• 제목/요약/키워드: Harmonic recovery

검색결과 34건 처리시간 0.019초

X-밴드 고조파 발생기의 구현에 관한 연구 (A Study on the Realization of X-Band Harmonic Generator)

  • 김영범;홍헌진;박동철;오승협
    • 대한전자공학회논문지
    • /
    • 제27권4호
    • /
    • pp.513-519
    • /
    • 1990
  • In order to realize an efficient and stable X-band harmonic generator, a 100 MHz frequency multiplier, an impulse generator using SRD(Step Recovery Diode) module, and a narrow-band bandpass waveguide filter have been designed and tested. By properly combining these devices an X-band harmonic generator has been realized. The output power of the harmonic generator was measured to be -1.5 dBm at 9 GHz which is the 90th harmonic of the 100MHz input. The power fluctuation of the harmonic generator due to temperature variation was observed to the about 0.15 dB during 24 hours of 4\ulcorner temperature variation.

  • PDF

Improved Trigger System for the Suppression of Harmonics and EMI Derived from the Reverse-Recovery Characteristics of a Thyristor

  • Wei, Tianliu;Wang, Qiuyuan;Mao, Chengxiong;Lu, Jiming;Wang, Dan
    • Journal of Power Electronics
    • /
    • 제17권6호
    • /
    • pp.1683-1693
    • /
    • 2017
  • This paper analyses the harmonic pollution to power grids caused by thyristor-controlled devices. It also formulates a mathematic derivation for the voltage spikes in thyristor-controlled branches to explain the harmonic and EMI derived from the reverse-recovery characteristics of the thyristor. With an equivalent nonlinear time-varying voltage source, a detailed simulation model is established, and the periodic dynamic switching characteristic of the thyristor can be explicitly implied. The simulation results are consistent with the probed results from on-site measurements. An improved trigger system with gate-shorted circuit structure is proposed to reduce the voltage spikes that cause EMI. The experimental results indicate that a prototype with the improved trigger system can effectively suppress the voltage spikes.

고조파 복원에 의한 CELP 음성 부호화기의 저대역 확장 (Low-band Extension of CELP Speech Coder by Recovery of Harmonics)

  • 박진수;최무열;김형순
    • 대한음성학회지:말소리
    • /
    • 제49호
    • /
    • pp.63-75
    • /
    • 2004
  • Most existing telephone speech transmitted in current public networks is band-limited to 0.3-3.4 kHz. Compared with wideband speech(0-8 kHz), the narrowband speech lacks low-band (0-0.3 kHz) and high-band(3.4-8 kHz) components of sound. As a result, the speech is characterized by the reduced intelligibility and a muffled quality, and degraded speaker identification. Bandwidth extension is a technique to provide wideband speech quality, which means reconstruction of low-band and high-band components without any additional transmitted information. Our new approach considers to exploit harmonic synthesis method for reconstruction of low-band speech over the CELP coded speech. A spectral distortion measurement and listening test are introduced to assess the proposed method, and the improvement of synthesized speech quality was verified.

  • PDF

Dynamic Coordination Strategies between HVDC and STATCOM

  • Kim, Chan-Ki;Sood, Vijay;Lee, Seok-Jin
    • Journal of Power Electronics
    • /
    • 제9권6호
    • /
    • pp.892-902
    • /
    • 2009
  • This paper deals with the dynamic voltage control problem at the inverter end of a HVDC link when connected to a weak AC system which has the potential for harmonic instability and commutation failures. The dynamic voltage control problem is tackled with a STATCOM (Static Compensator), which not only provides a rapid recovery from harmonic instability and commutation failures but also offers a lower cost filter design for HVDC systems. PSCAD/EMTDC simulations are presented to validate the proposed topology and to demonstrate its robust performance.

