• 제목/요약/키워드: Hearing Aid

검색결과 175건 처리시간 0.032초

이식형 마이크로폰과 진동체를 갖는 인공중이의 이득 보상을 위한 주파수 특성 고찰 (Study on frequency response of implantable microphone and vibrating transducer for the gain compensation of implantable middle ear hearing aid)

  • 정의성;성기웅;임형규;이장우;김동욱;이정현;김명남;조진호
    • 센서학회지
    • /
    • 제19권5호
    • /
    • pp.361-368
    • /
    • 2010
  • ACROSS device, which is composed of an implantable microphone, a signal processor, and a vibrating transducer, is a fullyimplantable middle ear hearing device(F-IMEHD) for the recovery of patients with hearing loss. And since a microphone is implanted under skin and tissue at the temporal bones, the amplitude of the sound wave is attenuated by absorption and scattering. And the vibrating transducer attached to the ossicular chain caused also the different displacement from characteristic of the stapes. For the gain control of auditory signals, most of implantable hearing devices with the digital audio signal processor still apply to fitting rules of conventional hearing aid without regard to the effect of the implanted microphone and the vibrating transducer. So it should be taken into account the effect of the implantable microphone and the vibrating transducer to use the conventional audio fitting rule. The aim of this study was to measure gain characteristics caused by the implanted microphone and the vibrating transducer attached to the ossicle chains for the gain compensation of ACROSS device. Differential floating mass transducers (DFMT) of ACROSS device were clipped on four cadaver temporal bones. And after placing the DFMT on them, displacements of the ossicle chain with the DFMT operated by 1 $mA_{peak}$ current was measured using laser Doppler vibrometer. And the sensitivity of microphones under the sampled pig skin and the skin of 3 rat back were measured by stimulus of pure tones in frequency from 0.1 to 8.9 kHz. And we confirmed that the microphone implanted under skin showed poorer frequency response in the acoustic high-frequency band than it in the low- to mid- frequency band, and the resonant frequency of the stapes vibration was changed by attaching the DFMT on the incus, the displacement of the DFMT driven with 1 $mA_{rms}$ was higher by the amount of about 20 dB than that of cadaver's stapes driven by the sound presssure of 94 dB SPL in resonance frequency range.

청력 보정을 위한 고주파 증폭 회로 설계 (Design of High Frequency Boosting Circuits Compensating for Hearing Loss)

  • 이광;정영진
    • 전자공학회논문지
    • /
    • 제54권3호
    • /
    • pp.138-144
    • /
    • 2017
  • 본 논문에서는 노인성 난청으로 인한 청력도 감쇄를 보상하는 고주파 증폭 회로를 제안한다. 노인성 난청은 고음역(고주파 대역)의 청력도가 저음역(저주파대역)에 비해 더 떨어지는 저주파 통과 필터의 특성을 보이므로, 보상회로는 임계주파수 이상의 대역에서는 주파수에 비례하여 신호를 증폭하고 임계주파수 이하에서는 증폭도를 일정하게 유지하는 구조이다. 제안된 고주파 회로는 미분기, 단위 이득 증폭기로 구성된다. 임계주파수는 볼륨 조절 레버 형태로 간단하게 제어가 가능한 구조로 노인들이 자신의 난청정도에 따라 쉽게 증폭도를 조절할 수 있다. 고주파 증폭회로의 임계주파수는 가청주파수 전 대역에서 연속적으로 조절 가능하고, 10 kHz 음역의 신호는 80dB 이상 증폭도를 가진다.

