• Title/Summary/Keyword: Head-end

Search Result 531, Processing Time 0.031 seconds

The Behavior and Circulation of Density Current in a Small Reservoir (소규모 저수지에서 밀도류의 거동 및 순환)

  • Yoon, Tae Hoon;Han, Woon Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.11 no.2
    • /
    • pp.27-37
    • /
    • 1991
  • The behavior of a negative buoyant flow flowing into a small reservoir is analysed by experiments and dimensional analysis. The nondimensional plunge point, head velocity, head travel distance and the dilution of density current are dependent on the inflow densimetric Froude number, Fre. The thickness of density current, flow pattern and density difference are different from two cases as follows; before the front of head arrive at the downstream end and after. Before the arrival, the thickness of density current is dependent on Fre and after the arrival, time and Fre. It was found that they can be expressed as power laws.

  • PDF

Evaluation of sperm protamine deficiency and apoptosis in infertile men with idiopathic teratozoospermia

  • Dehghanpour, Fatemeh;Tabibnejad, Nasim;Fesahat, Farzaneh;Yazdinejad, Fatemeh;Talebi, Ali Reza
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.44 no.2
    • /
    • pp.73-78
    • /
    • 2017
  • Objective: Sperm morphology plays an important role in infertility, especially in cases of defects in the heads of spermatozoa. Tapered-head or elongated-head spermatozoa are examples of morphological abnormalities. The aim of this study was to compare the semen parameters, levels of protamine deficiency, and frequency of apoptosis between patients with normozoospermia and those with teratozoospermia with tapered-head spermatozoa. Methods: Fifty-two semen samples (27 patients with tapered-head sperm and 25 fertile men) were collected and semen analysis was performed according to the World Health Organization criteria for each sample. Protamine deficiency and the percentage of apoptotic spermatozoa were evaluated using chromomycin A3 (CMA3) staining and terminal deoxynucleotidyl transferase dUTP nick-end labelling (TUNEL) assays, respectively. Results: Sperm concentration, motility, and normal morphology in the tapered-head spermatozoa (cases) were significantly lower than in the normozoospermic samples (controls). CMA3-reactive spermatozoa (CMA3+) in the case group were more common than in the controls. Apoptotic spermatozoa (TUNEL-positive) were significantly more common in the cases than in the controls. Conclusion: This analysis showed that tapered-head spermatozoa contained abnormal chromatin packaging and exhibited a high rate of apoptosis, which can be considered to be an important reason for the impaired fertility potential in teratozoospermic patients with tapered-head spermatozoa.

Feasibility and Usefulness of No Drain Technique During Parotidectomy (무배액관 이하선 절제술의 실행 가능성과 유용성)

  • Choi, Hyo Geun;Kim, Yoonjoong;Park, Pona;Hong, Seung No;Sung, Myung-Whun;Hah, J.Hun
    • Korean Journal of Head & Neck Oncology
    • /
    • v.28 no.2
    • /
    • pp.122-124
    • /
    • 2012
  • Introduction : No drain technique during parotidectomy had been introduced to reduce postoperative morbidity and to minimize hospital stay in a few previous publications. Since the authors have applied this technique in select patients for several years, we wanted to evaluate the feasibility and usefulness of no drain parotidectomy. Material & Methods : We retrospectively reviewed the medical records of 96 patients who underwent superficial or total parotidectomy by one surgeon from May 2005 to July 2012. The decision on drain insertion was made by the operator at the end of the surgery. The patients were categorized as drain insertion group and no drain group. Results : The patients who have smaller tumors and benign lesions were more frequently chosen into no drain group. Hospital stay was shorter in no drain group than in drain insertion group. Although no drain group showed increased number of acute complications such as seroma and hematoma, the complications were mild and could be controlled easily at the outpatient clinic. Conclusion : No drain technique during parotidectomy could be done relatively safely in select patients and it could reduce hospital stay.

