• 제목/요약/키워드: Healthcare Device

검색결과 379건 처리시간 0.03초

Development of a Backpack-Based Wearable Proximity Detection System

  • Shin, Hyungsub;Chang, Seokhee;Yu, Namgyenong;Jeong, Chaeeun;Xi, Wen;Bae, Jihyun
    • 한국의류산업학회지
    • /
    • 제24권5호
    • /
    • pp.647-654
    • /
    • 2022
  • Wearable devices come in a variety of shapes and sizes in numerous fields in numerous fields and are available in various forms. They can be integrated into clothing, gloves, hats, glasses, and bags and used in healthcare, the medical field, and machine interfaces. These devices keep track individuals' biological and behavioral data to help with health communication and are often used for injury prevention. Those with hearing loss or impaired vision find it more difficult to recognize an approaching person or object; these sensing devices are particularly useful for such individuals, as they assist them with injury prevention by alerting them to the presence of people or objects in their immediate vicinity. Despite these obvious preventive benefits to developing Internet of Things based devices for the disabled, the development of these devices has been sluggish thus far. In particular, when compared with people without disabilities, people with hearing impairment have a much higher probability of averting danger when they are able to notice it in advance. However, research and development remain severely underfunded. In this study, we incorporated a wearable detection system, which uses an infrared proximity sensor, into a backpack. This system helps its users recognize when someone is approaching from behind through visual and tactile notification, even if they have difficulty hearing or seeing the objects in their surroundings. Furthermore, this backpack could help prevent accidents for all users, particularly those with visual or hearing impairments.

노인 대상 맞춤형 운동서비스 프로그램 개발 및 사용성 평가 (Development of Customized Exercise Service Program for Elderly and Evaluation of Usability)

  • 송요한;박일현;곽선영;이현민
    • 대한물리의학회지
    • /
    • 제17권4호
    • /
    • pp.151-160
    • /
    • 2022
  • PURPOSE: To evaluate the usability of a kiosk-based healthcare service that provides a fitness evaluation and customized exercise program for elderly or chronic musculoskeletal system patients. METHODS: To evaluate the usability of the customized exercise service program, healthy adults (n=20) from Welfare B, located in Gwangju, were selected and studied. Subjective safety, operability, and satisfaction of individual users were obtained as data by distributing questionnaires to subjects who experienced this program and having them fill out the questionnaire. For descriptive statistics related to the survey, frequency analysis was used to determine the frequency and ratio of the variable values of the measurement items. RESULTS: As a result of the usability evaluation, the average score was 4.166, and the average score of each item was 4.025 for safety, 4.272 for operability, and 4.143 for satisfaction. Most users obtained high satisfaction and positive impressions. CONCLUSION: The HARUFIT service, a user-customized exercise program used in this study, can be developed into a device that can improve self-management ability and increase understanding of health care by providing customized exercise based on the results of physical fitness evaluation. It is possible to diversify health management methods and maximize the effect of exercise by making exercise a habit of chronic musculoskeletal disease patients or the elderly using these smart devices.

하지 로봇재활의료기기의 안전성 및 필수성능 평가 기준 개발 (The Development of Safety and Essential Performance Criteria for Lower Extremity Robotic Assisted Gait Training System)

  • 강용완;권지연
    • 대한의용생체공학회:의공학회지
    • /
    • 제44권3호
    • /
    • pp.190-203
    • /
    • 2023
  • The purpose of this study is to provide basic data to ensure the safety and essential performance of a Lower Extremity robotic assisted gait training system and to provide advanced technology and technical basis to the industry handling the system. Based on IEC 60601-1:2012/AMD2:2020 (Medical Electrical Equipment - General requirements for basic safety and essential performance of medical electrical equipment), IEC 62366-1:2015/AMD1:2020 (Medical devices - Part 1: Application of usability engineering to medical devices) and EN ISO 14971:2019 (Medical devices - Application of risk management to medical devices), the requirements for ensuring the safety and essential performance of the Lower Extremity robotic assisted gait training system were derived. Through the Delphi survey method and scenario analysis, which reflects the opinions and knowledge of experts in the fields of development, testing and review of technical documents, and quality assurance of medical devices, validity and reliability were conducted and obtained results with adequate content validity ratio (CVR; 0.7≤) and excellent reliability (Cronbach's α; 0.9≤). As a result, it was confirmed that the reliability and validity of the risk management process to ensure the safety and essential performance of the Lower Extremity robotic assisted gait training system are required a model can be established to provide measures to reduce risks according to the level of risk exposure caused by usage.

