• 제목/요약/키워드: HeNB

검색결과 42건 처리시간 0.023초

SQUID와 검출코일의 초전도 결합방식이 개선된 1차 권선형 미분계 시스템 (First-order Wire-wound SQUID Gradiometer System Having Compact Superconductive Connection Structure between SQUID and Pickup Coil)

  • 이용호;유권규;김진목;권혁찬;김기웅;박용기
    • Progress in Superconductivity
    • /
    • 제9권1호
    • /
    • pp.23-28
    • /
    • 2007
  • In order to have a superconductive connection between the wire-wound pickup coil and input coil, typically Nb terminal blocks with screw holes are used. Since this connection structure occupies large volume, large stray pickup area can be generated which can pickup external noise fields. Thus, SQUID and connection block are shielded inside a superconducting tube, and this SQUID module is located at some distance from the distal coil of the gradiometer to minimize the distortion or imbalance of uniform background field due to the superconducting module. To operate this conventional SQUID module, we need a higher liquid He level, resulting in shorter refill interval. To make the fabrication of gradiometers simpler and refill interval longer, we developed a novel method of connecting the pickup coil into the input coil. Gradiometer coil wound of 0.125-mm diameter NbTi wires were glued close to the input coil pads of SQUID. The superconductive connection was made using an ultrasonic bonding of annealed 0.025-mm diameter Nb wires, bonded directly on the surface of NbTi wires where insulation layer was stripped out. The reliability of the superconductive bonding was good enough to sustain several thermal cycling. The stray pickup area due to this connection structure is about $0.1\;mm^2$, much smaller than the typical stray pickup area using the conventional screw block method. By using this compact connection structure, the position of the SQUID sensor is only about 20-30 mm from the distal coil of the gradiometer. Based on this compact module, we fabricated a magnetocardiography system having 61 first-order axial gradiometers, and measured MCG signals. The gradiometers have a coil diameter of 20 mm, and the baseline is 70 mm. The 61 axial gradiometer bobbins were distributed in a hexagonal lattice structure with a sensor interval of 26 mm, measuring $dB_z/dz$ component of magnetocardiography signals.

  • PDF

전기광학효과를 이용한 광도파로형 TE-TM 모드 변환기에 관한 연구 (A Study on Electrooptic Guided-Wave TE-TM Mode Converter)

  • Hong Sik Jung
    • 전자공학회논문지A
    • /
    • 제30A권2호
    • /
    • pp.29-35
    • /
    • 1993
  • A guided-wave TE to TM mode converter was demonstrated by using of the off-diagonal electrooptic coefficients in LiTaO$_{3}$. The input mode is coupled to the other orthogonal mode by the electrooptically induced off-diagonal polarizability. Compared with LiNbO$_{3}$, LiTaO$_{3}$ provides a smaller birefringence and thus a larger phase match period and larger optical bnadwidth. A novel electrode structure allowed a first-order Bragg-coupling phase matching. TE/TM mode conversion efficiency of 90% at 25 [V] was demonstrated with ${\lambda}$=0.63$\mu$m He-Ne laser.

  • PDF

광계측 시스템을 이용한 코로나 방전 검출 (A possible optical measuring technique for corona discharge by use of Pockets sensor)

  • 강원종;마지훈;장용무;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1561-1563
    • /
    • 2001
  • In this paper, an novel optical measuring system based on the electro-optic effect has been proposed and realized using Pockels cell with a view to detecting partial discharge taking place at the needle plane electrode. This system has the following advantages ; nonmetallic probe sensor, immune to external EMI noise and broad band response of the Pockels cell from DC to GHz. And also it is constructed by He-Ne laser, optical fiber, $LiNbO_3$ Pockels cell, photo detector, grin lens, oscilloscope and PC. The characteristics of the developed prototype sensor are investigated under AC and corona discharges.

