• Title/Summary/Keyword: Hearing Level

Search Result 342, Processing Time 0.024 seconds

A Study on the Noise Levels of Cargo-Passenger Iron Ships ply South-West Coast Line (서남 연근해 운항 차도철부선의 선내 소음에 관한 연구)

  • Yu Young-Hun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.12 no.3 s.26
    • /
    • pp.193-199
    • /
    • 2006
  • The noise levels on board ship recognized at Europe in the early 1970s and the noise regulations on the ship began to put in a statutory form. After that, in 1982 'International Code on Noise Levels on Board Ships' adopted by IMO and it became a standards to the newly built ship and it remains up to recently. Especially, the ship engine room, which have huge main engine and various kinds of subsidiary machines, is under an extremely loud condition and so the worker who works in it is easy to lose his hearing. Recently, each nation regulates the allowable noise exposure time by law to protect the industrial employee from the occupational hardness of hearing. In our country, the allowable noise exposure time is regulated by the labor. standard law but the international provisions regulated by IMO have been applied in case of the ship engine room. In this paper, the cabin's noise levels of cargo-passenger ships plies south-west coast line were investigated.

  • PDF

Decreased Expression of TRPV4 Channels in HEI-OC1 Cells Induced by High Glucose Is Associated with Hearing Impairment

  • Xing, Ying;Ming, Jie;Liu, Tao;Zhang, Nana;Zha, Dingjun;Lin, Ying
    • Yonsei Medical Journal
    • /
    • v.59 no.9
    • /
    • pp.1131-1137
    • /
    • 2018
  • Purpose: Previous reports have shown that hyperglycemia-induced inhibition of transient receptor potential vanilloid sub type 4 (TRPV4), a transient receptor potential ion channel, affects the severity of hearing impairment (HI). In this study, we explored the role of TRPV4 in HI using HEI-OC1 cells exposed to high glucose (HG). Materials and Methods: HEI-OC1 cells were cultured in a HG environment (25 mM D-glucose) for 48 hours, and qRT-PCR and Western blotting were used to analyze the expression of TRPV4 at the mRNA and protein level. TRPV4 agonist (GSK1016790A) or antagonist (HC-067047) in cultured HEI-OC1 cells was used to obtain abnormal TRPV4 expression. Functional TRPV4 activity was assessed in cultured HEI-OC1 cells using the MTT assay and a cell death detection ELISA. Results: TRPV4 agonists exerted protective effects against HG-induced HI, as evidenced by increased MTT levels and inhibition of apoptosis in HEI-OC1 cells. TRPV4 overexpression significantly increased protein levels of phosphorylated p38 mitogen-activated protein kinase (p-p38 MAPK), while TRPV4 antagonists had the opposite effect. Our results indicated that TRPV4 is a hyperglycemia-related factor that can inhibit cell proliferation and promote cell apoptosis by activating the MAPK signaling pathway in HEI-OC1 cells. Conclusion: Our results show that the overexpression of TRPV4 can attenuate cell death in HEI-OC1 cells exposed to HG.

A Study on the present condition and control of the high level noise at workplace (사업장 고소음 발생실태 및 관리제도 개선방안 연구)

  • Jung, Woo-Hong;Park, In-Sun;Park, Sang-Kyu;Cho, Hae-Kyeong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.778-782
    • /
    • 2007
  • Over 6 thousand workplaces in Korea are exposed to levels of noise which put their hearing of risk. Goverment considered various methods for noise reduction, but high noise breeds much problems still. This research investigates the present state of noise occurance and studied improvement way of administration system.

  • PDF

New site classification system and design response spectra in Korean seismic code

  • Kim, Dong-Soo;Manandhar, Satish;Cho, Hyung-Ik
    • Earthquakes and Structures
    • /
    • v.15 no.1
    • /
    • pp.1-8
    • /
    • 2018
  • A new site classification system and site coefficients based on local site conditions in Korea were developed and implemented as a part of minimum design load requirements for general seismic design. The new site classification system adopted bedrock depth and average shear wave velocity of soil above the bedrock as parameters for site classification. These code provisions were passed through a public hearing process before it was enacted. The public hearing process recommended to modify the naming of site classes and adjust the amplification factors so that the level of short-period amplification is suitable for economical seismic design. In this paper, the new code provisions were assessed using dynamic centrifuge tests and by comparing the design response spectra (DRS) with records from 2016 Gyeongju earthquake, the largest earthquake in history of instrumental seismic observation in Korea. The dynamic centrifuge tests were performed to simulate the representative Korean site conditions, such as shallow depth to bedrock and short-period amplification characteristics, and the results corroborated with the new DRS. The Gyeongju earthquake records also showed good agreement with the DRS. In summary, the new code provisions are reliable for representing the site amplification characteristic of shallow bedrock condition in Korea.

