• 제목/요약/키워드: Head fracture

검색결과 344건 처리시간 0.029초

Management of Unilateral Facet Dislocation of the Cervical Spine

  • Baek, Geum-Seong;Lee, Woo-Jong;Koh, Eun-Jeong;Choi, Ha-Young;Eun, Jong-Pil
    • Journal of Korean Neurosurgical Society
    • /
    • 제41권5호
    • /
    • pp.295-300
    • /
    • 2007
  • Objective : Unilateral facet dislocation of the cervical spine occurs by flexion and rotation injuries and cannot be easily reduced by axial traction. We analyzed 14 consecutive patients with unilateral facet dislocation of the cervical spine to increase knowledge about anatomical reduction of locked facet and factors for successful reduction. Methods : Fourteen patients [10 men and 4 women] with unilateral facet dislocation of the cervical spine were retrospectively analyzed. Plain X-ray, computerized tomography scan, and magnetic resonance imaging were performed. All patients underwent manual reduction and surgery with anterior interbody fusion and plate fixation. The manual reduction was performed by neck flexion and rotation to the opposite side of dislocation, followed by rotation and flexion of the head toward the side of dislocation and extension with relaxation of traction. Mean follow-up period was 17 months. The level of spine, amount of subluxation, combined facet fracture, and time from injury to initial reduction were analyzed using the data obtained from medical records. Results : Thirteen [93%] patients were reduced successfully. Immediate reduction was achieved in 7 patients but failed in 7 patients. Seven patients underwent delayed closed reduction under general anesthesia, and successful reduction was achieved in 6 patients. Only one patient with bone chips between articular facets failed to achieve anatomical reduction. Conclusion : In order to reduce the locked facet more easily and safely, we recommend manipulative traction with anterior interbody fusion and plate fixation under general anesthesia after being aware of spinal cord injury with magnetic resonance imaging.

Influence of various metal oxides on mechanical and physical properties of heat-cured polymethyl methacrylate denture base resins

  • Asar, Neset Volkan;Albayrak, Hamdi;Korkmaz, Turan;Turkyilmaz, Ilser
    • The Journal of Advanced Prosthodontics
    • /
    • 제5권3호
    • /
    • pp.241-247
    • /
    • 2013
  • PURPOSE. To evaluate the effect of various metal oxides on impact strength (IS), fracture toughness (FT), water sorption (WSP) and solubility (WSL) of heat-cured acrylic resin. MATERIALS AND METHODS. Fifty acrylic resin specimens were fabricated for each test and divided into five groups. Group 1 was the control group and Group 2, 3, 4 and 5 (test groups) included a mixture of 1% $TiO_2$ and 1% $ZrO_2$, 2% $Al_2O_3$, 2% $TiO_2$, and 2% $ZrO_2$ by volume, respectively. Rectangular unnotched specimens ($50mm{\times}6.0mm{\times}4.0mm$) were fabricated and drop-tower impact testing machine was used to determine IS. For FT, compact test specimens were fabricated and tests were done with a universal testing machine with a cross-head speed of 5 mm/min. For WSP and WSL, disc-shaped specimens were fabricated and tests were performed in accordance to ISO 1567. ANOVA and Kruskal-Wallis tests were used for statistical analyses. RESULTS. IS and FT values were significantly higher and WSP and WSL values were significantly lower in test groups than in control group (P<.05). Group 5 had significantly higher IS and FT values and significantly lower WSP values than other groups (P<.05) and provided 40% and 30% increase in IS and FT, respectively, compared to control group. Significantly lower WSL values were detected for Group 2 and 5 (P<.05). CONCLUSION. Modification of heat-cured acrylic resin with metal oxides, especially with $ZrO_2$, may be useful in preventing denture fractures and undesirable physical changes resulting from oral fluids clinically.

시효처리와 thermal cycling이 치관전장용 복합레진의 2축굽힘강도에 미치는 영향 (EFFECTS OF AGING AND THERMAL CYCLING ON THE BIAXIAL FLEXURE STRENGTH OF VENEERING RESIN COMPOSITES FOR CROWN)