  • PDF

Pt 코팅된 Si 기판에 제조한 KLN 박막의 구조적 특성 (Structural Properties of KLN Thin Film Deposited on Pt Coated Si Substrate)

  • 박성근;이기직;백민수;전병억;김진수;남기홍
    • 한국전기전자재료학회논문지
    • /
    • 제14권5호
    • /
    • pp.410-416
    • /
    • 2001
  • KLN thin films were fabricated on Pt coated Si(100) wafer using an rf-magnetron sputtering method. The grown KLN thin film consists of 4-fold grains. In this experiment, the structure of 4-fold grained thin film was investigated using XRD and SEM measurements. Pt layer was also deposited using the rf-magnetron sputtering method,. XRD measurement showed that he Pt thin film has Gaussian distribution form with strong (111) direction orientation. The KLN thin film has preferred-orientation of (001) direction, and the peak consists of 2 separate peaks; one with broad FWHM and the other with narrow FWHM. The sharp peak is due to single crystal, and combining with Em results, the 4-fold grain consists of singel crystals with c-axis normal to substrate.

  • PDF

분극에 의한 SBN30 박막의 강유전특성 변화 (Poling-dependent Ferroelectric Properties of SBN30 Thin Films)

  • 장재훈;이동근;이희영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 추계학술대회 논문집 Vol.15
    • /
    • pp.309-312
    • /
    • 2002
  • Ferroelectric $Sr_{0.3}Ba_{0.7}Nb_{2}O_{6}$ (SBN30) thin films were deposited on Pt/Ti/$SiO_{2}$/Si(100) substrates by ion beam sputtering. During annealing treatment at $750^{\circ}C$, poling was attempted by applying dc voltage bias across polished surfaces. Phase relation, microstructure and crystallization behavior were examined using XRD and FE-SEM. Ferroelectric hysteresis characteristics were also determined where both remanent polarization and coercive values decreased with the increase of bias voltage. The measured remanent polarization and coercive field values at 5 V and 10 V bias were $36{\mu}C/cm^2$, $10{\mu}C/cm^2$ and 100kV /cm, 80kV /cm, respectively.

  • PDF

Narrowband Signal Localization Based on Enhanced LAD Method

  • Jia, Ke Xin;He, Zi Shu
    • Journal of Communications and Networks
    • /
    • 제13권1호
    • /
    • pp.6-11
    • /
    • 2011
  • In this paper, an enhanced localization algorithm based on double thresholds (LAD) is proposed for localizing narrowband signals in the frequency domain. A simplified LAD method is first studied to reduce the computational complexity of the original LAD method without performance loss. The upper and lower thresholds of the simplified LAD method are directly calculated by running the forward consecutive mean excision algorithm only once. By combining the simplified LAD method and binary morphological operators, the enhanced LAD method is then proposed and its performance is simply discussed. The simulation results verify the correctness of discussion and show that the enhanced LAD method is superior to the LAD with adjacent cluster combining method, especially at low signal-to-noise ratio.

양자 교환된 리튬나오베이트를 이용한 광 픽업용 λ/2 파장판 제작 (Fabrication of λ/2 Phase Plates for Optical Pickup Using a Proton Exchanged LiNbO$_{3}$)

  • 손경락;김광택;김영조;송재원;박경찬;김진용
    • 대한전자공학회논문지SD
    • /
    • 제37권4호
    • /
    • pp.38-44
    • /
    • 2000
  • 본 논문에서는 리튬나오베이트 기판 상에 벤젠산으로 양자 교환 후 습식 식각하는 방법을 이용하여 청색레이저 다이오드를 광원으로 사용하고자 하는 광 픽업을 위한 λ/2 파장판을 제작하였으며 소자의 기능과 제작과정에 대해서 상세히 서술하였다. 그리고, 소자제작을 위한 최적의 조건을 실험을 통하여 확립하였다. 제작된 소자의 위상 특성은 광학계로 마하젠더 간섭계를 구성하여 파장이 632.8nm인 헬륨-네온 레이저로 측정하였다. 측정 결과 위상오차는 +5°∼6°(3% 이내)로 측정되었다. 본 연구에서 제작한 파장판은 청색 레이저 다이오드를 광원으로 사용하는 광 픽업 시스템의 해상도와 안정도를 향상시키는 유용한 소자로 응용될수 있다.

