• Title/Summary/Keyword: Harmonic measurements

Search Result 128, Processing Time 0.028 seconds

A Technique of Large Signal Modeling of PIN Diode through Measurements (측정을 통한 PIN 다이오드 대신호 모델 구축 기법)

  • Yang, Seong-Sik;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.1
    • /
    • pp.12-20
    • /
    • 2009
  • In this paper, we introduced the large signal model of a PIN diode and presented the measurement methods for each parameter of the large signal model. The elements of the PIN diode model are classified into the elements with a constant value and the elements depending on the junction voltage. We implemented the constant elements by lumped elements and the voltage-dependent elements by a SDD in ADS. The developed large signal model was successfully worked with various circuit simulations, such as simple DC, AC, S-parameter, Transient, and HB simulations. In order to verify the developed large signal model, we compared that the measured results of a limiter and a attenuator with the simulated results using the PIN diode model, which are in good agreement.

Conductivity Imaging of a Canine Head using a 3T MREIT System with a Carbon-Hydrogel Electrode: Postmortem Experiment (3T MREIT 시스템을 이용한 실험견 사체의 두부 도전율 영상)

  • Jeong, Woo-Chul;Kim, Young-Tae;Minhas, Atul S.;Kim, Hyung-Joong;Lee, Tae-Hwi;Kang, Byeong-Teck;Park, Hee-Myung;Woo, Eung-Je
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.2
    • /
    • pp.179-184
    • /
    • 2009
  • Magnetic Resonance Electrical Impedance Tomography (MREIT) is a new bio-imaging modality providing cross-sectional conductivity images from measurements of internal magnetic flux densities produced by externally injected currents. Recent MREIT studies demonstrated successful conductivity image reconstructions of postmortem and in vivo canine brain. However, the whole head imaging was not achieved due to technical issues related with electrodes and noise in measured magnetic flux density data. In this study, we used a new carbon-hydrogel electrode with a large contact area and injected 30 mA imaging current through a canine head. Using a 3T MREIT system, we performed a postmortem canine experiment and produced high-resolution conductivity images of the entire canine head. Collecting magnetic flux density data inside the head subject to multiple injection currents, we reconstructed cross-sectional conductivity images using the harmonic $B_z$ algorithm. The conductivity images of the canine head show a good contrast not only inside the brain region including white and gray matter but also outside the brain region including the skull, temporalis muscle, mandible, lingualis proprius muscle, and masseter muscle.

Development of New Monitoring System for Power Quality Management (새로운 전기품질 감시장치 개발 및 전기품질 관리방안)

  • Nam, Kee-Young;Choi, Sang-Bong;Ryoo, Hee-Suk;Lee, Jae-Duck;Jeong, Seong-Hwan;Kim, Dae-Kyung
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.447-449
    • /
    • 2005
  • Power supply system & environment have been changed according to the universal global electrification, the pursuit of improving productivity and the convenience of life. The various kinds of modem electric facilities and almost of all kinds of digital devices embedded microprocessor are very sensitive to the supplied power quality variations. So, they are stopped and result in large economic damage when even the deterioration of power quality with short duration is occurred, which was not so fatal to the conventional industrial facilities and devices. Conversely, those facilities and digital devices generate many kinds of power quality problems such as harmonic.;, flicker, voltage drop, etc. This paper presents the status of power quality and outlines the development of a new power quality monitoring system based on the experience of a series of authors' researches and field measurements for industrial customers in Korea. It also proposes the functions of the monitoring device and the efficient analysis method based on the Korean electrical act and international standards on power quality. Finally, the authors suggest some countermeasures for advancing the power quality to cope with the competitive electric power market and customers' needs after domestic restructuring of electric power industry.

  • PDF

Ferroelectric and Antiferroelectric Behavior in Chiral Bent-shaped Molecules with an Asymmetric Central Naphthalene Core

  • Lee, Seng-Kue;Tokita, Masatoshi;Shimbo, Yoshio;Kang, Kyung-Tae;Takezoe, Hideo;Watanabe, Junji
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.12
    • /
    • pp.2241-2247
    • /
    • 2007
  • A new series of chiral bent-shaped liquid crystals with an asymmetric central core based on 1,6- dihydroxynaphthalene and chiral terminal chain prepared from (S)-(?)-2-methyl-1-butanol, 1,6-naphthalene bis[4-(4-alkoxyphenyliminomethyl)]benzoates [N(1,6)-n-O-PIMB(n-2)*-(n-4)O (n = 8-11)] were synthesized. Their mesomorphic properties and phase structures were investigated by means of electro-optical, polarization reversal current, and second harmonic generation measurements in order to confirm the relationship between the molecular structure and phase structure. All odd n (n = 9 and 11) compounds, N(1,6)-9-O-PIMB7*-5O and N(1,6)-11-O-PIMB9*-7O exhibit antiferroelectric phase, whereas even n (n = 8 and 10) compounds was flexible, N(1,6)-10-O-PIMB8*-6O exhibits the ferroelectric phase but N(1,6)-8-O-PIMB6*-4O exhibits the antiferroelectric phase. These results come from the decrease of the closed packing efficiency within a layer and the lack of uniform interlayer interaction between adjacent layers, which were caused by the asymmetrical naphthalene central core. Thus, we concluded that the structure of central core as well as the terminal chain plays an important role for the emergence of particular polar ordering in phase structures.

