• Title/Summary/Keyword: Head Part

Search Result 995, Processing Time 0.028 seconds

An Abnormal Breakpoint Data Positioning Method of Wireless Sensor Network Based on Signal Reconstruction

  • Zhijie Liu
    • Journal of Information Processing Systems
    • /
    • v.19 no.3
    • /
    • pp.377-384
    • /
    • 2023
  • The existence of abnormal breakpoint data leads to poor channel balance in wireless sensor networks (WSN). To enhance the communication quality of WSNs, a method for positioning abnormal breakpoint data in WSNs on the basis of signal reconstruction is studied. The WSN signal is collected using compressed sensing theory; the common part of the associated data set is mined by exchanging common information among the cluster head nodes, and the independent parts are updated within each cluster head node. To solve the non-convergence problem in the distributed computing, the approximate term is introduced into the optimization objective function to make the sub-optimization problem strictly convex. And the decompressed sensing signal reconstruction problem is addressed by the alternating direction multiplier method to realize the distributed signal reconstruction of WSNs. Based on the reconstructed WSN signal, the abnormal breakpoint data is located according to the characteristic information of the cross-power spectrum. The proposed method can accurately acquire and reconstruct the signal, reduce the bit error rate during signal transmission, and enhance the communication quality of the experimental object.

Failure simulation of nuclear pressure vessel under severe accident conditions: Part II - Failure modeling and comparison with OLHF experiment

  • Eui-Kyun Park;Jun-Won Park;Yun-Jae Kim;Yukio Takahashi;Kukhee Lim;Eung Soo Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.11
    • /
    • pp.4134-4145
    • /
    • 2023
  • This paper proposes strain-based failure model of A533B1 pressure vessel steel to simulate failure, followed by application to OECD lower head failure (OLHF) test simulation for experimental validation. The proposed strain-based failure model uses simple constant and linear functions based on physical failure modes with the critical strain value determined either using the lower bound of true fracture strain or using the average value of total elongation depending on the temperature. Application to OECD Lower Head Failure (OLHF) tests shows that progressive deformation, failure time and failure location can be well predicted.

Tri-ramification of left external carotid artery associated with anatomical variation of its branches and aneurysm formation

  • Punnapa Raviteja;Mrudula Chandrupatla;Rohini Motwani
    • Anatomy and Cell Biology
    • /
    • v.57 no.2
    • /
    • pp.324-327
    • /
    • 2024
  • Essential sources of arterial vascularisation in the head and neck region are the left and right common carotid arteries (CCA) and their branches. The left CCA (LCCA) originates from the arch of the aorta and the right CCA originates from the brachiocephalic trunk. In this case report, there was a bilateral higher division of CCA at the plane of the greater cornua of the hyoid bone, unilateral tri-ramification of the LCCA and the left external carotid artery (LECA), and the origin of the linguo-facial trunk and the pharyngo-occipital trunk from the LECA. An aneurysm formed in the distal part of LECA before its termination. In this case, we propose a novel categorization called the punnapatla classification for the anatomical variance branching forms of ECA. These kinds of variations are important to the surgeons, and anaesthetists, during the surgeries of the head and neck.

The Early Result of Anterior Rotational Osteotomy in the Treatment of Osteonecrosis of the Femoral Head (대퇴골두 무혈성괴사의 치료에서 전방 회전 절골술의 조기 추시 결과)

  • Kim, Se-Dong;Shin, Duk-Seop;Jang, Woo-Seok
    • Journal of Yeungnam Medical Science
    • /
    • v.11 no.2
    • /
    • pp.284-292
    • /
    • 1994
  • In transtrochanteric rotational osteotomy to treat osteonecrosis of the femoral head, the necrotic superior anterior femoral head is rotated anteriorly around the longitudinal neck axis so that the weight bearing force is transferred to the intact posterior surface. The ratio of transposed intact articular surface of the femoral head to the weight-bearing surface of the acetabulum on postoperative anteroposterior view of the hip roentgenograph is the most important indicator of the prognosis. During the period from December 1992 to June 1994, we treated 31 hips in 28 patients who were indicated for the anterior rotational osteotomy among the patients of osteoncrosis of the femoral head. Among the patients, male were 27 and female was one. Age distribution was from 13 to 62 years old and mean age was 44.3. According to the Ficat and Arlet classification, II A was most in number as 16 II B was 7 and III was 8. As their etiolgic factors, alcohol was most in number as 18, steroid was 3, idiopathic was 5 and trauma was 2. The mean rate of the intact area of the posterior part of the femoral head to the total articular surface on the preoperative lateral view of the hip roentgenograph was 41.8%, The mean ratio of transposed intact articular surface of the femoral head to the weight bearing surface of the acetabulum was 53.8%, Fixation devices were screws or dynamic hip screw.

