• Title/Summary/Keyword: Health technology assessment

Search Result 838, Processing Time 0.027 seconds

The Review of Exposure Index in Digital Radiography and Image Quality (디지털 영상에서 화질관리에 관한 노출지수(EI)의 유용성 연구)

  • Yang, Sook;Han, Jae Bok;Choi, Nam Gil;Lee, Seong Gil
    • Journal of Radiation Protection and Research
    • /
    • v.38 no.1
    • /
    • pp.29-36
    • /
    • 2013
  • The aim of this study was to determine the correlation between exposure index (EI) and dose factors related to radiation dose optimization in digital radiography (DR) system. Two phantoms with built-in regional test object for quantitative assessment of images were used to produce image signals that acquired in chest radiography background. EI and entrane surface dose (ESD) increased proportionally with rise of radiation dose (kVp, mAs) in both DR and CR systems. Especially, DR detector was effective to form good contrast and hence, reached easily to improvement of image quality with minimal dose changes. It made operators possible to expect the accuracy of EI values deeply related to absorbed dose of the detector. The evaluation of images was obtained specially employed calculation of noise to signal ratio (NSR) and contrast to noise ratio (CNR). These measurements were performed for how exposure factors affect image quality. NSR was inversely proportional to kVp and mAs and low NSR represented high signal detection efficiency. Consequently, EI values was the measure of the amount of exposure received by the image receptor and it was proportional to exposure factors. Therefore the EI in a recommended range from manufacturer can offer optimal image quality. Also, continuous monitoring of EI values in the digital radiography can reduce the unnecessary patient dose and help the quality control of the system.

Construction of MIRD-type Korean Adult Male Phantom and Calculation of Dose Conversion Coefficients for Photon (한국 성인남성 MIRD형 모의피폭체 제작 및 광자 외부피폭 선량환산인자 산출)

  • Park, Sang-Hyun;Lee, Choon-Sik;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.2
    • /
    • pp.97-104
    • /
    • 2004
  • MIRD-type Korean adult male phantom, 'KMIRD' was constructed to calculate Korean-specific dosimetric quantities for radiation protection consideration. The external shape of KMIRD was based on national physical standard data of Korean. KMIRD has thicket trunk than MIRD5 and arm models divided from trunk. The height and weight of the KMIRD are 171 cm and 63.8 kg. ICRP23 data were referred to constitute organs and tissues of KMIRD. However nine organs were constructed based on Korean reference data provided by Radiation Health Research Institute. In the present study, the MCNPX2.3 Monte Carlo transport code was combined with KMIRD to calculate dose conversion coefficients for photon in the energy range from 0.05 to 10 MeV. The simulated irradiation geometries are broad parallel photon beams in AP, PA, LLAT and RLAT direction. Absorbed dose conversion coefficients were compared with data calculated with MIRD5, MIRD-type phantom based on ICRP23 reference man. In some organs, the discrepancies between two phantoms amount up to nearly 30%. The effective doses conversion coefficients of KMIRD are lower than those of MIRD5. The dose discrepancies between two MIRD-type phantoms ate because of physical differences between Korean and Western, also geometric differences between two phantoms. KMIRD should be revised using the full set of Korean reference data of all organs. The developed MIRD-type Korean adult male phantom can be applied to dose assessment of internal exposure.

Theory of X-ray microcomputed tomography in dental research: application for the caries research (치과 분야 연구에서 미세전산화 단층촬영술의 이론: 치아우식증에 대한 적용)

  • Park, Young-Seok;Bae, Kwang-Hak;Chang, Ju-Hea;Shon, Won-Jun
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.2
    • /
    • pp.98-107
    • /
    • 2011
  • Caries remains prevalent throughout modern society and is the main disease in the field of dentistry. Although studies of this disease have used diverse methodology, recently, X-ray microtomography has gained popularity as a non-destructive, 3-dimensional (3D) analytical technique, and has several advantages over the conventional methods. According to X-ray source, it is classified as monochromatic or polychromatic with the latter being more widely used due to the high cost of the monochromatic source despite some advantages. The determination of mineral density profiles based on changes in X-ray attenuation is the principle of this method and calibration and image processing procedures are needed for the better image and reproducible measurements. Using this tool, 3D reconstruction is also possible and it enables to visualize the internal structures of dental caries. With the advances in the computer technology, more diverse applications are being studied, such automated caries assessment algorithms.

