• Title/Summary/Keyword: Health and performance in lighting

Search Result 18, Processing Time 0.027 seconds

Study on the Flicker Characteristics for Human Centric Lighting (HCL) Application of the LED Lighting used in Indoor Spaces (실내 공간에서 사용하는 LED 조명의 인간 중심 조명(HCL) 적용을 위한 플리커 특성에 대한 연구)

  • Won-Kuk Son;Chung-Hyeok Kim
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.37 no.6
    • /
    • pp.644-648
    • /
    • 2024
  • Human-centric lighting (HCL) aims to enhance well-being and performance by tailoring lighting to human needs. However, LED flicker-rapid brightness changes-remains a critical issue, causing discomfort and reduced productivity. This paper addresses flicker problems in living and industrial spaces with LED lighting. We propose solutions to mitigate flicker by examining causes like power supply variations and LED driver design. Techniques such as high-quality LED drivers, advanced dimming methods, and digital control systems are explored. Our findings show these techniques can significantly reduce flicker, achieving less than 1% flicker performance while meeting HCL's diverse requirements. Implementing flicker-free lighting in residential spaces enhances comfort and reduces eye strain, while in industrial settings, it improves productivity and safety. This paper emphasizes the importance of control circuits that maintain sub-1% flicker performance while integrating various HCL solutions, enhancing indoor lighting quality, and promoting better health and performance.

Comprehensive System Framework for Visual Fatigue and Cognitive Performance Management based on Predictive Models

  • Dahyun JUNG;Hakpyeong KIM;Seunghoon JUNG;Hyuna KANG;Seungkeun YEOM;Juui KIM;Taehoon HONG
    • International conference on construction engineering and project management
    • /
    • 2024.07a
    • /
    • pp.988-995
    • /
    • 2024
  • With the modern workplace's increasing dependence on computer-based tasks, traditional lighting standards have been identified as insufficient for optimal occupant comfort and productivity. Therefore, this paper presents a comprehensive system framework designed to manage visual fatigue and cognitive performance within office environments. Classification and regression models using gradient boosting machine and random forest to predict visual fatigue and cognitive performance were developed based on data collected from 16 subjects in experiments. To this end, the proposed system consists of two modules: the first module predicts visual fatigue and cognitive performance levels using classification models, offering immediate feedback to occupants. The second module, targeted at facility managers, uses regression models and a genetic algorithm to identify optimal lighting settings, aiming to minimize visual fatigue and enhance cognitive performance. This system can help to manage visual fatigue and cognitive performance simultaneously, contributing to improvement of eye health and productivity.

Architectural Implementation for the Daylight-Performance in the Elementary School (초등학교 채광 성능 실태조사에 따른 건축계획적 개선방안에 관한 연구)

  • Lee, Jeong-Cheol;Lim, Hong-Soo;Kim, Gon;Koo, Jae-Oh
    • KIEAE Journal
    • /
    • v.10 no.3
    • /
    • pp.43-50
    • /
    • 2010
  • Natural lighting is directly connected with our mental and physical health. For working or learning effect, the proper natural lighting is required for improving our living conditions. School facilities, especially, are the place where includes students' ordinary activities with learning behaviors during the school years from elementary to high school. This study was carried out for the purpose introducing a basic database in that planning a school by researching on the actual in the natural lighting system of some schools' classroom, estimating, and analyzing through a simulation, which resulted in a method of improving the natural lighting system. As a result of measuring and analyzing Daylight Factor(DF) during the time from 9 am to 3 pm when students are activating in their classroom, generally DF range of the sides near to window and aisle seats zone are not distributed well. Besides, two out of four school which are researched would not reach the standards of the law for school sanitary while rest of the schools meet the standards; Average DF 5% and Minimum DF 2%. And the result of a simulation by RADIANCE program shows the most appropriate DF range when it is applied in variable numbers about an oriehows the- South-east 15, south-east 30, south-east 45, south-west 15, south-west 30, and south-west 45 degrees. When it is applied in the variable numbers about glass transmittance - 60%, 70%, and 80% in condition facing south of a classroom, the result shows that the DF range of 80% transmittance is relatively higher than other glasses in the classroom. Thus, when a school is built, plans for an orientation is necessary for improve of elementary schools' environment with the glass installation which is made for high transmittance and is regarded with the students' activities time.

