• Title/Summary/Keyword: Head Part

Search Result 994, Processing Time 0.029 seconds

Distributions of Hydrogeological Variables and Flow Field on GIS Digital Map (GIS 수치지도를 이용한 수리지질학적 변수와 지하수 유동의 분포)

  • Lee, Cheo K.
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.2 no.2
    • /
    • pp.45-58
    • /
    • 1999
  • Digital map is utilized for an effective display of the distributions of the hydrogeological variables such as water table height(hydraulic head) and log-transmissivity(lnT) in north Pohang, KyungBug. Specifically the geostatistical method kriging is used to construct the distributions in an unconfined aquifer from a finite set of measured data. The experimental variograms for both the head and lnT suggest spherical models with nugget of 0 and range of 6km. The kriged results by using these variograms show that the head decreases primarily from the west to the east with a large peak in the north-western part and lnT is at the maximum level in the central part with outwardly decreasing trend. The constructed delineation is also used to calculate the flow field in the region. Finite differences with second order consistency are used to calculate the fluxes in the east(x) and north(y) across a vertical cross-section of unit width and height equal to the thickness of the wet zone in the aquifer. It is demonstrated that the flow is dominantly in the east with diverging trend on the eastern hillside of the water table peak. A few convergent spots also appear.

  • PDF

Induction of Local and General Analgesia by Electroacupuncture in Dogs (개에 있어서 침술에 의한 국소 및 전신마취에 관한 연구)

  • 남치주;서강문
    • Journal of Veterinary Clinics
    • /
    • v.14 no.2
    • /
    • pp.244-253
    • /
    • 1997
  • This study was performed to evaluate the possibility of inducing analgesia by electroacupuncture stimulation at single acupoint or combined acupoints and to examine the analgesic effects following the combination of premedication and electroacupunrture analgesia(EA). Analgesia was induced by EA with the current of 1-4 volts and the frequency of 10-45 Hz to the acupoints Uown to be related to analgesia on the head/necIL axial part thoracic and pelvic limb. In Yi Feng acupoint of head/neck part pain responses were not disappeared after electroacupunrture stimulation to the head/necIL thoracic limbo thoraxl abdomen, loin, rear and pelvic limb. Pain responses were remained after EA of Tian Men-Tian Ping and Shen Yu arupoints of axial park whereas hypoalgesia was observed after EA of Tian Ping-Bai Hui acupoint in all parts of body. There was no analgesic effects after EA stimulation of the brachial plexus and Wai Kuan acupoint, whereas after EA stimulation of San Yang Lo, pain responses were disappeared in headfnecll, thoracic limb and pelvic limbo and in the other parts of body hypoalgesia was shown. In EA stimulation of Tsu San Li acupoint pain responses were disappeared in pelvic limb and in San Yin Chiao acupoint pain responses were disappeared in head/necIL thoracic and pelvic limb, and hypoalgesia was shown in abdomen. On the combination of San Yang Lo Pli Men) and San Yin Chiao (Pu Yan6 acupoints, pain response in heauneck was decreased in 5 minutes, whereas analgesia in thoracic and pelvic limb was induced after 20-30 minutes and in abdomen was noted after 50 minutes. The more frequrncy was increased, the more rapid analgesic e11%t was induced. The analgesic effects wert not good in laparotomy under EA at the combination of San Yang Lo (Xi Men) and San Yin Chiao (Pu Yang) arufoints. Enteroanastomosis could not be continued under acrpromazine, xylazine and diazepam with EA. However, under EA followed by tiletaminetzolazepam, the operation could be completed without additional anesthesia and the analgesic effects were good. There were no changes in clinical signs, hematological and serological values after combination of the premeditation of tiletamine+zolaEepam and EA. It is considered that EA alone is not suitable for the main surgery, but the combination method of EA and sedatives can be utilized in practice.

  • PDF

A Study on the Body Surface Area of Korean Women (Part I) Body Surface Area and It's Rational Rate (한국여성의 체표면적에 관한 연구(제1보) -체포면적 및 그의 안분비율에 대하여-)

