• Title/Summary/Keyword: Hearing Aid

Search Result 175, Processing Time 0.025 seconds

A CMOS Single-Supply Op-Amp Design For Hearing Aid Application

  • Jarng, Soon-Suck;Chen, Lingfen;Kwon, You-Jung
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.206-211
    • /
    • 2005
  • The hearing aids specific operational amplifier described in this paper is a single-supply, low voltage CMOS amplifier. It works on 1.3V single-supply and gets a gain of 82dB. The 0.18${\mu}m$ CMOS process was chosen to reduce the driven voltage as well as the power dissipation.

  • PDF

Better Understanding of Direct Bone-Conduction Measurement: Comparison with Frequency-Specific Bone-Conduction Tones and Brainstem Responses

  • Kim, Yeoju;Han, Woojae;Park, Sihun;You, Sunghwa;Kwak, Chanbeom;Seo, Youngjoon;Lee, Jihyeon
    • Journal of Audiology & Otology
    • /
    • v.24 no.2
    • /
    • pp.85-90
    • /
    • 2020
  • Background and Objectives: The present study aimed to compare thresholds of direct bone-conduction (BC direct) with those of behaviorally measured BC pure-tone audiometry (PTA) and objectively measured BC auditory brainstem response (ABR) to confirm the clinical feasibility of their relationships. Subjects and Methods: Young adults with normal hearing participated in the study to determine the thresholds from three measurements at four testing frequencies. In the BC direct, the vibrator of a bone-anchored hearing aid softband was placed on the right mastoid of each subject. In both PTA and ABR, a B71 bone oscillator was placed on the subject's right mastoid. While the subject's thresholds of BC direct and BC PTA were determined with a clinically routine 5-dB step procedure, BC ABR was conducted to determine the individual's hearing sensitivity by a peak V of the waveform using tone-burst and click stimuli. Results: The BC direct showed a different pattern between low and high frequencies. Precisely, its thresholds were 13.25 and 12.25 dB HL at 0.5 and 1 kHz, respectively, but 19 and 19.75 dB HL at 2 and 4 kHz, respectively. A significant positive correlation existed between BC direct and PTA at 1 kHz, which was also correlated with ABR. Conclusions: Based on the current data, the thresholds of BC direct were similar to BC PTA at low frequencies and BC ABR at high frequencies. The thresholds of BC direct might be predictable at approximately 5 dB higher (or lower) than that in PTA, although a large data set is required for standardization.

Better Understanding of Direct Bone-Conduction Measurement: Comparison with Frequency-Specific Bone-Conduction Tones and Brainstem Responses

  • Kim, Yeoju;Han, Woojae;Park, Sihun;You, Sunghwa;Kwak, Chanbeom;Seo, Youngjoon;Lee, Jihyeon
    • Korean Journal of Audiology
    • /
    • v.24 no.2
    • /
    • pp.85-90
    • /
    • 2020
  • Background and Objectives: The present study aimed to compare thresholds of direct bone-conduction (BC direct) with those of behaviorally measured BC pure-tone audiometry (PTA) and objectively measured BC auditory brainstem response (ABR) to confirm the clinical feasibility of their relationships. Subjects and Methods: Young adults with normal hearing participated in the study to determine the thresholds from three measurements at four testing frequencies. In the BC direct, the vibrator of a bone-anchored hearing aid softband was placed on the right mastoid of each subject. In both PTA and ABR, a B71 bone oscillator was placed on the subject's right mastoid. While the subject's thresholds of BC direct and BC PTA were determined with a clinically routine 5-dB step procedure, BC ABR was conducted to determine the individual's hearing sensitivity by a peak V of the waveform using tone-burst and click stimuli. Results: The BC direct showed a different pattern between low and high frequencies. Precisely, its thresholds were 13.25 and 12.25 dB HL at 0.5 and 1 kHz, respectively, but 19 and 19.75 dB HL at 2 and 4 kHz, respectively. A significant positive correlation existed between BC direct and PTA at 1 kHz, which was also correlated with ABR. Conclusions: Based on the current data, the thresholds of BC direct were similar to BC PTA at low frequencies and BC ABR at high frequencies. The thresholds of BC direct might be predictable at approximately 5 dB higher (or lower) than that in PTA, although a large data set is required for standardization.

