• 제목/요약/키워드: Harmonic Generation Technique

검색결과 58건 처리시간 0.025초

Harmonic Current Compensation Using Active Power Filter Based on Model Predictive Control Technology

  • Adam, Misbawu;Chen, Yuepeng;Deng, Xiangtian
    • Journal of Power Electronics
    • /
    • 제18권6호
    • /
    • pp.1889-1900
    • /
    • 2018
  • Harmonic current mitigation is vital in power distribution networks owing to the inflow of nonlinear loads, distributed generation, and renewable energy sources. The active power filter (APF) is the current electrical equipment that can dynamically compensate for harmonic distortion and eliminate asymmetrical loads. The compensation performance of an APF largely depends on the control strategy applied to the voltage source inverter (VSI). Model predictive control (MPC) has been demonstrated to be one of the effective control approaches to providing fast dynamic responses. This approach covers different types of power converters due to its several advantages, such as flexible control scheme and simple inclusion of nonlinearities and constraints within the controller design. In this study, a finite control set-MPC technique is proposed for the control of VSIs. Unlike conventional control methods, the proposed technique uses a discrete time model of the shunt APF to predict the future behavior of harmonic currents and determine the cost function so as to optimize current errors through the selection of appropriate switching states. The viability of this strategy in terms of harmonic mitigation is verified in MATLAB/Simulink. Experimental results show that MPC performs well in terms of reduced total harmonic distortion and is effective in APFs.

Efficient Hybrid Carrier Based Space Vector Modulation for a Cascaded Multilevel Inverter

  • Govindaraju, C.;Baskaran, K.
    • Journal of Power Electronics
    • /
    • 제10권3호
    • /
    • pp.277-284
    • /
    • 2010
  • This paper presents a novel hybrid carrier based space vector modulation for cascaded multilevel inverters. The proposed technique inherits the properties of carrier based space vector modulation and the fundamental frequency modulation strategy. The main characteristic of this modulation are the reduction of power loss, and improved harmonic performance. The carrier based space vector modulation algorithm is implemented with a TMS320F2407 digital signal processor. A Xilinx Complex Programmable Logic Device is used to develop the hybrid PWM control algorithm and it is integrated with a digital signal processor for hybrid carrier based space vector PWM generation. The inverter offers less weighted total harmonic distortion and it operates with equal electrostatic and electromagnetic stress among the power devices. The feasibility of the proposed technique is verified by spectral analysis, simulation, and experimental results.

Nonlinear Time Reversal Focusing and Detection of Fatigue Crack

  • Jeong, Hyun-Jo;Barnard, Dan
    • 비파괴검사학회지
    • /
    • 제32권4호
    • /
    • pp.355-361
    • /
    • 2012
  • This paper presents an experimental study on the detection and location of nonlinear scattering source due to the presence of fatigue crack in a laboratory specimen. The proposed technique is based on a combination of nonlinear elastic wave spectroscopy(NEWS) and time reversal(TR) focusing approach. In order to focus on the nonlinear scattering position due to the fatigue crack, we employed only one transmitting transducer and one receiving transducer, taking advantage of long duration of reception signal that includes multiple linear scattering such as mode conversion and boundary reflections. NEWS technique was then used as a pre-treatment of TR for spatial focusing of reemitted second harmonic signal. The robustness of this approach was demonstrated on a cracked specimen and the nonlinear TR focusing behavior is observed on the crack interface from which the second harmonic signal was originated.

계통연계형 태양광발전 시스템이 계통의 전력품질에 미치는 영향 (Effect of the Interconnected Solar Power Generation System on the Power Quality of Power System)

  • 권동철;박중신;이동영
    • 조명전기설비학회논문지
    • /
    • 제26권7호
    • /
    • pp.52-58
    • /
    • 2012
  • In this study, we have investigated the effect of the solar power generation facilities on the power quality of interconnected solar power generation system. When the solar power generation facility was connected to the distribution system, whether the solar power generation is under operation or not, Peak factor of current was increased to 0.033[%], Frequency is deviated from $60{\pm}0.2$[Hz] and also Short term flicker indication($P_{st}$) increased to 0.213[p.u.] compare with the disconnected situation. Harmonic current [%] in orders was 11.42[%] maximum under 11th orders and was 7.861[%] between 11th and 17th orders. These values were about 3 or 4 times compared with "the power system interconnection technique standards" at the same situation above. Therefore, we could confirmed that the solar power generation facility, when it was connected to the existing distribution system, made bad influence on the power qualities such as the peak factor of current, frequency regulation, short term flicker indication($P_{st}$) and harmonic current [%] in orders etc.

$YCa_4O(BO_3)_3$ 비선형광학 단결정 성장 및 Second Harmonic Generation 소자 제조에 관한 연구 (Crystal Growth of $YCa_4O(BO_3)_3$ and Preparation of Device for Second Harmonic Generation)

  • 유영문;;장석종;장원권;임기수
    • 한국결정학회지
    • /
    • 제11권1호
    • /
    • pp.16-21
    • /
    • 2000
  • (Yb/sub x/Y/sub 1-x/)Ca₄O(BO₃)₃ single crystals where x=0.3,8,15,20% were grown by Czochralski Method. The crystals grown under the optimum conditions were transparent and colorless with good crystal form. Using polarizing microscope, crystal defects such as parasite crystals and bubbles were detected depending on the composition of melts and pulling rates. The optimum growth parameters for high quality of single crystals were 15∼20 rpm of rotation rate and 2mm/h of pulling rate at the flow rate of 2 l/min of Nitrogen gas. The relationship between crystal axes and optical axes was investigated by optical crystallographic method, polarization technique and single crystal X-ray method. From the spectroscopic measurements, it was confirmed that there were strong absorption bands at 900 and 976.4 nm and strong emission band at 976.4 nm in Yb/sup 3+/ ion doped YCa₄O(BO₃)₃ crystal. For the application of second harmonic generation of 1.064 ㎛ laser, non-linear optical devices with θ=32.32° and Ψ=0°, λ/10 of flatness and the size of 6x8x5.73 mm were fabricated from the grown YCa₄O(BO₃)₃ crystal.

