• Title/Summary/Keyword: Head fracture

Search Result 344, Processing Time 0.026 seconds

The Treatment of Gunshot Wound with Maxillofacial Fracture in a Dog

  • Kim, Young-ung;Lee, Dong-bin;Heo, Su-young;Kim, Nam-soo
    • Journal of Veterinary Clinics
    • /
    • v.35 no.5
    • /
    • pp.215-217
    • /
    • 2018
  • A one-year-old, intact male, 24 kg, mixed breed dog was referred to the Animal Medical Center, Iksan, Chonbuk, Korea for treatment of a gunshot wound to the head. Physical examinations revealed bilateral nasal bleeding and open-mouth breathing. Radiographic examination showed fracture of the right maxilla bone and multiple fractures of the nasal bone. A $1cm{\times}1cm{\times}1.8cm$ region of mineral opacity material was observed in the right-cranial ventralnasal cavity and a $6mm{\times}6mm{\times}9mm$ region of mineral opacity material was present in the left-cranial dorsal-nasal cavity. The surgical procedure involved removal of bone fragments and the lodged bullet as well as the installation of three intraosseous wires. At two weeks after surgery, the patient exhibited no complications and had a good prognosis.

Controlled Cooling Technical of High Tensile Valve Spring Wire Rod (고강도 엔진밸브 스프링강 선재 저온조직 발생방지 선재압연 기술)

  • 김경원;장용권;임규환;서일권
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.08a
    • /
    • pp.172-179
    • /
    • 1999
  • As the martensite structure cause fracture failure during drawing from 5.5mm rod to 3.05mm dia. wire without additional heat treatment, the optium cooling condition to inhibit the occurrence of martensite was investigated. In order to get SAE9254+V quality, the effects of alloying element, vanadium on the mechanical properties were investigated. Based upon CCT and TTT curves and the results form cooling test in mill, optimun cooling was found in the condition of the laying head temp of 780$^{\circ}C$ and of the conveyor speed at 0.15m/sec with the whole cover closed. The wire rods produced under the condition showed the best mechanical properties of 120kg/$\textrm{mm}^2$ in TS and 50% in RA, having an excellent drawability. In vanadium added steels, tensile strength was improved without degrading elongation and charpy impact value. That means the strengthening by vanadium is mainly due to the grain refinement by the fine precipitates during tempering process.

  • PDF

Clinical Study of facial bone fracture (악안면 골절에 관한 임상적 고찰)

  • Lee, Ju Whoan;Ro, Hong Sup
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.14 no.1_2
    • /
    • pp.89-96
    • /
    • 1992
  • The purpose of this study was to investigate the fractures of facial skeleton ; mandible, maxilla, zygoma Clinically, we observed 413 patients with facial bone fractures treated at the department of dentistry, Koryo General Hospital from Jan. l989 to Dec. I991. This results ere as follows : 1. The most common fracture was occured in the mandible (63.7%) and the symphysis was occured most freguently(30.4%) 2. The most prevalent age was twenties(37.5%) 3. Main causes was traffic accident(21.7% ) 4. The ratio of male to female was about 9.3 : 1 5. Most combined injuries was head injuries. (54.6%) 6. The most frequent job was a company employee. 7. There were the highest frequency in March, and the lowest frequency in February.

  • PDF

Hemi-spheroidal Punch Stretching Test for Evaluation Press Formability (프레스 가공성 평가를 위한 반타원체 펀치 장출 시험)

  • Lee, Seung-Yeol;Geum, Yeong-Tak
    • Transactions of Materials Processing
    • /
    • v.7 no.6
    • /
    • pp.539-544
    • /
    • 1998
  • Hemi-spheroidal punch stretching test was developed to evaluate the press formability of sheet materials. In the plane strain stretching tests our specially designed hemi-spheroidal head punch were used. In the experiment the circular sheet blanks with parallel edge sides are uniformly stretched up to fracture by raising these punches to assure plane strain stretching deformation along the longitudinal direction of the specimens. The press formability was evaluated by limit punch height(LPH) and minor strain mea-surement around the fracture area. Compared with the hemi-spherical punch and the hemi-cylindrical one our hemi-spheroidal punch was more useful in the experimental reproduction and reliance for press formability test.