A Study on Safety and Performance Evaluation of Smart All-in-one Cardiopulmonary Assist Device (스마트올인원 심폐순환보조장치의 안전성 및 성능평가에 관한 연구)

  • Park, Junhyun;Ho, YeJi;Lee, Yerim;Lee, Duck Hee;Choi, Jaesoon
    • Journal of Biomedical Engineering Research
    • /
    • v.40 no.5
    • /
    • pp.197-205
    • /
    • 2019
  • The existing Extracorporeal membrane oxygenation(ECMO) and Cardiopulmonary bypass system(CPB) have been developed and applied to various devices according to their respective indications. However, due to the complicated configuration and difficult usage method, it causes inconvenience to users and there is a risk of an accident. Therefore, smart all-in-one cardiopulmonary circulation device is being developed recently. The smart all-in-one cardiopulmonary assist device consists of a blood pump for cardiopulmonary bypass, a blood oxidizer for cardiopulmonary bypass, a blood circuit for cardiopulmonary bypass, and an artificial cardiopulmonary device. It is an integrated cardiopulmonary bypass device that can be used for a variety of purposes such as emergency, intraoperative, post-operative intensive care, and long-term cardiopulmonary assist, combined with CPB used in open heart surgery and ECMO used when patient's cardiopulmonary function does not work normally. The smart all-in-one cardiopulmonary assist device does not exist as a standard and international standard applicable to advanced medical devices. Therefore, in this study, we will refer to the International Standard for Blood Components, the International Standard for Blood, the Guideline for Blood Products, and prepare applicable performance and safety guidelines to help quality control of medical devices, and contribute to the improvement of the health of people. The guideline, which is the result of conducted a survey of the method of safety and performance test, is based on the principle of all-in-one cardiopulmonary aiding device, related domestic foreign standards, the status of domestic and foreign patents, related literature, blood pump(ISO 18242), blood oxygenator (ISO 7199), and blood circuit (ISO 15676) for cardiopulmonary bypass.The items on blood safety are as follows: American Society for Testing and Materials ASTM F1841-97R17), and in the 2010 Food and Drug Administration's Safety Assessment Guidelines for Medical Assisted Circulatory Devices. In addition, after reviewing the guidelines drawn up through expert consultation bodies including manufacturers / importers, testing inspectors, academia, etc. the final guideline was established through revision and supplementation process. Therefore, we propose guidelines for evaluating the safety and performance of smart all-in-one cardiopulmonary assist devices in line with growing technology.

Psychosomatic Integrative Care for Psychosocial Distress of Patients With Breast Cancer (유방암 환자의 정신사회적 디스트레스에 대한 정신신체의학적 통합치료)

  • Yang, Chan-Mo;Jang, Seung-Ho;Lee, Hye-Jin;Lee, Sang-Yeol
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.29 no.2
    • /
    • pp.77-85
    • /
    • 2021
  • Breast cancer is the most prevalent oncological disease among women. Various psychosocial distress is common at the diagnosis, treatment, and posttreatment phase of breast cancer. For the treatment of breast cancer, not only medical treatment but also psychosomatic integrative care will be needed. Patients with breast cancer may lead to increased vulnerability to stress, adjustment disorder, anxiety disorder, and depressive disorder, and these psychiatric diseases and conditions are associated with recurrence or exacerbation of breast cancer. Psychosocial treatment of anxiety and depression could increase the quality of life of patients and decrease the recurrence and progression of breast cancer. In this article, we reviewed 5 clinical breast cancer survivorship guidelines focused on psychosomatic integrative care including psychosocial treatment and alternative treatment for psychosocial distress. Because 5 treatment guidelines were using various definitions of evidence, we confirmed evidence of various psychosocial treatments for patients with breast cancer based on the definition of evidence by the US Preventive Service Task Force (USPSTF) guideline. We also reviewed the effect size of psychosocial treatment for anxiety, depression, mood, and quality of life in patients with breast cancer. This article discusses the barrier to the delivery of psychosomatic integrative care and suggests integrative care planning for breast cancer. Multi-disciplinary teams, patient's needs assessment, information technology support, patient and caregiver engagement, planned periodic monitoring of psychosocial distress by a psychosomatic specialist or consultation-liaison psychiatrist are recommended as key features of a psychosomatic integrated care plan.