  • PDF

심자도 측정을 위한 SQUID 센서 기술의 개발 현황 (Review of SQUID Sensors for Measuring Magnetocardiography)

  • 이용호;김진목;유권규;김기웅;권혁찬
    • Progress in Superconductivity
    • /
    • 제13권1호
    • /
    • pp.1-6
    • /
    • 2011
  • Measurement of magnetic signals generated from electric activity of myocardium provides useful information for the functional diagnosis of heart diseases. Key technical component of the magnetocardiography (MCG) technology is SQUID. To measure MCG signals with high signal-to-noise ratio, sensitive SQUID magnetic field sensors are needed. Present magnetic field sensors based on Nb SQUIDs have field sensitivity good enough to measure most of MCG signals. However, for accurate measurement of fine signal pattern or detection of local atrial fibrillation signals, we may need higher field sensitivity. In addition to field sensitivity, economic aspect of the SQUID system is also important. To simplify the SQUID readout electronics, the output voltage or flux-to-voltage transfer of SQUID should be large enough so that direct measurement of SQUID output can be done using room-temperature preamplifiers. Double relaxation oscillation SQUID (DROS), having about 10 times larger flux-to-voltage transfers than those of DC-SQUIDs, was shown to be a good choice to make the electronics compact. For effective cancellation of external noise inside a thin economic shielded room, first-order axial gradiometer with high balance, simple structure and long-baseline is needed. We developed a technology to make the axial gradiometer compact using direct bonding of superconductive wires between pickup coil and input coil. Conventional insert has mechanical support to hold the gradiometer array, and the dewar neck has equal diameter with the dewar bottom. Boiling of the liquid He can generate mechanical vibrations in the gradiometer array due to mechanical connection structure. Elimination of the mechanical support, and direct mounting of the gradiometer array into the dewar bottom can reduce the dewar neck diameter, resulting in the reduction of liquid He consumption.

포켈스센서를 이용한 코로나방전 발생시의 전계변화 측정에 관한 연구 (A possible non-contact measuring technique for the variation of the electric field due to corona discharge by use of Pockels sensor)

  • 마지훈;강원종;임윤석;최재옥;장용무;구자윤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.189-192
    • /
    • 2001
  • In this paper, an novel optical measuring system based on the electro-optic effect has been proposed and realized using Pockels cell with a view to detecting partial discharge taking place at the needle plane electrode. This system has the following advantages ; nonmetallic probe sensor, immune to external EMI noise and broad band response of the Pockels cell from DC to GHz. This system is constructed by He-Ne laser, Mach-Zehnder interferometer with Pockels sensor, balanced photo receiver, data acquisition board and PC. The response characteristics of the developed proto type sensor are examined for AC and corona discharge.

  • PDF

광계측 시스템을 이용한 유.기중 코로나 방전의 전계변화 측정 및 비교분석 (Analysis and the measurement of the variation of electric field in air and oil using optical measuring system)

  • 마지훈;류철휘;강원종;장용무;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1668-1670
    • /
    • 2002
  • Since more than two decades, the conventional PD detecting systems have been employed in order to detect the partial discharges occurring inside the HV power apparatus for their diagnosis by use of different type of detection such as acoustic and UHF detection method. Regardless of their wide on-site application, a certain number of technical inconveniences have been disclosed as follows : multistage amplification. large volume, susceptible to external noise and high price. In this respect, the optical measurement techniques are widely proposed in these days in this concerned field ascribed to the following advantages : immune to external EMI noise and broad band response of the Pockels cell covering from DC to GHz. However, the reliability of several proposed techniques enabling to measure the electric field inside the large high power apparatus has not yet been well approved In this work, an optical measuring system, based on the Pockels effect, has been developed for measuring the field variation due to the corona discharges occurring in air and in oil. This system consists of He-Ne laser, single mode optical fiber, multi mode optical fiber, polarizing film, Y-cut LiNbO3 cell, photo detector, digital oscilloscope and personal computer with GPIB. For this purpose, optical probe has been specially designed and realized and put into the needle-plane electrode. Afterward, same measurement is carried out in oil. We demonstrate the characteristic of the optical measuring system and the measurement results.

  • PDF