• Title/Summary/Keyword: Head neck

Search Result 4,542, Processing Time 0.036 seconds

Usability Assessment of Plan Transfer between TOMO HAD and Radixact : Planning Study (TOMO HDA와 Radixact 치료 계획 간 Transfer에 대한 유용성 평가 : Planning Study)

  • An, Ye Chan;Kim, Jong Sik;Kwon, Dong Yeol;Kim, Jin Man;Choi, Byeong Ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.117-128
    • /
    • 2018
  • Purpose : To evaluate the usability of plan transfer between TOMO HD and Radixact, we compared the differences of dose in transferred plans by evaluating the dose of normal organ and target. TOMO HDA and Radixact. The completed plans were transferred each other and we compared the differences of dose by evaluating the DVH of each plans. Materials and Methods : We planned 4 different plans assuming the treatment of 2 cases in Head and Neck Cancer and 2 cases Prostate cancer. Each plan was designed so that 95 % of the prescription dose was irradiated over 99 % of the target volume, and the normal organ constraints dose was based on the SMC tolerance dose protocol. Each plan was transferred to each equipment and DVH(dose volume histogram) analysis of the transferred plans was compared and evaluated. Results : The Mean dose of CTV and GTV was increased and decreased in the transferred plans, but there was no significant differences. The target coverage of CTV and GTV was decreased in all cases of transferred plans from TOMO HAD to Radixact, and the change of CI and HI in CTV was within 0.1. Normal organ dose was increased in most cases when transferring from HAD to Radixact in both treatment plans. Conclusion : According to the results of this experiment, the target coverage was above the standard and the normal organ dose was almost same or decreased when transferring the plans from Radixact to HDA equipment. However the target coverage was reduced when transferring the plans from HDA to Radixact and there was an increase in dose in normal organs that could cause sever side effects such as Optic Chiasm ($D_{max}$1.38 Gy), Bladder ($D_{max}$3.07 Gy), Penile Bulb ($D_{max}$1.14 Gy). Therefore, it is necessary to pay attention to the dose change when transferring the plan and one-time transfer due to equipment inspection will be useful for efficient radiation therapy, but if the transferred treatment plans continue for several consecutive days, the treatment plan should be resumed.

  • PDF

Automated patient set-up using intensity based image registration in proton therapy (양성자 치료 시 Intensity 기반의 영상 정합을 이용한 환자 자동화 Set up 적용 방법)

  • Jang, Hoon;Kim, Ho Sik;Choe, Seung Oh;Kim, Eun Suk;Jeong, Jong Hyi;Ahn, Sang Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.97-105
    • /
    • 2018
  • Purpose : Proton Therapy using Bragg-peak, because it has distinct characteristics in providing maximum dosage for tumor and minimal dosage for normal tissue, a medical imaging system that can quantify changes in patient position or treatment area is of paramount importance to the treatment of protons. The purpose of this research is to evaluate the usefulness of the algorithm by comparing the image matching through the set-up and in-house code through the existing dips program by producing a Matlab-based in-house registration code to determine the error value between dips and DRR to evaluate the accuracy of the existing treatment. Materials and Methods : Thirteen patients with brain tumors and head and neck cancer who received proton therapy were included in this study and used the DIPS Program System (Version 2.4.3, IBA, Belgium) for image comparison and the Eclipse Proton Planning System (Version 13.7, Varian, USA) for patient treatment planning. For Validation of the Registration method, a test image was artificially rotated and moved to match the existing image, and the initial set up image of DIPS program of existing set up process was image-matched with plan DRR, and the error value was obtained, and the usefulness of the algorithm was evaluated. Results : When the test image was moved 0.5, 1, and 10 cm in the left and right directions, the average error was 0.018 cm. When the test image was rotated counterclockwise by 1 and $10^{\circ}$, the error was $0.0011^{\circ}$. When the initial images of four patients were imaged, the mean error was 0.056, 0.044, and 0.053 cm in the order of x, y, and z, and 0.190 and $0.206^{\circ}$ in the order of rotation and pitch. When the final images of 13 patients were imaged, the mean differences were 0.062, 0.085, and 0.074 cm in the order of x, y, and z, and 0.120 cm as the vector value. Rotation and pitch were 0.171 and $0.174^{\circ}$, respectively. Conclusion : The Matlab-based In-house Registration code produced through this study showed accurate Image matching based on Intensity as well as the simple image as well as anatomical structure. Also, the Set-up error through the DIPS program of the existing treatment method showed a very slight difference, confirming the accuracy of the proton therapy. Future development of additional programs and future Intensity-based Matlab In-house code research will be necessary for future clinical applications.