The Relationship Between Speech Intelligibility and Comprehensibility for Children with Cochlear Implants (조음중증도에 따른 인공와우이식 아동들의 말명료도와 이해가능도의 상관연구)

  • Heo, Hyun-Sook;Ha, Seung-Hee
    • Phonetics and Speech Sciences
    • /
    • v.2 no.3
    • /
    • pp.171-178
    • /
    • 2010
  • This study examined the relationship between speech intelligibility and comprehensibility for hearing impaired children with cochlear implants. Speech intelligibility was measured by orthographic transcription method for acoustic signal at the level of words and sentences. Comprehensibility was evaluated by examining listener's ability to answer questions about the contents of a narrative. Speech samples were collected from 12 speakers(age of 6~15 years) with cochlear implants. For each speaker, 4 different listeners(total of 48 listeners) completed 2 tasks: One task involved making orthographic transcriptions and the other task involved answering comprehension questions. The results of the study were as follows: (1) Speech intelligibility and comprehensibility scores tended to be increased by decreasing of severity. (2) Across all speakers, the relationship was significant between speech intelligibility and comprehensibility scores without considering severity. However, within severity groups, there was the significant relationship between comprehensibility and speech intelligibility only for moderate-severe group. These results suggest that speech intelligibility scores measured by orthographic transcription may not accurately reflect how well listener comprehend speech of children with cochlear implants and therefore, measures of both speech intelligibility and listener comprehension should be considered in evaluating speech ability and information-bearing capability in speakers with cochlear implants.

  • PDF

A Study on the Characteristics of Noise occurred when processing Stone Material (석재가공시 발생하는 소음의 특성에 관한 연구)

  • Ju, Duck-Hoon;Kook, Jung-Hun;Kim, Jae-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.231-235
    • /
    • 2007
  • Stone Industry in our country is classified mainly in view of supply of raw materials ingredients, as follows: Stone-Quarrying Industry who develops the natural resources, Stone Processing Industry who processes the quarried raw ore into construction materials and stone-products, Stony Mountain-Aggregate Industry who supplies the elementary raw materials ingredients to construction section, respectively. Among them, while Stone Processing Industry sells its turnover around billion-Won level per annum per a company, most of other job sites are paltry, adopting less than 10 employees, and it is real state that their working environments are also very coarse. The Noise originated from processing-instrument which generates at such Stone Processing Industry is as so repeatedly reiterating Loud Noise that most of the spot workers are forcedly imposing such dangers as the severe unpleasant feeling and hearing impairments. On this viewpoint, this Research is now analyzing on the frequency characteristics with regard to the Noise that generated from various processing-instruments, and then based on this, in order to grasp the influence of the Loud Noise generating when process the stone materials, this study has ever evaluated it with PSIL and NR. It is considered that such data could be used as the valuable material for establishment of a comfortable working environment hereafter.

  • PDF

Performance Test and Evaluations of a MEMS Microphone for the Hearing Impaired

  • Kwak, Jun-Hyuk;Kang, Hanmi;Lee, YoungHwa;Jung, Youngdo;Kim, Jin-Hwan;Hur, Shin
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.5
    • /
    • pp.326-331
    • /
    • 2014
  • In this study, a MEMS microphone that uses $Si_3N_4$ as the vibration membrane was produced for application as an auditory device using a sound visualization technique (sound visualization) for the hearing impaired. Two sheets of 6-inch silicon wafer were each fabricated into a vibration membrane and back plate, after which, wafer bonding was performed. A certain amount of charge was created between the bonded vibration membrane and the back plate electrodes, and a MEMS microphone that functioned through the capacitive method that uses change in such charge was fabricated. In order to evaluate the characteristics of the prepared MEMS microphone, the frequency flatness, frequency response, properties of phase between samples, and directivity according to the direction of sound source were analyzed. The MEMS microphone showed excellent flatness per frequency in the audio frequency (100 Hz-10 kHz) and a high response of at least -42 dB (sound pressure level). Further, a stable differential phase between the samples of within -3 dB was observed between 100 Hz-6 kHz. In particular, excellent omnidirectional properties were demonstrated in the frequency range of 125 Hz-4 kHz.

