• Title/Summary/Keyword: Hearing Aid

Search Result 175, Processing Time 0.031 seconds

Digital Hearing Aid Fitting Program Testing System Development (디지털 보청기 적합 검증을 위한 전기음향 시험장치 개발)

  • Jarng, Soon-Suck;Kwon, You-Jung;Lee, Je-Hyung
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.415-418
    • /
    • 2005
  • DSP chip parameters of a digital hearing aid (HA) should be optimally selected or fitted for hearing impaired persons. The more precise parameter fitting guarantees the better compensation of the hearing loss (HL). Digital HAs adopt DSP chips for more precise fitting of various HL threshold curve patterns. A specific DSP chip such as Gennum GB3211 was designed and manufactured in order to match up to about 4.7 billion different possible HL cases with combination of 7 limited parameters. This paper deals with a digital HA fitting program which is developed for optimal fitting of GB3211 DSP chip parameters. The fitting program has completed feature from audiogram input to DSP chip interface. The compensation effects of the microphone and the receiver are also included. The paper shows some application examples.

  • PDF

Digital Hearing Aids Specific $\mu$DSP Chip Design by Verilog HDL

  • Jarng, Soon-Suck;Chen, Lingfen;Kwon, You-Jung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.190-195
    • /
    • 2005
  • The hearing aid chip described in this paper is an analog & digital mixed system. The design focuses on the$\mu$DSP core. This $\mu$DSP core includes internal time delays to two inputs from front and rear microphones. The paper consists of two parts; one is the composure and signal processing algorithm of digital hearing aids and the other is Verilog HDL codes for$\mu$DSP cores. All digital modules in the design were coded and synthesized by Verilog HDL codes which were verified by Mentor Graphics and Synopsis semiconductor chip design tools.

  • PDF

PCB layout for ITE digital hearing aids manufacture (귀속형 디지털 보청기 제작을 위한 PCB설계)

  • Jarng, Soon-Suck;Kim, Kyoung-Suck
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.577-579
    • /
    • 2004
  • Digital hearing aids enclose $6{\sim}8$ tiny components. Those electromechanical components are individually wired by soldering which is a manual labor and sometimes causes components' damage by heating. This paper suggests a PCB design for overcome these problems. Several PCBs are designed and manufactured and circuited to produce ITE(In The Ear) type hearing aids which are inserted in the ear canal. The most optimal size of the PCB design for the ITE hearing aid is presented in this paper.

  • PDF

PCB Layout for Digital Hearing Aids (디지털 보청기용 PCB 제작)

  • Jarng, Soon-Suck;Kim, Kyoung-Suck;Kwon, You-Jung
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1012-1015
    • /
    • 2004
  • Digital hearing aids enclose $6{\sim}8$ tiny components. Those electromechanical components are individually wired by soldering which is a manual labor and sometimes causes components' damage by heating. This paper suggests a PCB design for overcome these problems. Several PCBs are designed and manufactured and circuited to produce ITE(In-the-Ear) type hearing aids which are inserted in the ear canal. The most optimal size of the PCB design for the ITE hearing aid is presented in this paper.

  • PDF

Acoustic Masking Effect That Can Be Occurred by Speech Contrast Enhancement in Hearing Aids (보청기에서 음성 대비 강조에 의해 발생할 수 있는 마스킹 현상)

  • Jeon, Y.Y.;Yang, D.G.;Bang, D.H.;Kil, S.K.;Lee, S.M.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.1 no.1
    • /
    • pp.21-28
    • /
    • 2007
  • In most of hearing aids, amplification algorithms are used to compensate hearing loss, noise and feedback reduction algorithms are used and to increase the perception of speeches contrast enhancement algorithms are used. However, acoustic masking effect is occurred between formants if contrast is enhanced excessively. To confirm the masking effect in speeches, the experiment are composed of 6 tests; test pure tone test, speech reception test, word recognition test, pure tone masking test, formant pure tone masking test and speech masking test, and for objective evaluation, LLR is introduced. As a result of normal hearing subjects and hearing impaired subjects, more making is occurred in hearing impaired subjects than normal hearing subjects when using pure tone, and in the speech masking test, speech reception is also lower in hearing impaired subjects than in normal hearing subjects. This means that acoustic masking effect rather than distortion influences speech perception. So it is required to check the characteristics of masking effect before wearing a hearing aid and to apply this characteristics to fitting curve.

