter-item correlation) and factor analysis. Results: None of the translated items were removed from the scale. The overall Cronbach's α was 0.964; 0.927 and 0.934 for both social and emotional subscales, respectively. The factor analysis (force-concept inventory) demonstrated a two-structure with a strong correlation between all items in either component 1 or 2, that resembled the original scale. The Mann-Whitney test revealed significantly higher scores for those adults with a hearing loss than those adults with normal hearing. Conclusions: The Malay HHIA has been successfully translated and validated for the purpose of determining the psychosocial aspects of adults with hearing loss in the local population.

Effects of Residual Hearing on the Auditory Steady State Response for Cochlear Implantation in Children

  • Kim, Young Seok;Han, Sun A;Woo, Hyunjun;Suh, Myung-Whan;Lee, Jun Ho;Oh, Seung Ha;Park, Moo Kyun
    • Journal of Audiology & Otology
    • /
    • v.23 no.3
    • /
    • pp.153-159
    • /
    • 2019
  • Background and Objectives: We aim to explore the effects of residual auditory steady state response (ASSR) on cochlear implantation (CI) outcomes in children lacking auditory brainstem responses (ABRs). Subjects and Methods: We retrospectively reviewed the data of child CI recipients lacking ABRs. All ears were divided into two groups: with residual ASSR and without ASSR. For each frequency, the T- and C-levels and the electrical dynamic ranges of postoperative 3-month and 1-year mappings were compared between the groups. To evaluate speech perception, patients who received simultaneous bilateral CIs were divided into two groups: group 1 exhibited responses at all frequencies in both ears; in group 2, at least one ear evidenced no response. The Categories of Auditory Perception (CAP) and Infant-Toddler Meaningful Auditory Integration Scale (IT-MAIS) scores were compared between the groups. Results: We enrolled 16 patients. At 2 kHz, the postoperative 3-month and 1-year T-levels of patients with residual hearing were lower than those of hearing loss group (p=0.001, p=0.035). In residual hearing group, the ASSR threshold correlated positively with the postoperative 1-year T-level (p=0.012, R2=0.276) and C-level (p=0.002, R2=0.374). Of 10 simultaneous bilateral CI recipients, 5 exhibited ASSRs at all frequencies and the other 5 showed no response at ≥1 frequency. The latter had higher CAP scores at the postoperative 1-year (p=0.018). Conclusions: In children exhibiting hearing loss in ABR testing, residual hearing at 2 kHz ASSR correlated positively with the post-CI T-level. Those with ASSRs at all frequencies had significantly lower CAP scores at the postoperative 1year. CI should not be delayed when marginal residual hearing is evident in ASSR.

Effects of Residual Hearing on the Auditory Steady State Response for Cochlear Implantation in Children

  • Kim, Young Seok;Han, Sun A;Woo, Hyunjun;Suh, Myung-Whan;Lee, Jun Ho;Oh, Seung Ha;Park, Moo Kyun
    • Korean Journal of Audiology
    • /
    • v.23 no.3
    • /
    • pp.153-159
    • /
    • 2019
  • Background and Objectives: We aim to explore the effects of residual auditory steady state response (ASSR) on cochlear implantation (CI) outcomes in children lacking auditory brainstem responses (ABRs). Subjects and Methods: We retrospectively reviewed the data of child CI recipients lacking ABRs. All ears were divided into two groups: with residual ASSR and without ASSR. For each frequency, the T- and C-levels and the electrical dynamic ranges of postoperative 3-month and 1-year mappings were compared between the groups. To evaluate speech perception, patients who received simultaneous bilateral CIs were divided into two groups: group 1 exhibited responses at all frequencies in both ears; in group 2, at least one ear evidenced no response. The Categories of Auditory Perception (CAP) and Infant-Toddler Meaningful Auditory Integration Scale (IT-MAIS) scores were compared between the groups. Results: We enrolled 16 patients. At 2 kHz, the postoperative 3-month and 1-year T-levels of patients with residual hearing were lower than those of hearing loss group (p=0.001, p=0.035). In residual hearing group, the ASSR threshold correlated positively with the postoperative 1-year T-level (p=0.012, R2=0.276) and C-level (p=0.002, R2=0.374). Of 10 simultaneous bilateral CI recipients, 5 exhibited ASSRs at all frequencies and the other 5 showed no response at ≥1 frequency. The latter had higher CAP scores at the postoperative 1-year (p=0.018). Conclusions: In children exhibiting hearing loss in ABR testing, residual hearing at 2 kHz ASSR correlated positively with the post-CI T-level. Those with ASSRs at all frequencies had significantly lower CAP scores at the postoperative 1year. CI should not be delayed when marginal residual hearing is evident in ASSR.