가변 스텝 크기 적응 필터와 음성 검출기를 이용한 보청기용 피드백 제거 알고리즘 (A Variable Step-Size Adaptive Feedback Cancellation Algorithm based on GSAP in Digital Hearing Aids)

  • 안홍섭;박규석;송지현;이상민
    • 전기학회논문지
    • /
    • 제62권12호
    • /
    • pp.1744-1749
    • /
    • 2013
  • Acoustic feedback is perceived as whistling or howling, which is a major complaint of hearing-aids users. Acoustic feedback cancellation is important in hearing-aids because acoustic feedback degrades performance of the hearing aid device by reducing maximum insertion gain. Adaptive systems for estimate acoustic feedback path and feedback suppression algorithms have been proposed in order to solve this problem. A typical feedback cancellation algorithm is LMS(least mean squares) because of its computational efficiency. However it has problem of convergence performance in high correlated input signal. In this paper, we propose a new variable step-size normalized LMS(least mean squares) algorithm using VAD(voice activity detection) to overcome the limitation of the LMS algorithm. The VAD algorithm is GSAP(global speech absence probability) and the feedback cancellation algorithm is normalized LMS. The proposed algorithm applies different step-size between voice and non-voice using VAD, for high stability, fast convergence speed and low misalignment when correlated inputs, such as speech. The result of simulation with white noise mixed speech signal, the proposed algorithm shows high performance then traditional algorithm in terms of stability, convergence speed and misalignment.

장애유형별 편의시설에 대한 평가 및 개선요구에 관한 연구 (A Study on the Disabled′s Assessment of Accommodation Facilities and Needs for Improving the Facilities)

  • 이연숙;장윤정;이기정
    • 한국실내디자인학회논문집
    • /
    • 제26호
    • /
    • pp.112-120
    • /
    • 2001
  • This study investigated the extend to which the facilities satisfactorily accommodate people with different disabilities and their specific needs for improving the facilities. Systematic interviews were conducted with 90 disabled people using the non-propertionate stratified cluster random sampling method. Frequency analysis, Chi-square tests, Duncan tests, and analysis of variance(ANOVA) were employed for data analysis. The findings indicated that the respondents' assessment of accommodations and needs for improving accommodations differed by the type of disabilities. People with physical disabilities were the least satisfied with stairs, followed by seating in stadiums and/or theaters. For people with visual disabilities, the lack of guidance and information facilities was the most difficult problem. People with hearing disabilities often pointed out difficulties in using public telephones. meanwhile, people with physical disabilities asked for easy access to assistive devices and improved mobility-related circumstances. yet people with visual disabilities expected to improve way-finding relevant issues, such as detectable warnings on walking surfaces and guidance and information facilities, whereas people with hearing disabilities desired to develop hearing-aid equipments, such as TDD and assistive listening systems.

  • PDF

디지털 보청기를 위한 저전력, 저잡음 전치증폭기 설계 (Desgin of Low-power, Low-noise Preamplifier for Digital Hearing-Aids)

  • 임새민;박상규
    • 전자공학회논문지
    • /
    • 제49권12호
    • /
    • pp.219-225
    • /
    • 2012
  • 디지털 보청기용 저전력, 저잡음 전치증폭기를 설계하였다. 본 전치증폭기는 일렛트렛 마이크로부터 싱글엔드 형태로 입력 받은 신호를 증폭한 후, 차동신호의 형태로 ADC에 전달한다. 또, 3.6, 7.2, 14.4, 28.8의 가변이득을 가지며 100Hz~10kHz의 주파수 대역에서 동작한다. 설계된 증폭기는 130nm CMOS 공정으로 제작되었으며, 1.2V 전원을 사용하여 측정한 결과 85dB의 SNR, 0.05%의 고조파 왜곡 및 $200{\mu}W$의 파워소모를 얻었다.

Comparison of treatment options in meniere's disease

  • Eshita, Ishrat Rafique
    • 식품보건융합연구
    • /
    • 제5권5호
    • /
    • pp.27-31
    • /
    • 2019
  • Meniere's disease (MD) is a disease that affects the inner ear. It is formed as a result of endolymphatic hydrops. Hearing loss and vertigo are important in the diagnosis of MD. There is fluctuating and progressive hearing loss. Vertigo attacks cause severe dizziness in the patient. There are many treatment options in MD. These are hearing aid, diet, medication and surgery. In this study, we will discuss the advantages and disadvantages of the different treatment options. Treatment options have been compared to find out what the appropriate treatment is. Another concern is the importance of surgery in MD. This study is combination of qualitative and quantitative studies. Much focus will be on vertigo, and appropriate treatment options of MD will be mentioned also the importance of surgery. The main question in this study is the necessity of surgery. Surgical procedures are the most doubtful treatment option because of their indications and contraindications. In this study, it has been noticed that surgical operation should be delayed as much as possible. Priority is to try other treatment options. Surgery can be considered as a last resort. When we look at the operations performed, operations are mostly done in advanced Meniere cases.

