• Title/Summary/Keyword: Harmonics reduction

Search Result 263, Processing Time 0.025 seconds

Experimental Realization of Matrix Converter Based Induction Motor Drive under Various Abnormal Voltage Conditions

  • Kumar, Vinod;Bansal, Ramesh Chand;Joshi, Raghuveer Raj
    • International Journal of Control, Automation, and Systems
    • /
    • v.6 no.5
    • /
    • pp.670-676
    • /
    • 2008
  • While the matrix converter has many advantages that include bi-directional power flow, a size reduction, a long lifetime, and sinusoidal input currents, it is vulnerable to the input voltage disturbances, because it directly exchanges the input voltage to the output voltage. So, in this paper, a critical evaluation of the effect of various abnormal voltage conditions like unbalanced power supply, balanced non-sinusoidal power supply, input voltage sags and short time blackout of power supply on matrix converter fed induction motor drives is presented. The operation under various abnormal conditions has been analyzed. For this, a 230V, 250VA three phase to three phase matrix converter (MC) fed induction motor drive prototype is implemented using DSP based controller and tests have been carried out to evaluate and improve the stability of system under typical abnormal conditions. Digital storage oscilloscope & power quality analyzer are used for experimental observations.

Active Power Filter System for Harmonics Reduction of Large Capacity Commercial Air-Conditioner (대용량 상업용 에어컨의 고조파 저감을 위한 Active Power Filter 시스템 개발)

  • Lee, Donggeun;Chae, Seungwoo;Lee, Yonghwa;Oh, Jeongeon;Cheong, Dalho
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.511-512
    • /
    • 2016
  • 최근 대다수의 상업용 에에컨 분야에서는 제품의 효율 상승 및 운전 영역 확대]를 위해 대용량 고효율 인버터를 사용하고 있으며, 이로 인해 계통 입력 전류의 고조파 성분이 증가하여 역률 저하, 발열 뿐만 아니라 여러 가지 계통 사고의 원인이 되고 있다. 본 논문에서는 인버터가 적용된 대용량 상업용 에어컨의 입력 전류 고조파 성분을 저감하기 위한 3상용 Active Power Filter 시스템 기술을 제안한다. 또한 제안된 시스템을 설제 제품에 적용함으로써 계통 압력 전류의 고조파 저감 성능을 확인 하였다.

  • PDF

12 Phase Multiple GTO Inverter (12상 다중 GTO 인버터)

  • Oh, Dong-Sub;Lee, Kyu-Jong;Seong, Se-Jin;Choi, Soo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.291-294
    • /
    • 1990
  • Fuel cell system needs DC-AC conversion inverter system because its output is DC. And the inverter system can be operated not only in stand-alone load but also in interactive mode in interactive mode, it is necessary to control active-reactive power of inverter and to synchronize inverter output voltage to power line voltage. In this paper, a 12 phase multiple VSI type GTO inverter system for fuel cell is described. Synchronization between power line voltage phase and inverter output voltage phase, and reduction of harmonics in the output voltage phase are the purpose of this inverter system. This control algorithm for the system is realized by the software method utilizing 8031AH 8bit Microprocessor.

  • PDF

A Study on the Active PFC of BF converter (BF 컨버터의 능동 PFC에 관한 연구)

  • 송석호;이우철;임승하;사공석진
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.3
    • /
    • pp.82-92
    • /
    • 1999
  • In this paper, we realize the active PFC(Power Factor Correction) system of the BF(Boost Forward) converter with the PWM-PFM control technique to control DC output voltage, to rermve the noise like hanronics at the output voltage, amd to control the input ClUTent with sinusoidal wave synchronized by the source voltage. We take the simulation and analyze the switching signal of the BF converter, input/output voltage and current, its harmonics and power factor through PSpice. And it has bren obtained harmonic reduction and efficiency improverrent.errent.

  • PDF

Sensitivity Analysis of Design Parameters for Reduction of Cogging Torque in Brushless DC Motors used for Automobile Part (자동차 부품용 BLDC 모터 내의 코깅 토크 저감을 위한 설계 변수의 민감도 해석)

  • 황상문
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.2
    • /
    • pp.235-243
    • /
    • 1998
  • For motor operation at low speeds and loads, torque pulsation by the cogging torque is often a source of vibration and control difficulty. In this paper, the magnetic field of a motor is calculated by finite element method. The periodic cogging torque is determined using Maxwell stress method and time stepping method, and then decomposed using fourier series expansion, The purpose of this paper is to characterize design parameters on the cogging torque and to design a permanent magnet motor with a cogging torque less vulnerable to vibration, without sacrificing the motor performance. The design parameters include stator slot width, permanent magnet slot width, airgap length and magnetization direction. A new design with a less populated frequency spectrum of the cogging torque is proposed after characterizing individual effect of design parameters. Magnet pole edge shaping, by gradually increasing the cogging torque with reduced higher harmonics.