  • PDF

Rapid Spontaneous Redistribution of Acute Epidural Hematoma : Case Report and Literature Review

  • Eom, Ki-Seong;Park, Jong-Tae;Kim, Tae-Young;Kim, Jong-Moon
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.2
    • /
    • pp.96-98
    • /
    • 2009
  • Acute epidural hematoma (AEDH) occurring as a result of traumatic head injury constitutes one of the most critical emergencies in neurosurgery. However, there are only several reports that show the rapid disappearance of AEDH without surgical intervention. We suggest redistribution of hematoma through the overlying skull fractures as the mechanism of rapid disappearance of AEDH. A 13-year-old female fell from a height of about 2 m and presented with mild headache. A computed tomography (CT) scan performed 4 hours after the injury revealed an AEDH with an overlying fracture in the right temporal region and acute small hemorrhagic contusion in the left frontal region. A repeat CT scan 16 hours after injury revealed that the AEDH had almost completely disappeared and showed an increase in the epicranial hematoma. The patient was discharged 10 days after injury with no neurological deficits. This case is characterized by the rapid disappearance of an AEDH associated with an overlying skull fracture. We believe that the rapid disappearance of the AEDH is due to the redistribution of the hematoma, rather than its resolution or absorption, and fracture plays a key role in this process.

TWO PART MINI-IMPLANT AS AN EFFICIENT TOOL FOR INTERMAXILLARY FIXATION (분리형 미니 임플란트를 이용한 효과적인 악간고정법의 소개)

  • Lee, Won;Kim, In-Soo;Seo, Woon-Kyung;Heo, Hyun-A;Kim, Seong-Hun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.5
    • /
    • pp.477-482
    • /
    • 2006
  • The new type of orthodontic mini-implant named C-implant can be an effective alternative to conventional one-component mini-implant in the intermaxillary fixation (IMF) cases because of its particular design. The small size, two-part design, efficiency, and low cost of the C-implant make it applicable to various types of IMF cases easily such as fracture reduction and orthognathic surgery. The two part design resists highly to the fracture or deformation during implantation and removal. The long span head allows the patient to easily attach intermaxillary elastics, so that the patient can apply intermaxillary elastics for traction easily. Through this article, we tried to show the possibility of this appliance as a good adjunct for the IMF screw.

A Study on Design Improvement and Strength Evaluation of Shafting System for Washing Machine (드럼세탁기 축계의 설계개선 및 강도평가에 관한 연구)

  • Kim Eui-Soo;Kim Sang-Uk;Kim Byung-Min
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.8 s.185
    • /
    • pp.154-162
    • /
    • 2006
  • By laying its drum horizontally, front-loaded washing machine mostly used in Europe that uses the head of the water to launder was appropriate for washing only small amount of laundry. However, the demands of customers are requiring front-loaded washing machine to handle big capacity laundry as well, and have faster rotation speed to increase drying ability. To meet such demands, more stress from bending and twisting are complexly loaded onto the shaft supporting the horizontal drum, causing problems in fracture strength and fatigue life. Shafting system is mainly divided into flange and shaft. Flange is located between the drum and shaft, transferring power from the shaft to drum, and acting as a supporter of the back of the drum. Shaft is connected from the flange to insert production, transferring power from the motor to drum, and mainly acting as stiffness against the horizontal weight of the shafting system. In this paper, strength analysis and experiment were executed on both the shaft and flange of front-loaded washing machine to suggest the design improvement of shafting system for big capacity, high-rotation drying. Also, verification of this evaluation was executed on fracture strength and fatigue life for studied shaft system.