Simulation of the Loudness Recruitment using Sensorineural Hearing Impairment Modeling (감음신경성 난청의 모델링을 통한 라우드니스 누가현상의 시뮬레이션)

  • Kim, D.W.;Park, Y.C.;Kim, W.K.;Doh, W.;Park, S.J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.63-66
    • /
    • 1997
  • With the advent of high speed digital signal processing chips, new digital techniques have been introduced to the hearing instrument. This advanced hearing instrument circuitry has led to the need or and the development of new fitting approach. A number of different fitting approaches have been developed over the past few years, yet there has been little agreement on which approach is the "best" or most appropriate to use. However, when we develop not only new hearing aid, but also its fitting method, the intensive subject-based clinical tests are necessarily accompanied. In this paper, we present an objective method to evaluate and predict the performance of hearing aids without the help of such subject-based tests. In the hearing impairment simulation (HIS) algorithm, a sensorineural hearing impairment model is established from auditory test data of the impaired subject being simulated. Also, in the hearing impairment simulation system the abnormal loudness relationships created by recruitment was transposed to the normal dynamic span of hearing. The nonlinear behavior of the loudness recruitment is defined using hearing loss unctions generated from the measurements. The recruitment simulation is validated by an experiment with two impaired listeners, who compared processed speech in the normal ear with unprocessed speech in the impaired ear. To assess the performance, the HIS algorithm was implemented in real-time using a floating-point DSP.

  • PDF

Feasibility of hearing aid gain self-adjustment using speech recognition (말소리 인지를 이용한 보청기 이득 자가 조절의 실현)

  • Yun, Donghyeon;Shen, Yi;Zhang, Zhuohuang
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.1
    • /
    • pp.76-86
    • /
    • 2022
  • Personal hearing devices, such as hearing aids, may be fine-tuned by allowing the users to conduct self-adjustment. Two self-adjustment procedures were developed to collect the listener preferred gains in six octave-frequency bands from 0.25 kHz to 8 kHz. These procedures were designed to allow rapid exploration of a multi-dimensional parameter space using a simple, one-dimensional user control interface (i.e., a programmable knob). The two procedures differ in whether the user interface controls the gains in all frequency bands simultaneously (Procedure A) or only the gain in one frequency band (Procedure B) on a given trial. Monte-Carlo simulations suggested that for both procedures the gain preference identified by simulated listeners rapidly converged to the ground-truth preferred gain profile over the first 20 trials. Initial behavioral evaluations of the self-adjustment procedures, in terms of test-retest reliability, were conducted using 20 young, normal-hearing listeners. Each estimate of the preferred gain profile took less than 20 minutes. The deviation between two separate estimates of the preferred gain profile, conducted at least a week apart, was about 10 dB ~ 15 dB.

A Study on Speech Recognition Estimation of Cochlea Dead Region and Amplification Gains According to Frequency Bands (주파수 영역별 Cochlea Dead Region과 증폭 이득에 따른 어음인지능력 평가 연구)

  • Park, G.S.;Bang, D.H.;Lee, S.M.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.5 no.1
    • /
    • pp.41-46
    • /
    • 2011
  • A sensorineural hearing loss(SNHL) occurs when the cochlea in the inner has functional problem. The region in the cochlea with no(or very few) functioning inner hair cells or neurons called 'dead regions'. Amplification using hearing aid over a frequency range corresponding to a dead region may not a beneficial. In this paper, we compared speech recognition with different location of dead region and gain and searched effective gain for hearing aid with dead region. In order to experiment, eight people who has normal hearing ware tested, and we used white noise and babble noise(SNR=0 dB). we divided by three conditions, low, mid and high frequency dead region. In addition, the gains in dead region ware 14.5 dB, 11.5dB and 6 dB gain. There ware different results by location of dead region. The result of WRS and preference in mid-frequency dead region and high-frequency dead region ware higher than them in low-frequency dead region. When we compared as gains, the score of WRS with lower gain was higher than 14.5 dB gain, and the preference was lower as higher gain.