  • Im Soon;Cha Ok Seon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.12 no.3 s.28
    • /
    • pp.277-284
    • /
    • 1988
  • The purpose of study was to measure to body Surface area and the rational rate of Korean adult's women. The subjects are 20 years old to 49 years old women (Their bust width ranges from 74.5 to 101.5 cm, the height from 144.6 to 163.3 cm, the weight from 44.2 to 74.0 kg, Rohrer Index from 1. 02 to 1. 89). As the experimental method, both the gypsum method, by which the shape of body can be copied as it is, and weighing method, from which planed body surface area can be measured with consistant thickness of polypropylene film used. The results were obtained as follows. 1. After dividing the Korean adult's women into four groups (single and married women in their twenties, those in their thirties, those in their fourties). The change of body surface area was reviewed in accordance with age groups. No great difference among age group was showed in whole body surface area. 2. average value of body surface area is 1, 514m^2 and the part of trunk shows the biggest difference to the age groups. 3. After dividing the middle of body into two groups, the relation of symmetry of each parts is reviewed with difference in body surface area. The results shows that the part of head & neck and lower limbs are symmetrical. The part of trunk and upper limbs are unsymmetrical. 4. Regional rates of each part of whole body surface area are follows. head $4.98\%$, each-lobes $0.46\%$, neck $2.01\%$, face$2.48\%$, upper trunk $19.64\%$, lower trunk $13.91\%$, upper armpits $1.76\%$, lower armpits $12.52\%$, hands $4.64\%$, thighs $18.89\%$, lower legs$13.10\%$, feet $6.01\%$.

  • PDF

Unexpected Lymph Node Pathology in Neck Dissection for Head and Neck Cancer (두경부 종양환자에서 경부 림프절의 예기치 않은 병리적 소견)

  • Oh Kyung-Kyoon;Lee Guk-Haeng;Lim Sang-Moo;Shim Yoon-Sang
    • Korean Journal of Head & Neck Oncology
    • /
    • v.10 no.1
    • /
    • pp.3-6
    • /
    • 1994
  • Neck dissection has become an integral part of the staging and management of head and neck tumors. This paper reports a series of head and neck patients who had pathological findings in their neck dissection specimens, which were unrelated to their primary tumors. In 7 cases, there was unexpected pathology in the cervical lymph nodes which was not related to the primary tumor. Four cases were squamous cell carcinomas and 3 were thyroid carcinomas. In 3 cases of squamous cell carcinomas, there were no evidence of metastatic squamous cell carcinoma in neck dissection specimen; however, the lymph nodes were found to be involved by metastatic papillary carcinoma in one larynx cancer, metastatic adenocarcinoma in the other larynx cancer, tuberculosis in one nasopharynx cancer. In three of neck dissection specimen of carcinoma(two thyroid carcinomas, one laryngeal carcinoma), dual nodal pathology was found: Each of these specimen contained carcinoma with tuberculosis of the lymph nodes in three cases. In one thyroid carcinoma, there was no evidence of metastasis; however, the lymph nodes were found to be involved by tuberculosis. Preoperative assessment did not reveal any findings to alert us to the possibility of a synchronous pathological process in the cervical nodes of this group of 7 patients. In particular, there was no evidence of active pulmonary tuberculosis in the 5 patients with active lymph node disease.

  • PDF

The solid angle estimation of acetabular coverage of the femoral head using 3D method (입체각 측정을 통한 대퇴골두에 대한 관골구 coverage 측정)

  • Choi, K.H.;Kim, M.C.;Lim, C.T.;Kim, S.I.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.123-126
    • /
    • 1997
  • We present a method for the estimation of 3D solid angle assessment of the acetabular coverage of the femoral head in 3D space. At first, femoral head and acetabulum is segmented from the original CT scan images. The slice thickness is 1.5mm and the number of slices is usually 30-40 to cover the entire acetabulum. The superior half of the femoral head is modeled as part of a sphere. Thus, the axial cross sections of the upper half of the femoral head are also modeled as circles. A set of points from each outline image of femoral head is fitted recursively into a circle by minimizing root-mean-square (RMS) error. With these fitted circles, a center point of the femoral head model is evaluated. This is a reference point for calculating the solid angle of the acetabular inner surface. Next, the tangent lines connecting from a set of points of the acetabular edge to the center of the fitted sphere are obtained. The lines pass through the unit sphere whose center is the same as that of the femoral head. With the points on the unit sphere, we calculate area and estimate the solid angle. Based on this solid angle, the deformity of the acetabulum is analyzed. In case of normal subject, the solid angle is about 4.3 (rad) and acetabular coverage is 68%.

  • PDF

A Study of Power Absorption in Human Head Exposed to Plane Wave (평면파에 노출된 인체 두부의 전력흡수 해석)

  • 이애경;조광윤;이혁재
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.8 no.6
    • /
    • pp.665-680
    • /
    • 1997
  • The specific absorption rate (SAR) distributions in various models of the human head have been analyzed when the models are exposed to 350 MHz and 900 MHz plane waves. The numerical analysis is performed with the finite-difference time-domain (FDTD) method. A homogeneous sphere including a cylinderical neck, a homogeneous head shaped model, and a heterogeneous realistic model are used as models of human head. The incident plane wave used for these calculations is propagating from the front to the back or from the back to the front of the head model, with its E-field vector orientation being parallel to the major length of the body. The specific findings are: 1) the average SARs of the three models are similar mutually but the local SARs of them differ greatly mutually; 2) the power is deposed more deeply in the head at 350 MHz, which is roughly the resonant frequency of a human head, than at 900 MHz; 3) for a plane wave propagating from the back, "hot spot" is found in the neck region, not in the head; 4) for a plane wave propagating from the front, "hot spot" is found in the nose at 900 MHz, and in the upper part of the lip and the jaw region at 350 MHz.

