• 제목/요약/키워드: Hazardous Air Pollutants(HAPs)

검색결과 49건 처리시간 0.023초

대기 중 휘발성유기화합물질 및 알데하이드의 분석 신뢰도 향상에 관한 고찰 (Study on Improvement in Reliability of Analysis for VOCs and Aldehydes)

  • 이민도;이상욱;임용재;김영미;김소영;문광주;한진석;정일록
    • 한국대기환경학회지
    • /
    • 제22권4호
    • /
    • pp.468-476
    • /
    • 2006
  • Hazardous air pollutants (HAPs) have high toxicity and bioaccurnulation potentials into human body even inbsmall amount (levels of ng/$m^3$). As the levels of HAPs might be controversial, it has been become essential to establish the analysis method for correct results. In this study, various analysis methods of VOCs and Aldehydes were compared in order to select the proper methods in our condition. Sampling and analysis method of VOCs were followed to EPA TO-14a and TO-17. VOCs were collected in absorption tube and separated by thermal desorption unit then analyzed by GC/MSD. Aldehydes were sampled in DNPH-cartridge and extracted into solution then analyzed by HPLC as the same condition of EPA TO-13a. This study also shows the results of QA/QC system of selected methods. Some experiments could be improving the data assurance blank test, calibration check, repetition precision check, the determination of detection limit and reproducibility of the retention time. Precisions of VOCs and aldehydes were ranged in 2$\sim$9% and 1$\sim$4% RSD, respectively. Recovery rate of VOCs showed variable ranges from 60 to 133.5%. MDL of VOCs and aldehydes were 0.044$\sim$0.284 ppb and 0.14$\sim$1.02 ng, respectively.

Determination of Volatile Organic Compounds (VOCs) Using Tedlar Bag/Solid-phase Microextraction/Gas Chromatography/Mass Spectrometry (SPME/GC/MS) in Ambient and Workplace Air

  • Lee, Jae-Hwan;Hwang, Seung-Man;Lee, Dai-Woon;Heo, Gwi-Suk
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권3호
    • /
    • pp.488-496
    • /
    • 2002
  • SPME techniques have proven to be very useful tools in the analysis of wide VOCs in the air. In this study, we estimated VOCs in ambient and workplace air using a Tedlar ba /SPME/GC/MS system. The calibration curve was set to be linear over the range of 1-30 ppbv. The detection limits ranged from 10 pptv to 0.93 ppbv for all VOCs. Reproducibility of TO-14 target gas mixtures by SPME/GC/MS averaged at 8.8 R.S.D (%). Air toxic VOCs (hazardous air pollutants, HAPs) containing a total of forty halohydrocarbons, aromatics, and haloaro-matic carbons could be analyzed with significant accuracy, detection limit and linearity at low ppbv level. Only reactive VOCs with low molecular weight, such as chloromethane, vinylchloride, ethylchloride and 1,2-dichloro-ethane, yielded relatively poor results using this technique. In ambient air samples, ten VOCs were identified and quantified after external calibration. VOC concentration in ambient and workplace air ranged from 0.04 to 1.85 ppbv. The overall process was successfully applied to identify and quantify VOCs in ambient/workplace air.

활성탄 또는 촉매가 장착된 배리어 유전체 방전 하이브리드. 공기청정 시스템의 나노입자 및 잔류 오존 제거 특성 (Nano Particle Precipitation and Residual Ozone Decomposition of a Hybrid Air Cleaning System Comprising Dielectric Barrier Discharge Plasma and MnO2 Catalyst or Activated Carbon)

  • 변정훈;황정호;지준호;강석훈
    • 대한기계학회논문집B
    • /
    • 제27권4호
    • /
    • pp.524-533
    • /
    • 2003
  • DBD(Dielectric Barrier Discharge) plasma in air is well established for the production of large quantities of ozone and is more recently being applied to aftertreatment processes for HAPs(Hazardous Air Pollutants). Aim of this work is to determine design and operating parameters of a hybrid air cleaning system. DBD and ESP(Electrostatic Precipitator) are used as nano particle charger and collector, respectively. Pelletized MnO$_2$ catalyst or activated carbon is used fer ozone decomposition or adsorption material. AC voltage of 7~10 KV(rms) and 60 Hz is used as DBD plasma source. DC - 8 KV is applied to the ESP for particle collection. The overall particle collection efficiency for the hybrid system is over 85 % under 0.64 m/s face velocity. Ozone decomposition efficiency with pelletized MnO$_2$ catalyst or activated carbon packed bed is over 90 % when the face velocity is under 0.4 m/s in dry air.

