• 제목/요약/키워드: Harmonic response frequency

검색결과 269건 처리시간 0.022초

Stability analysis of the ball after contacting with the earth in the volleyball game: A multi-physics simulation

  • Yang Sun;Yuhan Lin;Yuehong Ma
    • Structural Engineering and Mechanics
    • /
    • 제85권6호
    • /
    • pp.809-823
    • /
    • 2023
  • In this work, dynamic stability analysis of the ball after contacting with the earth in the volleyball game is presented. Via spherical shell coordinate, the governing equations and general boundary conditions of the ball after contacting with the earth in the volleyball game is studied. Via Comsol multi-physics simulation, some results are presented and a verification between the outcomes is studied. Harmonic differential quadrature method (HDQM) is utilized to solve the dynamic equations with the aid of boundary nodes of the current spherical shell structure. Finally, the results demonstrated that thickness, mass of the ball and internal pressure of the ball alters the frequency response of the structure. One important results of this study is influence of the internal pressure. Higher internal pressure causes lower frequency and hence reduces the stability of the ball.

Experimental study on a new damping device for mitigation of structural vibrations under harmonic excitation

  • Alih, Sophia C.;Vafaei, Mohammadreza;Ismail, Nufail;Pabarja, Ali
    • Earthquakes and Structures
    • /
    • 제14권6호
    • /
    • pp.567-576
    • /
    • 2018
  • This manuscript introduces a new damping device which is composed of a water tank and a pendulum. The new damping device can be tuned to multiple frequencies. In addition, it has a higher energy dissipation capacity when compared with the conventional Tuned Liquid Dampers (TLDs). In order to evaluate the efficiency of this new damping device a series of free vibration and forced vibration tests were conducted on a scaled down single-story one-bay steel frame. Two different configurations were studied for the mass of the pendulum that included a completely and a partially submerged mass. It was observed that the completely submerged configuration led to 44% higher damping ratio when compared with the conventional TLD. In addition, the completely submerged configuration reduced the peak displacement response of the structure 1.6 times more than the conventional TLD. The peak acceleration response of the structure equipped with the new damping device was reduced twice more than the conventional TLD. It was also found that, when the excitation frequency is lower than the resonance frequency, the conventional TLD performs better than the partially submerged configuration of the new damping device.

Dynamic analysis of piezoelectric perforated cantilever bimorph energy harvester via finite element analysis

  • Yousef A. Alessi;Ibrahim Ali;Mashhour A. Alazwari;Khalid Almitani;Alaa A Abdelrahman;Mohamed A. Eltaher
    • Advances in aircraft and spacecraft science
    • /
    • 제10권2호
    • /
    • pp.179-202
    • /
    • 2023
  • This article presents a numerical analysis to investigate the natural frequencies and harmonic response of a perforated cantilever beam attached to two layers of piezoelectric materials by using the finite element method for the first time. The bimorph piezoelectric is composed of 3 layers; two of them at the outer are piezoelectric, and the inner isotropic material. A higher order 3-D 20-node solid element that exhibits quadratic displacement behavior is exploited to discretize the isotropic layer, and coupled piezoelectric 3D element with twenty nodes is used to mesh the top and bottom layers. CIRCU94 element is added to act as a resistor part of the model. The proposed model is validated with previous works. The numerical parametric studies are presented to illustrate the effects of perforation geometry, the number of rows, the resistance on the natural frequencies, frequency response, and power. It is found that the thickness has a positive relationship with the natural frequency. Perforations help in producing higher voltage, and the best shape is rectangular perforations, and to produce higher voltage, two rows of rectangular perforations should be applied.

선박 국부구조의 공진응답 저감을 위한 동흡진기 최적 설계 방법 (Optimal Design Method of Dynamic Vibration Absorber to Reduce Resonant Vibration Response of Ship Local Structure)

  • 권혁;조대승
    • 대한조선학회논문집
    • /
    • 제59권3호
    • /
    • pp.134-140
    • /
    • 2022
  • Ship local structure sometimes experiences severe vibration due to the resonance with an excitation force generated by the propulsion system. In that case, the installation of dynamic vibration absorber such as Tuned Mass Damper (TMD) on the structure can be considered as an effective alternative countermeasure to reduce the troublesome vibration if structural modification or change of excitation frequencies is difficult. Meanwhile, the conventional optimal design method of TMD premises the target structure exposed on an excitation force without the constraint of its magnitude and frequency range. However, the frequencies of major ship excitation forces due to propulsion system are normally bounded and its magnitude is varied according to its operation speed. Hence, the optimal design of TMD to reduce the resonant vibration of ship local structure should be differently approached compared with the conventional ones. For the purpose, this paper proposes an optimal design method of TMD considering maximum frequency and magnitude variation of a target harmonic excitation component. It is done by both lowering the resonant response at the 1st natural frequency and locating the 2nd natural frequency over maximum excitation frequency for the idealized 2 degree of freedom system consisted of the structure and the TMD. For the validation of the proposed method, a numerical design case of TMD for a ship local structure exposed on resonant vibration due to a propeller excitation force is introduced and its performance is compared with the conventionally designed one.