R 피크 검출 정확도를 개선한 홀터 심전도 모니터의 개발 (Development of Holter ECG Monitor with Improved ECG R-peak Detection Accuracy)

  • 최정현;강민호;박준호;권기구;배태욱;박준모
    • 융합신호처리학회논문지
    • /
    • 제23권2호
    • /
    • pp.62-69
    • /
    • 2022
  • 의료현장에서는 최근 디지털 헬스케어의 중요성이 대두되면서, 다양한 형태의 생체신호 측정 관련 연구가 활발히 진행되고 있다. 생체신호 중 가장 중요한 신호로 심전도를 들 수 있으며, 특히 부정맥 환자에 있어 심전도 신호의 연속 모니터링은 매우 중요하다. 부정맥은 동결절(sinus node), 동빈맥(sinus tachycardia), 심방조기수축(atrial premature beat, APB), 심실세동 (ventricular fibrillation) 등으로 그 발병원에 따른 형태가 다양하며, 발병 이후의 예후가 좋지 않으므로 일상 중 연속 모니터링은 부정맥의 조기 진단과 치료방향 설정에서 매우 중요하다. 부정맥 환자의 심전도 신호는 매우 불안정하며, 부정맥을 자동 검출하기 위한 주요 특징점으로 작용하는 정확한 R-peak 포인트의 검출이 어렵다. 본 연구에서는 연속 측정하는 홀터 심전도 모니터링 기기와 분석용 소프트웨어를 개발하였으며, 부정맥 데이터베이스를 통해 심전도 신호의 R-peak 효용성을 확인하였다. 향후 연구에서는 다양한 발병원인으로 인한 부정맥의 형태적 구분 및 예측을 위한 알고리즘과 임상 데이터에 근거한 유효성 검증에 관한 추가 연구가 필요하다.

국민인식을 기초로 한의사의 현대 진단의료기기 사용 법제화 필요성에 대한 제언 : 설문조사를 중심으로 (Should Korean Medicine doctors use modern diagnostic medical devices? Survey result of public perspectives)

  • 김주철;황병천;황만기;이승민;이은희;임정태
    • 대한한의학회지
    • /
    • 제43권3호
    • /
    • pp.94-105
    • /
    • 2022
  • Objectives: This study investigated public opinion on the use of modern diagnostic medical devices by Korean Medicine doctors. Methods: A questionnaire looking into perceptions on the use of modern medical devices was developed. It was distributed by a third party and data was collected. Results were analyzed through frequency analysis, chi-square analysis (χ2-test), frequency and cross analysis using R program. The measurement variable in the study was the respondent's perspectives and expectations on the use of modern diagnostic medical devices by Korean Medicine doctors. The maximum significance level was 0.05. Results: There were a total of 3,000 responses and 80.8% of the respondents replied that there is a need for government-level discussion on endowing rights to Korean Medicine doctors as supervisors for safety management of radiation generating devices. Also, 83.3% of the respondents agreed the use of ultrasound imaging equipment in Korean Medicine clinics should be legalized. Conclusions: According to this study, respondents strongly support the use of modern diagnostic medical devices by Korean Medicine doctors. This is the first study to investigate public opinion in this area and it provides a significant insight into the public needs and desires for a wider scope of practice for Korean Medicine in the healthcare system.

엉덩관절 안쪽돌림 조절을 위한 비탄력 테이핑 방법이 엉덩관절 근활성도에 미치는 영향 -예비연구- (Effect of the Non-Elastic Taping Method of Controlling Internal Hip Joint Rotation on Hip Muscle Activity: A Preliminary Study)