스위치모드 컨버터에 의한 새로운 슬립전력 회수시스템 (A New Slip Power Recovery System by Switch Mode Converter)

  • 박한웅;박성준;김철우;황영문
    • 전력전자학회논문지
    • /
    • 제4권1호
    • /
    • pp.73-81
    • /
    • 1999
  • 본 연구에서는 권선형 유도전동기의 회전자회로에 스위치모드 컨버터를 적용시킨 새로운 슬립전력 회수시스템을 제안하고 이를 분석한다. 제안된 시스템의 해석을 통해 적용된 컨버터의 듀티비에 의해 속도가 제어될 수 있으며, 동시에 기존 시스템의 몇가지 특성을 개선할 수 있음을 보인다. 특히 종래 시스템에서 주된 단점으로 되어 있는 저역률 및 전원전류의 고조파성분을 크게 개선할 수 있을 뿐만 아니라 선형적인 속도조절도 가능하다. 제안된 시스템의 타당성을 보이기 위해 이론 및 실험 결과를 제시하고 이를 설명한다.

Simultaneous Unwrapping Phase and Error Recovery from Inhomogeneity (SUPER) for Quantitative Susceptibility Mapping of the Human Brain

  • Yang, Young-Joong;Yoon, Jong-Hyun;Baek, Hyun-Man;Ahn, Chang-Beom
    • Investigative Magnetic Resonance Imaging
    • /
    • 제22권1호
    • /
    • pp.37-49
    • /
    • 2018
  • Purpose: The effect of global inhomogeneity on quantitative susceptibility mapping (QSM) was investigated. A technique referred to as Simultaneous Unwrapping Phase with Error Recovery from inhomogeneity (SUPER) is suggested as a preprocessing to QSM to remove global field inhomogeneity-induced phase by polynomial fitting. Materials and Methods: The effect of global inhomogeneity on QSM was investigated by numerical simulations. Three types of global inhomogeneity were added to the tissue susceptibility phase, and the root mean square error (RMSE) in the susceptibility map was evaluated. In-vivo QSM imaging with volunteers was carried out for 3.0T and 7.0T MRI systems to demonstrate the efficacy of the proposed method. Results: The SUPER technique removed harmonic and non-harmonic global phases. Previously only the harmonic phase was removed by the background phase removal method. The global phase contained a non-harmonic phase due to various experimental and physiological causes, which degraded a susceptibility map. The RMSE in the susceptibility map increased under the influence of global inhomogeneity; while the error was consistent, irrespective of the global inhomogeneity, if the inhomogeneity was corrected by the SUPER technique. In-vivo QSM imaging with volunteers at 3.0T and 7.0T MRI systems showed better definition in small vascular structures and reduced fluctuation and non-uniformity in the frontal lobes, where field inhomogeneity was more severe. Conclusion: Correcting global inhomogeneity using the SUPER technique is an effective way to obtain an accurate susceptibility map on QSM method. Since the susceptibility variations are small quantities in the brain tissue, correction of the inhomogeneity is an essential element for obtaining an accurate QSM.

Recovery Phase Spontaneous Nystagmus, Its Existence and Clinical Implication

  • Lee, Min Young;Son, Hye Ran;Rah, Yoon Chan;Jung, Jae Yun;Suh, Myung-Whan
    • Journal of Audiology & Otology
    • /
    • 제23권1호
    • /
    • pp.33-38
    • /
    • 2019
  • Background and Objectives: Determination of the lesion side based on the direction of the nystagmus could result in confusions to the clinicians due to mismatch between the vestibular function tests and also between vestibular and audiologic features. To minimize these mistakes, we elucidated the clinical manifestation and vestibular function test results in cases with recovery spontaneous nystagmus (rSN). Subjects and Methods: Patients who visited ENT clinic of tertiary referral hospital for acute onset continuous vertigo from January 2008 to December 2011 were enrolled. In these patients, we assessed onset time of vertigo, time point of paralytic spontaneous nystagmus (SN) and time point of rSN. At each time point of SN, vestibular function tests and hearing function tests were performed. Results: We confirmed the rSN among patients with unilateral vestibulopathy and demonstrated that high gain of the rotatory chair test (slow harmonic acceleration) and/or mismatch of the SN direction and contralateral caloric weakness could indicate the recovery state of patients and nystagmus observed in this stage is recovery phase nystagmus. Conclusions: In acute vestibulopathy patients, recovery phase nystagmus was observed and on this stage of disease vestibular function tests shows several features that could predict recovery state.

