• Title/Summary/Keyword: Health Measurement

Search Result 3,541, Processing Time 0.03 seconds

Intra and Inter-Rater Measurement Reliability of Tibialis Anterior Muscle (TA) Thickness using the Ultrasonography Spring Gauge Technique

  • Hwang, Byeong-Hun;Jang, Tae-Jin;Jeon, In-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • v.33 no.4
    • /
    • pp.187-192
    • /
    • 2021
  • Purpose: The purpose of the current study was to determine the intra- and inter-rater reliability of muscle thickness measurement of the TA using ultrasonography (US) conducted at different inward pressures of approximately 0.5 kg, 1.0 kg, and no pressure control. Methods: Twenty healthy subjects were recruited for this study. Two different examiners measured the thicknesses of the dominant TA of each subject randomly to assess the intra- and inter-rater reliability. The measurement values were analyzed using the intra-class correlation coefficient (ICC) with a 95% confidence interval, standard error of measurement, minimal detectable change, and coefficient of variance. Results: All intra-rater reliability ICC values showed high reliability above 0.9. Inter-rater reliability ICC values showed high reliability above 0.9 with 0.5 and 1.0 kg of inward pressure. In contrast, Inter-rater reliability ICC values showed poor reliability (0.23) with no pressure control of inward pressure. Conclusion: The findings showed that maintaining consistent inward pressure is essential for reliable results when the muscle thickness of the TA is measured by different examiners in a clinical setting.

Introducing an Online Measurement System Using Item Response Theory and Computer Adaptive Testing Methods for Measuring the Physical Activity of Community-Dwelling Frail Older Adults

  • Choi, Bong-sam
    • Physical Therapy Korea
    • /
    • v.26 no.3
    • /
    • pp.106-114
    • /
    • 2019
  • Background: It is difficult to assess whether community-dwelling frail older adults may remain pre-frail status or improve into a robust state without being directly checked by health care professionals. The health information perceived by older adults is considered to be one of best sources of potential concerns in older adult population. An online measurement system combined with item response theory (IRT) and computer adaptive testing (CAT) methods is likely to become a realistic approach to remotely monitor physical activity status of frail older adults. Objects: This article suggests an approach to provide a precise and efficient means of measuring physical activity levels of community-dwelling frail older adults. Methods: Article reviews were reviewed and summarized. Results: In comparison to the classical test theory (CTT), the IRT method is empirically aimed to focus on the psychometric properties of individual test items in lieu of the test as a whole. These properties allow creating a large item pool that can capture the broad range of physical activity levels. The CAT method administers test items by an algorithm that select items matched to the physical activity levels of the older adults. Conclusion: An online measurement system combined with these two methods would allow adequate physical activity measurement that may be useful to remotely monitor the activity level of community-dwelling frail older adults.

Development and Validation of the Hospital's CSR Measurement Tool (의료기관 사회적 책임활동 측정 도구개발 및 타당화)

  • Cho, Kyoung Won;Sagong, Mi;Cho, Minje
    • The Korean Journal of Health Service Management
    • /
    • v.12 no.2
    • /
    • pp.149-162
    • /
    • 2018
  • Objectives : This study aimed to develop tools to measure the social responsibility activities of hospitals using ISO 26000 and to verify the validity and reliability of the developed tools. We verified the content and structural validity, as well as the internal consistency of the proposed measurement tool for hospitals' social responsibility. Methods : We conducted an online survey on hospitals/employees from Feb 26 to Mar 12, 2018, and analyzed selected 197 respondents from the survey by removing incomplete responses. Results : The developed hospitals' CSR (HSR) measurement tool consists of 36 items with 5 factors: "consumer issues", "labor practices", "community involvement & development", "fair operating practice", and "environment". Analysis revealed high reliability with Cronbach' alpha of 0.981. Conclusions : It was verified that the developed HSR tool fully reflected hospital characteristics. This tool can be used to diagnose hospitals' social responsibility and to support strategic decision on social responsibility.

Simultaneous active strain and ultrasonic measurement using fiber acoustic wave piezoelectric transducers

  • Lee, J.R.;Park, C.Y.;Kong, C.W.
    • Smart Structures and Systems
    • /
    • v.11 no.2
    • /
    • pp.185-197
    • /
    • 2013
  • We developed a simultaneous strain measurement and damage detection technique using a pair of surface-mounted piezoelectric transducers and a fiber connecting them. This is a novel sensor configuration of the fiber acoustic wave (FAW) piezoelectric transducer. In this study, lead-zirconate-titanate (PZT) transducers are installed conventionally on a plate's surface, which is a technique used in many structural health monitoring studies. However, our PZTs are also connected with an optical fiber. A FAW and Lamb wave are simultaneously guided in the optical fiber and the structure, respectively. The dependency of the time-of-flight of the FAW on the applied strain is quantified for strain sensing. In our experimental results, the FAW exhibited excellent linear behavior and no hysteresis with respect to the change in strain. On the other hand, the well-known damage detection function of the surface-mounted PZT transducers was still available by monitoring the waveform change in the conventional Lamb wave ultrasonic path.