Quality Assurance of Head-end Process of PYRO

  • Kang, Kweon Ho;Cho, Yung Jun;Hong, Seok-Min;Lee, Jae Won;Kim, Young Hwan;Lee, Ju Ho;Lee, Do Youn;Lee, Young Soon;Yoon, Joo Young
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2018.11a
    • /
    • pp.618-619
    • /
    • 2018
  • PDF

Design tables and charts for uniform and non-uniform tuned liquid column dampers in harmonic pitching motion

  • Wu, Jong-Cheng;Wang, Yen-Po;Chen, Yi-Hsuan
    • Smart Structures and Systems
    • /
    • v.9 no.2
    • /
    • pp.165-188
    • /
    • 2012
  • In the first part of the paper, the optimal design parameters for tuned liquid column dampers (TLCD) in harmonic pitching motion were investigated. The configurations in design tables include uniform and non-uniform TLCDs with cross-sectional ratios of 0.3, 0.6, 1, 2 and 3 for the design in different situations. A closed-form solution of the structural response was used for performing numerical optimization. The results from optimization indicate that the optimal structural response always occurs when the two resonant peaks along the frequency axis are equal. The optimal frequency tuning ratio, optimal head loss coefficient, the corresponding response and other useful quantities are constructed in design tables as a guideline for practitioners. As the value of the head loss coefficient is only available through experiments, in the second part of the paper, the prediction of head loss coefficients in the form of a design chart are proposed based on a series of large scale tests in pitching base motions, aiming to ease the predicament of lacking the information of head loss for those who wishes to make designs without going through experimentation. A large extent of TLCDs with cross-sectional ratios of 0.3, 0.6, 1, 2 and 3 and orifice blocking ratios ranging from 0%, 20%, 40%, 60% to 80% were inspected by means of a closed-form solution under harmonic base motion for identification. For the convenience of practical use, the corresponding empirical formulas for predicting head loss coefficients of TLCDs in relation to the cross-sectional ratio and the orifice blocking ratio were also proposed. For supplemental information to horizontal base motion, the relation of head loss values versus blocking ratios and the corresponding empirical formulas were also presented in the end.

A Comparison of Dizziness Handicap Inventory Scores with Stability Index and Fourier Harmony Index in Healthy Individuals

  • Sang-Seok Yeo;Heun-Jae Ryu
    • The Journal of Korean Physical Therapy
    • /
    • v.35 no.4
    • /
    • pp.105-110
    • /
    • 2023
  • Purpose: The purpose of this study was to determine whether the degree of dizziness affects static balance due to the disruption or absence of the senses involved in balance. To this end, the correlation between the Dizziness Handicap Inventory (DHI), which objectively evaluates dizziness, the Fourier Index (FI; Frequency bands of postural oscillation, F1, F2-4, F5-6, F7-8) and the Stability Index (ST), which evaluates static balance ability, were examined. Methods: This study investigated balance and dizziness issues in 30 healthy young adults. Participants underwent multiple tests like the DHI and tetra-ataxiometric posturography (Tetrax) under different conditions (eyes open/closed, standing on a foam-rubber pillow, and with the head in various orientations). Results: We found that F1 exhibited a weak positive correlation with dizziness under normal conditions, as well as when the eyes were closed (r=0.396, p<0.05) and the head was tilted back (r=0.375, p<0.05). Meanwhile, F5-6 showed a moderate positive correlation with dizziness in both head-back (HB: r=0.471, p<0.05) and head-forward postures (r=0.404, p<0.05). Lastly, both F7-8 and ST demonstrated a moderate positive correlation with dizziness when the head was in a forward posture (F7-8: r=0.483; ST: r=0.403, p<0.05). Conclusion: The study results indicate that the severity of dizziness affects sensory systems and balance. It also suggests that head movements, especially forward and backward, further stimulate the vestibular system, intensifying dizziness, and balance problems in affected individuals.