흡착관과 캐니스터를 이용한 대기 중 휘발성유기화합물 측정방법의 비교 평가 (Comparison of Measurement Methods for Volatile Organic Compounds in Ambient Air Using Adsorbent Tubes and Canisters)

  • 백성옥;서영교;허귀석;전찬곤;이민도;한진석
    • 한국대기환경학회지
    • /
    • 제32권3호
    • /
    • pp.305-319
    • /
    • 2016
  • This study was carried out to evaluate the performance of two sampling methods, i.e., adsorbent tubes and canisters, for the measurement of ambient volatile organic compounds (VOCs). A total of 24 target VOCs were selected from a list of 48 priority hazardous air pollutants (HAPs) in Korea. The two sampling methods were investigated with a wide range of performance criteria such as repeatability, linearity, and lower detection limits. In addition, mean relative errors (MRE) and mean duplicate precisions (MDP) were estimated by inter-lab comparison studies for duplicate field samples. Precisions for the two methods appeared to be well comparable with the performance criteria recommended by USEPA TO-15 and TO-17 for canister and adsorbent methods, respectively. Correlations and variations between the VOCs concentrations determined by the two methods were generally good in most cases. However, MREs and MDPs for individual VOCs appeared to be widely ranged, depending on each VOC. This implies that the two methods have its own advantages and disadvantages in determining a variety of VOCs in ambient air, and neither of which has absolute superiority. Finally, 9 of 24 VOCs were found to be difficult to determine by either methods due to their unstability in a canister, and lack of appropriate standard materials. Thus, it is suggested that development of measurement methods for such unstable VOCs is an urgent task from a viewpoint of HAPs management.

바닥재의 확산계수 및 분배계수 산정 (The Determination of Diffusion and Partition Coefficients of Indoor Bottom Finishing Materials)

  • 박진수;;김신도;윤중섭
    • 한국환경보건학회지
    • /
    • 제34권3호
    • /
    • pp.219-225
    • /
    • 2008
  • Many building materials may contain high concentrations of volatile organic compounds (VOCs) and other hazardous pollutants(HAPs). Specifically, VOCs discharged by indoor building material may cause "new house" syndrome, atopic dermatitis etc. The diffusion coefficient and initially contained total VOC quantity were determined using microbalance experiments and small chamber tests. Interactions between volatile organic compounds (VOCs) and vinyl flooring (VF), a relatively homogenous, diffusion-controlled building material, were characterized. Rapid determination of the material/air partition coefficient (K) and the material-phase diffusion coefficient (D) for each VOC was achieved by placing thin VF slabs in a dynamic microbalance and subjecting them to controlled sorption/desorption cycles. K and D are shown to be independent of concentration for all of the VOCs and water vapor. This approach can be applied to other diffusion-controlled materials and should facilitate the prediction of their source/sink behavior using physically-based models.

서울시 터널의 유해대기오염물질 농도변화 특성 분석 (Characteristics of Hazardous Air Pollutant Level in Road Tunnels in Seoul)

  • 박진아;이원영;김진아;김익수;김현수;정종흡;윤중섭;정권;엄석원
    • 한국환경보건학회지
    • /
    • 제39권6호
    • /
    • pp.541-549
    • /
    • 2013
  • Objectives: We analyzed the characteristics of hazardous air pollutants (HAPs) in road tunnels in Seoul. Methods: Particle matter ($PM_{10}$), elemental carbon (EC), organic carbon (OC), and 16 species of polycyclic aromatic hydrocarbons (PAHs) in two road tunnels (NS tunnel and HJ tunnel) were sampled and analyzed from 2007 to 2011. Results: Levels of $PM_{10}$ and carbon ingredients which were mainly emitted from diesel-fueled vehicles showed a declining tendency in both road tunnels. PAHs levels in HJ were declining slightly while PAHs levels in the NS tunnel fluctuated considerably and showed an increasing tendency. Conclusions: These results suggested that the abatement project of diesel vehicle emissions by the Seoul metropolitan government from 2007 has had an impact on the reduction of DVE into the air, though there exist many things to consider for analyses.

Monte-Carlo 모의실험을 통한 부분 인구집단별 벤젠 및 PM10의 노출 및 위해성 평가 (Exposure and Risk Assessment of Benzene and PM10 for Sub-populations using Monte-Carlo Simulations)