Development of Portable Bio-signal Measurement System using Bluetooth for 24-hours Continuous Health Monitoring (24시간 건강상태 모니터링을 위한 Bluethooth를 사용한 소형 저전력 휴대형 Bio-signal 측정 장치를 개발)

  • 정현권;송길섭;나승유;이희영
    • Proceedings of the IEEK Conference
    • /
    • 2001.06e
    • /
    • pp.81-84
    • /
    • 2001
  • This paper presents a potable bio-signal measurement system using Bluetooth for the 24-hours continuous health state monitoring of the elderly and the disabled. The measurement system has the functions of acquisition of various bio-signals, wireless data transmission and adjustment of parameters such as gain and cut-off frequency. This measurement system is designed according to the international specifications of the recommendation of AAMI (Association for the Advancement of Medical Instrumentation). The design targets of the developing system about volume and power consumption are 20x30x5mm$^3$ and 8mW.

  • PDF

A Study on the Standardization In the Mandibular First Premolar of the Middle Aged Korean (하악 제1소구치의 표준화 연구)

  • Lee H.J.;Chun K.J.;Chung D.T.;Cho C.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.252-255
    • /
    • 2005
  • Mandibular first premolars obtained from the middle-aged men about the ages of 50 were scanned using a Micro-CT. A Jig was made for a Micro-CT measurement to get reliable data from irregular teeth shape. Data were measured from the scanned 2-D images by way of measurement software. the methodology fer measurement of the mandibular first premolar was presented and according to this, the standardized mandibular first premolars of middle aged Korean males and females were made by using a rapid prototyping system.

  • PDF

The Health-related Quality of Life of Obesity (비만과 건강관련 삶의 질)

  • Kwon, Young-Dal
    • Journal of Korean Medicine for Obesity Research
    • /
    • v.4 no.1
    • /
    • pp.125-137
    • /
    • 2004
  • Objective: The purpose of this study is to investigate how to use the Quality of Life(QoL) of obesity and to study the report cases which measure QoL on obesity. Method: This study investigate the definition of Health-related Quality of Life(HRQoL), the measurement of Health-related Quality of Life, and the papers of Health-related Quality of Life on obesity through the books and medicine journals of HRQoL and obesity. Conclusions: 1. The QoL includes role functional ability, the degree and quality of social and community interaction, psychological state, somatic feeling, and life satisfaction than personal health and social well-being. 2. The investigator needs to evaluate the reliability, validity and sensitivity of the scale, and the appropriateness of the instrument for the target population When he decides measurement. 3. The investigator have the well-drilled supporter or himself managed the data and study population to prevent missing data. 4. The investigator should decide which is needed on obesity a obesity-specific or broad-ranging instrument, or both.

  • PDF

Suggestions to improve occupational hygiene activities based on the health problems of semiconductor workers (반도체 근로자 질병의 직무관련 논란으로 본 우리나라 산업위생 활동 개선방향)

  • Park, Donguk;Yoon, Chungsik
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.22 no.1
    • /
    • pp.1-8
    • /
    • 2012
  • Objectives: The aim of this study is to review occupational hygiene activities, including work environment measurement as required by the industrial safety and health laws of Korea, and suggest improvements required to establish an effective exposure surveillance system. Methods: The controversial limitations of exposure surveillance examining the work-association of several types of cancers in semiconductor workers were reviewed. Results: The bulk of the exposure surveillance system was found to focus purely on work environment measurements without providing other important exposure surrogates, such as job title, operation, exposure duration, etc. The current work environment measurement system is limited in terms of the efficient assessment of the exposure status of workers due to a lack of exposure information. Conclusion: The introduction of a national standard classification of occupations and job titles into the exposure and health effect surveillance system should be discussed in order to retrospectively assess exposure characteristics.

Fundamental Study of Relative Measurement for Accurate Measurement of Stent Size in Computed Tomography Angiography (컴퓨터단층 혈관조영술에서 스텐트 사이즈의 정확한 측정을 위한 상대적 측정법의 기초연구)

  • Lee, Seung-Young;Hong, Joo-Wan;Kang, Su-Mi;Kim, Su-Bin;Joon, Sang-Hoon;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.713-720
    • /
    • 2019
  • The purpose of this study was to propose a new measurement method for accurate measurement of vessel diameter in computed tomography angiography(CTA). CTA test was performed after non-ionic iodine contrast agent was flowed at a constant rate to self-maded perfusion phantom. After obtaining raw data, images were reconstructed with multi-planar reconstruction(MPR) and maximal intensity projection(MIP). Diameters of vascular models were measured for each technique. Relative and conventional measurements were then compared. The mean diameter of the vascular model was closer to the actual measurement when relative measurement was used compared to that when conventional measurement was used both in MPR and MIP. Relative measurements of MPR and MIP were closer to actual measurement than those of conventional measurement (34% VS, 24%, p<0.05). The relative measurement method proposed in this study was closer to the actual measurement than the conventional measurement method. However, both test methods were still larger than actual results. Therefore, further study of relative measurement method is needed using this study as basic data.