Ototoxic Evaluation of Cis-platinum (Cis-Platinum의 이중독증에 관한 임상적 고찰)

  • 홍원표;정명현;오혜경;이경재
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1982.05a
    • /
    • pp.17.1-17
    • /
    • 1982
  • In 1965, Rosenberg reported that platinum compounds not only inhibit growth and cell division of E. coli but also has anti-tumor activity. Since then, through animal and clinical experiments by Welsch(1971), Speer(1972), Rossof(1972), Hill(1974), and Wittes(1975), it was proved that Cis-platinum has excellent supressive effects on malignant tumor, especially on head and neck cancer. Accordingly, Cis-platinum is now widely used, sometimes without any other durg, or sometimes with Bleomycin and Methotrexate etc. Inspite of the strong anticancer effect, the use of Cis-platinum is quite often discouraged because of the reports that Cis-platinum causes auditory impairment at high frequencies above the speech range due to inner ear damage and irreversible change in the renal tubules. Since Kohonen et al(1965), Standnicki et al(1974) reported that Cisplatinum has toxic effects at the basal turn of the cochlea using guinea pig, many studies on ototoxicity after infusion of Cis-platinum have been carried out using animals. But the studies on ototoxicity in human beings can hardly be found except in reports by Piel et al(1974) and Hong et al (1979). So the authors did a study which tried to clarify the ototoxic effect by comparing the hearing level after infusion of Cis-plastinum with the hearing level before infusion of Cis-plastinum in 30 patients who was treated with Cis-platinum and admitted to the dept. of otolaryngology of Yonsei University Hospital during 2 years and a half from July. 1979 to March. 1982 and the following results were obtained. 1) The results of auditory evaluation, using the pure tone average, hearing loss of 4kHz and 8kHz, Speech Reception Threshold, PB score, SISI showed that the difference of dosage does not change the hearing level after infusion of Cis-platinum and before infusion of Cis-platinum. 2) Cis-platinum had no effect on the hearing level of patients with conductive hearing loss, or with sensorineural hearing loss, as well as with normal hearing level. 3) The infusion of Cis-platinum did not cause any change in creatinine clearance, creatinine, uric acid, but only one case showed that Cis-platinum caused severe nephrotoxicity. 4) The infusion of Cis-plastinum did not cause any change in hemoglobin, leukocyte count, platelet count and there was no correlation with the amount of infusion. 5) To see the side effect of hydration practiced with the infusion of Cis-platinum, the electrolytes, particularly the K level in the serum was measured. But the results did not show any change. 6) Judging from the results of this study mentioned above, ototoxicity caused by infusion of Cis-platinum can be prevented by sufficient hydration. Also the results might say that the appropriate method of infusion of Cis-platinum might be effective in the patients with head and neck cancer who had sensorineural hearing loss for whom the infusion of Cis-platinum has been absolutely cotraindicated.

  • PDF

The relationship between noise awareness, hearing ability, and dental hygiene performance in dental hygienists (치과위생사의 치과 내 소음인식도와 청력관련 특성 및 업무와의 관련성)

  • Park, Kyung-Hwa;Kim, Hyo-Jin
    • Journal of Korean society of Dental Hygiene
    • /
    • v.15 no.1
    • /
    • pp.11-17
    • /
    • 2015
  • Objectives: The purpose of the study is to investigate the relationship between noise awareness, hearing ability, and dental hygiene performance in dental hygienists. Methods: The subjects were 234 dental hygienists in Seoul, Gyeonggi-do, and Incheon. The questionnaire consisted of 3 questions of general characteristics of the subjects, 1 question of noise awareness, 3 questions of hearing ability, 5 questions of dental hygiene performance, 1 question of noise reduction necessity, and 2 questions of noise control. Noise awareness, dental hygiene performance, and noise reduction necessity were measured by Likert 5 scale. Cronbach's alpha was 0.825 in dental hygiene performance reliability. Results: There was a significant difference in noise recognition by age(p<0.01) and working career(p<0.05). Those who pumped up the higher TV volume accounted for 31.6% and 3.0% had hearing impairment in the regular health checkup. 3.4% of the respondents complained of hearing loss, ear fluid, and equilibrium problem diagnosed by the doctors. The relationship between the type of workplace environment and task performance showed a significant difference. Those who work in the dental hospitals had high score of 3.43, while those who work in dental clinics had 3.20(p<0.05). The increased level of noise recognition affected the task performance and it is necessary to reduce the noise level. More try must be focused on the noise exposure prevention. Conclusions: In order to reduce the problems due to noise and improve their quality of life, it is necessary to change the noise recognition in the work place.

