• Title/Summary/Keyword: Harmonic Currents

Search Result 343, Processing Time 0.024 seconds

Analysis on the Harmonics Characteristics Due to Increase & Decrease of Nonlinear Load (비선형 부하의 증감에 따른 고조파 특성 분석)

  • Kim, Jong-Gyeum;Lee, Eun-Woong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.52 no.3
    • /
    • pp.100-106
    • /
    • 2003
  • The increasing application of power electronic equipment in industrial field has led to a growing concern for harmonic distortion and the resulting impacts on system equipment and operations. Harmonic currents are generated by the operation of nonlinear loads and equipment on the power system. These are more increased by unbalance voltage of electrical distribution power systems. This paper describes harmonics characteristics generated by varying of nonlinear load at the PCC under the voltage unbalance.

Optimum Air-Gap Flux Distribution with Third Harmonic Rotor Flux Orientation Adjustment for Five-Phase Induction Motor

  • Kang, Min;Yu, Wenjuan;Wang, Zhengyu;Kong, Wubin;Xiao, Ye
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.315-325
    • /
    • 2018
  • This paper investigates optimum air-gap flux distribution with third harmonic rotor flux orientation adjustment for five-phase induction motor. The technique of objective is to generate a nearly rectangular air-gap flux, and it improves iron utilization under variation loading conditions. The proportional relations between third harmonic and fundamental plane currents is usually adopted in the conventional method. However, misalignment between fundamental and third harmonic component occurs with variation loading. The iron of stator teeth is saturated due to this misalignment. This problem is solved by third harmonic rotor flux orientation adjustment simultaneously, and direction and amplitude are changed with mechanical load variation. The proposed method ensures that the air-gap flux density is near rectangular for a maximum value from no load to rated load. It is confirmed that the proposed method guarantees complete both planes decoupling with third harmonic flux orientation adjustment. The effectiveness of the proposed technique is validated experimentally.

Harmonic Current Compensation Using Active Power Filter Based on Model Predictive Control Technology

  • Adam, Misbawu;Chen, Yuepeng;Deng, Xiangtian
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1889-1900
    • /
    • 2018
  • Harmonic current mitigation is vital in power distribution networks owing to the inflow of nonlinear loads, distributed generation, and renewable energy sources. The active power filter (APF) is the current electrical equipment that can dynamically compensate for harmonic distortion and eliminate asymmetrical loads. The compensation performance of an APF largely depends on the control strategy applied to the voltage source inverter (VSI). Model predictive control (MPC) has been demonstrated to be one of the effective control approaches to providing fast dynamic responses. This approach covers different types of power converters due to its several advantages, such as flexible control scheme and simple inclusion of nonlinearities and constraints within the controller design. In this study, a finite control set-MPC technique is proposed for the control of VSIs. Unlike conventional control methods, the proposed technique uses a discrete time model of the shunt APF to predict the future behavior of harmonic currents and determine the cost function so as to optimize current errors through the selection of appropriate switching states. The viability of this strategy in terms of harmonic mitigation is verified in MATLAB/Simulink. Experimental results show that MPC performs well in terms of reduced total harmonic distortion and is effective in APFs.

A Harmonic Circulation Current Reduction Method for Parallel Operation of UPS with a Three-Phase PWM Inverter

  • Kim Kyung-Hwan;Kim Wook-Dong;Hyun Dong-Suk
    • Journal of Power Electronics
    • /
    • v.5 no.2
    • /
    • pp.160-165
    • /
    • 2005
  • In a parallel operation of UPS, there are two types of circulating currents between UPS. One is the low order circulating current with a fundamental frequency caused by the amplitude and phase differences of UPS output voltages, and the other is the harmonic circulating current with PWM switching frequency caused by non-synchronized PWM waveforms among UPS. The elimination of the low order circulating current is essential for optimal load sharing in parallel operations of UPS, which can be accomplished by the phase and magnitude control at each UPS. The harmonic circulating current may cause troubles and deteriorate in performance of the controller for optimal load sharing in parallel operation of UPS. This paper presents a PWM synchronizing method to eliminate the harmonic circulation current in parallel operation of UPS. The effectiveness of the proposed scheme has been investigated and verified through experiments by a 50kVA UPS.

Harmonic Reduction of Three Phase Multi-Pulse Converter Circuit without Input Transformer (입력 변압기 없는 3상 멀티-펄스 콘버터의 고조파 저감)

  • Park, Hyun-Chul;Kim, Yeong-Min;Hwang, Jong-Sun;Kim, Jong-Man
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05b
    • /
    • pp.128-131
    • /
    • 2002
  • In this paper, a new method for reducing harmonic in input AC line currents of converter presents, which is the multi-pulse converter circuit without the input transformer. This system can reduce the harmonic like conventional 12-pulse converter. Both the bridge circuits are controlled with the shifted firing angle and connected 2 tap inter-phase reactor. Using 2 tap changing on inter-phase reactor, the input current is controlled with the different two values in order to make the input current waveform 12 pulses.

