• Title/Summary/Keyword: Head & neck cancer

Search Result 1,144, Processing Time 0.024 seconds

THE RELATIONSHIP OF P63 EXPRESSION WITH CELL PROLIFERATION AND APOPTOSIS IN DMBA-INDUCED HAMSTER BUCCAL POUCH CARCINOGENESIS (DMBA 유도 햄스터 협낭 발암모델에서 세포증식 및 사멸과 p63 발현의 관계 분석)

  • Park, Jee-Hyun;Lee, Won-Deok;Min, Chul-Gi;Kang, Jin-Han;Myung, Hoon;Lee, Jong-Ho;Kim, Myung-Jin
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.3
    • /
    • pp.219-227
    • /
    • 2005
  • Purpose: Abnormalities in the p53 gene are regarded as the most consistent genetic abnormalities detected in head and neck squamous cell carcinogenesis. Two new members of the p53 gene family, p73 and p63 have recently been identified. They share considerable sequence homology with p53 in the transactivation, DNA binding, and oligomerization domains, indicating possible involvement in carcinogenesis. Disruption of the homeostatic balance between proliferation and apoptosis is widely believed to contribute to human oral carcinogenesis. The aim of this study was to analyze expression of p63 in squamous cell carcinogenesis and to compare with immunochemical markers representing cell proliferation and apoptosis. Materials and Methods: Using the Syrian hamster oral cancer model, the fraction of apoptotic (apoptotic index-AI), proliferating (mitotic index-MI) and p63 expressing keratinocytes were examined at normal, dysplastic and malignant oral epithelium using the TUNEL assay, PCNA and p63 immunostaining. Results: p63 significantly increased between normal and dysplastic epithelium and between dysplastic and malignant epithelium. PCNA significantly increased between normal and dysplastic epithelium and between normal and malignant epithelium. However, increase between dysplastic and malignant epithelium, though still increasing, was not statistically significant. The percentage of TUNEL positive cells increased from normal to dysplastic epithelium and returned to normal keratinocyte level in the malignant epithelium. However, differences between tissue types were not significant. The ratio of MI:AI increased significantly only in the dysplastic-malignant epithelial transition. The increase of p63 expression closely reflected the change in the MI:AI ratio during oral carcinogenesis. Conclusion: The p63 may be associated with the regulation of epithelial proliferation and apoptosis in DMBA-induced hamster buccal pouch squamous cell carcinogenesis. Further study is required to investigate which p63 isoforms are involved in hamster buccal pouch carcinogenesis.

A Preliminary Study of Virtual-micro Intensity Modulated Radiation Therapy (가상 미세 세기조절방사선치료(Virtual micro-IMRT;VMIMRT) 기법의 임상 적용을 위한 예비적 연구)

  • 김상노;조병철;서택석;배훈식;최보영;이형구
    • Progress in Medical Physics
    • /
    • v.13 no.1
    • /
    • pp.32-36
    • /
    • 2002
  • For Intensity Modulated Radiation Therapy(IMRT), the spatial resolution of intensity map(IM) is limited by the width of multi-leaf collimator, which would make an effect on the conformity of the target, as well as organs at risk. Several Methods are suggested to increase the spatial resolution, which can be categorized by the hardware-dependent technique and the software-based technique. However the best solution might be to make the width of MLC finer. it has several obstacles in the respects of technical difficulty and cost. This preliminary study is designed to investigate the clinical effectiveness of the virtual-micro IMRT(VMIMRT) technique, one of the software-based technique. A particular intensity map was created, which has 42$\times$54 pixel dimension ,0.5cm pixel size and 15 intensity levels. Using this intensity map, segment fields of IMRT were generated with 1$\times$lcm, 0.5$\times$1cm, 0.5$\times$0.5cm(VMIM) beamlet size, respectively As results, we found that there was no evidence of improvement for VMIMRT, compared with the 0.5$\times$lcm beamlet size which can be delivered by 1cm width MLC. The reason seems to be due to the constraint of VMIMRT. Further study is required to prove the benefit of the VIMRT in clinical case like head and neck cancer, where is expected that higher resolution than 1cm is necessary.