  • PDF

Reduction of Electromagnetic Switching Noise in v/f Induction motor Drives by Two-Phase Random PWM Scheme (2상 Random PMW기법에 의한 유도모터 v/f 일정 속도 제어 시스템의 전자기적 스위칭 소음저감)

  • Kim, J.G.;Lim, Y.C.;Wi, S.O.;Jung, Y.G.
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.217-220
    • /
    • 2003
  • In this paper, Inverter drives adopting 2 phase space vector SRP-PWM (Separately Randomized Pulse Position PWM) with fixed switching frequency is proposed. The proposed 2 phase space vector SRP-PWM scheme is based on the 3 phase SRP-PWM. In the proposed SRP-PWM scheme, each of two phase pulses is located randomly in each switching interval. The experimental results show that the voltage and acoustic noise harmonics are spread to a wide band area. Also, the performance of the proposed 2 phase SRP-PWM and the conventional center aligned SVM are compared to each other. In resuit, the speed response is nearly simitar to each other from the viewpoint of the v/f constant control.

  • PDF

Analysis and Design of Filter at AC Source of Sigle Phase PWM Converter (단상 PWM 컨버터의 전원측 필터의 해석 및 설계)

  • Kim, Hong-Sung;Lee, Seung-Yo;Kim, Han-Sung;Yu, Gwon-Jong;Song, Jin-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.447-449
    • /
    • 1994
  • This paper deals with the static characteristics of filters at the AC source in single phase PWM converter using hysterisis current control method. The filters are needed to reduce the current harmonics. In general, there are two kinds of filters which can be used for current controlled PWM converter. One is the low pass filter, the other is the resonant filter for a frequency. This paper designs these filters by analysing the characteristics. And these filters are compared through performance index such as harmonic reduction factor and the value of components which make up filters.

  • PDF

The PWM method of 3-Level inverter for harmonic reduction (고조파 저감을 위한 3-Level 인버터 구동용 PWM 변조법)

  • Chung, Yon-Tack;Lee, Sa-Young;Lee, Woo-Choon;Kim, Hyun-Woo;Ahn, Kyu-Bock;Chai, Heui-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.491-494
    • /
    • 1994
  • The 3-level inverter is applied to the induction motor drive as the voltage type inverter for large poller one. This inverter divides the DC link voltage into the two parts and it is supplied to the inverter. The 3-level inverter can reduces the voltage between the each devices, and get more sinusoidal current waveform. This paper presents the new PWM method which can reduces the harmonics. The modulation at the inverter side is implemented using a DSP microprocessor.

  • PDF

Power Quality Measurement and Analysis of Extra-High Voltage Customer (특고압 수용가의 전력품질 측정 및 분석)

  • Cho, Jae-Hyeong;Lee, Jong-Pil;Ji, Pyeong-Shik
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.4
    • /
    • pp.286-290
    • /
    • 2015
  • Power system is composed of a number of power devices and equipment. This factor affects the power quality is also displayed very complicated and varied. The accurate measurement and analysis of the causes of power quality problems is difficult. In preparing for these issues, there are many difficulties. In this study, Power quality of A public establishment of Chungbuk province were measured and analyzed. Measurement results of the fifth harmonic current was very large. Accordingly, the harmonic reduction will be needed. This research will be utilized as fundamental data to improve power quality for power utility and customer.

Winding Method of Transformer for Zero-Sequence and Negative-Sequence Harmonic Elimination (영상분 및 역상분 고조파 제거를 위한 변압기 결선방식)

  • Kim, Tae-Hoon;Park, Jun-Yeal
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.7
    • /
    • pp.896-902
    • /
    • 2014
  • As the various kinds of load who generate higher harmonics increases according as the power electronics technology develops, harmonic treatment standard is proposed by IEEE and IEC. Because establishment of harmonic reduction device is required for existent installment to satisfy harmonic treatment standard, the problem of investment charge and installation space increasing may be occurred. In order to solve these problems, a novel transformer connection method using principles of PCT and ZED is suggested.