The Survey for the Maximum Noise Level of Portable Audio Equipments and Its Assessment (휴대용 음향기기 소음실태 및 소음도 평가)

  • Lee, Jaewon;Gu, J.H.;Park, H.G.;Lee, W.S.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.1
    • /
    • pp.3-8
    • /
    • 2013
  • Recently, the impact on hearing induced by using of portable audio equipment have been actively studied. In general, Because they turn the volume up with loud background noise, they may expose to louder noise. In this study, we investigated the maximum noise level of 20 the domestic potable audio equipment and estimated the impact of the hearing induced by portable audio equipment in according to exposure time. As a result, the use of portable audio equipment is assumed to be more three hours when the level of more than 50 % of volume is most likely to affect the hearing.

Development of Ambulatory Speech Audiometric System (휴대용 어음청력검사 시스템 구현)

  • Shin, Seung-Won;Kim, Kyeong-Seop;Lee, Sang-Min;Im, Won-Jin;Lee, Jeong-Whan;Kim, Dong-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.3
    • /
    • pp.645-654
    • /
    • 2009
  • In this study, we present an efficient ambulatory speech audiometric system to detect one's hearing problems at an earlier stage as possible without his or her visit to the audiometric testing facility such in a hospital or a clinic. To estimate a person's hearing threshold level in terms of speech sound response in his or her local environment, a digital assistant(PDA) device is used to generate the speech sound with implementing audiometric Graphic User Interface(GUI) system. Furthermore, a supra-aural earphone is used to measure a subject's hearing threshold level in terms of speech sound by the compensating the transducer's gain by adopting speech sound calibration system.

Remote Patient Monitoring System for Diagnostic Pure-tone Audiometry (순음 청력검사를 위한 원격진단 모니터링 시스템)

  • Lee, Kang-Ho;Kwon, Yeong-Eun;Kwon, Ohwon
    • Journal of Sensor Science and Technology
    • /
    • v.28 no.5
    • /
    • pp.289-293
    • /
    • 2019
  • This paper presents a remote patient monitoring system for diagnostic pure-tone audiometry. A pure-tone audiometer was developed for basic hearing screening; its performance was evaluated according to international standards in terms of linearity, accuracy, and total harmonic distortion. Pure-tone audiometry has a maximum hearing level of 104.9 dB HL that is comparable with other commercial products. The audiometer shows satisfactory linearity with a deviation of ${\pm}0.4dB$, an accuracy of ${\pm}0.025%$, and a total harmonic distortion (THD) of 0.21%. The remote patient monitoring systems include remote control devices based on wide area network (WAN) connections and an audiometer connected in series. Through experimentation, we successfully performed real-time diagnostic communication without delay in transferring audiometric data. This system is expected to supply domestic equipment in the audiometric market and to improve the quality of life of patients in non-clinical environments.

A Study on Acoustic Masking Effect by Frame-Based Formant Enhancement (프레임 기반의 포먼트 강조에 의한 음향 마스킹 현상 발생에 대한 연구)

  • Jeon, Yu-Yong;Kim, Kyu-Sung;Lee, Sang-Min
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.6
    • /
    • pp.529-534
    • /
    • 2009
  • One of the characteristics of the hearing impaired is that their frequency selectivity is poorer than that of the normal hearing. To compensate this, formant enhancement algorithms and spectral contrast enhancement algorithms have been developed. However in some cases, these algorithms fail to improve the frequency selectivity of the hearing impaired. One of the reasons is the acoustic masking among enhanced formants. In this study, we tried to enhance the formants based on the individual masking characteristic of each subject. The masking characteristic used in this study was minimum level difference (MLD) between the first formant to the second formant while acoustic masking was occurred. If the level difference between the two formants in each frame is larger than the MLD, the gain of the first formant was decreased to reduce the acoustic masking that occurred among formants. As a result of the speech discrimination test, using formant enhanced speeches, speech discrimination score (SDS) of the speeches having differently enhanced formants was significantly superior to SDS of the speeches having equally enhanced formants. It means that suppression of the acoustic masking among formants improve frequency selectivity of the hearing impaired.