  • 정관호;하일수;송광엽
    • 대한치과보철학회지
    • /
    • 제37권5호
    • /
    • pp.597-606
    • /
    • 1999
  • This study was performed to evaluate the effect of aging and thermal cycling on the biaxial flexure strength of low commercially available veneering resin composites for crown(Dentacolor : DC, Artglass : AG, Esternia : ET and Targis : TG). Disc specimens were fabricated in a teflon mold giving 12mm in diameter and 1mm in thickness. All samples were divided into 4 groups. Group 1 was dried in a dessicator at $25^{\circ}C$ for 30 days. Group 2 was immersed in distilled water at $37^{\circ}C$ for 30 days. Group 3 was immersed in distilled water at $65^{\circ}C$ for 30 days. Group 4 was subjected to 10,000 thermal cycles between $5^{\circ}C\;and\;55^{\circ}C$, and the immersion time in each bath was 15 seconds per cycle. Biaxial flexure test was conducted using the ball-on-three-ball method at the cross head speed of 0.5mm/min and fracture surfaces were observed with scanning electoron microscope. The results obtained were summarized as follows; 1. Weibull modulus values, except for the AG group, decreased after thermal cycling treatment. 2. Biaxial flexure strength values of aging group at $37^{\circ}C$ were the lowest in all sample groups. Except for the DC group, strength values were significantly decreased for the drying group. 3. After thermal cycling test, the highest value of biaxial flexure strength of 188.8 MPa was observed in the ET group and the lowest value of 73.2 MPa was observed in the DC group. The strength values showed the significant differences in each group (p<0.05). 4. Observation of surfaces after thermal cycling test revealed the ditching in the part of surrounding large fillers.

  • PDF

전부도재수복물을 위한 유색 및 무색 지르코니아 세라믹의 굴곡강도 (Flexure Strength of Various Colored and Uncolored Zirconia Ceramics for All-Ceramic Restoration)

  • 오상천;이해형;신미란;이일권
    • 구강회복응용과학지
    • /
    • 제23권2호
    • /
    • pp.119-130
    • /
    • 2007
  • Purpose: This investigation was designed to estimate the flexure strength, density, and microstructure of the colored and uncolored zirconia oxide ceramics for fixed partial denture. Material and Methods: LAVATM All Ceramic(3M-ESPE, USA), Cercon Smart Ceramic(Dentsply, USA), and Z-match Ceramic(DentAim, Korea) were used for this study. All specimen was fabricated by ASTM C1161. After preparing $25{\times}2{\times}1.5mm$ of rectangular column and sitting rectangular column on universal test machine (UTM), external supporting point distance is 20.0 mm, internal supporting point distance is 10.0 mm. Specimen was loaded with 0.2 mm/min of cross head speed until fracture and at the time of broken of specimen, measuring loading value with PC software. Results: The results were obtained as follows: 1. Flexure strength of uncolored zirconia was higher than that of colored zirconia. 2. In uncolored zirconia, flexure strength of LAVATM Ceramic was more higher than the other ceramics, and it showed statistical difference between LAVATM Ceramic and Cercon Smart Ceramic (P<0.05). 3. In colored zirconia, flexure strength of LAVATM Ceramic was more higher than the other ceramics too, but they did not show statistical difference (p>0.05). 4. In Weibull analysis, Characterastic strength was showed highest value to uncolored LAVATM Ceramic and lowest value to Z-match ceramic, and Weibull modulus(m) of uncolored zirconia was higher than that of colored zirconia. 5. In XRD analysis, all group except Z-match showed high peak of t-ZrO2 but they did not show m-ZrO2. Colored zirconia group showed lower peak of t-ZrO2 than that of uncolored zirconia group.

내반주 변형에 의한 지연성 척골 신경 마비 (Tardy Ulnar Nerve Palsy due to Cubitus Varus Deformity)

  • 전인호;김풍택;박병철;인주철
    • Clinics in Shoulder and Elbow
    • /
    • 제5권1호
    • /
    • pp.29-36
    • /
    • 2002
  • Purpose : Cubitus varus deformity has been reported to cause ulnar neuropathy. We present five cases of tardy ulnar nerve palsy due to cubitus vus and analyzed the factors related to the nerve plasy caused by the deformity. Materials and Methods : Three men and two women were reviewed retrospectively and the mean age of the patients were 26 (range, 14-38). The average interval from initial fracture to nerve palsy was 19 years (8-32 years). The severity of symptoms, according to McGowan's classification, was grade I of 2 patients, grade Ⅱ of 3 patients. Carrying angle was an average of 18。 (30° -45° ). Internal rotation angle measured by Yamamoto's method was an average of 33° (30° -45° ). Results ㆍ The mean follow-up period was 53 months (35-70 months). Elbow pain and numbness of the fingers were relieved shortly after surgery. It revealed that anterior subluxation of the nerve due to internal rotation deformity and compression of the nerve between the medially shifted medial head of triceps and the medial epicondyle. Conclusion : The major entrapment point of the nerve is the fibrous band between the two heads of the flexor carpi ulnaris. The severe internal rotation deformity may contribute the cause of tardy ulnar nerve palsy in cubitus varus deformity.