Recovery Phase Spontaneous Nystagmus, Its Existence and Clinical Implication

  • Lee, Min Young;Son, Hye Ran;Rah, Yoon Chan;Jung, Jae Yun;Suh, Myung-Whan
    • 대한청각학회지
    • /
    • 제23권1호
    • /
    • pp.33-38
    • /
    • 2019
  • Background and Objectives: Determination of the lesion side based on the direction of the nystagmus could result in confusions to the clinicians due to mismatch between the vestibular function tests and also between vestibular and audiologic features. To minimize these mistakes, we elucidated the clinical manifestation and vestibular function test results in cases with recovery spontaneous nystagmus (rSN). Subjects and Methods: Patients who visited ENT clinic of tertiary referral hospital for acute onset continuous vertigo from January 2008 to December 2011 were enrolled. In these patients, we assessed onset time of vertigo, time point of paralytic spontaneous nystagmus (SN) and time point of rSN. At each time point of SN, vestibular function tests and hearing function tests were performed. Results: We confirmed the rSN among patients with unilateral vestibulopathy and demonstrated that high gain of the rotatory chair test (slow harmonic acceleration) and/or mismatch of the SN direction and contralateral caloric weakness could indicate the recovery state of patients and nystagmus observed in this stage is recovery phase nystagmus. Conclusions: In acute vestibulopathy patients, recovery phase nystagmus was observed and on this stage of disease vestibular function tests shows several features that could predict recovery state.

유도전동기의 고성능 슬립전력 회수방식에 대한 연구 (A Study on the High Performance Slip Power Recovery System in Induction Motor)

  • 박한웅;박성진;안진우;박진길;김철우;황명문
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권8호
    • /
    • pp.431-439
    • /
    • 1999
  • Among the variable-speed AC motor drive systems, the static slip power recovery system has been widely adopted in large power drives because a high efficiency drive can be obtained by recovering the slip power to the AC line. Although many improvements have been made in this system, several problems also remain such as the need of transformer in inverter AC side, which results in limiting speed control range and increasing the losses, production of reactive power by the control of inverter firing angle, harmonics in line currents, and so on. This paper presents the novel high performance slip power recovery system using the boost converter and small size filter in the rotor circuit, which recovers slip power of a wound rotor induction machine to AC supply efficiently with the aid of the boost converter, in which most of the problems in conventional system can be solved. The speed can be controlled by the duty ratio of the converter switch, not by inverter firing angle. As a results, the proposed system can operate in high power factor and the harmonic currents caused by the inverter and rectifier can be considerably suppressed. The validity of the proposed system verified by demonstrating the good agreement in the simulation and experimental results.

  • PDF

Detailed Design of an Active Rotor Blade for Reducing Helicopter Vibratory Loads

  • Natarajan, Balakumaran;Eun, Won-Jong;Shin, Sang-Joon
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 추계학술대회 논문집
    • /
    • pp.236-241
    • /
    • 2011
  • An active trailing-edge flap blade named as Seoul National University Flap (SNUF) blade is designed for reducing helicopter vibratory loads and the relevant aeroacoustic noise. Unlike the conventional rotor control, which is restricted to 1/rev frequency, an active control device like the present trailing-edge flap is capable of actuating each individual blade at higher harmonic frequencies i.e., higher harmonic control (HHC) of rotor. The proposed blade is a small scale blade and rotates at higher RPM. The flap actuation components are located inside the blade and additional structures are included for reinforcement. Initially, the blade cross-section design is determined. The aerodynamic loads are predicted using a comprehensive rotorcraft analysis code. The structural integrity of the active blade is verified using a stress-strain recovery analysis.

  • PDF