Effect of night light regimen on growth performance, antioxidant status and health of broiler chickens from 1 to 21 days of age

  • Zhao, R.X.;Cai, C.H.;Wang, P.;Zheng, L.;Wang, J.S.;Li, K.X.;Liu, W.;Guo, X.Y.;Zhan, X.A.;Wang, K.Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.32 no.6
    • /
    • pp.904-911
    • /
    • 2019
  • Objective: The study was conducted to evaluate the effects of night light regimen on growth performance, antioxidant status and health of Lingnan Yellow broiler chickens from 1 to 21 days of age. Methods: A completely randomized factorial design involved 2 photoperiods (constant lighting [CL], 24 L:0 D and intermittent lighting [INL], 17 L:3 D:1 L:3 D)${\times}2$ light intensities (10 lx and 30 lx). A total of one thousand six hundred and eighty 1-d-old Lingnan Yellow broiler chicks were randomly divided into 4 treatments with 6 replicates (70 birds per replicate). The experiment lasted for 21 d. Results: Photoperiods and light intensities had no effect on average daily gain, feed conversion ratio, and mortality of the broiler chickens (p>0.05). The INL had a significant effect on average daily feed intake (p<0.05) of broiler chickens compared with CL. Photoperiod and light intensity had an interactive effect on melatonin (MT) concentration (p<0.05). At CL, reducing light intensity increased MT concentration; INL birds had higher MT but MT concentration was not affected by light intensity. There was an interactive effect on glutathione peroxidase (GPx) and catalase (CAT) in serum and total antioxidant capability (T-AOC) in liver between photoperiod and light intensity. With the decrease of light intensity, the activities of GPx and CAT in serum and T-AOC in liver increased in CL group (p<0.05). Broiler chickens reared under INL had better antioxidant status and 10 lx treatments had higher activities of CAT in serum than 30 lx (p<0.05). Different photoperiods and light intensities had no effect on malondialdehyde. There was an interaction between photoperiod and light intensity on serum creatine kinase (CK) concentration (p<0.05). At CL, the elevated light intensity resulted in an increase in CK content; INL birds had lower CK concentration especially in low light intensity group. Besides, INL and low light intensity significantly reduced the concentration of serum corticosterone and heat shock protein 70 (p<0.05). Serum immunoglobulin M contents were increased in broiler chickens reared under the INL compared with CL group (p<0.05). Conclusion: Results above suggest that the night light regimen of INL and 10 lx could be beneficial to the broiler chickens from 1 to 21 days of age due to the better health status and electricity savings.

A Study on Indoor Environmental Quality Evaluation in Apartment Buildings - Focus on Apartment Buildings in USA - (공동주택에서의 실내환경의 질 평가에 관한 연구 - 미국 공동주택 사례를 중심으로 -)

  • Yoon, Sung-Hoon
    • Korean Institute of Interior Design Journal
    • /
    • v.18 no.4
    • /
    • pp.79-87
    • /
    • 2009
  • Residential Buildings should provide high-quality, comfortable environments to support the activities of their occupants. The indoor environment of residential buildings, which includes thermal, lighting, acoustic, and indoor air quality, has a significant impact on health and quality of life. The comfortable living environment in residential buildings result from appropriately combining these environmental quality factors, and the performance of building systems must be compatible with the activities of the occupants. The objective of this research is to investigate and analyze the relationship between physical environmental conditions and occupant responses for improving environmental quality (EQ) in apartment buildings with four different building orientations (i.e. E, W, S, N) in two different seasons (i.e. winter and summer). The occupant survey was conducted in actual apartment buildings. The Physical environmental conditions in apartment buildings differed substantially depending on space, outdoor weather conditions and building orientations. Each space within the same apartment building had different environmental conditions. Combinations of unbalanced physical environmental conditions in apartment building decrease occupants' satisfactions and their perceptions of overall residential quality. Occupants' satisfaction and their responses to physical characteristics of their residential environment is related to thermal, lighting, acoustic, and indoor air conditions in their buildings. The result from this research will help designers and researchers to identify problems and develop solutions for improving environmental quality from the occupants' point of view.

A study on light pipe system technology and its application (광파이프 시스템의 조명기술 및 건축적 활용 연구)

  • Shin, Ju Young;Gon, Kim;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.9 no.1
    • /
    • pp.69-76
    • /
    • 2009
  • The use of natural light can improve the quality of indoor environment and also occupants health. In recent years, with an increasing awareness of sustainable development, various innovative methods of integrating daylight into the building have been developed. One such device is the light pipe system. The light pipes are innovative daylighting system that allow the transmission of daylight into the hard-to-reach indoor space. The system consist of mainly three parts. First, a top collector which is mounted on the outside of the roof and gathers skylight and sunlight. Second, light-reflective tube which is coated with highly reflective mirror finish material to transmit the daylight into the diffuser. Third, a diffuser which is installed on the ceiling in the room and spread the daylight into the room. Light pipes have been widely used and researched in many countries such as Australia, America, Canada and Britain. However, despite the significant daylight potential, little work have been carried out in Korea compare to the other countries. In this study, recent lighting technology and application of light pipe system in both Korea and other countries have been compared. For the results, the benefits of each light pipe system and suitable application in Korea is also discussed.

