• 제목/요약/키워드: Headspace solid-phase micro extraction

검색결과 10건 처리시간 0.018초

Integration of Headspace Solid Phase Micro-Extraction with Gas Chromatography for Quantitative Analysis of Formaldehyde

  • Lo, Kong Mun;Yung, Yen Li
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권1호
    • /
    • pp.139-142
    • /
    • 2013
  • A study was carried out to evaluate the solid phase micro-extraction (SPME) for formaldehyde emission analysis of uncoated plywood. In SPME, formaldehyde was on-fiber derivatized through headspace extraction and analyzed by gas chromatography coupled with mass spectrometry (GC/MS). The SPME was compared with desiccators (DC-JAS 233), small-scale chamber (SSC-ASTM D6007) and liquid-liquid extraction (LLE-EPA 556) methods which were performed in accordance with their respective standards. Compared to SSC (RSD 4.3%) and LLE (RSD 5.0%), the SPME method showed better repeatability (RSD 1.8%) and not much difference from DC (RSD 1.4%). The SPME has proven to be highly precise (at 95% confidence level) with better recovery (REC 102%). Validation of the SPME method for formaldehyde quantitative analysis was evidenced. In addition, the SPME by air sampling directly from plywood specimens (SPME-W) correlated best with DC ($r^2$ = 0.983), followed by LLE ($r^2$ = 0.950) and SSC ($r^2$ = 0.935).

Analysis of Flavor Composition of Coriander Seeds by Headspace Mulberry Paper Bag Micro-Solid Phase Extraction

  • Cha, Eun-Ju;Won, Mi-Mi;Lee, Dong-Sun
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권11호
    • /
    • pp.2675-2679
    • /
    • 2009
  • This paper reports the example of headspace mulberry paper bag micro solid phase extraction (HS-MPB-$\mu$-SPE) as a new sampling method for the determination of volatile flavor composition of coriander seeds. Adsorption efficiencies between two configurations of mulberry paper bag were compared, and several parameters affecting the HS-MPB-$\mu$-SPE were investigated and optimized. The optimized technique uses an adsorbent (Tenax TA, 0.1 mg) contained in a mulberry paper bag of front configuration where fine surface was outside, and minimal amount of organic solvent (0.6 mL). Linalool and $\gamma$-terpinene were found as abundant flavor compounds from coriander seeds. The limit of detection (LOD) and the limit of quantitation (LOQ) for linalool of major flavor in coriander seeds were 10.3 ng/mL and 34.4 ng/mL, respectively. The proposed method showed good reproducibility and good recovery. The HS-MPB-$\mu$-SPE is very simple to use, inexpensive, requires small sample amounts and solvent consumption. Because the solvent for extraction is reduced to only a very small volume, there is minimal waste or exposure to toxic organic solvent and no further concentration step.

Measurement of Aldehydes in Replacement Liquids of Electronic Cigarettes by Headspace Gas Chromatography-mass Spectrometry

  • Lim, Hyun-Hee;Shin, Ho-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권9호
    • /
    • pp.2691-2696
    • /
    • 2013
  • The electronic cigarette (E-cigarette) is a battery-powered device that aerosolizes nicotine so that it is readily delivered into the respiratory tract. The analytical data regarding the substances present in E-cigarettes are very limited. The aim of this study was to measure the concentration of aldehydes-formaldehyde (FA), acetaldehyde (AA) and, acrolein (AL)-in 225 replacement liquid brands from 17 E-cigarette shops sold in the Republic of Korea by headspace solid-phase micro extraction and gas chromatography-mass spectrometry (HS-SPME GC-MS). The concentration range of FA and AA was 0.02-10.09 mg/L (mean = 2.16 mg/L, detected in 207 of 225 samples) and 0.10-15.63 mg/L (mean = 4.98 mg/L, detected in all samples), respectively. AL was not detected in any of 225 replacement liquids. FA and AA were originally present in almost all replacement liquids of electronic cigarettes.