  • PDF

Development on Human Muscle Skeletal Model and Stress Analysis of Kumdo Head Hitting Motion (검도 머리치기 동작의 인체 근골격 모델개발 및 응력해석)

  • Lee, Jung-Hyun;Lee, Se-Hoon;Lee, Young-Shin
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.11
    • /
    • pp.116-125
    • /
    • 2007
  • Human muscle skeletal model was developed for biomechanical study. The human model was consists with 19 bone-skeleton and 122 muscles. Muscle number of upper limb, trunk and lower limb part are 28, 60, 34 respectively. Bone was modeled with 3D beam element and muscle was modeled with spar element. For upper limb muscle modelling, rectus abdominis, trapezius, deltoideus, biceps brachii, triceps brachii muscle and other main muscles were considered. Lower limb muscle was modeled with gastrocenemius, gluteus maximus, gluteus medius and related muscles. The biomechanical stress and strain analysis of human was conducted by proposed finite element analysis model under Kumdo head hitting motion. In this study structural analysis has been performed in order to investigate the human body impact by Kumdo head hitting motion. As the results, the analytical displacement, stress and strain of human body are presented.

The Tectonic Characteristics of ′KAN′ in the head residence of Uisong Kims (의성 김씨종택에 있어서 간의 건축적 특성)

  • 장선주;이강훈
    • Journal of the Korean housing association
    • /
    • v.15 no.3
    • /
    • pp.11-19
    • /
    • 2004
  • The purpose of this study is to explain the tectonic characteristics of 'Kan' which is an unit of composition in the head residence of Uisong Kims. Here, the 'Kan' is assumed as a conceptual framework to organize a house and also a maneuvering tool to control the spatial order with relationship between the whole and the part. Not limited to the simple conceptual aspects, but the interrelated elements such as the site conditions, modules, functions, structure and aesthetic factors. Through the process of the study, the role of 'Kan' is proved to be a tectonic tool for self-regulating architectural order by relation matrix of elements. 'Kan' is not only a fixed measuring tool for functions and material of a house but also a flexible device to control the building composition. 'Kan' is certainly a relative subject for measurement of form, space and aesthetic quality.

Vehicle-induced aerodynamic loads on highway sound barriers part1: field experiment

  • Wang, Dalei;Wang, Benjin;Chen, Airong
    • Wind and Structures
    • /
    • v.17 no.4
    • /
    • pp.435-449
    • /
    • 2013
  • The vehicle-induced aerodynamic loads bring vibrations to some of the highway sound barriers, for they are designed in consideration of natural wind loads only. A field experiment is carried out with respect to three important factors: vehicle type, vehicle speed and the vehicle-barrier separation distance. Based on the results, the time-history of pressures is given, showing identical characteristics in all cases. Therefore, the vehicle-induced aerodynamic loads acting on the highway sound barrier are summarized as the combination of "head impact" and "wake impact". The head impact appears to have potential features, while the wake impact is influenced by the rotational flow. Then parameters in the experiment are analyzed, showing that the head impact varies with vehicle speed, vehicle-barrier separation distance, vehicle shape and cross-sectional area, while the wake impact is mainly about vehicle-barrier separation distance and vehicle length.

Accessory head of flexor pollicis longus in Jeju islander cadavers

  • Yu, Jae Ma;Yoon, Sang Pil;Kim, Jinu
    • Journal of Medicine and Life Science
    • /
    • v.15 no.1
    • /
    • pp.16-18
    • /
    • 2018
  • Anterior interosseous nerve palsy is known to occur uncommonly because of its compression by the accessory head of flexor pollicis longus(AHFPL) in the forearm. During routine educational dissection, we found 7 AHFPLs in 12 upper limbs of 6 adults Korean Jeju islander cadavers, which inserted onto flexor pollicis longus. Three AHFPLs of them arose from coronoid process of the ulna, and the others arose independently from the flexor digitorum superficialis (FDS). Using the topographical relationship of the anterior interosseous nerve to the AHFPL, all anterior interosseous nerve was crossed the tendinous part of the AHFPL. This study has shown that there are discrepancies in the origin of AHFPL and the location of the anterior interosseous nerve in Koreans, which is supposed to be related to unique genetic pool in Jeju Island.