A Study on the Operator Performance According to the Drastic Change of Illumination Level and Lighting Environment of Control Room in Nuclear Power Plants

  • Shin, Kwang Hyeon;Lee, Yong Hee
    • Journal of the Ergonomics Society of Korea
    • /
    • v.32 no.1
    • /
    • pp.37-45
    • /
    • 2013
  • Objective: This study describes the change of operator performance in drastic change of illumination level, and proposes an alternative method to cope with it. Background: The control standard of illumination for nuclear power plants(NPPs) is based on the set of limit criteria for maintaining a specific illumination level. However, there is a possibility to cause human errors according to the psychological and physiological influences to operators in the situation of drastic change of illumination such as SBO(Station Black Out), so a basic study is necessary to review the current approach. Method: We assessed the visual fatigue, subjective work load and task performance according to the three illumination situations(Normal Illumination, Emergency Illumination, and Drastic Change of Illumination). Result: Research finding shows that there are not significant differences in task performance between normal illumination (1,000lx level) and emergency illumination (100lx level), only if beyond the dark adaptation limit. However, subjective work load on mental demand and visual fatigue show a potential challenge to visual performance in drastic change of illumination. Conclusion/Application: Several trials can complement this challenge in NPPs by applying 3-way communication, enhancing readability of procedures, and managing the visual factors affecting the operators' performance through a Visual Environment Management Program including visual health aspects, etc.

Checklist and Design Recommendations for the Interiors of Korean, Eco-healthy Childcare Facilities (우리나라 영유아 보육시설의 친환경 실내를 위한 체크리스트와 디자인안 제안)

  • Chun, Jin Hie
    • KIEAE Journal
    • /
    • v.10 no.6
    • /
    • pp.105-114
    • /
    • 2010
  • As children are known to touch and chew everything, green cleaning procedures are an important step in preventing children from ingesting harmful toxins. The objectives of this study are to develop a new, self-evaluation checklist and to suggest design recommendations which comply with easy, adaptable, economical ways to improve the eco-friendly indoor environment of Korean childcare facilities. The information compiled during this study was collected through literature review and internet surveys1) from July, 2009 to February, 2010. The results of this study show that the current Korean childcare accreditation system and practices emphasize clean building interiors, policies for sanitation and cleanliness, and control of humidity and lighting. On the other hand, the information provided by green-building rating systems from GBCC, LEED, and GBTool offers additional and comparative details regarding indoor environment quality and standards regarding the IAQ performance and management plan, ventilation and thermal comfort systems, views from windows, acoustics, and lighting. In conclusion, this document provides an appropriate and easy-to-follow, self-evaluation checklist composed of eight criteria and 51 practical items. This study also provides the design recommendations composed of 27 practical ideas focusing on interior elements. Both the checklist and design recommendations I have suggested can be a post-occupancy tool for evaluating eco-healthy facility standards as well as tips for continuing to maintain eco-healthy childcare facilities.

Study on Comparative Analysis of Daylight Evaluation Tools for Building Environment (건물 주광환경 평가도구의 비교분석에 관한 연구)

  • Park, K.E.;Kim, J.T.
    • Journal of the Korean Solar Energy Society
    • /
    • v.22 no.4
    • /
    • pp.26-34
    • /
    • 2002
  • Daylighting in building is very important as it has an effect on work performance as well as on their visual health. It is also regarded as a good energy conservation measure in saving energy used for lighting. There are many daylighting evaluation tools such as empirical equations, tables, nomograms, diagrams, protractors, computer simulation, scale models. This study conducted initial daylight measurements to analyze luminous environment in classrooms of elementary school and comparative analysis on three daylighting evaluation tools, such as daylight factor calculation formula, the graphic method with BRE Protractor and computer simulation with Adeline 3.0. It is found that the computer simulation tool produced the closest result to actual measurements of luminous environment in elementary school classroom, and the other simplified tools made appropriate results so that they can be used in the early stage of daylighting design process.

A Study on the Experiment of Luminous Environment in Classroom of An Elementary School (초등학교 교실의 빛 환경 실측에 관한 연구)

  • Park, Kyung-Eun;Kim, Jun-Tae
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.9 no.5
    • /
    • pp.13-21
    • /
    • 2002
  • Daylighting in educational environment is very important as it has an effect on students' performance as well as in their visual health. It is regarded as a good energy conservation method in saving energy used for lighting. This study conducted initial daylight measurements to analyze luminous environment in classrooms of Korean elementary school. The results indicated that the typical classroom had a reasonable level of daylight. However, it also found that the classroom had some problems of the uniformity of illuminance and the contrast of brightness of surfaces in the classroom. It is argued that daylighting design for school classroom should consider these aspects to make daylit classrooms ideal so as to provide comfortable visual environment.