  • PDF

장기유출량의 추계학적 모의 발생에 관한 연구 (II) (Studies on the Stochastic Generation of Long Term Runoff (2))

  • 이순혁;맹승진;박종국
    • 한국농공학회지
    • /
    • 제35권3호
    • /
    • pp.117-129
    • /
    • 1993
  • This study was conducted to get reasonable and abundant hydrological time series of monthly flows simulated by a best fitting stochastic simulation model for the establishment of rational design and the rationalization of management for agricultural hydraulic structures including reservoirs. Comparative analysis carried out for both statistical characteristics and synthetic monthly flows simulated by the multi-season first order Markov model based on Gamma distribution which is confirmed as good one in the first report of this study and by Harmonic synthetic model analyzed in this report for the six watersheds of Yeong San and Seom Jin river systems. 1.Arithmetic mean values of synthetic monthly flows simulated by Gamma distribution are much closer to the results of the observed data than those of Harmonic synthetic model in the applied watersheds. 2.In comparison with the coefficients of variation, index of fluctuation for monthly flows simulated by two kinds of synthetic models, those based on Gamma distribution are appeared closer to the observed data than those of Harmonic synthetic model both in Yeong San and Seom Jin river systems. 3.It was found that synthetic monthly flows based on Gamma distribution are considered to give better results than those of Harmonic synthetic model in the applied watersheds. 4.Continuation studies by comparison with other simulation techniques are to be desired for getting reasonable generation technique of synthetic monthly flows for the various river systems in Korea.

  • PDF

고속전철용 단상능동필터의 기준고조파전류 발생 방법 (Harmonic Current Reference Generation of Single-Phase Active Filter for the Converter-Fed Locomotives)

  • 성기석;송중호;최익;최주엽;김광배;김권호;임묘택
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.338-341
    • /
    • 1999
  • PWM controlled line-side converters of modern ac traction locomotives inject harmonic currents into the feeding overhead line. This causes problem of electromagnetic interference. Passive and Active filters are usually provided for a reduction of the line harmonics. Active filters are more reasonable than passive filters in terms of weight and space of the filters. Successful control of active filters requires an accurate harmonic current reference. A technique to generate the harmonic current reference is proposed in this paper. The analysis is performed in frequency domain and its effectiveness is verified by simulation.

  • PDF

Long-Term Aging Diagnosis of Rotor Steel Using Acoustic Nonlinearity

  • Kim, Chung-Seok;Park, Ik-Keun;Jhang, Kyung-Young;Hyun, Chang-Yong
    • 비파괴검사학회지
    • /
    • 제31권6호
    • /
    • pp.642-649
    • /
    • 2011
  • The long-term aging of ferritic 2.25CrMo steel was characterized using the acoustic nonlinear effect in order to apply to diagnose the degradation behavior of structural materials. We measured the acoustic nonlinearity parameter for each thermally aged specimen by the higher harmonic-generation technique. The acoustic nonlinearity parameter increased with aging time due to equilibrium M6C carbide precipitation, and has a favorable linear relation with Rockwell hardness. This study suggests that acoustic nonlinearity testing may be applicable to diagnostics on strength degradation in rotor steels.

Second Harmonic Generation study on the transport dynamics of small molecules across liposome bilayers

  • Kim, Joon-Heon;Kim, Mahn-Won
    • 한국생물물리학회:학술대회논문집
    • /
    • 한국생물물리학회 2003년도 정기총회 및 학술발표회
    • /
    • pp.79-79
    • /
    • 2003
  • SHG (Second harmonic generation) can be used to probe the surface of centrosymmetric particles suspended in bulk isotropic solution, because it is forbidden in centrosymmetric media under the dipole approximation. Using this technique, we can study the transport dynamics of small organic dye molecules across liposome bilayers. Because molecules adsorbed on the outer layer are in opposite direction with that on the inner layer by symmetry, the SH field is proportional to the difference between the number density of dye molecules on both sides of the bilayer, and the time dependence of the SH intensity is related to the time constant of the molecular transportation of dye molecules across liposome bilayers.

  • PDF

Optical Third-Harmonic Generation of Poly(2-Bromo-1,4-phenylenevinylene)

  • Hwang Do-Hoon;Lee Jeong-Ik;Lee Minyung;Shim Hong-Ku
    • Bulletin of the Korean Chemical Society
    • /
    • 제15권1호
    • /
    • pp.25-28
    • /
    • 1994
  • Weakly electron withdrawing bromine substituted poly(2-bromo-1,4-phenylenevinylene) (PBrPV) was synthesized th-rough water-soluble precursor method. The linear and nonlinear optical properties of PBrPV were compared with those of poly(1,4-phenylenevinylene) (PPV). The third-order nonlinear optical susceptibility, X^{(3)}$, was measured by using third-harmonic generation (THG) technique at 1907 nm, fundamental wavelength. The calculated $X^{(3)}$ values of PPV and PBrPV were 3${\times}$ 10$^{-12}$ esu and 2${\times}$10$^{-12}$ esu, respectively.