  • PDF

Expression of Sodium-Iodide Symporter (NIS) in Thyroid Nodules: Comparison of RT-PCR and Immunohistochemical Staining Methods (갑상선 결절에서 Sodium Iodide Symporter (NIS)의 발현: RT-PCR방법과 면역조직화학염색법의 비교)

  • Bae, Sang-Kyun;Lee, Kang-Dae;Chang, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.6
    • /
    • pp.511-515
    • /
    • 2004
  • Purpose: The sodium-iodide symporter (NIS) expression is an important factor in determining the sensitivity of radioiodine therapy in well-differentiated thyroid cancers. Several previous studies for the expression of NIS in thyroid tissues show diverse results. To investigate whether there is difference between methods in determining the expression of NIS in thyroid tissues of patients with thyroid nodules, we measured the expression ot NIS using two different methods (RT-PCR and immunoshistochemical staining) and compared the results. Materials & Methods: We measured the expression of NIS by reverse transcriptase-polymerase chain reaction (RT-PCR) and also by immunohistochemical staining using anti-NIS antibody in thyroid cancers and other benign thyroid diseases. We compared the results of each method. We included 19 papillary carcinomas, 1 follicular carcinoma, 7 medullary carcinoma, 4 adenomas and 7 nodular hyperplasias. Results: By RT-PCR analysis, 10 of 19 papillary carcinomas expressed NIS, but 1 follicular cancer didn't express NIS. By immunohistochemical staining, 15 of 19 papaillary carcinomas express NIS, but 1 follicular lancer didn't express NIS. There was a significant correlation between the semiquautitative results of RT-PCR and immunohistochemical staining of NIS expression. (p<0.01) Conclusion: Our data demonstrated that the expression of NIS in thyroid cancers and other benign diseases investigated by RT-PCR and immunohistochemical staining correlated well each other. However, by immunohistochemical staining, more NIS expression was found.

Mitochondrial DNA Mutation (3243A→G,1555A→4G,7445A→G) in Noise-Induced (소음성 난청에서의 Mitochondrial DNA A3243G, A1555G, A7445G 돌연변이)

  • Hong Young-Seoub;Nishio Hisahide;Lee Myeong-Jin;Kwak Ki-Young;Hwang Chan-Ho;Shin Dong-Hoon;Kwak Jong-Young;Lee Yong-Hwan;Kim Jong-Min;Kim Joon-Youn
    • Journal of Life Science
    • /
    • v.14 no.6 s.67
    • /
    • pp.913-919
    • /
    • 2004
  • Mitochondrial DNA mutations have been reported in recent years in association with sensorineural hering loss. The purpose of this study is to identify the association between the noise-induced sensorineural hearing loss and the A to G mutation at nucleotide 3243, 1555, 7445 of mitochondrial DNA. Study subjects were established by history and chart review, and audiological and clinical data were obtained. Blood was sampled from 214 normal controls, 102 noise-induced hearing loss, and 28 sensorineural hearing loss. The DNA of these individuals were extracted, and mitochondrial DNA fragments were analyzed by polymerase chain reaction. Subsequently, the coding sequence of mitochondrial DNA 3243, 1555, 7445 were sequenced, and compared to the normal sequence, and all sequence variations were analyzed by restriction enzymes. Mitochondrial DNA mutations $(3243A{\rightarrow}G,\;1555A{\rightarrow}4G,\;7445A{\rightarrow}G)$ were not detected by polymerase chain reactions in any patients with noise-induced hearing loss, sensorineural hearing loss, and normal controls. The DNA sequencing of PCR products did not revealed an A to G substitution at nucleotide 3243, 1555, 7445 of mitochondrial DNA. The noise-induced sensorineural hearing loss was not associated with mitochondrial DNA mutation $(3243A{\rightarrow}G,\;1555A{\rightarrow}4G,\;7445A{\rightarrow}G)$.

Evaluation of Skin Dose and Image Quality on Cone Beam Computed Tomography (콘빔CT 촬영 시 mAs의 변화에 따른 피부선량과 영상 품질에 관한 평가)

