• 제목/요약/키워드: Harmonic Current

검색결과 1,338건 처리시간 0.025초

Improved DPC Strategy of Grid-connected Inverters under Unbalanced and Harmonic Grid Conditions

  • Shen, Yongbo;Nian, Heng
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권2호
    • /
    • pp.169-175
    • /
    • 2014
  • This paper presents an improved direct power control (DPC) strategy for grid-connected voltage source inverter (VSI) under unbalanced and harmonic grid voltage conditions. Based on the mathematic model of VSI with the negative sequence, 5th and 7th harmonic voltage components consideration, a PI controller is used in the proposed DPC strategy to achieve the average output power regulation. Furthermore, vector PI controller with the resonant frequency tuned at the two times and six times grid fundamental frequency is adopted to regulate both negative and harmonic components, and then two alternative targets of the balanced/sinusoidal current and smooth active/reactive output power can be achieved. Finally, simulation results based on MATLAB validate the availability of the proposed DPC strategy.

고조파를 포함하는 부하의 변압기 용량 산정에 관한 연구 (A Study on the Transformer Capability containing Harmonic Load Currents)

  • 김경철;박상영;이일무;백승현
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 학술대회 논문집
    • /
    • pp.287-292
    • /
    • 2004
  • The increasing use of nonlinear loads has resulted in an increase in the harmonic content of the load current for power transformers. Transformers subject to harmonic currents have higher losses and need to be derated. This paper presents a simple method for determining the capability of transformers to supply harmonic load currents and shows that the application of capacitor banks with a series connected reactor and harmonic filters will geatly increase the capability of transformers. The EDSA program was used as a simulation tool for the carse study.

  • PDF

고조파가 고온 초전도 케이블의 운전특성에 미치는 영향 (The Effects of Harmonic Current in the Operating Characteristics of High Temperature Superconducting Cable)

  • 이근준;이종배;황시돌;손송호
    • 전기학회논문지
    • /
    • 제56권12호
    • /
    • pp.2065-2071
    • /
    • 2007
  • This paper suggests the harmonic effects on HTS(High Temperature Superconducting) power cable. HTS cable is regarded as not only one of the important countermeasure to supply high density power demand area, but also one of countermeasures greenhouse technology. However, with the development of digital society, the distribution line power is much contaminated with harmonics generated by various power electronic equipments. This paper describes how the HTS cable responds to the harmonic and increases AC losses caused by hysteresis phenomenon. EMTDC based harmonic simulation results are compared with AC loss measured values.

자기장에 의한 조화가진을 받는 구조물의 위상 최적화 (Topology Optimization of a Structure under Harmonic Excitation caused by Magnetic Fields)

  • 유정훈
    • 대한기계학회논문집A
    • /
    • 제25권10호
    • /
    • pp.1613-1620
    • /
    • 2001
  • This study is focused on the application of the homogenization design method (HDM) to reduce the vibration level of a structure excited by magnetic harmonic farces. This is accomplished by obtaining the optimal material distribution in a design domain to minimize the frequency response caused by the magnetic harmonic excitation. The Maxwell stress method is used to compute the magnetic force and the HDM is applied leer the optimization. The developed method is applied to a simple pole model that is excited by the harmonic bending farce caused by the current around an adjacent stator. Results shows that the HDM is valid to minimize the frequency response.

Harmonic Winding Factors and MMF Analysis for Five-phase Fractional-slot Concentrated Winding PMSM

  • Kang, Huilin;Zhou, Libing;Wang, Jin
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권1호
    • /
    • pp.20-26
    • /
    • 2014
  • To enhance torque density by harmonic current injection, optimal slot/pole combinations for five-phase permanent magnet synchronous motors (PMSM) with fractional-slot concentrated windings (FSCW) are chosen. The synchronous and the third harmonic winding factors are calculated for a series of slot/pole combinations. Two five-phase PMSM, with general FSCW (GFSCW) and modular stator FSCW (MFSCW), are analyzed and compared in detail, including the stator structures, star of slots diagrams, and MMF harmonic analysis based on the winding function theory. The analytical results are verified by finite element method, the torque characteristics and phase back-EMF are also taken into considerations. Results show that the MFSCW PMSM can produce higher average torque, while characterized by more MMF harmonic contents and larger ripple torque.

Harmonic Analysis on the Korean AC Railway System

  • Lee, Han-Min;Kim, Gil-Dong;Oh, Kwang-Hae;Jang, Gil-Soo;Kwon, Sae-Hyuk
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권3호
    • /
    • pp.235-243
    • /
    • 2005
  • Line constants of the catenary system are estimated. The harmonic current that the Korean Train Express (KTX) injects into the catenary is measured to precisely analyze the harmonic effects. The Korean high-speed railway system is modeled by estimated and measured results. The system model is applied for predicting the harmonic effects. The simulation results from the system model are compared to field test data concerning the total harmonic distortion (THD). The reliability of the system model is verified.