  • PDF

Polarization-sensitive Optical Coherence Tomography Imaging of Pleural Reaction Caused by Talc in an ex vivo Rabbit Model (생체 외 토끼 모델에서의 탈크에 의해 유발되는 흉막 반응의 편광 민감 광 결맞음 단층촬영 이미징)

  • Park, Jung-Eun;Xin, Zhou;Oak, Chulho;Kim, Sungwon;Lee, Haeyoung;Park, Eun-Kee;Jung, Minjung;Kwon, Daa Young;Tang, Shuo;Ahn, Yeh-Chan
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.1
    • /
    • pp.1-6
    • /
    • 2020
  • The chest wall, an organ directly affected by environmental particles through respiration, consists of ribs, a pleural layer and intercostal muscles. To diagnose early and treat disease in this body part, it is important to visualize the details of the chest wall, but the structure of the pleural layer cannot be seen by chest computed tomography or ultrasound. On the other hand, optical coherence tomography (OCT), with a high spatial resolution, is suited to observe pleural-layer response to talc, one of the fine materials. However, intensity-based OCT is weak in providing information to distinguish the detailed structure of the chest wall, and cannot distinguish the reaction of the pleural layer from the change in the muscle by the talc. Polarization-sensitive OCT (PS-OCT) takes advantage of the fact that specific tissues like muscle, which have optical birefringence, change the backscattered light's polarization state. Moreover, the birefringence of muscle associated with the arrangement of myofilaments indicates the muscle's condition, by measuring retardation change. The PS-OCT image is interpreted from three major perspectives for talc-exposure chest-wall imaging: a thickened pleural layer, a separation between pleural layer and muscle, and a phase-retardation measurement around lesions. In this paper, a rabbit chest wall after talc pleurodesis is investigated by PS-OCT. The PS-OCT images visualize the pleural layer and muscle, respectively, and this system shows different birefringence of normal and damaged lesions. Also, an analyisis based on phase-retardation slope supports results from the PS-OCT image and histology.

Effect of environmental temperature on respiration rate, rectal temperature and body-surface temperatures in finishing pigs (환경온도가 비육돈의 호흡수, 직장 온도 및 체표면 온도에 미치는 영향)

  • Cheon, Si-Nae;Park, Kyu-Hyun;Choi, Hee-Chul;Kim, Jong-bok;Kwon, Kyeong-Seok;Lee, Jun-Yeob;Woo, Saem-Ee;Yang, Ga-Yeong;Jeon, Jung-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.1
    • /
    • pp.103-110
    • /
    • 2019
  • Recently, Korea has been affected by extreme weather events including extended summers and increased temperatures caused by global warming and climate change. Environmental temperature is especially important to the livestock industry because it is closely related to livestock productivity. This study was conducted to investigate the influence of different environmental temperatures on respiration rate, rectal temperature and body-surface temperature in finishing pigs. Pigs ($98.3{\pm}6.6kg$) were housed in individual cages inside an experimental chamber and exposed continuously to one of five environmental treatments ($22^{\circ}C$, $24^{\circ}C$, $26^{\circ}C$, $28^{\circ}C$, $30^{\circ}C$) for 10 days without providing additional rest time. Feed and water intake, respiration rate, rectal temperature and body-surface (head, ear, neck, back, side) temperature were measured two times daily during the experimental period. A significant increase in respiration rate from $26^{\circ}C$ and in body-surface temperature from $24^{\circ}C$ (p<0.05) was observed. At $30^{\circ}C$, the respiration rate had almost doubled and the body-surface temperature increased by about $5^{\circ}C-7^{\circ}C$. Moreover, ear skin temperature was very sensitive to environmental temperature. However, feed intake, water intake and rectal temperature did not change significantly during the experiment.