A basic research for evaluation of a Home Care Nursing Delivery System (가정간호 서비스 질 평가를 위한 도구개발연구)

  • Kim, Mo-Im;Cho, Won-Jung;Kim, Eui-Sook;Kim, Sung-Kyu;Chang, Soon-Bok;Ryu, Ho-Sihn
    • Journal of Home Health Care Nursing
    • /
    • v.6
    • /
    • pp.33-45
    • /
    • 1999
  • The purpose of this study was to develop a basic framework and criteria for evaluation of quality care provided to patients with the attributes of disease in the home care nursing field, and to provide measurement tools for home health care in the future. The study design was a developmental study for evaluation of hospital-based HCN(home care nursing) in Korea. The study process was as follows: a home care nursing study team of College of Nursing. Yonsei University reviewed the nursing records of 47 patients who were enrolled at Yonsei University Medical Center Home Care Center in March, 1995. Twenty-five patients were insured at that time, were selected from 47 patients receiving home care service for study feasibility with six disease groups; Caesarean Section (C/S), simple nephrectomy, Liver cirrhosis(LC), chronic obstructive pulmonary disease(COPD), Lung cancer or cerebrovascular accident(CVA). In this study, the following items were selected : First step : Preliminary study 1. Criteria and items were selected on the basis of related literature on each disease area. 2. Items were identified by home care nurses. 3. A physician in charge reviewed the criteria and content of selected items. 4. Items were revised through preliminary study offered to both HCN patients and discharged patients from the home care center. Second step : Pretest 1. To verify the content of the items, a pretest was conducted with 18 patients of which there were three patients in each of the six selected disease groups. Third step : Test of reliability and validity of tools 1. Using the collected data from 25 patients with either cis, Simple nephrectomy, LC, COPD, Lung cancer, or CVA. the final items were revised through a panel discussion among experts in medical care who were researchers, doctors, or nurses. 2. Reliability and validity of the completed tool were verified with both inpatients and HCN patients in each of field for researches. The study results are as follows: 1. Standard for discharge with HCN referral The referral standard for home care, which included criteria for discharge with HCN referral and criteria leaving the hospital were established. These were developed through content analysis from the results of an open-ended questionnaire to related doctors concerning characteristic for discharge with HCN referral for each of the disease groups. The final criteria was decided by discussion among the researchers. 2. Instrument for measurement of health statusPatient health status was measured pre and post home care by direct observation and interview with an open-ended questionnaire which consisted of 61 items based on Gorden's nursing diagnosis classification. These included seven items on health knowledge and health management, eight items on nutrition and metabolism, three items on elimination, five items on activity and exercise, seven items on perception and cognition, three items on sleep and rest, three items on self-perception, three items on role and interpersonal relations, five items on sexuality and reproduction, five items on coping and stress, four items on value and religion, three items on family. and three items on facilities and environment. 3. Instrument for measurement of self-care The instrument for self-care measurement was classified with scales according to the attributes of the disease. Each scale measured understanding level and practice level by a Yes or No scale. Understanding level was measured by interview but practice level was measured by both observation and interview. Items for self-care measurement included 14 for patients with a CVA, five for women who had a cis, ten for patients with lung cancer, 12 for patients with COPD, five for patients with a simple nephrectomy, and 11 for patients with LC. 4. Record for follow-up management This included (1) OPD visit sheet, (2) ER visit form, (3) complications problem form, (4) readmission sheet. and (5) visit note for others medical centers which included visit date, reason for visit, patient name, caregivers, sex, age, time and cost required for visit, and traffic expenses, that is, there were open-end items that investigated OPD visits, emergency room visits, the problem and solution of complications, readmissions and visits to other medical institution to measure health problems and expenditures during the follow up period. 5. Instrument to measure patients satisfaction The satisfaction measurement instrument by Reisseer(1975) was referred to for the development of a tool to measure patient home care satisfaction. The instrument was an open-ended questionnaire which consisted of 11 domains; treatment, nursing care, information, time consumption, accessibility, rapidity, treatment skill, service relevance, attitude, satisfaction factors, dissatisfaction factors, overall satisfaction about nursing care, and others. In conclusion, Five evaluation instruments were developed for home care nursing. These were (1)standard for discharge with HCN referral. (2)instrument for measurement of health status, (3)instrument for measurement of self-care. (4)record for follow-up management, and (5)instrument to measure patient satisfaction. Also, the five instruments can be used to evaluate the effectiveness of the service to assure quality. Further research is needed to increase the reliability and validity of instrument through a community-based HCN evaluation.

  • PDF