Mulberry Paper Bag μ-Solid Phase Extraction for the Analysis of Five Spice Flavors by Gas Chromatography-Mass Spectrometry

  • Yoon, Ok-Kyung;Lee, Dong-Sun
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권1호
    • /
    • pp.35-42
    • /
    • 2009
  • Headspace micro solid phase extraction using mulberry paper bag (HS-MPB-$\mu$-SPE) has been developed and validated for the analysis of volatile flavor compounds from five spice by gas chromatography-mass spectrometry (GC/MS). HS-MPB-$\mu$-SPE was performed with adsorbent particles enclosed inside a mulberry paper bag. Four different kinds of adsorbents such as Tenax TA, Porapack Q, dimethylpolysiloxane and polyethylene glycol were tested. The extraction solvents compared were petroleum ether, methylene chloride, and chloroform. Better results were obtained when Tenax TA and petroleum ether were used. The limit of detection (LOD) and the limit of quantitation (LOQ) were in the range of 1.3 ng/mL and 4.3 ng/mL, respectively, for o-cymene as a model compound of monoterpene. Proposed method showed good reproducibility (3.3%, RSD) and good recoveries (94.0%). The HS-MPB- μ-SPE is very simple to use, inexpensive, rapid, requires small sample amounts and solvent consumption. Because the solvent for extraction is reduced to only a very small volume (0.6 mL), there is minimal waste or exposure to toxic organic solvent and no further concentration step. This method allows successful characterization of the headspace in contact with the five spice sample. Strong trans-anethole from star anise or fennel is a characteristic flavor of five spice powders. HS-MPB-$\mu$-SPE combined with GC/MS can be a promising technique for the broad spectrum measurement of volatile aroma compounds from solid spices.

Optimization of Headspace Sampling Using Solid Phase Microextraction For Volatile Organic Acids in Different Tobacco Types

  • Lee, Jang-Mi;Lee, Jeong-Min;Son, Seong-Ae;Kwon, Young-Ju;Jang, Gi-Chui;Kim, Young-Ho
    • 한국연초학회지
    • /
    • 제35권1호
    • /
    • pp.7-12
    • /
    • 2013
  • A Solid-phase micro extraction(SPME) was evaluated as a tool for headspace sampling of tobacco samples. Several experimental parameters (sampling temperature, pH, and type of SPME fibers) were optimized to improve sampling efficiency in two aspects ; maximum adsorption and selective adsorption of volatile organic acids onto SPME fibers. Among four types of SPME fibers such as PDMS(Polydimethylsiloxane), PA(Polyacrylate), Car/PDMS (Carboxen/Polydimethylsiioxane) and PDMS/DVB(Polydimethylsiioxane/Divinylbenzene) which were investigated to determine the selectivity and adsorption efficiency. A variety of tobacco samples such as flue cured, burley and oriental were used in this study. The effect of these parameters was often dominated by the physical and chemical nature (volatility, polarity) of target compounds. This method allowed us to make important improvements in selectivity and sensitivity. The Car/PDMS fiber was shown to be the most efficient at extracting the 10 selected volatile organic acids. The parameters were optimized: $80^{\circ}C$ adsorption temperature, 30 min of adsorption time, $240^{\circ}C$ desorption temperature, 1 min of adsorption time.