Scanning Electron Microscopic Study on the Head Lice Eggs Detected in Korean Children

  • Park, Mi Soon;Chang, Byung Soo
    • Applied Microscopy
    • /
    • v.44 no.2
    • /
    • pp.47-52
    • /
    • 2014
  • Fine structural characteristics of eggs (nits) found on the scalp hairs of Korean children were observed with scanning electron microscopy. An egg is structurally composed of four parts: the cementum, nit body, operculum, and aerophyle. The total length of an egg is about 1.5 mm. The glue secreted from the female louse completely surrounds the 1 mm hair shaft and forms the cementum. The thickness of the cementum at the end of the nit body was found to be more than 5 times the thickness at the end toward the scalp. The nit body is shaped like a goblet with a very smooth surface. The operculum and aerophyles are located at the apiculus area. In the circular operculum, there are 10 aerophyles concentrated on the side of the hair shaft surface that are shaped like a dome. Three aerophyles in the center are surrounded by 7 aerophyles. Each aerophyle is dome shaped with a diameter of $65{\mu}m$ and a respiratory pathway with a $15{\sim}25{\mu}m$ opening at the center. On the cut surface where the operculum is separated as the egg hatches, long grooves about $1{\mu}m$ thick are uniformly formed transversely. These long grooves facilitate the separation of the operculum through body expansion at the time of hatching.

Which is the proper insertion method of laryngeal mask airway according to the rescuer's position? : Comparison between index finger insertion and thumb insertion (구조자의 위치에 따른 적절한 후두마스크기도기 삽입방법은 무엇일까? : 검지손가락법과 엄지손가락법의 비교)

  • Chun, Kyoung-Ha;Moon, Jun-Dong
    • The Korean Journal of Emergency Medical Services
    • /
    • v.21 no.3
    • /
    • pp.7-16
    • /
    • 2017
  • Purpose: The purpose of the study was to investigate the effects of laryngeal mask airway (LMA) insertion from different positions, using different methods, on the quality of the insertion, for identifying a more convenient and effective insertion method. Methods: In a model ambulance, 30 paramedic students performed the LMA insertion procedure, in four different settings, combinations of the rescuer's position (at the head end of the patient, at the side of the patient), and insertion technique (index finger insertion, thumb insertion), in a randomized order. Quality of insertion index and convenience of use were measured. Results: The quality of insertion index (tidal volume, gastric insufflation, airway pressure, airway sealing pressure, midline positions, insertion success grade, and insertion time) were not significantly different among four different settings. However LMA insertion from the anterior (head) end, using the index finger method compared to the thumb method was found to be significantly more convenient. Conclusion: We recommend using the more convenient and familiar LMA insertion method, between index finger insertion and thumb insertion, regardless of rescuer's position.

Development of Customizing Program for Finite Element Analysis of Pressure Vessel (압력 용기 유한 요소 해석 프로그램 개발)

  • Jeon, Yoon-Cheol;Kim, Tae-Woan
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.654-659
    • /
    • 2003
  • PVAP (Pressure Vessel Analysis Program V1.0) was developed by adopting the finite element analysis program ANSYS V6.0, and Microsoft Visual Basic V6.0 was also utilized for the interfacing and handling of input and output data during the analysis. PVAP offers the end user the ability to design and analyze vessels in strict accordance with ASME Section VIII, Division 2. More importantly, the user is not required to make any design decisions during the input of the vessel. PVAP consists of three analysis modules for the finite element analysis of the primary components of pressure vessel such as head, shell, nozzle, and skirt. In each module, finite element analysis can be performed automatically only if the end user gives the dimension of the vessel. Furthermore, the calculated results are compared and evaluated in accordance with the criteria given in ASME Boiler and Pressure Vessel Code, Section VIII, Division 2. In particular, heat transfer analysis and consecutive thermal stress analysis for the junction between skirt and head can be carried out automatically in the skirt-tohead module. Finally, report including the above results is created automatically in Microsoft Word format.

  • PDF