• 제목/요약/키워드: Harmonics assessment

검색결과 39건 처리시간 0.023초

고속철 부하의 고조파 측정, 평가 및 시뮬레이션에 관한 연구 (A Study on the Harmonics Measurement, Assessment and Simulation of the High Speed Electric Train Loads)

  • 김경철;진성은;이주홍;이일무;김주락
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.272-277
    • /
    • 2006
  • High speed electric trains have nonlinear loads including converters and inverters for the contol synchronous motors. Harmonic field measurements have shown that the harmonic contents of a waveform varies with time. Direct application of the harmonic assessment to the snapshot measurements would result in ambiguous conclusions depending on which instant is sampled. A cumulative probablistic approach is the most commonly used method to solve time varying harmonics. This paper provides an in depth analysis on harmonics field measurement of the high speed electric train loads, harmonics assessment by the international harmonic standards IEC 61000-3-6 and IEEE std. 519-1992, and harmonics simulation using EDSA program for the case study.

  • PDF

가정용 연료전지 시스템의 계통연계 시 수용가 및 배전계통에서의 고조파 영향 평가 (An Assessment on Harmonics Effect in Customer and the Distributed Power System during Grid Connection of Residential Fuel Cell System)

  • 박찬엄;정진수;한운기
    • 전기학회논문지
    • /
    • 제60권6호
    • /
    • pp.1280-1285
    • /
    • 2011
  • Recently, due to the use of fossil fuels for electric power production, carbon emissions increased excessively. Thereby, in order to replace fossil fuels, many studies about fossil fuels such as solar and fuel cell energy source are progressing. Fuel cell system has high energy conversion efficiency. Also, fuel cell system is environmentally friendly system because the carbon emission is almost not occur. Therefore, the fuel cell system is considered as the core technology of in the fields of the future energy and environmental. Fuel cell system has an effect on distribution power system because another power source of other than large power plants. So, fuel cell system can be degradation reason of power quality in the power system. In this paper, we constructed the system for an assessment on harmonics effect. The system is composed with power source, harmonics generation and linear load, fuel cell system. we also performed assessment on harmonics effect in customer and the distributed power system during grid connection of residential fuel cell system. An assessment cases are divided into three. A Case 1 is state that residential load and fuel system are connected to grid, Case 2 is state that residential load and harmonics load are connected to grid, and Case 3 is state that all loads are connected to grid. As a output of fuel cell system is increase, analysis results based on assessment system showed that power quality became more aggravation as effect of harmonics.

시간에 따라 변하는 전기로 부하의 고조파 측정, 평가 및 시뮬레이션에 관한 연구 (A Study on the Time-varying Harmonics Measurement, Assessment and Simulation of the Electric Arc Furnace Loads)

  • 김경철;진성은;이주홍;전영수
    • 조명전기설비학회논문지
    • /
    • 제20권5호
    • /
    • pp.9-17
    • /
    • 2006
  • 규모가 큰 제철소는 전기로와 같은 비선형 부하를 가지고 있다. 고조파 측정 결과로 고조파는 시간에 따라 변하는 특성이 관측되었다. 순시치 측정에 의한 고조파 평가는 측정 순간에 따라 고조파가 다를 수 있으므로 모호한 결과를 초래할 수 있다. 시간에 따라 변하는 고조파를 해결하기 위해 쓰이는 가장 보편적인 방법은 누적확률을 사용하는 것이다. 고조파 시뮬레이션은 사례연구 시스템의 전압 및 전류 왜곡을 평가하기 위해 이용되었다. 본 논문에서는 전기로 부하의 고조파 현장 측정, 국제 고조파 관리 기준인 IEC 61000-3-6과 IEEE Std. 519에 의한 고조파 평가, 시간에 따라 변하는 고조파의 시뮬레이션을 심도 있게 다루고자 한다. 고조파 해석 프로그램인 EDSA는 사례 연구에 시뮬레이션 도구로 사용되었다.