The Articulation Characteristics of the Profound Hearing-Impaired Children with Reference to Formant Bandwidth (심도 청각장애 아동의 조음 특성: 포먼트 대역폭을 중심으로)

  • Choi, Eunah
    • Phonetics and Speech Sciences
    • /
    • v.6 no.2
    • /
    • pp.55-64
    • /
    • 2014
  • This study measured formant bandwidths of profound hearing impaired children and examined the characteristics of their articulation. For this study, 10 cochlear implanted children(CI), 10 hearing aid children(HA) and 10 normal hearing children(NH) were asked to read 7 Korean vowels(/ɑ, ʌ, o, u, ɯ, i, ɛ/). The subjects' readings were recorded by NasalView and analyzed by Praat. The analysis of the formant bandwidths explains the degree of vocal fold opening and the characteristics of radiation. Through the analysis of formant bandwidth, we can see that the hearing-impaired maintain vocal fold tension when they speak high vowels and characteristics of radiation. Narrower B1 means better maintain vocal fold tension, wider B2 means more front and wider B3 means the rounder lips. CI's B1 was widest and NH's was narrowest. And females' B1 was wider than males'. Among vowels, B1 of /a/ was widest, and B1 of /i/ was narrowest. In the case of B2, HA and NH's B2 was wider than CI's. Females' B2 was wider than males'. And B2 of /i/ was widest, and B2 of /ʌ/ was narrowest. In the case of B3, NH's was widest, and CI's was narrowest. Males' was wider than females'. Among vowels, B3 of /o/ was widest, and B3 of /ɛ/ was narrowest. As a result, first, through the analysis of B1, we can find that NH and males could better maintain vocal fold tension than the hearing-impaired or females, and all children articulate /i/ with vocal fold tension than other vowels. Second, through the analysis of B2, NH and HA articulate vowels with the weaker rounded than CI does. And females articulate vowels with the weaker rounded than males do. Third, through the analysis of B3, NH articulate vowels with the rounder than HA or CI do, and males articulate vowels with the rounder than females do. Through the results, we can expect that the analysis of formant bandwidth will be applied to the therapy of articulation for the hearing-impaired with hearing aids or cochlear implant.

A Speech Enhancement Algorithm based on Human Psychoacoustic Property (심리음향 특성을 이용한 음성 향상 알고리즘)

  • Jeon, Yu-Yong;Lee, Sang-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.6
    • /
    • pp.1120-1125
    • /
    • 2010
  • In the speech system, for example hearing aid as well as speech communication, speech quality is degraded by environmental noise. In this study, to enhance the speech quality which is degraded by environmental speech, we proposed an algorithm to reduce the noise and reinforce the speech. The minima controlled recursive averaging (MCRA) algorithm is used to estimate the noise spectrum and spectral weighting factor is used to reduce the noise. And partial masking effect which is one of the human hearing properties is introduced to reinforce the speech. Then we compared the waveform, spectrogram, Perceptual Evaluation of Speech Quality (PESQ) and segmental Signal to Noise Ratio (segSNR) between original speech, noisy speech, noise reduced speech and enhanced speech by proposed method. As a result, enhanced speech by proposed method is reinforced in high frequency which is degraded by noise, and PESQ, segSNR is enhanced. It means that the speech quality is enhanced.

Design of Signal Processing Circuit for Semi-implantable Middle Ear Hearing Device with Bellows Transducer (벨로즈형 진동체를 갖는 반이식형 인공중이용 신호처리회로 설계)

  • Kim, Jong Hoon;Shin, Dong Ho;Seong, Ki Woong;Cho, Jin-Ho
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.11 no.1
    • /
    • pp.63-71
    • /
    • 2017
  • In this paper, a signal processing circuit for semi-implantable middle ear hearing device is designed using the TCBT which is recently proposed for a new middle ear transducer that can be implanted at round window of cochlea. The designed semi-implantable hearing device transmits digital sound signal from external device located at behind the ear to the internal device implanted under the skin using inductive coupling link methods with high efficiency. The coils and signal processing circuits are designed and implemented considering the total transmission and reception distance including skin thickness of temporal bone for the semi-implantable hearing device. And also, to improve the data transmission efficiency, the output circuits which can supply sufficient signal power is designed. In order to confirm operation of semi-implantable hearing device using inductive coupling link, the circuit analysis was performed using PSpice, and the performance was verified by implementing a signal processing board of an available size.