Study on the Sound Quality Evaluation Method for the Vehicle Diesel Engine Noise (승용차 디젤 엔진 소음에 대한 음질 평가 기법 연구)

  • Kwon, Jo-Seph;Kim, Chan-Mook;Kim, Ki-Chang;Kim, Jin-Taek
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.10
    • /
    • pp.883-889
    • /
    • 2011
  • The brand sound of vehicle diesel engine is recently one of the important advantage strategies in the automotive company. Because various noise components masked under high frequency level can be audible in quieter driving situation. Many researches have been carried out for subjective and objective assessments on vehicle sounds and noises. In particular, the interior sound quality has been one of research fields that can give high quality feature to vehicle products. Vehicle interior noise above 500 Hz is usually controlled by sound package parts. The materials and geometries of sound package parts directly affect on this high frequency noise. This paper describes the sound quality evaluation method for the vehicle diesel engine noise to establish objective criteria for sound quality assessment. Considering the sensitivity of human hearing to impulsive sounds such as diesel noise, the human auditory mechanism was simulated by introducing temporal masking in the time domain. Furthermore, each of the human auditory organs was simulated by computer codes, providing reasonable analytical explanations of typical human hearing responses to diesel noise. This method finally provides the sound quality index of vehicle diesel engine noise that includes high frequency intermittent offensive sounds caused by impacting excitations of combustion and piston slap.

A Review of Contemporary Teleaudiology: Literature Review, Technology, and Considerations for Practicing

  • Kim, Jinsook;Jeon, Seungik;Kim, Dokyun;Shin, Yerim
    • Korean Journal of Audiology
    • /
    • v.25 no.1
    • /
    • pp.1-7
    • /
    • 2021
  • The scope of teleaudiology has been noted with telehealth due to Coronavirus disease (COVID-19) recently. As the notion has been around us for more than 20 years ever since 1999, it is necessary to perceive the knowledge accurately and prepare for the successful implementation of it. Therefore, the literature review including screening and diagnostic audiometry, cochlear implants and hearing aids, and aural rehabilitation, telecommunications technology regarding several fields of teleaudiology, and considerations for practicing were identified. Although overall internet-based audiological services showed benefits in terms of outcome and accessibility, uncertainties of cost-effectiveness, the optimal level of support, and a need for further studies of many aspects for teleaudiology has arisen. In the view of technology, the store-and-forward (asynchronous/hybrid) and a real-time (synchronous) methods were introduced with one applied and nine registered patents recorded from 2004 to 2020 for the invention of teleaudiology in the United States. Also, 10 checklists were suggested for planning teleaudiology practice from prior experience in hosting the teleaudiology program. Conclusively, it is hoped that this review sheds light on recognizing and improving the existing teleaudiology services and helps overcome the challenges faced in the era of pandemic and untact world to come.

A Review of Contemporary Teleaudiology: Literature Review, Technology, and Considerations for Practicing

  • Kim, Jinsook;Jeon, Seungik;Kim, Dokyun;Shin, Yerim
    • Journal of Audiology & Otology
    • /
    • v.25 no.1
    • /
    • pp.1-7
    • /
    • 2021
  • The scope of teleaudiology has been noted with telehealth due to Coronavirus disease (COVID-19) recently. As the notion has been around us for more than 20 years ever since 1999, it is necessary to perceive the knowledge accurately and prepare for the successful implementation of it. Therefore, the literature review including screening and diagnostic audiometry, cochlear implants and hearing aids, and aural rehabilitation, telecommunications technology regarding several fields of teleaudiology, and considerations for practicing were identified. Although overall internet-based audiological services showed benefits in terms of outcome and accessibility, uncertainties of cost-effectiveness, the optimal level of support, and a need for further studies of many aspects for teleaudiology has arisen. In the view of technology, the store-and-forward (asynchronous/hybrid) and a real-time (synchronous) methods were introduced with one applied and nine registered patents recorded from 2004 to 2020 for the invention of teleaudiology in the United States. Also, 10 checklists were suggested for planning teleaudiology practice from prior experience in hosting the teleaudiology program. Conclusively, it is hoped that this review sheds light on recognizing and improving the existing teleaudiology services and helps overcome the challenges faced in the era of pandemic and untact world to come.