  • 박진현;양소영;박윤경;류현수;김은채;최영태;허정;조만수;양원호
    • 한국환경보건학회지
    • /
    • 제45권3호
    • /
    • pp.247-257
    • /
    • 2019
  • Objectives: The Korea Ministry of Environment regulates concentrations of hazardous air pollutants (HAPs) through Atmosphere Environmental Standards to protect public health from HAPs. However, simply determining the exceedance of HAP concentrations has several limitations and more comprehensive assessment is required. In addition, integrated risk assessment is needed considering exposure in all microenvironments, including outdoor as well as indoor environments. The purpose of this study was to assess the differences in risk by sub-population groups according to time-activity patterns and reported concentrations, as well as the lifetime risk for Koreans. Methods: In this study, we calculated time-weighted average exposure concentrations for benzene and $PM_{10}$ among preschool-age children, students, housewifes, workers, and the elderly using residential time and concentrations for indoor (house, school or workplace, other), outdoor, and transport by the meta-analysis method. The risk assessments were conducted by excess cancer risk and disease death risk using 1,000,000 Monte-Carlo simulations for probabilistic analysis. Results: Preschool-age children, students, housewifes, workers, and the elderly spent 91.9, 86.0, 79.8, 82.2, and 77.3% of their day in their house, workplace, or school, respectively. The more than 99% excess cancer risk for benzene exceed 1.0E-06 in all sub-populations and lifetime. The acute disease death risk for $PM_{10}$ for housewifes and workers for lifetime were 3.35E-04 and 3.18E-04, and chronic disease death risks were 2.84E-03 and 2.70E-03, respectively. Conclusions: The risk of benzene and $PM_{10}$ by sub-population group and for the lifetime of housewifes and workers were assessed. Benzene showed risky results for this study. All disease death risks of $PM_{10}$ were higher than 1.0E-04 and showed different risks by sub-population. This study can be used as a basis for lifetime exposure and risk assessment to benzene and $PM_{10}$.

배리어 유전체 방전형 2단 전기집진기의 나노입자 집진 및 잔류 오존 제거 특성 (Characteristics of Nano Particle Precipitation and Residual Ozone Decomposition for Two-Stage ESP with DBD)

  • 변정훈;지준호;윤기영;황정호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1678-1683
    • /
    • 2003
  • DBD(Dielectric Barrier Discharge) plasma in air is well established for the production of large quantities of ozone and is more recently being applied to aftertreatment processes for HAPs(Hazardous Air Pollutants). Although DBD high electron density and energy, its potential use as nano and sub-micron sized particle charging are not well known. Aim of this work is to determine design and operating parameters of a two-stage ESP with DBD. DBD and ESP are used as particle charger and precipitator, respectively. We measured particle precipitation efficiency of two-stage ESP and estimated ozone decomposition of both pelletized $MnO_2$ catalyst and pelletized activated carbon. To examine the particle precipitation efficiency, nano and sub-micron sized particles were generated by a tube furnace and an atomizer. AC voltage of $7{\sim}10$ kV(rms) and 60 Hz is used as DBD plasma source. DC -8 kV is applied to the ESP for particle precipitation. The overall particle collection efficiency for the two-stage ESP with DBD is over 85 % under 0.64 m/s face velocity. Ozone decomposition efficiency with pelletized $MnO_2$ catalyst or pelletized activated carbon packed bed is over 90 % when the face velocity is under 0.4 m/s in dry air.

  • PDF

대기 중 PM-10의 오염원 추정을 위한 다환방향족탄화수소와 무기원소자료의 예비통계분석 -1996년 2월~6월까지 대규모 영통건설지역 주변을 중심으로- (A Preliminary Statistical Stduy of Polycyclic Aromatic Hydrocarbons and Inorganic Elements Data for Extimation Ambient PM-10 Sources -Near the Huge Young-Tong Construction Area during Feb. 1996 to June 1996-)

  • 손정화;황인조;김동술
    • 한국대기환경학회지
    • /
    • 제16권1호
    • /
    • pp.11-22
    • /
    • 2000
  • Polycyclic aromatic hydrocarbons(PAHs) have known as potentially hazardous air pollutants(HAPs0 to human health because of its carcinogenic and mutagenic behaviors. The purpose of this study was to determine the level of 6 PAHs(Fluoranthene, Pyrene, Benzo[a]anthracene, Chrysene, Benzo[b]fluoranthene, and Benzo[a]pyrene) as well as 10 inorganic elements(Cr, Na, K, Zn, Pb, Fe, Cu, Ti, Al and Cd) in the ambient PM-10. The total of 115 samples had been collected from February, 1996 to June, 1996 on quartz fiber by a PM-10 high volume air sampler near the Yong-Tong Apartment complexes. A statistical analysis was performed for the PAHs and inorganic elements data set using a principal component analysis in order to identify qualitatively the potential sources of PM-10. A total of 6 principal components were separated by intensive data pretrement and transformation processes, such as soil, refuse incineration, oil burning, coal burning, field burning, vehicle emission sources. The results showed that PAHs were associated with various burning activities like refuse and field burning, coal burning, and oil burning emissions in the study area. These derived sources were well matched with the previously known source profiles in terms of compositonal order and level of measured species. The combination data set consisted of both organic and inorganic species might provide more powerful source signature and might increase the number of potentially derived sources than PAHs or inorganic data alone.

  • PDF