Examples of NCS-based Learning Assessment: For the College of Radiotechnology (NCS 기반 학습평가 사례: 전문대학 방사선과 학생들을 대상으로)

  • Park, Jeongkyu
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.407-414
    • /
    • 2019
  • Recently, after the reorganization as the basis of NCS education, various learning methods are being sought for improving the basic occupational ability and job ability required by NCS, and the evaluation method accordingly is urgently needed. The purpose of this study was to evaluate the applicability of meta-cognitive learning and Havruta learning as evaluation cases in order to improve the job skills and basic skills required in the NCS curriculum. As a result, the meta-cognitive learning response sample statistic showed an average of 2.6883 when the pre-meta-cognitive learning questionnaire was a 5-point scale, and an average of 4.2468 after the meta-cognitive learning questionnaire. The correlation coefficient was 0.782 and the significance probability was 0.045. In the case of the Havruta learning correspondence sample statistic, the average of 3.1515 when the preliminary Havruta learning questionnaire was a 5 point scale and the average of the post-Havruta learning questionnaire was 4.3853, which was improved by 1.23 points. The correlation coefficient was 0.631 and the significance probability was 0.049. Meta-cognitive learning and Havruta learning were found to be correlated. The mean of meta cognition was 3.4675 and the mean of Havruta was 3.7684. Metacognitive learning and Havruta learning were -0.042 And there was no statistically significant difference. Therefore, the learning method to improve the job ability should be applied considering the characteristics of the subject.

Assessment of the Caries Detection Ability of Quantitative Light-induced Fluorescence (QLF) in Primary Teeth in vitro (유치의 치아우식증 확인을 위한 정량형광분석(QLF) 검사법의 우식탐지능력 평가)

  • Cho, Kyung Hyun;Kang, Chung-Min;Jung, Hoi-In;Lee, Tae Yang;Song, Je Seon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.49 no.1
    • /
    • pp.65-75
    • /
    • 2022
  • The aim of this study was to evaluate QLF (quantitative light-induced fluorescence) technology for the caries detection in primary teeth and validate the relationships between the cavity volume of carious lesions and QLF analysis results. Total 125 tooth surfaces include 53 occlusal surfaces, and 72 proximal surfaces were investigated with the portable QLF device for detection of dental caries in primary molars. Micro-CT radiograph was also performed to classify carious lesions and calculate the cavity volume. QLF showed good accuracy and reliability (sensitivity 0.75 - 0.94, specificity 0.82 - 0.95, and AUROC 0.88 - 0.98) for the caries detection in primary teeth except 𝚫R average results of proximal caries which showed relatively low values. Statistically significant relationships were found between 𝚫F average, QS-Index and the cavity volume according to Spearman rank-order correlation coefficients (r = 0.805 - 0.832, p < 0.001). QLF detection method would be a harmless and reliable way for children to diagnose dental caries without the concern about radiation exposure.