  • 배송의;정주현;문동철
    • PNF and Movement
    • /
    • 제21권3호
    • /
    • pp.281-289
    • /
    • 2023
  • Purpose: This study investigated the effects of the non-elastic taping method for controlling internal hip joint rotation on internal and external hip rotator muscle activity in healthy people. Methods: In this study, 18 healthy volunteers were instructed to perform the small knee bending (SKB) test. All participants completed the test following two methods (using non-elastic taping and not using taping). Muscle activation during the two methods was measured using a surface electromyography (EMG) device. Surface EMG data were collected from the gluteus medius, gluteus maximus, and tensor fasciae femoris muscles while performing the SKB test with and without non-elastic taping. Results: Muscle activity in the gluteus maximus was significantly higher during the SKB test with non-elastic taping than during the conventional SKB test with taping (p < 0.05). Tensor fasciae latae muscle activity was lower during the SKB test with non-elastic taping than during the conventional SKB test (p < 0.05). Conclusion: The findings suggest that the non-elastic taping method for controlling internal hip joint rotation effectively activates the hip's external rotator muscles and minimizes unwanted internal rotator muscle use during the SKB test. Therefore, the non-elastic taping method for controlling internal hip joint rotation could be an effective intervention for those who cannot control the internal rotation of their hips.

The Reliability and Validity of a Portable Hand-held Spirometer for the Measurement of Various Lung Functions in Healthy Adults

  • Merve Nur Uygun;Jun-Min Ann;Byeong-Hyeon Woo;Hyeon-Myeong Park;Ha-Im Kim;Dae-Sung Park;In-Beom Jeong
    • Physical Therapy Rehabilitation Science
    • /
    • 제13권2호
    • /
    • pp.179-186
    • /
    • 2024
  • Objective: This study aims to assess the reliability and validity of the new hand-held spirometer as a potential substitute for traditional pulmonary function testing (PFT) devices. Design: Cross-sectional study. Methods: In this study, thirty healthy adults underwent spirometry using both the new hand-held spirometer and the MIR spirometer, which is a standard PFT device. Parameters including peak expiratory flow (PEF), forced expiratory volume in one second (FEV1), and forced vital capacity (FVC) were measured and analyzed for validity and reliability. Inter-rater reliability and validity were evaluated through 95% limits of agreement (LOA) and intraclass correlation coefficients (ICC). Statistical analyses, including the Bland-Altman plots and the ICC, were utilized to assess agreement between the two devices. Results: The new hand-held spirometer exhibited a good agreement with intra-class coefficient (ICC [2,1]) ranging 0.762 to 0.956 and 95% LOA of -1.94 to 1.80 when compared with MIR. The test-retest reliability of the hand-held spirometer analyzed using - ICC [2,1] demonstrated a good level of consistency (ICC [2,1] =0.849-0.934). Conclusions: In conclusion, the study aimed to assess the potential of the new hand-held spirometer as a viable alternative to traditional PFT devices, with a specific focus on its reliability and validity in spirometric measurements. The new hand-held spirometer exhibited good test-retest reliability across all measured variables, suggesting its potential as a valid and reliable tool for simultaneous PFT measurements.

치매환자를 위한 u-Health Care 시스템 개발 (Development of u-Health Care System for Dementia Patients)

  • 신동민;신동일;신동규
    • 한국통신학회논문지
    • /
    • 제38C권12호
    • /
    • pp.1106-1113
    • /
    • 2013
  • 치매와 같은 노인성 정신질환 환자들에게 운동량과 일광량은 환자의 투약량과 조절과 진료에 있어 중요한 단서가 된다. 따라서 환자들의 안전과 건강한 삶을 위해 일상생활의 건강정보 모니터링이 필수적이다. 이러한 서비스를 제공하기 위해 환자에게는 휴대가 간편하고 항상 착용 가능한 센서 디바이스와 데이터를 모니터링할 서버의 구성이 필요하다. 본 논문에서는 치매환자의 건강정보를 실시간으로 모니터링하고 관리하기 위해 환자가 착욕하는 시계형 디바이스(스마트 시계)와 서버시스템을 개발했다. 본 논문에서 개발한 스마트시계는 GPS, 가속도센서, 조도센서를 포함하며 환자의 위치 추적, 운동량, 일광량을 측정해 환자의 실시간 건강정보를 취득 할 수 있다. 서버시스템은 스마트시계를 통해 취득한 센서 데이터를 통해 의사, 보호자가 모니터링 할 수 있는 웹 서버와 센서 데이터의 분석 알고리즘을 포함한다. 본 논문에서 제안한 데이터 분석 알고리즘은 가속도센서를 통해 취득한 환자의 움직임에서 걸음 수를 검출해 운동량 정보를 취득하며 이를 검증하기 위해 빠른 걸음, 느린 걸음, 보통 걸음에 해당하는 3가지 경우로 실험한 결과 96%의 정확도를 보였다. 본 논문을 통해 개발된 치매환자를 위한 u-Health Care 시스템을 적용한다면 치매환자들에게 더 질 높은 의료서비스를 제공할 수 있을 것이다.

