• 제목/요약/키워드: He-Ne Laser

검색결과 323건 처리시간 0.028초

저에너지 He-Ne IR laser가 당뇨쥐 말초 신경병증 치유에 미치는 영향 (Effects of the low power He-Ne IR laser on the healing of the peripheral neuropathy in diabetic rats)

  • 노민희;이현옥;백수정;이미애
    • 대한물리치료과학회지
    • /
    • 제7권2호
    • /
    • pp.559-565
    • /
    • 2000
  • This studies were to investigate the effects of low power Helium-Neon Infra-Red (He-Ne IR) laser on the healing of the peripheral neuropathy in diabetic rats. The twenty one Spraque-Dewley adult male rats were assigned to the 3 groups: the control group (7), the diabetic group (7) and the laser group (7). The diabetic group was induced with a single intravenous injection of 50mg/kg body weight streptozotocin dissolved to 0.01mol/L citrate buffer, pH 4.5. The experimental laser group was irradiated low power He-Ne IR laser for 5 minutes every day during 21 days to the diabetic group. The results were as follows: For on and two weeks with laser treatment, there were significantly increased the terminal latencies of the laser treatment group than those of diabetic group, but that was significantly decreased to be similar to the control group on the laser treatment group for three weeks. The change of the amplitude on the laser treatment groups for three weeks was significantly increased to be similar to normal group than that of the diabetic group. As the result, we thank that there were activately effected of lower power He-Ne IR laser on the heeling of the peripheral neurophathy in diabetic rats.

  • PDF

He-Ne 레이저 조사가 배양 섬유모세포의 활성에 미치는 영향 (Effects of He-Ne Laser Irradiation on the Activity of the Cultured Fibroblast)

  • 송인영;이재형
    • The Journal of Korean Physical Therapy
    • /
    • 제9권1호
    • /
    • pp.71-79
    • /
    • 1997
  • The purpose of this study were to determined the effect of laser irradiation on the fibroblast activity. Cultures of 3T3 fibroblasts were subjected to Helium Neon laser(632.8 nm) irradiation of various energy density. On one, two and three consecutive days the fibroblast monolayers wert irradiated for period from 0 to 32 minutes with 8 mW of average output power. The fibroblast activity was determined by the quantitative assay of MTT, SRB and NR after incubation of the fibroblasts for 24 hours. Results show that exposure duration from 2 min to 32 min could increase MTT at three consecutive days, whereas control and 1 min, one and two days irradiation had were not inclosed. The SRB and NR were inclosed at two and three consecutive days from 2 min to 32 min, whereas control and 1 min, and once radiation were not increased. These result demonstrate that energy density from 0.48 to 7.64 J/cm could increase cellular protein contents and fibroblast activity at more than twice irradiation of laser, whereas low energy density (less than 0.24 J/m) and once irradiation of laser had no effect. The results suggest that the beneficial effect of the He-Ne laser with adequate dose on fibroblast activity in vitro.

  • PDF

Sensitization of Periodontitis Disease Causing Bacteria by Low Power He-Ne Laser Radiation

  • Satsangi, Akash Tripathi;Mathur, Manish;Saxena, Parul;Prasad, Guru;Shrivastava, Jitendra Nath;Shrivastava, Jenendra Nath;Roy, Sukhdev
    • Journal of Photoscience
    • /
    • 제11권2호
    • /
    • pp.55-59
    • /
    • 2004
  • The present investigation is an attempt to create an optimized protocol for a bactericidal modality of different powers of He-Ne laser radiation to eliminate periodontitis disease causing bacteria from dental plaques. Periodontitis is most prevalent infectious disease of men and caused by a limited number of Gram negative oral bacteria. Porphyromonas gingivalis and Streptococcus sanguis are the important bacteria responsible for periodontitis diseases. Effect on periodontitis disease causing bacteria were produced by the exposure of different powers of He-Ne laser light i.e. 9 mW, 17 mW and 26 mW of red colour of wavelength 632.8 nm in two different periods of time i.e. 10 min. and 20 min. in the presence of dye Methylene blue (MB) used as a photosensitizer. The results have been shown in terms of percentage inhibition of colony forming units (cfu.) of bacteria. This study has shown that maximum inhibition of cfu. were observed in Laser+MB-20 min. exposure time. This inhibition was followed by Laser+MB-10 min., but minimum inhibition was seen in Laser only at 10 min. exposure. In case of effect of methylene alone on the cfu. of bacteria, it was seen that MB have not shown more inhibition of cfu. and it had shown that the no. of cfu. are very similar to that of control. The above observation of the present study was seen in case of every 3 different type of used powers of laser for both the bacteria. Maximum percentage inhibition of cfu. were seen in case of 26mW powers of He-Ne laser, which was 67. 28% to 61.42% for Porphyromonas gingivalis and Streptococcus sanguis respectively. So, increasing the power of laser (safe range for dentistry is 3-30 mW) under conditions shows an increased percentage inhibition of cfu. Thus the present investigation may be a useful adjunct with mechanical debridement in the prevention of recolonization of subgingival lesions by pathogenic microorganisms which are harmful and drug resistant.