Effects of vocal aerobic treatment on voice improvement in patients with voice disorders (성대에어로빅치료법이 음성장애환자의 음성개선에 미치는 효과)

  • Park, Jun-Hee;Yoo, Jae-Yeon;Lee, Ha-Na
    • Phonetics and Speech Sciences
    • /
    • v.11 no.3
    • /
    • pp.69-76
    • /
    • 2019
  • This study aimed to investigate the effects of vocal aerobic treatment (VAT) on the improvement of voice in patients with voice disorders. Twenty patients (13 males, 7 females) were diagnosed with voice disorders on the basis of videostroboscopy and voice evaluations. Acoustic evaluation was performed with the Multidimensional voice program (MDVP) and Voice Range Profile (VRP) of Computerized Speech Lab (CSL), and aerodynamic evaluation with PAS (Phonatory Aerodynamic System). The changes in F0, Jitter, Shimmer, and NHR before and after treatment were measured by MDVP. F0 range and Energy range were measured with VRP before and after treatment, and the changes in Expiratory Volume (FVC), Phonation Time (PHOT), Mean Expiratory Airflow (MEAF), Mean Peak Air Pressure (MPAP), and Aerodynamic Efficiency (AEFF) with PAS. Videostroboscopy was performed to evaluate the regularity, symmetry, mucosal wave, and amplitude changes of both vocal cords before and after treatment. Voice therapy was performed once a week for each patient using the VAT program in a holistic voice therapy approach. The average number of treatments per patient was 6.5. In the MDVP, Jitter, Shimmer, and NHR showed statistically significant decreases (p < .001, p < .01, p < .05). VRP results showed that Hz and semitones in the frequency range improved significantly after treatment (p < .01, p < .05), as did PAS, FVC, and PHOT (p < .01, p < .001). The results for videostroboscopy, functional voice disorder, laryngopharyngeal reflux, and benign vocal fold lesions were normal. Thus, the VAT program was found to be effective in improving the acoustic and aerodynamic aspects of the voice of patients with voice disorders. In future studies, the effect of VAT on the same group of voice disorders should be studied. It is also necessary to investigate subjective voice improvement and objective voice improvement. Furthermore, it is necessary to examine the effects of VAT in professional voice users.

Development of smartphone-based voice therapy program (스마트폰기반 음성치료 프로그램 개발연구)

  • Lee, Ha-Na;Park, Jun-Hee;Yoo, Jae-Yeon
    • Phonetics and Speech Sciences
    • /
    • v.11 no.1
    • /
    • pp.51-61
    • /
    • 2019
  • The purpose of this study was to develop a smartphone based voice therapy program for patients with voice disorders. Contents of voice therapy were collected through analysis of mobile contents related to voice therapy in Korea, experts and users' demand survey, and the program was developed using Android Studio. Content needed for voice therapy was collected through analysis of mobile contents related to voice therapy. The user satisfaction evaluation for application was conducted for five patient with functional voice disorders. The results showed that the mobile contents related to voice therapy in Korea were mostly related to breathing, followed by voice and singing, but only 13 applications were practically practiced for voice therapy. Expert and user demand surveys showed that the patients and therapists both had a high need for content that could provide voice training in places other than the treatment room. Based on this analysis, 'Home Voice Trainer', an smartphone based voice therapy program, was developed. Home Voice Trainer is an application for voice therapy and management based on Android smartphones. It is designed to train voice therapy activities at home that have been trained offline. In addition, the records of voice training of patients were managed online so that patients can maintain voice improvement through continuous voice consulting even after the end of voice therapy. User evaluations show that patients are satisfied with the difficulty and content of voice therapy programs provided by home voice trainers, but lack of a portion of user interface, such as the portion of home button and interface between screens. Further study suggests the clinical application of home voice trainer to the patients with voice disorders. It is expected that the development study and the clinical application of smart contents related to voice therapy will be actively conducted.