  • PDF

Clinical Factors Influencing the Trial and Purchase of Bilateral Microphones with Contralateral Routing of Signal in Patients with Asymmetric Sensorineural Hearing Loss

  • Seong, Jeon;Yang, Seung Koo;Jang, Pilkeun;Lee, Sang-Yeon;Carandang, Marge;Choi, Byung-Yoon
    • Journal of Audiology & Otology
    • /
    • v.24 no.1
    • /
    • pp.29-34
    • /
    • 2020
  • Background and Objectives: Bilateral microphones with contralateral routing of signal (BiCROS) hearing aid is an option for hearing rehabilitation in individuals with asymmetric sensorineural hearing loss (ASNHL). The clinical factors influencing the trial and purchase of BiCROS were investigated. Subjects and Methods: We reviewed the medical records of 78 patients with ASNHL who were recommended to use BiCROS and analyzed the demographic and audiological factors influencing the trial and purchase of BiCROS. Results: Among the 78 patients, 52 (66.7%) availed of the free BiCROS trial and 21 (26.9%) purchased BiCROS. The mean pure tone audiometry (PTA) air conduction (AC) threshold of the better- and worse-hearing ears were 44.2±12.8 dB and 90.7±22.5 dB HL, respectively. The decision for trial or purchase of BiCROS was not influenced by age, sex, duration of hearing loss of the worse-hearing ear, or PTA AC threshold or speech discrimination score of both ears. The first and third quartiles of the PTA AC thresholds for the better-hearing ear of BiCROS buyers were 38.75 dB and 53.75 dB HL, respectively. The counterpart values for the worse-hearing ear were 72.50 dB and 118.75 dB HL, respectively. Conclusions: The clinical factors analyzed in this study were found to be irrelevant to the trial and purchase of BiCROS in patients with ASNHL. Nevertheless, the distribution range of the auditory thresholds of the subjects using BiCROS can be a useful basis for the counseling of patients with ASNHL and selection of candidates for BiCROS use.

Design of External Coil System for Reducing Artifact of MR Image due to Implantable Hearing Aid (이식형 보청기에 의한 자기공명 영상의 인공음영 축소를 위한 외부 코일 시스템 설계)

  • Ahn, Hyoung Jun;Lim, Hyung-Gyu;Kim, Myoung Nam;Cho, Jin-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.2
    • /
    • pp.375-385
    • /
    • 2016
  • Recently, several implantable hearing aids such as cochlear implant, middle ear implant, etc., which have a module receiving power and signal from outside the body, are frequently used to treat the hearing impaired patients. Most of implantable hearing aids are adopted permanent magnet pairs to couple between internal and external devices for the enhancement of power transmission. Generally, the internal device which containing the magnet in the center of receiving coil is implanted under the skin of human temporal bone. In case of MRI scanning of a patient with the implantable hearing aid, however, homogeneous magnetic fields of the MRI might be interfered by the implanted magnet. For the above reasons, the MR image is degraded by large area of artifact, so that diagnostics are almost impossible in deteriorated region. In this paper, we proposed an external coil system that can reduce the artifact of MR image due to the internal coupling magnet. By finite element analysis estimating area of MR artifact according to varying current and shape of the external coil, optimal coil parameters were extracted. Finally, the effectiveness of the proposed external coil system was verified by confirming the artifact at real MRI scan.

Design of a new digital hearing aid based on a multi-band compensation technique (다중밴드 이득 보정기능을 갖는 디지털 청력보정회로 설계)

  • Choi Won-Chul;Lee Je-Hoon;Kim Young-Ju;Cho Kyoung-Rok
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.41 no.1
    • /
    • pp.41-54
    • /
    • 2004
  • In this paper, we propose a new digital hearing aid circuit that compensates the impaired threshold level changing nonlinearly using a multi-band compensation technique. In the algorithm the hearing frequency range 8kHz is divided into 64 bands which is 125Hz resolution. Each band is controlled finely to compensate the hearing impaired proportional to personal ROM table. The multi-band is introduced using a FFT/IFFT Processor which makes to control in frequency domain. As a result, the proposed circuit is more efficient $15\%$ than a conventional ones such as FIR filter architecture in terms of the compensation gun and accuracy. The hardware size was reduced $65\%$ than a general FFT by pre-handling of the input data.

Optimal Design for CMOS Analog Hearing Aid OP Amp Circuit (CMOS 아날로그 보청기 증폭회로의 최적 설계)

  • Jarng Soon-Suck;Chen Lingfeng
    • Proceedings of the IEEK Conference
    • /
    • 2004.06b
    • /
    • pp.443-446
    • /
    • 2004
  • Short channel IC circuits become increasingly important in modern high performance electronic systems. In this paper, parts of an analog hearing aid, an amplifier and a regulator, which are implemented with short channel CMOS devices, are designed and optimized in its performance.

  • PDF

Technical standards on magnetic field strength for a hearing-aid-compatible telephone (보청기 호환성 전화기의 자계세기에 관한 기술기준)

  • Kang, Kyeong-Ok;Kang, Seong-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.13 no.3
    • /
    • pp.78-84
    • /
    • 1994
  • 보청기가 자계 pick-up 코일을 구비하고 있고, 전화 수화기에서 충분한 자계를 발생할 경우의 전화 수화기와 보청기의 자기결합을 이용한 전화기를 보청기 호환성 전화기 (hearing-aid-compatible telephone)라고 한다. 본 고에서는 보청기와 전화 수화기의 결합방법과 자계결합에 관한 국제 기준을 고찰하여, 국내의 보청기 호환성 전화기의 자계 기준 및 측정법에 관한 검토사항을 제시한다.

  • PDF