$H_\infty$ 제어를 이용한 방진대의 능동제어 (Active Control of Isolation Table Using $H_\infty$ Control)

  • 김규용;양현석;박영필
    • 대한기계학회논문집A
    • /
    • 제20권10호
    • /
    • pp.3079-3094
    • /
    • 1996
  • Recently, the high-precision vibration attenuation technology becomes the essence fo the seccessful development of high-integrated and ultra-precision industries, and is expected to continue playing a key role in the enhancement of manufacturing technology. Vibration isolation system using an air-spring is widely employed owing to its excellent isolation characteristics in a wide frequency range. It has, however, some drawbacks such as low-stiffness and low-damping features and can be easily excited by exogenous disturbances, and then vibration of table is remained for a long time. Consequently, the need for active vibration control for an air-spring vibration isolation system becomes inevitable. Furthermore, for an air-spring isolation table to be successfully employed in a variety of manufacturing sites, it should have a guaranteed robust performance not only to exogenous disturbances but also to uncertainties due to various equipments which might be put on the table. In this study, an active vibration suppression control system using H.inf. theory is designed and experiments are performed to verify its robust performance. An air-spring vibration isolation table with voice-coil-motors as its actuators is designed and built. The table is modeled as 3 degree-of-freedom system. An active control system is designed based on $H_\infty$control theory using frequency-shaped weighting functions. Analysis on its performance and frequency responce properties are done through numerical simulations. Robust characteristics of$H_\infty$ control on disturbances and model uncertainties are experimentally verified through (i) the transient response to the impact excitation of the table, (ii) the steady-state response to the harmonic excitation, and (iii) the response to the mass change of the table itself. An LQG controller is also designed and its performance is compared with the $H_\infty$ controller.

EDISON Co-rotational Plane Beam-Dynamic Tip Load를 이용한 가진주파수 변화에 따른 외팔보의 자유단 진동 연구 (Study on Cantilever Beam Tip Response with Various Harmonic Frequencies by Using EDISON Co-rotational Plane Beam-Dynamic Tip Load)

  • 박철우;주현식;류한열;신상준
    • 한국전산구조공학회논문집
    • /
    • 제28권5호
    • /
    • pp.477-483
    • /
    • 2015
  • 본 논문에서는 Euler-Bernoulli Beam(EB-beam) 및 신속 Fourier 변환을 이용하여 수치분석적 빔 모델 및 Co-rotational plane beam EDISON program(CR-beam)을 이용한 빔 모델의 가진주파수 변화에 따른 외팔보의 자유단 진동 연구를 수행하였다. 위의 두 빔 모델에서의 끝단에서는 진동이 시간이 지남에 따라 감소하다가 정상상태에 이르는 것을 확인하였다. 끝단에서 가진주파수가 증가함에 따라 구조적 감쇠에 의해 변위이 감소하는 경향을 보인다. 감쇠를 고려한 EB-beam과 CR-beam가 정상상태로 진입하는 경향이 비슷하나, 가진주파수는 정상상태가 나타나는 시간과 독립적임을 제시한다.

무인기용 진동 저감 마운트의 고무 감쇠 특성에 대한 연구 (Study on Rubber Damping Characteristics of Vibration Reduction Mounts for UAVs)

  • 강찬휘;박헌서;곽동기
    • 문화기술의 융합
    • /
    • 제9권6호
    • /
    • pp.927-933
    • /
    • 2023
  • 현대에 들어서 전자 기기와 같은 반도체 기술 발전으로 자동차, 드론, 비행기, 발사체 및 다양한 분야에서 고도화된 전자 부품이 들어간 탑재 장비 품질의 향상과 함께 탑재된 장비에 대한 다양한 외란의 영향을 줄이는 필요성이 더욱 중요해지고 있다. 자동차, 드론, 비행기, 발사체 등과 같이 다양한 환경에서 작동하는 장비의 파손을 방지하고 품질을 향상시키기 위해서는 하드웨어를 통한 진동제어가 선결되어야 한다. 본 연구는 탑재된 장비를 다양한 외란으로부터 보호하고 안정성 향상을 위한 진동 감쇠 시스템 연구에 중점을 두고 있다. 연구 대상인 고무 댐퍼의 특성을 파악하기 위해 압축강성, 감쇠율, 주파수 응답 등을 포함한 동특성 분석 및 고무 댐퍼의 주파수 영역에서의 진동 특성을 FEM 해석을 통해 다양한 주파수 대역에서의 진동 감쇠를 확인 하였다. 이러한 연구 결과를 통해 다양한 외란 조건에서 적합한 고무 댐퍼를 선택하는 기준을 제시하고자 한다.