  • Ahn, Jong-Ho;Hong, Chae-Seon;Kim, Jin-Man;Jang, Jun-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.17-23
    • /
    • 2008
  • Purpose: Cone-beam CT using linear accelerator attached to on-board imager is a image guided therapy equipment. Because it is to check the patient's set-up error, correction, organ and target movement. but imaging dose should be cause of the secondary cancer when taking a image. The aim of this study is investigation of appropriate cone beam CT scan mode to compare and estimate the image quality and skin dose. Materials and Methods: Measurement by Thermoluminescence dosimeter (TLD-100, Harshaw) with using the Rando phantom are placed on each eight sites in seperately H&N, thoracic, abdominal section. each 4 methods of scan modes of are measured the for skin dose in three time. Subsequently, obtained average value. Following image quality QA protocol of equipment manufacturers using the catphan 504 phantom, image quality of each scan mode is compared and analyzed. Results: The results of the measured skin dose are described in here. The skin dose of Head & Neck are measured mode A: 8.96 cGy, mode B: 4.59 cGy, mode C: 3.46 cGy mode D: 1.76 cGy and thoracic mode A: 9.42 cGy, mode B: 4.58 cGy, mode C: 3.65 cGy, mode D: 1.85 cGy, and abdominal mode A: 9.97 cGy, mode B: 5.12 cGy, mode C: 4.03 cGy, mode D: 2.21 cGy. Approximately, dose of mode B are reduced 50%, mode C are reduced 60%, mode D are reduced 80% a point of reference dose of mode A. the results of analyzed HU reproducibility, low contrast resolution, spatial resolution (high contrast resolution), HU uniformity in evaluation item of image quality are within the tolerance value by recommended equipment manufacturer in all scan mode. Conclusion: Maintaining the image quality as well as reducing the image dose are very important in cone beam CT. In the result of this study, we are considered when to take mode A when interested in soft tissue. And we are considered to take mode D when interested in bone scan and we are considered to take mode B, C when standard scan. Increasing secondary cancer risk due to cone beam CT scan should be reduced by low mAs technique.

  • PDF

Research of 6 MeV Electron Dose Distribution (6 MeV Electron Therapy에서의 Electron Dose Distribution에 관한 연구)

  • Je Jae-Yong;Park Chul-Woo;Jin Sung-Jin;Park Eun-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.161-166
    • /
    • 2005
  • Purpose : Electron is used for the treatment of skin cancer, breast cancer, and head and neck cancer in clinic. Our study is performed to check the isodose distribution in source surface distance(SSD)and source bolus distance(SBD)setup, nipple influence to isodose distribution of electron, junctional area isodose variation of photon and electron field. Materials and Methods : The electron dose distribution measures the diameter for 20 cm hemisphere paraffin phantom 2 made. It inserted the film between 2 paraffin phantom and it investigated it got radiation and dose distribution curve. Results : The 8% of isodose difference is with the surface distance(SSD)and source bolus distance(SBD)setup. The electon when the nipple exists inside the field, as nipple size it cuts the bolus and when it puts out and there is a possibility of getting the dose distribution which is homogeneous. When in the junction of electron and photon it uses the bolus it uses in the electron field whole, there is a possibility of getting the dose distribution which is homogeneous. Conclusion : The dose distribution decrease from the SBD setup. To reduce the influence of nipple, corresponding volume of bolus should be removed. And bolus covering all the electron field reduced hot and cold spot of junctional area of photon. In the future becomes the research which sees an effective electron therapy.

  • PDF

The Evaluation and Development of Head and Neck Radiation Protective Device for Chest Radiography in 10 Years Children (소아(10세) 흉부 방사선촬영에서의 두경부 방사선 방어기구 개발 및 평가)

  • Lee, Jun Ho;Lim, Hyun Soo;Lee, Seung Yeol
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.2
    • /
    • pp.118-123
    • /
    • 2015
  • The frequency of diagnostic radiation examinations in medical institutions has recently increased to 220 million cases in 2011, and the annual exposure dose per capita was 1.4 mSv, 51% and 35% respectively, compared to those in 2007. The number of chest radiography was found to be 27.59% of them, the highest frequency of normal radiography. In this study, we developed a shielding device to minimize radiation exposure by shielding areas of the body which are unnecessary for image interpretation, during the chest radiography. And in order to verify its usefulness, we also measured the difference in entrance surface dose (ESD) and the absorbed dose, before and after using the device, by using an international standard pediatric (10 years) phantom and a glass dosimeter. In addition, we calculated the effective dose by using a Monte Carlo simulation-based program (PCXMC 2.0.1) and evaluated the reduction ratio indirectly by comparing lifetime attributable risk of cancer incidence (LAR). When using the protective device, the ESD decreased by 86.36% on average, nasal cavity $0.55{\mu}Sv$ (74.06%), thyroid $1.43{\mu}Sv$ (95.15%), oesophagus $6.35{\mu}Sv$ (78.42%) respectively, and the depth dose decreased by 72.30% on average, the cervical spine(upper spine) $1.23{\mu}Sv$ (89.73%), salivary gland $0.5{\mu}Sv$ (92.31%), oesophagus $3.85{\mu}Sv$ (59.39%), thyroid $2.02{\mu}Sv$ (73.53%), thoracic vertebrae(middle spine) $5.68{\mu}Sv$ (54.01%) respectively, so that we could verify the usefulness of the shielding mechanism. In addition, the effective dose decreased by 11.76% from $8.33{\mu}Sv$ to $7.35{\mu}Sv$ before and after wearing the device, and in LAR assessment, we found that thyroid cancer decreased to male 0.14 people (95.12%) and female 0.77 people (95.16%) per one million 10-year old children, and general cancers decreased to male 0.14 people (11.70%) and female 0.25 people (11.70%). Although diagnostic radiation examinations are necessary for healthcare such as the treatment of diseases, based on the ALARA concept, we should strive to optimize medical radiation by using this shielding device actively in the areas of the body unnecessary for the diagnosis.