Coronoidectomy for reduction of superolateral dislocation of mandible condyle

  • Seok, Hyun;Ko, Seung-O;Baek, Jin-A;Leem, Dae-Ho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.48 no.3
    • /
    • pp.182-187
    • /
    • 2022
  • Superolateral dislocation of the condyle is a rare mandibular fracture. The treatment goal is to return the dislocated condyle to its original position to recover normal function. This study reports on superolateral dislocation of the condyle with mandibular body fracture. The mandibular body was completely separated, and the medial pole of the condyle head was fractured. The condyle segment was unstable and easily dislocated after reduction. The temporalis muscle on the condyle segment might have affected the dislocation of the condyle. A coronoidectomy was performed to disrupt the function of the temporalis muscle on the condyle segment in order to successfully reduce the dislocated condyle. Coronoidectomy is a simple procedure with minimal complications. We successfully performed a coronoidectomy to reduce the superolateral displaced condyle to its original position to achieve normal function. Coronoidectomy can be effectively used for reduction of superolaterally displaced condyles combined with severe maxilla-mandibular fractures.

Simple Identification of Symmetric Reduction in Unilateral Depressed Zygomatic Fracture (일측성 광대뼈골절 환자에서 수평계와 자를 이용한 변위 교정의 간단한 파악법)

  • Yi, Hyung-Suk;Lee, Kyung-Suk;Kim, Jun-Sik;Kim, Nam-Gyun
    • Archives of Plastic Surgery
    • /
    • v.37 no.2
    • /
    • pp.195-198
    • /
    • 2010
  • Purpose: The zygoma is a key element which composes the facial contour. Zygomatic fracture induces facial asymmetry. We use radiologic evaluation or inspections mainly for identification of symmetry after reduction depressed zygomatic fracture. But the disadvantages of such methods are time-consuming and complicated process. So we tried to develop a new testing method with a ruler and a level. Methods: In unilateral depressed zygomatic fracture patient, parallel to the patient's head to make sure lay horizontaly. Put the leg of a ruler on the malar eminence so that it is at the same distance from the facial midline. Then take the level of malar eminence as put the level above the ruler. This process was performed before and after the reduction. Results: We were able to fix with plate and screw after checking the results of reduction fast and easily. Good results were obtained at post-operative radiologic evaluation. Conclusion: We can easily get the ruler and level around life. This method is not only simple but also shorttime process compared with other method-radiologic evaluation or inspection. And the operator can explain the results to the patients easily and objectively. Authors obtained the good results with this new method, and would introduce it for another method of identifying the result of reduction in depressed zygomatic fractures.

Clinical Observations of the Chest Trauma (흉부 손상에 대한 임상적 고찰)

  • 최명석
    • Journal of Chest Surgery
    • /
    • v.23 no.5
    • /
    • pp.905-915
    • /
    • 1990
  • A clinical evaluation was performed on 545 cases of the chest trauma those had been admitted and treated at the department of thoracic and cardiovascular surgery in Chosun University Hospital during the past 11 years 5 months period from January 1978 to may 1989. Obtained results were as follows: 1. The ratio of male to female was 3.9: 1 in male predominance, and the majority[66.6%] was distributed from 3rd to 5th decade. 2. Nonpenetrating chest trauma was more common than penetrating about 4.6 times, and the most common cause of the nonpenetrating injuries was traffic accident[241/448, 53.8%] and of the penetrating injuries was stab wound[88/97, 90.7%]. 3. Only 79 cases[14.5%] were arrived to our emergency room within one hour after trauma. 4. The most common lesion due to trauma among these admitted patients was rib fracture[390/545, 71.6%], and the others were lung contusion[217/545, 39.8%], hemothorax[35%], hemopneumothorax[19.6%], and pneumothorax[11.8%] et al in decreasing order. 5. The associated injuries those required special treatment of other departments were 223 cases and its distributions were bone fractures[178/545, 32.7%], head injury[5.3%], and abdominal injury[6.6%]. 6. The others, but interesting chest injuries were follows: sternum fracture[3.1%], diaphragm rupture[2.6%], myocardial laceration and rupture[2 cases], bronchial rupture and laceration[2 cases], and traumatic thymoma rupture[1 case]. 7. The incidence of flail chest was 5.8%a[26/448] in the nonpenetrating injury, and the causes were multiple rib fracture which was in rows more than 4 rib fracture[20 cases], and sternum fracture[6 cases]. 8. We could managed the most of the patient with conservative treatment[43.1%] or closed tube thoracostomy[52.7%], but required emergency open thoracotomy in 64 cases

  • PDF