현장시험에 의한 고속전철 부하의 고조파 시뮬레이션에 관한 연구 (A Study on the Harmonics Simulation of the High Speed Electric Train Loads by Field Tests)

  • 김경철;김유준
    • 조명전기설비학회논문지
    • /
    • 제21권6호
    • /
    • pp.40-47
    • /
    • 2007
  • 고속전철 부하는 동기 전동기를 제어하기 위해 컨버터와 인버터를 포함한 많은 비선형 부하를 가지고 있다. 고조파 측정 결과로 고조파는 시간에 따라 변하는 특성이 관측되었다. 순시치 측정에 의한 고조파 평가는 측정 순간에 따라 고조파가 다를 수 있으므로 모호한 결과를 초래할 수 있다. 시간에 따라 변하는 고조파를 해결하기 위해 쓰이는 가장 보편적인 방법은 누적확률을 사용하는 것이다. 고조파 시뮬레이션은 사례연구 시스템의 전압 및 전류 왜곡을 평가하기 위해 이용되었다. 본 논문에서는 고속전철 부하의 고조파 현장 측정, 국제 고조파 관리 기준인 IEC 61000-3-6과 IEEE Std. 519에 의한 고조파 평가, EDSA 프로그램을 사용한 시뮬레이션을 심도있게 다루고자 한다.

전해조 부하의 고조파 측정 및 평가에 관한 연구 (A Study on the Harmonics Measurement and Assessment of the Electrolyzer Loads)

  • 김경철;이주홍;진성은;박상영;이일무;전영수
    • 조명전기설비학회논문지
    • /
    • 제20권2호
    • /
    • pp.29-37
    • /
    • 2006
  • 중화학 공업은 전해조를 포함한 비선형 부하를 가지고 있다. AC-DC 컨버터가 화학공장의 전해조에 널리 쓰이고 있고, 전해조는 DC에 연결된 구조이다. 컨버터는 고조파 전류를 발생시키고, 전력계통의 전압을 왜곡시킨다. 본 논문에서는 전해조 부하의 고조파 현장 측정과 국제 고조파 관리 기준인 IEC 61000-3-6과 IEEE 519-1992에 의한 고조파 평가를 심도있게 분석한다.

시간에 따라 변하는 고속철 부하의 고조파 측정, 평가 및 시뮬레이션에 관한 연구 (A Study on the Time-varying Harmonics Measurement, Assessment and Simulation of the High Speed Electric Train Loads)

  • 김경철;진성은;이일무;왕용필;곽노홍;전영수;박상호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.78-80
    • /
    • 2006
  • High speed electric trains have nonlinear loads including converters and inverters for the control synchronous motors. Harmonic field measurements have shown that the harmonic contents of a waveform varies with time. Direct application of the harmonic assessment to the snapshot measurements would result in ambiguous conclusions depending on which instant is sampled. A cumulative probabilistic approach is the most commonly used method to solve time varying harmonics. This paper provides an in depth analysis on harmonics field measurement of the high speed electric train loads, harmonics assessment by the international harmonic standards IEC 61000-3-6 and IEEE Std. 519-1992, and harmonics simulation using EDSA program for the case study.

  • PDF

전기로 부하의 고조파 측정, 평가 및 동조필터 적용에 관한 연구 (A Study on the Harmonics Measurement, Assessment and Resonant Filter Application of the Electric Arc Furnace Loads)

  • 김경철;진성은;이주홍
    • 조명전기설비학회논문지
    • /
    • 제20권6호
    • /
    • pp.35-42
    • /
    • 2006
  • 규모가 큰 제철소는 전기로를 포함한 비선형 부하를 가지고 있다. 이들 비선형 부하는 고조파 전류를 발생 시키고, 전력 계통의 전압을 왜곡시킨다. 본 논문에서는 전기로 부하의 고조파 현장 측정, 고조파 저감을 위해 수용가 모선에 동조 필터 적용과 국제 고조파 관리 기준인 IEC 61000-3-6과 IEEE Std. 519에 의한 고조파 평가를 심도 있게 분석한다. 고조파 해석 프로그램인 EDSA는 사례연구에 시뮬레이션 도구로 사용되었다.