Dosimetric evaluation of using in-house BoS Frame Fixation Tool for the Head and Neck Cancer Patient (두경부암 환자의 양성자 치료 시 사용하는 자체 제작한 BoS Frame 고정장치의 선량학적 유용성 평가)

  • Kim, kwang suk;Jo, kwang hyun;Choi, byeon ki
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.28 no.1
    • /
    • pp.35-46
    • /
    • 2016
  • Purpose : BoS(Base of Skull) Frame, the fixation tool which is used for the proton of brain cancer increases the lateral penumbra by increasing the airgap (the distance between patient and beam jet), due to the collision of the beam of the posterior oblique direction. Thus, we manufactured the fixation tool per se for improving the limits of BoS frame, and we'd like to evaluate the utility of the manufactured fixation tool throughout this study. Materials and Methods : We've selected the 3 patients of brain cancer who have received the proton therapy from our hospital, and also selected the 6 beam angles; for this, we've selected the beam angle of the posterior oblique direction. We' ve measured the planned BoS frame and the distance of Snout for each beam which are planned for the treatment of the patient using the BoS frame. After this, we've proceeded with the set-up that is above the location which was recommended by the manufacturer of the BoS frame, at the same beam angle of the same patient, by using our in-house Bos frame fixation tool. The set-up was above 21 cm toward the superior direction, compared to the situation when the BoS frame was only used with the basic couch. After that, we've stacked the snout to the BoS frame as much as possible, and measured the distance of snout. We've also measured the airgap, based on the gap of that snout distance; and we've proceeded the normalization based on each dose (100% of each dose), after that, we've conducted the comparative analysis of lateral penumbra. Moreover, we've established the treatment plan according to the changed airgap which has been transformed to the Raystation 5.0 proton therapy planning system, and we've conducted the comparative analysis of DVH(Dose Volume Histogram). Results : When comparing the result before using the in-house Bos frame fixation tool which was manufactured for each beam angle with the result after using the fixation tool, we could figure out that airgap than when not used in accordance with the use of the in-house Bos frame fixation tool was reduced by 5.4 cm ~ 15.4 cm, respectively angle. The reduced snout distance means the airgap. Lateral Penumbra could reduce left, right, 0.1 cm ~ 0.4 cm by an angle in accordance with decreasing the airgap while using each beam angle in-house Bos frame fixation tool. Due to the reduced lateral penumbra, Lt.eyeball, Lt.lens, Lt. hippocampus, Lt. cochlea, Rt. eyeball, Rt. lens, Rt. cochlea, Rt. hippocampus, stem that can be seen that the dose is decreased by 0 CGE ~ 4.4 CGE. Conclusion : It was possible to reduced the airgap by using our in-house Bos frame fixation tool for the proton therapy; as a result, it was possible to figure out that the lateral penumbra reduced. Moreover, it was also possible to check through the comparative analysis of the treatment plan that when we reduce the lateral penumbra, the reduction of the unnecessary irradiation for the normal tissues. Therefore, Using the posterior oblique the Brain cancer proton therapy should be preceded by decreasing the airgap, by using our in-house Bos frame fixation tool; also, the continuous efforts for reducing the airgap as much as possible for the proton therapy of other area will be necessary as well.