유도전동기의 고조파 저감장치 성능 비교 분석 (Analysing and comparing efficiency of harmonic reduction equipment for Induction Motor)

  • 박양범;김두현
    • 한국안전학회지
    • /
    • 제20권3호
    • /
    • pp.47-52
    • /
    • 2005
  • Recently, power conversion equipment increased rapidly makes a lot of harmonics. Thus, it is growing that wrong operation and break down of sensitive devices. There are two kinds of causes of harmonics. One of them is lots of power conversion equipment as modem controller, inverter, converter and SWS(Switching Mode Power Supply). Another is nonlinear operating machines as transformer and motor. The more nonlinear loads like them grow, the more serious problems as harmonic current to source and low power factor because of increasing reactive power grow. It is installed for reactor and L-C Filter to decrease harmonic in general. This paper analysis and compares two of characteristics and harmonic from reactor and L-C Filter with operation of induction motor and power conversion equipment. In the result, L-C Filter more improves unbalance rate and THD than reactor.

계통 고조파와 분산형 전원의 상호작용 평가를 위한 고조파 모델에 관한 연구 (Source Model for Harmonic Interaction Analysis between Renewable Energy Generators and Power Distribution System)

  • 조성민;신희상;문원식;김재철
    • 전기학회논문지
    • /
    • 제60권4호
    • /
    • pp.733-738
    • /
    • 2011
  • As increase of nonlinear loads and renewable energy generators (REGs) being connected to power distribution system via inverters, the concern on harmonic problems have increased. Recently, the harmonics evaluation method considering TDD (Total Demand Distortion) is used to analyze the effect of harmonics from inverters on power distribution quality. Harmonic current sources are typically used for simulation of nonlinear load. Most inverter type for REGs is voltage source inverter (VSI). So, harmonic voltage sources are more suitable to analyze impact of renewable energy generator on harmonics problem in power distribution system. In this paper, we presented the circuit model to analyze interaction between harmonics from nonlinear load and REGs. We verified that the harmonic analysis using the proposed circuit model is more appropriate than the harmonics evaluation method considering TDD through case study using PSCAD/EMTDC.

풍력 유도발전기의 여자 축전지에 따른 고주파 증폭에 관한 기술 동향 (Technical Trend on Excitation Capacitors on Harmonic Amplification of Wind Induction Generator)

  • 노상필;박정석;이영길;최용성;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1976-1977
    • /
    • 2007
  • This paper introduce the electrical quantities of a three-phase-connected wind induction generator (WIG) under sudden connection of static loads. An intelligent power-system recorder/monitor is employed to measure threephase voltages and currents of the studied system at WIG's terminals and load's terminals for 5 minutes. A laboratory 300 W wound-rotor induction machine driven by a blushless DC motor is utilized as the studied WIG. Since the generated harmonic currents are randomly varied, total harmonic distortion (THD) of current using cumulative probability density function is employed to determine the penetration of harmonic distortion. The results show that the harmonic currents generated by the studied WIG may be severely amplified to a high level by the connected self-excited capacitance at the stator's terminals.

  • PDF

Tidal and Sub-tidal Current Characteristics in the Kangjin Bay, South Sea, Korea

  • Ro, Young-Jae
    • Ocean Science Journal
    • /
    • 제42권1호
    • /
    • pp.19-30
    • /
    • 2007
  • This study analyzed the current meter records along with wind records for over 500 days obtained in the Kangjin Bay, South Sea, Korea spanning from March, 2003 to Nov. 2005. Various analyses include descriptive statistics, harmonic analysis of tidal constituents, spectra and coherence, the principal axis, progressive vector diagrams. These analyses can illustrate the response of residual current to the local wind resulting in the net drift with rotational motion. Current speed ranges from -28 to 33 (cm/sec), with standard deviations from 6.5 to 12.9 (cm/sec). The harmonic analyses of the tidal current show the average form number, 0.12 with semi-diurnal type and the rectilinear orientation of the major axis toward northeast. The magnitudes of the semi-major range from 12.7 to 17.7 (cm/sec) for M2 harmonics, while for S2 harmonics, they range from 6.3 to 10.4 (cm/sec), respectively. In the spectral and coherency analysis of residual current and wind, a periodicity of 13.6 (day) is found to be most important in both records and plays an important role in the net drift of residual current. The progressive vector diagrams of residual current and wind show two types of behaviors such as unidirectional drift and rotational motion. It was also found that 3 % rule holds approximately to drive 1 (cm/sec) drift current by 30 (cm/sec) wind speed based on the correlation of the semi-major axis of wind and residual current.