이식형 인공중이 시스템을 위한 차동 플로팅매스형 전자 튜랜스듀서 (DFMT Electromagentic Transducer for Implantable Middle Ear Hearing Aid)

  • 송병섭;박재훈;윤영호;배상곤;채승표;김명남;이상흔;이건일;조진호
    • 대한의용생체공학회:의공학회지
    • /
    • 제20권5호
    • /
    • pp.625-632
    • /
    • 1999
  • 이식형 인공중이에 사용되는 전자트랜스듀서는 압전형 트랜스듀서에 비해 음향특성은 좋으나 부피가 크고 효율이 낮으며 수술시 정밀한 코일-자석 간격 조정이 필요하며, 최근 제안된 FMT 트랜스듀서는 외부 자장의 변화에 민감하다는 문제점이 지적되고 있다. 본 논문에서는 코일-자석 간격조정이 필요 없고 외부자장에 영향을 받지 않는 차동 플로팅메스형 전자 트랜스듀서를 제안하였다. 제안된 방식은 2개의 소형 자석을 같은 극끼리 접합함으로써 외부자장에 대해 영향을 받지 않고 효율이 높은 등의 장점을 가진다. 제안된 트랜스듀서의 진동력 및 효율에 관한 정량적인 해석을 하였으며 기존의 트랜스듀서와 비교분석을 행하였다. 그리고 공급전류에 대해 발생되는 진동력의 크기를 계산함으로서 실제 이식형 인공중이의 제작에 필요한 객관적인 설계데이타를 제시하였다. 한편, 시험 제작된 트랜스듀서의 해석결과 제안한 트랜스듀서는 기존의 FMT 트랜스듀서보다도 효율이 1.5배 정도의 향상됨을 보였으며 무부하시험 및 사체의 이소골 진동실험을 통하여 적절한 진동을 효과적으로 이소골에 전달할 수 있음을 보였다.

  • PDF

FEA를 이용한 이식형 인공중이용 차동전자 트랜스듀서의 진동 모델링과 최적 설계 (Vibration Modeling and Optimal Design of Differential Electromagnetic Transducer for Implantable Middle Ear Hearing Devices using the FEA)

  • 김민규;임형규;한찬호;송병섭;박일용;조진호
    • 한국음향학회지
    • /
    • 제24권7호
    • /
    • pp.379-386
    • /
    • 2005
  • 최근까지 개발되었던 청각 보조기 중에서 공기 전도형 보청기의 하울링 (howling) 현상과 수술 후 이소골 등 기존 음향계의 재생이 불가능한 인공 와우 (cochlear implant system)의 단점을 해결하고, 동시에 청음 명료도가 높은 음성 신호를 전달하기 위한 수단으로 연구된 것이 인공중이 (implantable middle ear hearing device) 이다. 본 연구에서는 인공중이의 음성 신호 재현을 위한 진동 장치인 차동전자 트랜스듀서 (differential electromagnetic transducer, DET)에 대한 수학적 모형화와 계의 진동을 기술하는 운동방정식을 유도하고 그 해를 구하였다. 제한된 크기와 인가 전류 $1\;mA_{rms}$ 정현파에서 최대 구동력을 얻기 위해서 전자기력에 대한 유한요소해석을 수행하였고, 결과에 의해서 자석과 코일에 대한 최적 크기를 결정하였다. 사람의 중이 내 등자뼈 (stapes)의 진동 특성과 유사한 진동을 갖는 DET를 설계하기 위해서, 진동막의 강성계수를 변화하면서 진동해석을 시뮬레이션 하였다. 설계된 DET는 마이크로 머시닝 기술에 의해서 제작하였고, 그 진동 특성을 측정 하였다. 최종적으로 측정된 진동 특성에 대한 분석을 통하여 인공중이를 위한 진동 장치로서의 적용 가능함을 확인하였다.