마이크로컴퓨터를 이용(利用)한 엔진 성능시험(性能試験)의 자동화(自動化)에 관한 연구(硏究)(II) -모의(模擬) 부하시험(負荷試験) 시스템의 구성(構成) 및 평가(評價)- (A Microcomputer-Based Data Acquisition/Control System for Engine Performance Test(II) -Construction and Evaluation of a Load Simulation System-)

  • 류관희;배영환;윤기직
    • Journal of Biosystems Engineering
    • /
    • 제14권1호
    • /
    • pp.1-7
    • /
    • 1989
  • This study was carried out to develop a system and methodology to simulate the engine load variation occuring during agricultural field operations for a laboratory engine test. The system consisted of an electric dynamometer, an Apple II microcomputer, and a data acquisition and control system. Several pieces of instruments were utilized to measure various engine performance data. Both engine torque and engine speed were fully controlled by a computer program. The dynamic characteristics of the system were analyzed through a series of tests and the limitations on the load simulation test were presented. The results of the study are summarized as follows: 1. Engine speed and toque were controlled by a computer program. The use of a stepping motor and reduction gears enabled engine speed be controlled within 1 rpm. 2. The natural frequency of the dynamometer-engine system was found to be around 5 Hz, at which the load simulation would be impossible because of resonance. 3. For the harmonic inputs with the frequencies above the natural frequency, the signal attenuated too much and therefore the load simulation was impossible. 4. The step response of the system showed an overshoot of 24.5 percent and the settling time for 5 percent criterion was around 3 seconds. 5. When actual field test data are utilized for load simulation, a low-pass filter should be included to attenuate the frequency components around and above the natural frequency.

  • PDF

마찰형 감쇠장치가 설치된 실물크기 3층 철골프레임의 진동대 실험 (Shaking Table Test of a Full Scale 3 Story Steel Frame with Friction Dampers)

  • 배춘희;김연환;이상현;박영필
    • 한국소음진동공학회논문집
    • /
    • 제17권9호
    • /
    • pp.862-873
    • /
    • 2007
  • Energy dissipation devices can be considered as an alternative for the seismic performance enhancement of existing structures based on the strengthened seismic design code. In this study, seismic response mitigation effects of friction dampers are investigated through the shaking table test of a full scale 3 story building structure. Frist, the bilinear force-displacement relationship of a structure-brace-friction damper system and the effect of brace-friction damper on the increase of frequency and damping ratio are identified. Second, frequency, displacement, and torque dependent characteristics of the friction damper are investigated by using harmonic load excitation tests. Finally, the shaking table tests are performed for a full scale 3 story steel frame. System identification results using random signal excitation indicated that brace-friction damper increased structural damping ratio and frequency, and El Centro earthquake test showed that brace-friction damper reduced the peak displacement and acceleration significantly. In particular, it was observed that the damping effect due to friction damper becomed obvious when the structure was excited by more intensive load causing frequent slippage of the friction dampers.

대학 기숙사 건물의 안전성 및 사용성 평가 연구 (A Study on the Safety and Usability of University Dormitory Buildings)

  • 채경훈;허석재;허무원
    • 교육시설 논문지
    • /
    • 제26권2호
    • /
    • pp.3-10
    • /
    • 2019
  • This study evaluated the vibration use and safety of students living in the dormitories on the 12th and 14th floors by feeling uncomfortable. The measurement method was to measure the acceleration due to free vibration and single - person walking. The slab stiffness was then calculated, and the usability and safety were compared according to international standards. The natural frequency of the slab was 6.8 Hz. The natural frequency of a typical slab is around 15Hz. Therefore, the evaluation slab is judged as a flexible floor structure. It is considered that there is a high possibility of resonance in the middle of daily life because of low natural frequency and near harmonic component of walking vibration. As a result, the RMS acceleration level is within the tolerance range defined by ISO 10137 code, but the 13th floor exceeds the reference limit, so that a sensitive person could detect the vibration somewhat in the lying position.