  • PDF

광소자와 헬륨-네온 레이저를 이용한 디스크 캠의 진동 측정 (Measurement of Vibration of Rotating Disk Cam Using He-Ne Laser and Photodiode)

  • 유웅재;이규섭;김재도
    • 한국정밀공학회지
    • /
    • 제12권10호
    • /
    • pp.69-77
    • /
    • 1995
  • This laser measurement system has been developed using He-Ne laser and photodiode. The laser beam intensity transmitted on a photodiode was disturbed by eccentrically rotating disk cam with various speeds. The photodiode and an amplifier were used to change the detected beam intensity into voltage. The digitized data through the developed system were recorded on a micro-computer by using a signal analysis program. Its reliability was ascertained by using FFT analyzer. The vibration of rotating disk cam can be analyzed by measureing the intensity change of laser beam which the results by FFT analyzer were similar to. The amplifier was devised to be able to modulate the fluctuations of laser beam. The voltage could be linearly recorded with the change of the laser beam intensity.

  • PDF

박테리아로돕신의 광순환 특성을 이용한 광학적 논리회로 구현 (Realization of optical logic gates using photocycle properties of bacteriorhodopsin)

  • 오세권;유연석
    • 한국광학회지
    • /
    • 제13권5호
    • /
    • pp.414-420
    • /
    • 2002
  • 본 연구에서는 bacteriorhodopsin(bR)이 첨가된 고분자 박막을 이용하여 광 논리회로 특성을 구현하였다. bR은 분광학적으로 구분되는 몇 단계의 중간단계로 구성된 복잡한 참순환 과정을 수반하고 있다. 우리는 bR의 광순환 과정중 B상태와 M상태의 흡수도 변화를 고려하여 He-Ne 레이저(632.8 nm)와 He-Cd 레이저(413 nm) 이용하여 광학적 논리회로를 구현하였다. 또한 B상태와 K상태간의 흡수 스펙트럼을 고려하여 He-Ne 레이저(632.8 nm)와 Nd-YAG 레이저의 제2고조파인 532 nm를 이용하여 고속 AND logic gate를 구현하였다.

Two Versions of He-Ne Laser 3.39 μm with Radio Frequency Excitation

  • Kopica, Miroslaw;Choi, Jong-Woon
    • Journal of the Optical Society of Korea
    • /
    • 제12권1호
    • /
    • pp.31-37
    • /
    • 2008
  • To increase output power of a He-Ne laser we propose to use the capacitive rf discharge and implement four channel structure. Most of experiments were carried out with a single laser tube from this structure to optimize the output mirror transmission, pressure and composition of the mixture. A laser tube of 2.8 mm inner diameter and 50 cm discharge length can give an output power of above 5.5 mW at 3.39 ${\mu}m$. Four such tubes in "matrix" structure let us obtain 20 mW of output. Simplified models which can be used to evaluate the behavior of an equivalent electrical circuit with laser plasma and qualitative characteristics of output power of He-Ne laser were also described.

혈관내(血管內) Helium-Neon Laser 조사(照射)가 혈중(血中) Total Cholesterol 및 Triglyceride 수치변화(數値變化)에 미치는 영향(影響) (The effects of Helium-Neon(He-Ne) laser irradiation on high-lvevel of Total Cholesterol and Triglyceride)

  • 백은탄;민재영;국윤형;오상덕;라수연;임승만
    • 대한한방내과학회지
    • /
    • 제21권5호
    • /
    • pp.799-803
    • /
    • 2000
  • Objective : This study was designed to assess effects of He-Ne laser irradiation on high-level of Total Cholesterol and Triglyceride. Methods : The 76 patients who have been checked Total Cholesterol and Triglyceride high were divided into a study group of patient who were irradiated and into a control group of patients who did not receive irradiation.. Then, patients rechecked Total Cholesterol and Triglyceride after 1 month later. Results : In patients of study group, The level of Total Cholesterol and Triglyceride was decreased. But In comparison with control group, there was no significant effect of decrement of Total Cholesterol and Triglyceride. Conclusions : These results suggest that He-Ne laser irradiation may have no significant decrement effects on high-level of Total Cholesterol and Triglyceride.

  • PDF

서로 다른 빔에 의한 AsSeS 박막의 홀로그래픽 데이터 격자형성 (Holographic Grating Formation of AsSeS Thin Films with the Incident Beam Wavelength)

  • 김재훈;신기준;김현구;구상모;정홍배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.445-446
    • /
    • 2008
  • In this paper, we investigated the diffraction grating efficiency on Ag-doped amorphous chalcogenide Ag/AsSeS thin film for used to volume hologram. The film thickness was 2 um and diffraction efficiency was obtained from He-Ne (632.8nm) and DPSS(532nm) (P:P) polarized laser beam on Ag/AsSeS thin films. As a result, for the films, the maximum grating diffraction efficiency using He-Ne laser(632nm) is 0.15%[2000sec]. And then The recording speed of DPSS laser was about 40s which of batter than He-Ne lasers.

  • PDF

2-종 모드 레이저를 이용한 고분해능 헤터로다인 간섭계 (A High-Resolution Heterodyne Interferometer using Beat Frequency between Two-Axial Modes of a HeNe Laser)

  • 김민석;김승우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.214-219
    • /
    • 1997
  • We propose a new scheme of high-resolution heterodyne interferometer that employs the two-axial mode He-Ne laser with an inter-mode beat frequency of 600-1000 MHz. An electronic RF-heterodyne circuit lowers the beat frequency down to 5 MHz, so that the phase change of the interferometer output is precisely measured with a displacement resolution of 0.1 nanometer without significant loss of dynamic bandwidth. A thermal control scheme is adopted to stabilize the cavity length with aims to suppress frequency drifts caused by the phenomena of frequency pulling and polarization anisotropy of the two-axial mode laser to a stability level of 2 parts in $10^9$. The two-axial mode HeNe laser yields a high output power of 2.0 mW, whlch allows us to perform multiple measurements of up to 10 machine axes simultaneously.

  • PDF