개에서 발생한 주관절 탈구와 완관절 아탈구의 방사선학적 진단 (Radiological Diagnosis of Elbow Luxation and Subluxation of Carpal Joint in the Dog)

  • 김상기;이정길;박인철
    • 한국임상수의학회지
    • /
    • 제11권1호
    • /
    • pp.369-376
    • /
    • 1994
  • The purpose of this report Is to discribe the radiological findings of traumatic elbow luxation and subluxation of carpal joint which were caused by being hit by a wild animal and forced hyperextension of carpus in two hunting dogs. In case 1, carniocaudal and mediolateral radiographic examination of the elbow joint revealed that the radius that the radius and ulna were completely luxated laterally. The lateral projection showed the humeral condyles overlying the radial head with an absent joint space, but displacement is apparent on the craniocaudal projection. Incidence of collateral ligament rupture in conjunction with elbow luxation was not recognized on physical examination of the limb after closed reduction. Radiographic examination of the elbow made 5 months after closed reduction revealed only mild degenerative joint disease. Radiographic examination of the carpus in case 2 demonstrated palmar subluxation of most carpal joints including antebrachiocarpal, mediocarpal carpometacarpal joints, and some intercarpal joints, and avulsion fracture of the palmar surface of the accessory carpal bone. However, the mediocarpal and carpometacarpal joints were most severely affected by tensile forces of hyperextension, and it was concluded that the ligaments of the middle ca,pal joints and carpometacarpal joints as well as the palmar fibrocartilage were ruptured based on clinical and radiographic findings. In elbow luxation and subluxation of carpal Joints of the dog, differentiation of the joint or joints involved, and ligamentous structures damaged is important in determining whether surgery Is necessary and which procedure is most appropriate. And the radiographic findings of these conditions would be of help to practitioners.

  • PDF

건설산업재해 원인분석 조사연구 (The Study of Field Survey for the Analysis of Occupational Accident Causes in Korean Construction Industry)

  • 이영섭
    • 한국안전학회지
    • /
    • 제1권1호
    • /
    • pp.51-59
    • /
    • 1986
  • This study was conducted to analyse the exact causes of occupational accidents in Korean construction industry and to contribute to the accident prevention programs. The results and conclusions of the field survey are as follows : 1) The accidents caused by hazardous conditions are 96 percent, and those by unsafe acts are 97.3 percent. The accidents caused simultaneously by two categories are nore than 96 percent. 2) The injured workers who were employed less than 3 months are 71.1 percent. Safety training for newly recruited workers should be required. 3) More than 40 percent of all accidents were occurred in the morning and more than 30 percent were in summer. Required caution should be paid for the time and season. 4) Fracture, cut/laceration/puncture and multiple injuries in the lower extremeties, upper entremeties and head as well as many kinds of injuries by the fall from elevation mainly occurred. Safety. shoes, safety gloves, safety helmets, safety glasses, face shields and safity belts should be used 5) As the sources of injuries, each of building/structure and materials is one third of all sources, and machinery is a quarter. 6) The use of hazardous methods/procedures, defects of agencies and inadequate guarding of builing/structure, materials' and machinery mainly caused the accident types, such as s truck by, struck against, fall from elevation, and fall on same level. Such a hazardous conditiion should not be used and be correctet 7) The unsafe acts, such as improper use of hands or body parts, the operation or working at unsafe speed and improper use of equipment mainly caused accidents. Safety training for the control of such a unsafe acts should be strengthened.