  • PDF

Effects of Recombinant Human Epidermal Growth Factor (rhEGF) on Experimental Radiation-Induced Oral Mucositis in Rats (Rat의 방사선 조사성 구내염에 대한 Recombinant Human Epidermal Growth Factor (rhEGF)의 효과)

  • Jung Kwon-Il;Kim Sun-Hee;Moon Soo-Young;Kim Yeon-Wha;Hong Joon-Pio;Kim Hyun-Sook;Lee Sang-Wook
    • Radiation Oncology Journal
    • /
    • v.24 no.1
    • /
    • pp.67-76
    • /
    • 2006
  • Purpose: Oral mucositis is a common toxicity of radiation or chemotherapy, which is used a treatment for head and neck cancer. We investigated effects of recombinant human epidermal growth factor (rhEGF) on radiation-induced oral mucositis in rat model. Materials and Methods: Spraque-Dawley rats (7 per group) exposed to a single dose of 25 Gy (day 0) on their head, except for one group, were randomly divided into un-treated, vehicle-treated, and two rhEGF-treated groups. Rats were topically applied with rhEGF (15 or $30{\mu}g/oral$ cavity/day) or vehicle to their oral mucosa. Survival rate of rats, weight changes, and food intakes were examined from day 0 to 18 after radiation. Histology study was performed from oral mucosa of rats at day 7 and 18 after radiation. Results: rhEGF-treated groups (15 or $30{\mu}g/oral$) showed all survival rate 33%, whereas un-treated and vehicle-treated groups showed all survival rate 0% at the end of experiment. rhEGF-treated groups statistically had less weight loss compared to vehicle-treated group from day 2 to 7 after radiation. Food intake of rats with rhEGF treatment turned to increase at day 14 after radiation. At 7 day after radiation, un-treated and vehicle-treated groups showed severe pseudomembraneous or ulcerative oral mucositis. On the other hand, rhEGF-treated groups had no more than cellular swelling and degeneration of epidermal cells in oral mucosa of rats. Conclusion: These results suggest that rhEGF has significantly positive effects on radiation-induced oral mucositis in rats. rhEGF display a therapeutic potential on a clinical level.

Regulatory Mechanism of Insulin-Like Growth Factor Binding Protein-3 in Non-Small Cell Lung Cancer (비소세포성 폐암에서 인슐린 양 성장 인자 결합 단백질-3의 발현 조절 기전)

  • Chang, Yoon Soo;Lee, Ho-Young;Kim, Young Sam;Kim, Hyung Jung;Chang, Joon;Ahn, Chul Min;Kim, Sung Kyu;Kim, Se Kyu
    • Tuberculosis and Respiratory Diseases
    • /
    • v.56 no.5
    • /
    • pp.465-484
    • /
    • 2004
  • Background : Insulin-like growth factor (IGF)-binding protein-3 (IGFBP-3) inhibits the proliferation of non-small cell lung cancer (NSCLC) cells by inducing apoptosis. Methods : In this study, we investigated whether hypermethylation of IGFBP-3 promoter play an important role in the loss of IGFBP-3 expression in NSCLC. We also studied the mechanisms that mediate the silencing of IGFBP-3 expression in the cell lines which have hypermethylated IGFBP-3 promoter. Results : The IGFBP-3 promoter has hypermethylation in 7 of 15 (46.7%) NSCLC cell lines and 16 (69.7%) of 23, 7 (77.8%) of 9, 4 (80%) of 5, 4 (66.7 %) of 6, and 6 (100%) of 6 tumor specimens from patients with stage I, II, IIIA, IIIB, and IV NSCLC, respectively. The methylation status correlated with the level of protein and mRNA in NSCLC cell lines. Expression of IGFBP-3 was restored by the demethylating agent 5'-aza-2'-deoxycytidine (5'-aza-dC) in a subset of NSCLC cell lines. The Sp-1/ Sp-3 binding element in the IGFBP-3 promoter, important for promoter activity, was methylated in the NSCLC cell lines which have reduced IGFBP-3 expression and the methylation of this element suppressed the binding of the Sp-1 transcription factor. A ChIP assay showed that the methylation status of the IGFBP-3 promoter influenced the binding of Sp-1, methyl-CpG binding protein-2 (MeCP2), and histone deacetylase (HDAC) to Sp-1/Sp-3 binding element, which were reversed by by 5'-aza-dC. In vitro methylation of the IGFBP-3 promoter containing the Sp-1/Sp-3 binding element significantly reduced promoter activity, which was further suppressed by the overexpression of MeCP2. This reduction in activity was rescued by 5'-aza-dC. Conclusion : These findings indicate that hypermethylation of the IGFBP-3 promoter is one mechanism by which IGFBP-3 expression is silenced and MeCP2, with recruitment of HDAC, may play a role in silencing of IGFBP-3 expression. The frequency of this abnormality is also associated with advanced stages among the patients with NSCLC, suggesting that IGFBP-3 plays an important role in lung carcinogenesis/progression and that the promoter methylation status of IGFBP-3 may be a marker for early molecular detection and/or for monitoring chemoprevention efforts.