Comparison for the Optimal Pressure between Manual CPAP and APAP Titration with Obstructive Sleep Apnea Patients (한국인 폐쇄성 수면 무호흡 환자의 적정 양압을 위한 수동화 양압 측정법과 자동화 양압 측정법의 비교)

  • Kim, Dae Jin;Choi, Byoung Geol;Cho, Jae Wook;Mun, Sue Jean;Lee, Min Woo;Kim, Hyun-Woo
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.2
    • /
    • pp.191-197
    • /
    • 2019
  • Although auto-adjusting positive airway pressure (APAP) titration at home has several advantages over a CPAP titration in terms of convenience and time saving, there are still concerns as to whether it will show corresponding accuracy when compared to laboratory-based polysomnography (PSG) and CPAP titration. To obtain more evidence supporting home-based auto-titration, APAP titration was performed at home for patients who were presented with OSA on laboratory-based diagnostic PSG followed by CPAP titration. A total of 79 patients were included in the study. They all underwent split-night PSG with CPAP titration, and APAP titration for more than 7 days. The patients with successful titration at both situations were selected. The optimal pressure and apnea-hypopnea index (AHI) of CPAP and APAP titration were compared. The optimal pressure for CPAP and APAP titration were $7.0{\pm}1.8cmH_2O$ and $7.6{\pm}1.6cmH_2O$ (P<0.001), whereas the corresponding AHI were $1.3{\pm}1.5/h$ and $3.0{\pm}1.7/h$ (P<0.001). As a result, the achievement rates of optimal pressure for CPAP and APAP titration were 96.2% and 94.9% (r=-0.045, P=0.688), respectively. The results of this study did not differ with regard to the optimal pressure between CPAP and APAP titration. Overall, CPAP and APAP titrations should be chosen depending on a required situation.

'Hwawang': A Good Quality and Early-Maturing Rice Variety Adaptable for Rice-Cash Crop Rotation System (소득작물 후작용 고품질 조생 벼품종 '화왕')

  • Lee, Jong-Hee;Lee, Ji-Yoon;Yeo, Un-Sang;Song, You-Chun;Park, Dong-Soo;Hwang, Un-Hwa;Park, Soo-Gwan;Park, No-Bong;Kim, Sang-Yeol;Oh, Seong-Hwan;Han, Sang-Ik;Nam, Min-Hee;Lee, Jong-Gi;Cho, Jun-Hyeon
    • Korean Journal of Breeding Science
    • /
    • v.50 no.4
    • /
    • pp.534-539
    • /
    • 2018
  • 'Hwawang' is an early maturing and short statured rice cultivar adaptable to the rice-cash crop rotation system that was developed by the rice breeding team of the Department of Southern Crop, National Institute of Crop Science (NICS), Rural Development Administration (RDA), Korea, in 2012. This cultivar was derived from the cross of YR25867 (Hitomebore//YR21247-B-B-B-49-1/Sasanishiki BL4) and YR25866 (Akidagomachi//YR21247-B-B-B-49-1/Sasanishiki BL4) during the 2005/2006 winter season and was fixed as a homozygous line by a doubled haploid breeding system. In the replicated yield trial in 2009, a promising line (YR26253Acp26-1) showed a good phenotype and high yield potential, and so it was selected and designated as 'Milyang256'. The local adaptability test of 'Milyang256' was carried out at three locations from 2010 to 2012. It was named 'Hwawang' and had a high head rice ratio and good eating quality. The culm length of 'Hwawang' averaged 62 cm during the yield trials and was 10 cm shorter than that of 'Keumo'. The number of spikelets per panicle of 'Hwawang' was significantly lower than that of 'Keumo', but the number of tillers per hill was higher. This variety showed resistance to bacterial blight disease but was moderately susceptible to both leaf and neck blast. The milled rice yield of 'Hwawang' was 452 kg/10 a at the late transplanting stage of the local adaptability test. Thus, 'Hwawang' is well adapted to the rice-cash crop rotation system in the southern plain area. (Registration No. 5106)

A Study on Superficial Dose of 6MV-FFF in HalcyonTM LINAC: Phantom Study (HalcyonTM 선형가속기 6MV-FFF 에너지의 표재 선량에 대한 고찰: Phantom Study)