  • PDF

Characteristics Analysis of Induction Motor by Operation of Non-lineal Loads (비선형 부하의 운전시 유도전동기의 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2006.10b
    • /
    • pp.147-153
    • /
    • 2006
  • Voltage unbalance will be generated by the load unbalance operation such as combination operation of single & three phase load and current unbalance will be more severe by the deteriorated voltage quality. Under the these unbalance conditions, all power electronic converters used in different types of electronic systems can increase harmonic disturbances by injecting harmonic currents directly into the feeder grid of three phase 4-wire. Harmonic current may cause torque to decrease. it may also overheat or become noisy and torque oscillation in the rotor can lead to mechanical resonance and vibration. This paper presents a scheme on the characteristics of induction motor under the combination of linear & non-linear loads at the three phase 4-wire power distribution system by the unbalance and harmonic components. It was able to confirm that the number of torque pulsation decreased and torque ripple values increased by the harmonics that reduction was difficult by five harmonics filters at additional driving time of single-phase non-linear load.

  • PDF

The Method for Harmonics Elimination of a Single Phase Current by the Analog Relay Control Circuit and Passive Filters (릴레이 구동회로 및 수동필터를 이용한 단상 전원의 부하 적응형 고조파 전류 제거 기법)

  • Park, Jong-Yeon;Lee, Hu-Chan;Lee, Bong-Jin;Choi, Won-Ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.6
    • /
    • pp.292-298
    • /
    • 2006
  • Because of the high cost for the active power filter, passive filters have been widly used to eliminate harmonic currents of nonlinear load and can also improve the power factor. They are not often optimal filters because the passive filters are designed under the fixed load conditions. In this paper we proposed the method which only the necessary harmonic filters are operated by detecting the various harmonic current components. We presents the new control method of passive filter selection type with the relay control circuit which is consist of analog GIC, comparater, flip-flop and etc. By the experimental results using the proposed system for the rectifier load, we concluded that the researched method is cost effective and the performance is better than the passive filter.

Compensation of Source Voltage Unbalance and Current Harmonics in Series Active and Shunt Passive Power Filters

  • Lee G-Myoung;Lee Dong-Choon
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.586-590
    • /
    • 2001
  • In this paper, a novel control scheme compensating source voltage unbalance and harmonic currents for hybrid active power filters is proposed, where no low/high-pass filters are used in compensation voltage composition. The phase angle and compensation voltages for source harmonic current and unbalanced voltage components are derived from the positive sequence component of the unbalanced voltage set, which is simply obtained by using digital all-pass filters. Since a balanced set of the source voltage obtained by scaling the positive sequence components is used as reference values for source current and load voltage, it is possible to eliminate the necessity of low/high-pass filters in the reference generation. Therefore the control algorithm is much simpler and gives more stable performance than the conventional method. In addition, the source harmonic current is eliminated by compensating for the harmonic voltage of the load side added to feedback control of the fundamental component.

  • PDF

A Study on the Harmonics Reduction using Phase Shifting Transformer in a Electric Power Distribution System (배전계통에서 위상조정 변압기를 사용한 고조파 저감에 관한 연구)

  • 김경철
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.2
    • /
    • pp.38-44
    • /
    • 2002
  • The increasing use of non-linear loads such as power electronics draw highly distorted currents from the utility system High harmonics current, and voltages will cause equipment damage and disturb the plant operation. The application of phase shifting transformers can be a very cost-effective method of harmonic treatment where multiple harmonic sources ice in operation. In this paper simulation results used the EDSA harmonics analysis program verifying the effects of a phase shifting transformer for harmonic elimination are presented.

Analysis of power quality using non-linear load at low voltage system (저압 시스템에서 비선형 부하의 사용에 따른 전력품질 해석)

  • Kim, Jong-Gyeum;Lee, Eun-Woong;Sohn, Hong-Kwan;Kim, Il-Jung
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.660-662
    • /
    • 2001
  • This paper describes the problems generated with the use of PWM ASDs with induction motors. The major effect of harmonic voltages and currents in induction motors is increased the heating due to iron and copper losses at harmonic frequencies. The harmonic components thus affect the motor efficiency and developed the torque. In order to investigate the effect of harmonics which is caused by using of nonlinear load at the low voltage system, we set up simple load system and measured the voltage and current. Measurement results show that additional operation of induction motor at the parallel bus in using nonlinear load such as ASD is helpful to the reduction of harmonic current.

  • PDF