  • PDF

Clinical Application of Endoscopic Laser Assisted Supraglottic Partial Laryngectomy in Early Supraglottic Cancer (초기 상후두암종에서 레이저를 이용한 내시경하 상후두부분절제술의 적용)

  • Choi Jong-Duck;Kwon Kee-Hwan;Oh Joon-Hwan;Han Seung-Hoon;Lee Seung-Hoon;Choi Geon
    • Korean Journal of Head & Neck Oncology
    • /
    • v.14 no.2
    • /
    • pp.164-168
    • /
    • 1998
  • Background: Supraglottis and glottis have a different embryologic origin. Supraglottic cancer is characterized by high incidence of cervical lymph node metastasis at initial diagnosis, and favored surgical management of the early supraglottic cancer was partial supraglottic laryngectomy, however the procedure resulted in frequent incidences of postsurgical aspiration and voice disabilities. Objectives: We retrospectively analyzed the problems and the advantages of the endoscopic laser assisted supraglottic partial laryngectomy as a part of surgical management for early supraglottic cancer. Materials and Methods: During the past nine years 25 cases of supraglottic cancer(Tl 10 cases, T2 15 cases) were treated by tracheotomy and laser assisted supraglottic partial laryngectomy(KTP532, 15 Watt, continuous type) and in 10 cases with cervical lymph node metastasis, they were additionally managed by neck dissection one week later, and all cases received postoperative irradiation therapy. Results: At present, 19 cases are alive with no evidence of disease. During the follow up period total of six cases(primary failure: three cases, nodal failure: three cases) were recurred. In relation to tumor staging, One of the 10 Tl cases and two of the 15 T2 cases recurred showing 88% locoregional recurrence rate for early supraglottic cancer. Postoperative com-plication included bleeding in three cases who were controlled by electrocautery under general anesthsia, one case of longstanding aspiration and two cases of laryngeal stenosis as a delayed complication. Conclusion: High control rate suggests that the endoscopic laser assisted supraglottic partial laryngectomy may be a good initial management method for early supraglottic cancer, however it is difficult to determine the resection margin, therefore, accurate tumor staging must be done prior to surgery. In order to prepare for postoperative bleeding, edema and aspiration, the tracheotomy must be performed prior to surgery.

  • PDF

Development of a Vegetable Transplanting Robot

  • Kang, Dong-Hyeon;Kim, Dong-Eok;Lee, Gong-In;Kim, You-Ho;Lee, Hye-Jin;Min, Young-Bong
    • Journal of Biosystems Engineering
    • /
    • v.37 no.3
    • /
    • pp.201-208
    • /
    • 2012
  • Purpose: This study was conducted to develop a vegetable transplanting robot which transplants seedlings from a nursery tray to a plant pot using its four fingers. Method: The robot consists of the transplanting part, nursery tray moving part, plant pot moving part, main frame and controller. Two moving parts are controlled by the photo sensor and servo motor. The transplanting part was composed with two components; transporting device using E-MY2H(SMC Corp., Japan) for controlling finger position accurately and finger for transplanting the seedling. Results: Head lettuce using the transplanting robot was transplanted in 21 days after sowing based upon the seed shape measurement and removing examination. The optimal finger shape was thin pin type because it caused minimum damage to the roots of seedlings. Conclusions: The four inclined pin type was applied to remove the seedlings from the nursery tray. In addition, the transplanting capacity of the developed robot was 2800 pots per hour and the rate of success was 99% and above.

Development of OHS System Driven by Linear Motor for Automatic Transfer of LCD Panels (선형전동기를 적용한 LCD 패널 자동반송용 순환궤도차량 시스템 개발)

  • Kim, Won-Gon;Yun, Jong-Bo;Park, Gun-Woo;Hwang, Gye-Ho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.7 no.3
    • /
    • pp.11-16
    • /
    • 2008
  • The authors investigated an overhead shuttle (OHS) system for automatic transferring the liquid crystal display (LCD) panels. The constructed tracks of OHS system include the linear and curve regions and have been installed on the ceiling to transfer the cassette of LCD glass along the closed-loop and open-loop tracks. In this study, the OHS system was implemented by a proposed linear motor to solve encoder installation and the system cost problems of the long distance transfer system. In addition, we utilized a new algorithm of the position detection and a new control algorithm for driving linear motor. The newly developed control algorithm was demonstrated from both a computer simulation and an experimentation, indicating that the highly reliable and speedy transfer system can enhance the LCD panel productivity of commercial OHS system.