  • Choi, Seong Hoon;Um, Ki Cheon;Yoo, Soon Mi;Park, Je Wan;Song, Heung Kwon;Yoon, In Ha
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.31-39
    • /
    • 2020
  • Purpose: The aims of this study were to compare the superficial dose with Optically Stimulated Luminescence Dosimeter(OSLD) measurement and Treatment Planning System(TPS) calculation for 6MV-Flattening Filter Free(FFF) energy using HalcyonTM and TrueBeamTM. Materials and methods: Phantom study was performed using the CT images of human phantom. In the treatment planning system, the Planning Target Volume(PTV) was contoured which is similar to Glottic cancer. Furthermore, Point(M), Point(R), and Point(L) were contoured at the iso-center of head and neck region and 5mm bolus was applied to the body contour. Each treatment plans using 6MV-FFF energy from HalcyonTM and TrueBeamTM with static Intensity Modulated Radiation Therapy(IMRT) and Volumetric Modulated Arc Therapy(VMAT) were established with eclipse. To reproduce the same position as the TPS, OSLDs were placed at the iso-center point and 5mm bolus was applied to compare the error rate after the dose delivery. Result: The results of the study using human phantom are as follows. In case of HalcyonTM, the mean absolute error rates of the point dose using the treatment planning system and the dose measured by OSLD were 1.7%±1.2% for VMAT and 4.0±2.8% for IMRT. Also TrueBeamTM was identified as 2.4±0.4% and 8.6±1.8% respectively for VMAT and IMRT. Conclusion: Through the results of this study, TrueBeamTM confirmed that the average error rate was 2.4 times higher for VMAT and 3.6 times higher for IMRT than HalcyonTM. Therefore, based on the results of this study, If we need a more accurate dose assessment for the superficial dose, It is expected that using HalcyonTM would be better than TrueBeamTM.

A Study on the Perception of Concurrent Use of Western and Korean Medicine Care and Integrated Medical Service in Korea - Targeting tertiary hospital users - (의-한의 동시 진료 및 통합의료서비스에 대한 인식조사 - 3차 상급종합병원 이용자를 대상으로 -)

  • Seo, Sangwoo;Kim, Hyungsuk;Lee, Seung Hyeun;Kong, Moonkyoo;Lee, Beom-Joon;Heo, Sung Hyuk;Kwon, Seung-won;Park, Bong Jin;Yun, Dong Hwan;Lee, Euiju;Oh, Hyunjoo;Kim, Sung-Bum;Choi, Hye-Sook;Kim, Kwan-Il;Chung, Won-Seok
    • The Journal of Korean Medicine
    • /
    • v.43 no.2
    • /
    • pp.51-60
    • /
    • 2022
  • Objectives: Currently, Korea's medical services are divided into Western medicine and Korean medicine, and people who are not satisfied with the existing treatments are looking for complementary and alternative medicine(CAM). Therefore, this study attempted to confirm patients' perception of the ongoing collaborative treatment and integrated medical service that added CAM to collaborative treatment based on tertiary hospital users. So that we can confirm the expected advantage and disadvantage of integrated medical service system and the necessity of supporting medical expenses for it. Methods: The survey was conducted on 100 people who experienced tertiary hospital treatment and other 100 people who experienced both tertiary hospital treatment and Korean medicine treatment at the same period. The survey was conducted until the number of respondents in both group reached 100. The survey was conducted through e-mail and was conducted from September 27, 2021 to October 8, 2021. Results: For the advantages of collaborative treatment 'increased in psychological stability,' and for disadvantages 'longer time spent for treatment' were the most common. If integrated medical services are implemented in the future, expected advantages include 'consideration of various treatments.' and expected disadvantages include 'increased medical cost.' The needs to expand support for health insurance for integrated medical services were 75.5% among responders. Conclusions: We were able to find out the (expected) advantages and disadvantages of the collaborative medical care and the integrated medical system that medical users experienced or expected, also confirmed positive answers to the expansion of health insurance support for the integrated medical system.