  • PDF

유지놀 처리된 상아질 표면의 상아질 접착제의 전단결합강도에 관한 연구 (SHEAR BOND STRENGTH OF DENTIN BONDING AGENTS ON DENTIN SURFACE TREATED WITH EUGENOL)

  • 유화성;최기운;최경규;박상진
    • Restorative Dentistry and Endodontics
    • /
    • 제25권4호
    • /
    • pp.550-560
    • /
    • 2000
  • In this study, shear bond strength of two bonding systems were measured and appearance of dentin surfaces were observed with SEM according to the storage time of eugenol on dentin surface, thus evaluated the effect of eugenol on bond strength of two dentin bonding systems. Control groups were directly bonded to dentin surface with One Step, Prime & Bond 2.1. Experimental groups were divided into experimental I and II according to dentin bonding agents. After eugenol application, dentin surfaces were bonded with One Step and Prime & Bond 2.1 according to the each storage time of immediately, 3min, 24hour, 48hour and 1week, and then control and experimental groups were filled with light cured composite resin(Z-100). After 24 hours water storage at $37^{\circ}C$, all samples were subjected to a shear load to fracture at a cross head 1.0mm/min with Instron universal testing machine(No. 4467). Etched dentin surface storaged for each time of immediately, 3min, 24hour, 48hour and 1 week after eugenol application were observed under Scanning Electron Microscope(Hitachi S-2300) at 20kvp. The data were evaluated statistically with two-way ANOVA and Tukey's HSD. The results were as follows; 1. Shear bond strengths were higher in control groups than in the experimental groups. 2. As storage time was increased after eugenol application, the shear bond strengths were decreased in experimental groups. 3. In experimental I, II the shear bond strengths were the lowest in which storage time was 1 week after eugenol application. 4. As storage time was increased after eugenol application, etched dentin surfaces showed obstructed dentinal tubule.

  • PDF

견관절의 일과성 하방 아탈구 (Transient Inferior Subluxation of the Shoulder)

  • 태석기;정영복;박근형;송광섭
    • Clinics in Shoulder and Elbow
    • /
    • 제1권2호
    • /
    • pp.167-174
    • /
    • 1998
  • Since the first description by Cotton, there have been sporadic reports about the inferior subluxation of the shoulder. Nevertheless there is still a lack of consensus regarding the mechanism of occurrence, evolution and treatment. We have experienced six cases of inferior sublusation(five cases after trauma and one case after surgery) which resolved over time. Analysis of the clinical informations including serial radiographs, data from clinical examination and electromyography(EMG) revealed the following results. All the five post-traumatic inferior subluxations were noted in women with an average age of 59 years after direct trauma resulting in fracture of the proxiaml hrnerus(4) or clavicle(1), of which nerve injury was proven by EMG in three. One case occurred after Bankart repair by stretch injury to the axillary nerve. The presenting symptom was unusually severe pain on passive motion. Absence of anterior or posterior displacement wasl confirmed by radiographs. All the cases seemed to have delayed onset of subluxation except one. The subluxed hu.meral head was concentrically reduced at an average 11 weeks(range 3-23 weeks) from the supposed time of occurrence and the acromiohumeral interval measUred on the standing anteroposterior radiographs decreased to 9.4 mm ftom 23 mm. Improvement of pain paralled the reduction. In conclusion, the most common cause of transient inferior subluxation was nerve injury in ou~ series and the prognosis was excellent, however protraction of recovery or leaving permanent subluxation would be possible if .the injured nerve is unrecoverable.

  • PDF

텅스텐 중합금의 부피분율, 입자형상에 따른 단열전단밴드 형성 연구 (The Effects of Volume Ratio and Shape on the Formation of Adiabatic Shear Band in WHA)

  • 이승우;송흥섭;문갑태
    • 소성∙가공
    • /
    • 제11권8호
    • /
    • pp.682-690
    • /
    • 2002
  • The formation of adiabatic shearband in tungsten heavy alloys(WHA) was studied in this investigation. Five prismatic specimens were loaded by high velocity impacts and treated as plane strain problems. To find out the effect of particle's volume ratio, specimens containing 81%, 93% and 97% volume percents of tungsten particles were used. Also the effects of particle's geometry and size on the formation of shearband were studied for 81% volume percent alloys by small size particle model, large size particle model and undulated particle models, and the results were discussed.be used to diagnose the causes of necking and fracture in industrial practice and to investigate whether these defects were caused by material property variation, changes in lubrication, or incorrect press settings. In non-axisymmetric deep drawing, three modes of forming regimes are found: draw, stretch, plane strain. The stretch mode for non-axisymmetric deep drawing could be defined when the major and minor strains are positive. The draw mode could be defined when the major strain is positive and minor strain is negative, and plane strain mode could be defined when the major strain is positive and minor strain is zero. Through experiments the draw mode was shown on the wall and flange are one of a drawn cup, while the plane strain and the stretch mode were on the punch head and the punch corner area respectively, We observed that the punch load of elliptical deep drawing was decreased according to increase of die corner radius and the thickness deformation of minor side was more large than major side.