Comparative Study of Extracting Fragrance Allergens by GC-MS/MS

  • Lee, In Ja;Ahn, Jae-Chan;Kim, Bogsoon;Chung, Deukmo
    • Mass Spectrometry Letters
    • /
    • 제8권1호
    • /
    • pp.18-22
    • /
    • 2017
  • Products containing any one or more of 26 fragrance allergens likely to cause contact allergies, are required under the 2008 domestic cosmetic law to be labeled when their concentrations exceed a certain range. This study focuses on the comparison and development of analytical methods based on headspace-solid phase micro extraction (HS-SPME) and liquid-liquid extraction (LLE) methods followed by GC-MS/MS for 24 of the fragrance allergens excepting for two natural materials in water samples. Using the developed HS-SPME method, 15 of the 24 fragrance allergens were analyzed and 9 compounds which have relatively low $logK_{OW}$ values (below about 2.5) were not extracted, and the correlation coefficient ($r^2$) of the calibration curve for quantification showed linearity of 0.9969 or more, and the method detection limits (MDL) and the limits of quantification (LOQ) were $0.078{\sim}0.582{\mu}g/L$ and $0.261{\sim}1.940{\mu}g/L$, respectively. In the case of using the optimized LLE method, all 24 fragrance allergens were analyzed, and the correlation coefficient ($r^2$) of the calibration curve for quantification showed linearity of 0.9957 or more, MDL and LOQ were $0.020{\sim}0.138{\mu}g/L$ and $0.065{\sim}0.440{\mu}g/L$, respectively.

HS-SPME-GC/MS에 의한 지표수에서 ng/L 농도 수준의 37개 휘발성유기화합물의 동시 분석 (Simultaneous determination of 37 volatile organic compounds at ng/L concentration level in surface water by HS-SPME-GC/MS)

  • 김태승;홍석영;김종은;임현희;신호상
    • 분석과학
    • /
    • 제25권1호
    • /
    • pp.39-49
    • /
    • 2012
  • HS-SPME GC-MS에 의한 지표수 중에 37개 휘발성유기물질을 동시에 분석하는 방법을 개발하였다. 이 방법은 물 중 휘발성유기물질을 헤드스페이스 vial에서 $40 ^{\circ}C$에서 30분간 가열 85 ${\mu}m$ carboxen-polydimethylsiloxane에 흡착시키는 방법이다. 4.0 mL의 물 시료를 사용하여 확립한 조건하에서 정량한계는 4.1-96 ng/L의 범위를 나타냈고 이러한 검출한계는 US EPA 또는 독일에서 확립한 준거치의 1/10 이하 값을 만족시켰으며 0.05 ${\mu}g/L$와 0.50 ${\mu}g/L$의 농도에서 정밀도는 15% 이내를 보였다. 이 정량한계는 준거치를 결정하기 위한 조사연구에서 요구하는 최소 감도이다. 확립한 방법을 사용하여 금강물 16개 시료를 분석한 결과 16개 휘발성유기화합물이 검출되었으며 측정값은 US EPA 또는 독일에서 확립한 준거치 이하의 값을 보였다.

Development of Analytical Technology Using the HS-SPME-GC/FID for Monitoring Aromatic Solvents in Urine

  • Lee, Mi-Young;Chung, Yun Kyung;Shin, Kyong-Sok
    • Mass Spectrometry Letters
    • /
    • 제4권1호
    • /
    • pp.18-20
    • /
    • 2013
  • Headspace solid phase micro-extraction gas chromatography/flame ionization detection (HS-SPME-GC/FID) method was compared with headspace gas chromatography/mass selective detection (HS-GC/MS). Organic solvent-spiked urine as well as urine samples from workspace was analyzed under optimal condition of each method. Detection limit of each compound by HS-SPME-GC/FID was $3.4-9.5{\mu}g/L$, which enabled trace analysis of organic solvents in urine. Linear range of each organic solvent was $10-400{\mu}g/L$, with fair correlation coefficient between 0.992 and 0.999. The detection sensitivity was 4 times better than HS-GC/MS in selected ion monitoring (SIM) mode. Accuracy and precision was confirmed using commercial reference material, with accuracy around 90% and precision less than 4.6% of coefficient of variance. Among 48 urine samples from workplace, toluene was detected from 45 samples in the range of $20-324{\mu}g/L$, but no other solvents were found. As a method for trace analysis, SPME HS GC/FID showed high sensitivity for biological monitoring of organic solvent in urine.