뇌졸중 환자의 로봇 재활 치료를 위한 실시간, 동시 및 비례형 근전도 제어 (Real-Time, Simultaneous and Proportional Myoelectric Control for Robotic Rehabilitation Therapy of Stroke Survivors)

  • 정영진;박혜연
    • 재활치료과학
    • /
    • 제7권1호
    • /
    • pp.79-88
    • /
    • 2018
  • 목적 : 본 연구에서는 뇌졸중 환자의 치료 효과를 증진시키기 위한 방법으로, 로봇 기반에 연속적이며, 실시간으로 환자의 의지에 따른 표면 근전도 신호에 비례한 제어가 가능한 최적 알고리즘을 구현 및 재활로봇과 PC소프트웨어에 적용기술을 개발하였다. 연구방법 : 뇌졸중 환자의 치료를 위한 재활로봇 제어 알고리즘 개발을 위해서 본 연구에서는 선형 재귀모델을 이용하였다. 또한, 이를 PC 소프트웨어에 적용하여 실제 근전도 신호에 비례하여 게임을 진행할 수 있도록 환경을 구축하였으며, 이를 활용하여 모의 훈련을 진행하였다. 결과 : 모의실험 결과 실제 움직인 위치와 선형 재귀모델로부터 추정된 위치의 결과가 상당히 유사하게 나타나는 것을 확인할 수 있었다. 또한 3명의 피험자를 대상으로 실험 한 결과, 3번의 각기 다른 시도에 따라 훈련이 진행되면서 그 결과가 좋아짐을 확인할 수 있었다. 결론 : 본 연구에서는 재활로봇에 적용 가능한 실시간으로 동작하는 근전도에 비례한 움직임을 유도해 낼 수 있는 선형 재귀 모델을 개발하였다. 또한, 이를 활용한 소프트웨어도 함께 구축하여 그 활용 가능성이 높음을 확인하였다. 향후 실제 재활로봇에 적용하여 자가-재활 및 원격재활 로봇에 기본 알고리즘으로 널리 활용될 수 있을 것이라 기대된다.

감성 욕구와 인지 욕구의 개인차가 가상현실의 건강 조언에 미치는 영향 (The Effect of Individual Differences in Need for Affective and Cognitive on Health Advice in Virtual Reality)

  • 유상형;정유진;한광희
    • 감성과학
    • /
    • 제22권3호
    • /
    • pp.77-90
    • /
    • 2019
  • 본 연구는 기본 욕구의 개인차에 따라 메시지에 담긴 행동을 추구하는 데 효과적인 메시지 제공자가 다른지 알아보고자 하였다. Haddock, Maio, Arnold, & Huskinson (2008)에 의하면, 감성 욕구(NFA)가 높은 사람은 정서 기반의 메시지에, 인지 욕구(NFC)가 높은 사람은 인지 기반의 메시지에 더 영향을 받았다. 본 연구는 이러한 기본 욕구의 개인차가 메시지뿐 아니라 메시지 제공자에까지 적용할 수 있으리라 생각했다. 예를 들면, 감성 욕구가 높은 사람은 전문가보다 의미 있는 타인에게 전달받은 메시지를 더 잘 수용할 수 있다. 이에 따라, 본 연구는 VR에서 개인별 건강 조언에 효과적인 메시지 제공자를 파악하고자, 개인의 욕구 (2: NFA, NFC), 메시지 제공자 (3: 전문가, 의미 있는 타인, 타인) 그리고 VR 착용 (2: Text, VR)에 따른 선호도와 일상생활 스트레스 관리에 대한 자기 효능감을 측정하였다. 실험결과, 예상과 달리, 기본 욕구와 메시지 제공자의 특성에 따른 일치 효과는 발견할 수 없었다. 그러나, 감성 욕구가 높은 집단이 VR 건강 조언에 더 적합하다는 경향을 파악할 수 있었다. 본 연구의 의의는 VR 환경에서 개인의 맞춤형 메시지 제공자를 파악하고자 한 데 있다. 또한, 본 연구는 초기 단계의 연구로 추후 VR 환경의 건강 조언 연구에 기여하리라 예상한다.