완전 이식형 보청기를 위한 진동 기반의 가속도 센서 제안 (Proposition of a Vibration Based Acceleration Sensor for the Fully Implantable Hearing Aid)

  • 신동호;문하준;성기웅;조진호
    • 재활복지공학회논문지
    • /
    • 제11권2호
    • /
    • pp.133-141
    • /
    • 2017
  • 하이브리드 음향센서 (hybrid acoustic sensor)는 음압 기반의 음향센서 (ECM)와 진동 기반의 가속도 센서(acceleration sensor)가 접목된 구조이다. 이는 음향센서의 저주파 대역 감도와 가속도 센서의 고주파 대역 감도를 결합하여 저주파에서 고주파 대역까지 광범위하게 음향을 포집할 수 있다. 본 논문에서는 하이브리드 음향센서에 사용되는 가속도 센서를 제안하였다. 가속도 센서는 음향신호에 의해 발생되는 고막의 진동을 포집한다. 제안된 가속도 센서의 사이즈는 고막의 해부학적 구조와 음향센서인 ECM의 규격을 고려하여 직경 3.2 mm로 결정하였다. 그리고 하이브리드 음향센서가 고감도 광대역 특성을 가지도록 하기 위해서는 가속도 센서의 공진 주파수는 3.5 kHz 부근에서 생성되는 것을 목표로 하였다. 가속도 센서를 구성하는 진동막은 수학적 모델과 유한요소 해석을 통하여 기하학적 구조를 도출하였다. 이를 바탕으로 화학적 식각공정을 이용하여 진동막을 제작하였다. 그리고 제작된 진동막의 주파수 특성을 확인하기 위하여 외력에 의한 진동 측정 실험을 수행하였고, 실험 결과 진동막의 기계적 공진은 3.4 kHz에서 발생되었다. 그러므로 제안한 가속도 센서는 하이브리드 음향센서에 유용하게 활용될 수 있을 것으로 판단된다.

디지털 보청기 벤트 반향제거를 위한 부밴드 성긴 적응필터 (Subband Sparse Adaptive Filter for Echo Cancellation in Digital Hearing Aid Vent)

  • 배현덕
    • 한국정보전자통신기술학회논문지
    • /
    • 제11권5호
    • /
    • pp.538-542
    • /
    • 2018
  • 디지털보청기 벤트에서 발생되는 반향은 사용자의 불편을 초래한다. 벤트에서 귀환되는 반향을 제거하기 위해서는 귀환경로인 벤트의 임펄스응답의 정확한 추정이 요구된다. 벤트의 임펄스응답은 시간에 따라 변하는 특성과 함께 성긴 특성을 가진다. 이러한 특성의 벤트 임펄스응답 추정에 유용한 적응 알고리즘으로는 IPNLMS가 유용한 것으로 알려져 있다. 본 논문에서는 벤트의 성긴 임펄스응답을 추정하여 벤트에 의한 반향의 제거를 위해 IPNLMS를 부밴드 보청기 구조에 적용하는 부밴드 성긴 적응필터를 제안한다. 제안 기법에서 신호의 부밴드 분해는 각 대역 신호의 사전백색화가 가능하므로 적응필터의 수렴속도의 개선이 가능하다. 그리고 적응필터의 다위상 분해는 각 다위상 성분 필터에서 성긴도를 증가시키며, 추가 계산 없이 반향제거 성능개선이 가능하다. 제안 적응필터의 계수갱신 식 유도를 위해 가중 NLMS에 근거한 비용함수를 정의하고 이를 이용 각부밴드에서 적응필터의 계수 갱신 식을 유도한다. 제안한 적응필터의 성능검증을 위해 백색신호를 입력으로 하여 수렴속도와 정상상태오차를, 실제 음성신호를 입력으로 하여 반향제거 결과를 기존 알고리즘과 비교 평가한다.