Discrimination of Ginseng Habitat by Using Instrumental Analysis Techniques

  • Sohn H. J.;Lee S. K.;Cho B. G.;Kim S. J.;Lee N. Y.;Choi D. S.;Jeong M. S.;Bae H. R.;Yang J. W.
    • 고려인삼학회:학술대회논문집
    • /
    • 고려인삼학회 2002년도 학술대회지
    • /
    • pp.238-252
    • /
    • 2002
  • In order to screen out indicators for the discrimination of ginseng habitat, some physical and chemical characteristics of Korean red ginsengs (94 kinds) and Chinese red ginsengs (50 kinds) were analyzed by using a rheometer, an electronic nose system, a combined technique of solid phase micro-extraction (SPME) and gas chromatograph equipped with an electron capture detector (GC/ECD), an X-ray fluorescence spectrometer (XRF), an inductively coupled plasma mass spectrometer (ICP/MS), a near infrared spectrometer (NIRs) and high performance liquid chromatography equipped with evaporative light scattering detector (HPLC/ELSD). The results are summarized as follows: (i) The rhizome strengths of Korean red ginsengs were significantly higher than those of Chinese red ginsengs. (ii) The electronic nose patterns of Korean red ginsengs were significantly different from those of Chinese red ginsengs. (iii) Some unidentified peaks were detected not in the headspace of Korean red ginsengs but in the headspace of Chinese red ginsengs when the headspace volatiles prepared by the SPME technique were analyzed by GC/ECD. (iv) Either the content ratios of K to Ca or Mn to Fe were significantly different between Korean red ginsengs and Chinese red ginsengs. (v) The reflectance ratios of NIRs wavenumbers such as $904\;cm^{-1}\;to\;1088\;cm^{-1}$ for Korean red ginsengs were significantly different from those for Chinese red ginsengs. (vi) The content ratios of ginsenoside-Rg to ginsenoside-Re of Korean red ginsengs were significantly higher than those of Chinese red ginsengs. These results indicate that the rhizome strength, the electronic nose pattern, the occurrence of ECD-sensitive headspace volatile components, the content ratios of K to Ca and Mn to Fe, the NIRs pattern and the content ratio of ginsenoside-Rg to -Re may be indicators for the discrimination of ginseng habitat.

  • PDF

Functional Characterization of khadi Yeasts Isolates for Selection of Starter Cultures

  • Motlhanka, Koketso;Lebani, Kebaneilwe;Garcia-Aloy, Mar;Zhou, Nerve
    • Journal of Microbiology and Biotechnology
    • /
    • 제32권3호
    • /
    • pp.307-316
    • /
    • 2022
  • Yeasts play an important role in spontaneous fermentation of traditional alcoholic beverages. Our previous study revealed that a mixed-consortia of both Saccharomyces and non-Saccharomyces yeasts were responsible for fermentation of khadi, a popular, non-standardized traditional beverage with an immense potential for commercialization in Botswana. Functional characterization of isolated fermenting yeasts from mixed consortia is an indispensable step towards the selection of potential starter cultures for commercialization of khadi. In this study, we report the characterization of 13 khadi isolates for the presence of brewing-relevant phenotypes such as their fermentative capacity, ability to utilize a range of carbon sources and their ability to withstand brewing-associated stresses, as a principal step towards selection of starter cultures. Khadi isolates such as Saccharomyces cerevisiae, Saccharomycodes ludwigii and Candida ethanolica showed good brewing credentials but Lachancea fermentati emerged as the isolate with the best brewing attributes with a potential as a starter culture. However, we were then prompted to investigate the potential of L. fermentati to influence the fruity aromatic flavor, characteristic of khadi. The aroma components of 18 khadi samples were extracted using headspace solid phase micro-extraction (HS-SPME) and identified using a GC-MS. We detected esters as the majority of volatile compounds in khadi, typical of the aromatic signature of both khadi and L. fermentati associated fermentations. This work shows that L. fermentati has potential for commercial production of khadi.