전해조 부하의 고조파 측정, 평가 및 동조필터 적용에 관한 연구 (A Study on the Harmonics Measurement, Assessment and Resonant Filter Application of the Electrolyzer Loads)

  • 김경철;진성은;이주홍;서범관;전영수
    • 조명전기설비학회논문지
    • /
    • 제20권4호
    • /
    • pp.12-20
    • /
    • 2006
  • 중화학 공업은 전해조를 포함한 비선형 부하를 가지고 있다. AC-DC 컨버터로 구성된 전해조는 고조파 전류를 발생시키고, 전력 계통의 전압을 왜곡 시킨다. 본 논문에서는 전해조 부하의 고조파 현장 측정, 고조파 저감을 위해 수용가 모선에 동조 필터 적용과 국제 고조파 관리 기준인 IEC 61000-3-6과 IEEE 519에 의한 고조파 평가를 심도있게 분석한다. 고조파 해석 프로그램인 EDSA는 사례연구에 시뮬레이션 도구로 사용되었다.

시간에 따라 변하는 전기로 부하의 고조파 측정 및 평가 (Time-varying Harmonics Measurement and Assessment of the Electric Arc Furnace Loads)

  • 김경철;진성은;박상영;이주홍;이일무;전영수
    • 조명전기설비학회논문지
    • /
    • 제20권1호
    • /
    • pp.91-99
    • /
    • 2006
  • 규모가 큰 제철소는 전기로를 포함한 비선형 부하를 가지고 있고, 고조파 측정 결과 시간에 따라 변하는 고조파 파형이 관측 되었다. 부하 용량이 매우 크기 때문에 전력회사에 미치는 영향이 클 뿐만 아니라 이웃 수용가의 전력시스템에 주는 충격도 고려하여야 한다. 본 논문에서는 시간에 따라 변하는 고조파를 국제 기준인 IEEE 519와 IEC 61000-3-6에 의해 누적확률을 사용하여 평가하였다.

모멘트 정합 방법(Moment Matching Method)을 이용한 전기철도 급전시스템의 고조파 평가 (Harmonics Assessment for an Electric Railroad Feeding System using Moments Matching Method)

  • 이준경;이승혁;김진오
    • 전기학회논문지
    • /
    • 제56권1호
    • /
    • pp.1-7
    • /
    • 2007
  • Generally, an electric railroad feeding system has many problems due to the different characteristics in contrast with a load of general three-phase AC electric power system. One of them is harmonics problem caused by the switching device existing in the feeding system, and moreover, the time-varying dynamic loads of rail way is inherently another cause to increase this harmonics problem. In Korea power systems, the electric railroad feeding system is directly supplied from the substation of KEPCO. Therefore, if voltages fluctuation or unbalanced voltages are created by the voltage and current distortion or voltage drop during operation, it affects directly the source of supply. The trainloads of electric railway system have non-periodic but iterative harmonic characteristics as operating condition, because the electric characteristic of the electric railroad feeding system is changed by physical conditions of the each trainload. According to the traditional study, the estimation of harmonics has been performed by deterministic way using the steady state data at the specific time. This method is easy to analyze harmonics, but it has limits in some cases which needs an assessment of dynamic load and reliability. Therefore, this paper proposes the probabilistic estimation method, moments matching method(MW) in order to overcome the drawback of deterministic method. In this paper, distributions for each harmonics are convolved to obtain the moments and cumulants of TDD(Total Demand Distortion), and this can be generalized for any number of trains. For the case study, the electric railway system of LAT(Intra Airport Transit) in Incheon International Airport is modeled using PSCAD/EMTDC dynamic simulator. The raw data of harmonics for the moments matching method is acquired from simulation of the LAT model.