The Dynamic Characteristics and Serviceability of Long Span Multi-purpose Hall (장스팬 다목적 홀의 동적특성과 사용성)

  • Lee, Sung-Min;Choi, Chui-Kyung;An, Young-Ki;Lee, Soo-Gon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.7 no.2
    • /
    • pp.105-113
    • /
    • 2003
  • Because structural systems are becoming lighter and more flexible and have lower natural frequencies and dampings than before, coordinated rhythmic activities such as dancing, audience participation in arenas or concert halls, and aerobics result in undesirable levels of vibration. For rhythmic activities, it is resonant or near resonant behavior that result in significant dynamic amplification and hence human discomfort. The most rational design strategy is to provide enough of a gap between the natural frequency of a floor system and the dominant frequencies excited by planned human activities to assure reasonably that resonance will not occur. For the case study the vibration measurements were performed at the floor of a long-span multi-purpose hall during the rock concert of popular singer.

Performance evaluation method of homogeneous stereo camera system for full-field structural deformation estimation

  • Yun, Jong-Min;Kim, Ho-Young;Han, Jae-Hung;Kim, Hong-Il;Kwon, Hyuk-Jun
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.16 no.3
    • /
    • pp.380-393
    • /
    • 2015
  • This study presents how we can evaluate stereo camera systems for the structural deformation monitoring. A stereo camera system, consisting of a set of stereo cameras and reflective markers attached on the structure, is introduced for the measurement and the stereo pattern recognition (SPR) method is utilized for the full-field structural deformation estimation. Performance of this measurement system depends on many parameters including types and specifications of the cameras, locations and orientations of them, and sizes and positions of markers; it is difficult to experimentally identify the effects of each parameter on the measurement performance. In this study, a simulation framework for evaluating performance of the stereo camera systems with various parameters has been developed. The maximum normalized root-mean-square (RMS) error is defined as a representative index of stereo camera system performance. A plate structure is chosen for an introductory example. Its several modal harmonic vibrations are generated and estimated in the simulation framework. Two cases of simulations are conducted to see the effects of camera locations and the resolutions of the cameras. An experimental validation is carried out for a few selected cases from the simulations. Using the simultaneous laser displacement sensor (LDS) measurements as the reference, the measurement errors are obtained and compared with the simulations.

Measurement of Absolute Displacement-Amplitude of Ultrasonic Wave Using Piezo-Electric Detection Method (압전형 수신 기법을 이용한 초음파 절대변위진폭 측정)

  • Park, Seong-Hyun;Kim, Jongbeom;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.37 no.1
    • /
    • pp.7-12
    • /
    • 2017
  • A nonlinear ultrasonic parameter is defined by the ratio of displacement amplitude of the fundamental frequency component to that of the second-order harmonic frequency component. In this study, the ultrasonic displacement amplitude of an SUS316 specimen was measured via a piezo-electric-based method to identify the validity of piezo-electric detection method. For comparison, the ultrasonic displacement was also determined via a laser-based Fabry-Pérot interferometer. The experimental results for both measurements were in good agreement. Additionally, the stability of the repeated test results from the piezo-electric method exceeded that of the laser-interferometric method. This result indicated that the piezo-electric detection method can be utilized to measure a nonlinear ultrasonic parameter due to its excellent stability although it involves a complicated process.

Studies on Voice Changes Associated with Alcohol Intake (음주에 따른 음성 변화에 대한 고찰)