  • PDF

A Study of Skin Resistance Variability of POF Patients by Autonomic Bioelectric Response Recorder (Centering around 1-3 Parts) (생체전기자율반응 측정기를 이용한 조기난소부전증 환자의 피부저항변이도 연구 (1, 2, 3 상한 중심으로))

  • Choi, Eun-Mi;Kang, Myung-Ja;Wee, Hyo-Sun
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.19 no.3
    • /
    • pp.247-256
    • /
    • 2006
  • Purpose : To research the Skin Resistance Variability(SRV) of premature ovarian failure(POF) patients by Autonomic Bioelectric Response Recorder(ABR-2000 system, Meridian, Korea) and report the specific results in SRV of POF patients. Methods : We measured SRV of 17 POF Patients who came to Conmaul Oriental Medical Hospital during August 2005 ${\sim}$ July 2006 by ABR-2000 system. We analyzed the results which height of graph Part was converted into 0${\sim}$10, and the readings of Low/Normal/High. Results : The mean value of graph height on each(1, 2, 3) part is lower than normal range(4-6) in POF patients. The distribution ratio of Low/Normal/High on each(1, 2, 3) part shows that there are much more Low proportion in POF patients. Conclusion : The low graph height of POF patients on 1, 2, 3 part means that conductivity & capacitance of POF patients is low, especially on head.

  • PDF

Manufacturing of Ag Nano-particle Ink-jet Printer and the Application into Metal Interconnection Process of Si Solar Cells (Si 태양전지 금속배선 공정을 위한 나노 Ag 잉크젯 프린터 제작 및 응용)

  • Lee, Jung-Tack;Choi, Jae-Ho;Kim, Ki-Wan;Shin, Myoung-Sun;Kim, Keun-Joo
    • Journal of the Semiconductor & Display Technology
    • /
    • v.10 no.2
    • /
    • pp.73-81
    • /
    • 2011
  • We manufactured the inkjet printing system for the application into the nano Ag finger line interconnection process in Si solar cells. The home-made inkjet printer consists of motion part for XY motion stage with optical table, head part, power and control part in the rack box with pump, and ink supply part for the connection of pump-tube-sub ink tanknozzle. The ink jet printing system has been used to conduct the interconnection process of finger lines on Si solar cell. The nano ink includes the 50 nm-diameter. Ag nano particles and the viscosity is 14.4 cP at $22^{\circ}C$. After processing of inkjet printing on the finger lines of Si solar cell, the nano particles were measured by scanning electron microscope. After the heat treatment at $850^{\circ}C$, the finger lines showed the smooth surface morphology without micropores.

Study on the Design of the Patient's Clothes for a disabled Child (기동부자유(起動不自由) 아동(兒童)을 위한 환자복(患者服) 디자인)

  • Nam, Yoon-Sook;Shin, Myung-Jin
    • Journal of Fashion Business
    • /
    • v.9 no.1
    • /
    • pp.79-88
    • /
    • 2005
  • The purpose of this study is to propose the design of the patient's clothes for a disabled child between 4 and 6. For this, in this study, I would present the following design plan which includes 3 upper garments, 2 trousers and a one-piece dress. In case of the damage on head and neck, a neck line should be deep and wide thereby providing ease to the clothes. To facilitate injection and dressing/undressing, there should be parting from neck to cuff which can be fixed by snap or button. By rolling up sleeves with strings inside the cuffs and fixating plaster cast with snap button outside the cuffs. In case of body cast with plaster cast around body part, front adjusting part should be wider and the width should be adjusted with strings. In case of hip spica cast which covers waist, I separated front part and rear part, fixated them with snap buttons, gave more width to front adjusting part with strings to adjust width, which constitute one-piece dress. In case of shoulder spica cast, the other shoulder which is not covered with plaster cast should be exposed, and to prevent clothes' coming down, strings with snap button or velcro should be attached over a shoulder so that the length of the strings can be adjusted. In case of applying plaster cast or aid to the whole part of a leg, one part of trousers should be shorter so as to expose the injured part and there should be a parting with strings or velcros on the side for easy dressing/undressing. When plaster cast or splint is short, The strings are meant to adjust length of trousers. The partings are located 2 cm from side lines toward the center.