Legal Issues for the Implementation of Non-Face-to-Face Treatment (비대면진료 실행을 위한 법적 쟁점)

  • Kwon, Ohtak
    • The Korean Society of Law and Medicine
    • /
    • v.23 no.3
    • /
    • pp.47-87
    • /
    • 2022
  • Due to the COVID-19 pandemic, non-face-to-face treatment was temporarily permitted. A lot of consensus has been formed on the need to continuous non-face-to-face treatment. However, the current 「Medical Service Act」 only permits telemedicine between doctors and medical personnel. On the other hand, as a result of legal interpretation, there is an opinion that non-face-to-face treatment is allowed. But considering the overall legal system, non-face-to-face treatment is not allowed. Nevertheless, we have to consider the reality such as the development of science and technology and the outbreak of infectious diseases. Therefore, it is not advisable to allow face-to-face treatment only. Ultimately, it is necessary to find ways to ensure that non-foce-to-face treatment can be performed in a safe and effective manner. And it should be institutionalized. This is strategically necessary and important. Therefore, we must look over ahead legal issues to be discussed. First of all, the scope, the target disease and the subject of implement have to be clear. Also, structurally, the standards of facilities and equipment must be prepared for non-face-to-face treatment to be implemented. Functionally, communication and information exchange between doctors and patients should be well conducted. In addition, the information protection management system that occurs in the process of non-face-to-face treatment should be materialized. Lastly, the issue of responsibility and cost of non-face-to-face treatment should be decided in detail. When these problems materialize, it can be expected that a safe non-face-to-face treatment environment will be established.

How to Evaluate the Combined Dust Removal Efficiency of Fine Dust in the Dust Collector (집진기 미세먼지의 복합제진효율 평가방법)

  • Kang, Il-Seo;Lee, Young-su;Kim, Dong-Hyun
    • Journal of Digital Convergence
    • /
    • v.20 no.2
    • /
    • pp.339-344
    • /
    • 2022
  • It is about how much fine dust can be efficiently removed with respect to the electric dust collector used in factories and large facilities. The results of evaluating the fine dust removal efficiency are as follows. At 10,000 V, Efficiency method I showed 68.1 %, and Efficiency method II was 58.6 %, which was lower than that of Efficiency method I. At 5,000 V, Efficiency method I showed 57.6%, and Efficiency method II showed 51.6%, which was lower than Efficiency method I. At 2,500 V, Efficiency method I showed 50.3%, and Efficiency method II showed 24.4%, which was lower than Efficiency method I. In case of Efficiency method I, it is the efficiency calculated by using the dust concentration before and after passing through the filter. Efficiency method II calculated Efficiency method II to measure the efficiency a little more accurately in the environment where the air after the filter and the polluted air are mixed. Efficiency method II showed lower efficiency than Efficiency method I. As a result of the electrostatic precipitator test, the dust collecting performance was highest at 10,000 V, followed by 5,000 V and 2,500 V in that order.

Microplastics in Processed Food: New Threats to Food Safet (가공식품에서의 미세플라스틱: 새로운 식품안전에 대한 위협)

  • Jihoo Kim;Hyeyoung Lee;Dong-Seob Kim;Chung-Yeol Lee;Heeseob Lee
    • Journal of Life Science
    • /
    • v.33 no.2
    • /
    • pp.216-226
    • /
    • 2023
  • Since nylon 66, a polyamide resin, has been developed and applied to toothbrush bristles, plastic consumption has increased rapidly every year, along with the increase in the amount of plastic discarded. Among the various forms of plastic debris produced by the decomposition of plastics, microplastics with a size of less than 5 mm are widely distributed in the environment, which poses a threat not only to the environment but also to animals and humans. The pathway through which microplastics enter the human body is known as ingestion by water and food, inhalation from air, and skin contact. Microplastics introduced into the human body affect human health. Recently, food-related studies have begun to be reported among microplastics-related studies, and analyses of the presence of microplastics in processed foods, such as canned foods, dried seaweed, beverages, beer, milk, sugar, and honey, are underway. Here, we present trends in the production and consumption of plastics, the generation of microplastics, the route of human inflow and human risk, and the microplastics present in processed foods, which are limited but have recently been reported. Thus far, studies on microplastics and risk assessment in processed foods have been insufficient, but microplastics are gradually being recognized as a factor that affects the environment and food. Future studies are expected to have implications for regulations regarding microplastics present in processed foods.