  • Kim, Jung-Hyun;Yoon, Je-Hwan;Cho, Hyung-Ho;Cho, Yeon;Cho, Jae-Sik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.13 no.1
    • /
    • pp.18-22
    • /
    • 2002
  • Background and Objectives : It has been pointed out that alcohol intake in human beings induces changes in voice register and maximum phonation time. These changes supposedly result from injection of the vibratory vocal folds. The purpose of this study was to clarify the voice changes associated with alcohol intake and the changes of laryngeal mucosa. Materials and Methods : The subjects included 29 volunteers, including 20 men and 9 women ranging in age from 22 to 31 years. Alcohol intake was accomplished by oral administration of 23% soju 1 bottle (255cc). Serum alcohol concentration levels were evaluated hourly for 3 h after ingestion of alcohol. Seven measurements were performed at pre-alcohol intake and post-alcohol intake hourly : fundamental frequency, jitter, shimmer, noise to harmonic ratio as the acoustic analysis, maximal phonation time, mean flow rate, and subglottal pressure as the aerodynamic analysis. The changes of laryngeal mucosa were evaluated by flexible laryngoscope at each measurement. Results : By comparing the acoustic and aerodynamic data and laryngeal mucosa before and after alcohol intake, there were not remarkable changes (p>0.05). Conclusion : The voice and laryngeal mucosa have not remarkably changed according to alcohol concentration in this study. Furthermore studies on the voice change induced by multiple alcohol concentrations are required.

  • PDF

Compressible Simulation of Rotor-Stator Interaction in Pump-Turbines

  • Yan, Jianping;Koutnik, Jiri;Seidel, Ulrich;Hubner, Bjorn
    • International Journal of Fluid Machinery and Systems
    • /
    • v.3 no.4
    • /
    • pp.315-323
    • /
    • 2010
  • This work investigates the influence of water compressibility on pressure pulsations induced by rotor-stator interaction (RSI) in hydraulic machinery, using the commercial CFD solver ANSYS-CFX. A pipe flow example with harmonic velocity excitation at the inlet plane is simulated using different grid densities and time step sizes. Results are compared with a validated code for hydraulic networks (SIMSEN). Subsequently, the solution procedure is applied to a simplified 2.5-dimensional pump-turbine configuration in prototype with different speeds of sound as well as in model scale with an adapted speed of sound. Pressure fluctuations are compared with numerical and experimental data based on prototype scale. The good agreement indicates that the scaling of acoustic effects with an adapted speed of sound works well. With respect to pressure fluctuation amplitudes along the centerline of runner channels, incompressible solutions exhibit a linear decrease while compressible solutions exhibit sinusoidal distributions with maximum values at half the channel length, coinciding with analytical solutions of one-dimensional acoustics. Furthermore, in compressible simulation the amplification of pressure fluctuations is observed from the inlet of stay vane channels to the spiral case wall. Finally, the procedure is applied to a three-dimensional pump configuration in model scale with adapted speed of sound. Normalized Pressure fluctuations are compared with results from prototype measurements. Compared to incompressible computations, compressible simulations provide similar pressure fluctuations in vaneless space, but pressure fluctuations in spiral case and penstock may be much higher.

Determination of individual sugars in different varieties of persian grape using Near Infrared spectroscopy

  • Kargosha, Kazem;Azad, Jila;Lary, Abas Motamed
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1527-1527
    • /
    • 2001
  • Glucose, fructose and sucrose being the main sugars that can be found in natural fruit juice. Many instrumental methods, such as GC, LC, electrochemical or spectrometric methods provide information about both the total content of sugars and the specific concentration of each carbohydrate[1]. The simplicity of sample handling and measurement in the near IR(NIR) wavelength region, which allows the use of long pathlength, optical glass cells and optical fibers, makes NIR a good alternative for sugar determination [2]. In the present study, six varieties of persian grapes were harvested at intervals through august to october and analysed for sugars by NIR. The results were processed by principal component regression (PCR) and partial least squares (PLS) analysis. Sample juice was prepared by squeezing through gauze from crashed grape. This solution was treated by zinc ferrocyanide prior to analysis in order to eliminate colored compounds and all optically active nonsugar substances. For glucose and fructose the most characteristic wavelengths were 1456nm corresponding to the first harmonic O-H stretching and the second at 2062nm corresponding to O-H stretching and deformation; secondary characteristic combination bands were also seen at 2265 nm (O-H and C-C stretching) and at 2240 nm (C-H and C-C stretching). However these spectra were taken over a wavelength range from 1100-2500nm at room temperature of 25-$30^{\circ}C$. To test the accuracy of the described procedure, samples of six varieties of grape were analysed by the proposed NIR and a standard method[2]. Good agreement were found between these two sets of the results. To perform the recovery studies , samples of grape juices previously analysed by the proposed method, were spiked with known amounts of each individual sugars and then analysed again. Relative standard deviations varied from 1.4 to 1.8% for six independent measurements of individual and total sugar concentration. In the analysis of real and synthetic samples, precise and accurate results were obtained , providing accuracy errors lower than 1.9% in all cases. Average recoveries of ${97}{\pm}{4%}$ for total sugar and between ${95}{\pm}{5%}$ and ${99}{\pm}{2%}$ for sing1e sugars demonstrate the applicability of the methodology developed to the direct analysis of grape Juice.

  • PDF